Modern Forms WS-14818 Mini Loft Mode d'emploi

Taper
Mode d'emploi
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
HARDWARE
Wire Connector
Qty: 4pcs
Mounting Screw
Qty: 1 Extra
Conversion Plate
Qty:1pc
Mounting Ring
Qty:1pc
A
BCDE
Driver
Qty:1pc
INSTALLATION INSTRUCTIONS

WS-14818/WS-14824/WS-14836













 









2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
PREPARATION
MOUNT ON 2”X4” SWITCH BOX (Fig. 1)
Fig.1 Mount on Switch Box
4. Connect the Driver (E) input wires to switch box wires as shown in Fig. 4, making sure that all wire connectors (A) are secured. If your outlet
box has a green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to
the back plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box.
* Requires Driver to be recessed in the switch box.
5. Secure the mounting ring to the switch box using junction box screws.The side of the mounting back plate marked “GND” must face out.
6. Connect the Driver’s output wire to the xture wire as Shown in Fig.1. After wires are connected, tuck them carefully inside the switch box.
7. The back plate location is adjustable as shown in Fig.3.
First, loosen both adjustable nuts by turning counterclockwise.Second, adjust the back plate to your desired location.Third, pull and tighten
the electrical wire.Lastly, secure the back plate by turning both adjustable nuts clockwise.
8. Secure the xture to the mounting back plate using the mounting screws (B).
OR
GND
φ4"
Conversion Plate Dimensions
Mounting Ring Dimensions
Back Plate Dimensions
7 1/8”
1 5/8” 1 3/8”
2 3/4”
1 3/4” 1 3/8”
9"
1 3/8”
1 5/8”
4 1/2”
3. Remove the mounting screw (B) from the xture, and then take down the mounting back plate.
1. Shut off the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for
installation.
INSTALLATION INSTRUCTIONS

WS-14818/WS-14824/WS-14836
A
Wire ConnectorGround Wire
Switch Box
Mounting Plate
Junction Box Screw
Fixture Driver 2 7/8"[L]x1 3/8"[W]x1 1/8"[H]
E
Female/Male end connector
B
Mounting
Screw
3
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
MOUNT ON 4”X4” JUNCTION BOX (Fig. 2)
Fig.1 Mount on Junction Box
Fig. 4 Wiring
2
3. Remove the mounting screw (B) from the xture, and then take down the mounting back plate.
4. Connect the Driver (E) input wires to junction box wires as shown in Fig. 4, making sure that all wire connectors (A) are secured. If your
outlet box has a green and bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’ ground wire
directly to back plate using the green screw provided.
* Requires Driver to be recessed in the junction box.
5. Secure the mounting ring (C) to the junction box using junction box screws.The side of the mounting ring marked “GND” must face out.
6. Secure the mounting back plate and conversion plate (D) to the mounting ring with the junction box screws.
7. Connect the Driver’s output wire to the xture wire as Shown in Fig.1. After wires are connected, tuck them carefully inside the junction box.
8. The back plate location is adjustable as shown in Fig.3.First, loosen both adjustable nuts by turning counterclockwise.Second, adjust the
back plate to your desired location.Third, pull and tighten the electrical wire.Lastly, secure the back plate by turning both adjustable nuts
clockwise.
9. Secure the xture to the mounting back plate using the mounting screws (B).
INSTALLATION INSTRUCTIONS

WS-14818/WS-14824/WS-14836
Mounting Plate
Conversion Plate
D
Mounting Ring
Junction Box Screw
C
Driver 2 7/8"[L]x1 3/8"[W]x1 1/8"[H]
E
Junction Box
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.3
B
Mounting
Screw
Adjustable
Nut
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
OVERALL COMPONENT DIMENSIONS
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE
BEGINNING.
-Read all instructions before installing.
-System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
-When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
-Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MISE EN GARDE: POUR ÉVITER TOUT CHOC ÉLECTRIQUE, ASSUREZVOUS QUE LE DISJONCTEUR SOIT MIS HORS TENSION AVANT DE
COMMENCER.
-Lisez toutes les instructions avant l’installation.
-Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements
locaux.
-Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
COMPONENT OVERVIEW
The trimless junction box cover is intended for installation to NEC approved 4” square junction boxes recessed in drywall and ush with the
support structure. It may be covered with spackle and/or plaster to conceal junction box visibility. It is to be connected to compatible Modern
Forms xtures. Refer to specications sheets for more information.
2"
#8
TYP
HARDWARE
Wire Connector
Qty: 3 (+1 Extra)
½” Plastic Spacer
Qty: 2
⁄”-40 x 1⁄” Long
Mounting Screw
Qty: 2 (+1 Extra)
¾” Plastic Spacer
Qty: 2
A
D
B
E
#8-32 x ¾” Long
Junction Box Screw
Qty: 2 (+1 Extra)
1” Plastic Spacer
Qty: 2
C
F
NOTE: This accessory is supplied with an optional mounting C-ring for
xture connection via ⁄” K.O. hole. This component may be omitted
from the installation if mounting xtures using #8 screw holes.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIG. 1
FIG. 2
FIG. 4
TRIMLESS JUNCTION BOX COVER INSTALLATION:
The trimless junction box cover is compatible with NEC approved
4” square junction boxes recessed in drywall and ush with the
support structure.
1. Install compatible junction box (by others) to the framing
structure. Ensure the junction box is ush with the base or front
of framing structure (See FIG. 1).
2. Install the mounting plate to the junction box (See FIG. 2).
Ensure the spacer alignment base is facing outward.
FIG. 3
105mm
105mm
FIG. 5 FIG. 6
3. Determine the drywall thickness and select the appropriate
spacer to install between the mounting plate and the trimless
junction box cover (See FIG. 3).
NOTE: Only 1 matching pair of spacers are to be used per
installation.
4. Using the mounting screws provided, attach the trimless
junction box cover to the mounting plate (See FIG. 4).
5. Make a 4⁄” square cutout in drywall at the intended trimless
junction box cover location and proceed to install to framing
structure (See FIG. 5). Apply and nish spackle up to the center
hole of trimless junction box cover. Ensure #8 holes on the
cover are free of spackle. (See FIG. 6).
Mounting Plate
Plastic
Spacers
Trimless Junction Box Cover
Cover Mounting Screws
Ground Wire
Example: ½” Drywall (No Spacer)
⁄”½”
Spacer Alignment
Base
Spacer
Height
Drywall
Thickness
No Spacer ½”
½” ⁄”
¾” 1”
1” 1¼”
Junction Box
Screws
CB
D
E
F
3Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIXTURE INSTALLATION TO JUNCTION BOX COVER:
The trimless junction box cover features two #8 holes which may be used to mount xtures:
1. Make appropriate splice connections. Wiring may be placed inside the xture or pushed into the junction box.
2. Using #8 mounting screws supplied with the lighting xture, attach the xtures to the #8 holes on the trimless junction box cover. Apply
xture cover or lensing (where applicable) to complete the installation. (See FIG. 7).
Fixture #8 Mounting Screws
FIG. 7
Wire Connector
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Modern Forms WS-14818 Mini Loft Mode d'emploi

Taper
Mode d'emploi