FS COM S5500-48T6SP-R Mode d'emploi

Taper
Mode d'emploi
V1.0
Quick Start Guide
Quick Start Anleitung
Guide de Démarrage Rapide
48PORT GIGABIT STACKABLE L3
POE+ MANAGED SWITCH
STAPELBARER 48-PORT GIGABIT L3 POE+ MANAGED SWITCH
SWITCH MANAGEABLE L3 POE+ EMPILABLE GIGABIT 48 PORTS
S5500-48T6SP-R
1
2
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
1
EN
Introduction
Thank you for choosing FS S5500-48T6SP-R PoE+ Switch. This guide is designed to familiarize you with
the layout of the switch and describes how to deploy the switch in your network.
Accessories
S5500-48T6SP-R
Hardware Overview
Front Panel Ports
RJ45 SFP+ Con
1
2
S5500-48T6SP-R
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
TE1 TE2 TE3 TE4 TE5 TE6
CLI
POESYS
PWR
SWAP
Power Cord x2
Rubber Pad x4 M3 Screws x6
Monitoring Cable x1 Mounting Bracket x2
Grounding Cable x1
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
2
EN
Front Panel Button
SWAP
Ports Description
RJ45
SFP+
10/100/1000BASE-T ports for Ethernet connection
Hot swap SFP+ ports for 1/10G connection
CON A baud rate of 9600bps
Buttons Description
SWAP Swap function, used to switch POE indication.
Front Panel LEDs
RJ45 PWRSYS
POE
Description
The switch is powered on.
The port is linked.
The port is not linked.
LEDs
PWR
SYS
POE
Status
On
Off
The system is being started up.
The system works normally.Blink
On
On
1
2
S5500-48T6SP-R
PoE+
S5500-48T6SP-R
3
EN
PWR2 PWR1
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
Back Panel
Dual Power
Grounding Point
Site Environment
Avoid to damage devices by following the electrostatic discharge prevention procedure.
Ensure that there is adequate air flow around the switch. Make sure the machine box is sealed
because the opened machine box will reverse the cool air flow.
Make sure that the site environment is well-ventilated, the heat of electrical devices is
well-discharged and sufficient air circulation is provided for device cooling.
Desk Mounting
1. Attach four rubber pads to the bottom.
2. Place the chassis on a desk.
Mounting the Switch
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
1
2
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
SWAP
PWR
SYS PoE
4
EN
Rack Mounting
1. Fix the mounting brackets to the two sides of the switch with six M3 screws.
2. Attach the switch to the rack with four M6 screws and cage nuts.
TE1
TE3
TE2 TE4
5
EN
Grounding the Switch
TE1
TE3
TE5
TE7
TE2 TE4
TE6
TE8
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Fix the grounding lug to the grounding point on the back panel of the switch with washers and screws.
CAUTION: The earth connection cannot be removed unless all supply onnections have
been disconnected.
TE3
TE5
TE7
TE4
TE6
TE8
PWR2
PWR1
INPUT
OUTPUT
100-240Vac 50/60Hz 7-3.5A
INPUT
OUTPUT
100-240Vac 50/60Hz 7-3.5A
1
2
3
4
5
6
PoE+
S5500-48T6SP-R
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
SWAP
PWR
SYS PoE
6
EN
1. Plug the AC power cord into the power port on the back panel of the switch.
2. Connect the other end of the power cord to an AC power source.
PWR2
PWR1
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
Connecting the Power
Connecting the Console Port
1. Connect the console port and the terminal or PCs serial port through specific console cable.
2. Run terminal emulation software, such as super Windows terminal.
CAUTION: Do not install power cables while the power is on.
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
SWAP
PWR
SYS PoE
1
2
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
7
EN
Connecting the RJ45 Port
1. Connect an Ethernet cable to the RJ45 port of IP cameras, IP telephones, Access Points (AP), or other
network devices.
2. Connect the other end of the Ethernet cable to the RJ45 port of the switch.
Connecting SFP+ Ports
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or optical fibers without eye protection.
1. Plug the compatible SFP+ transceiver into the SFP+ port.
2. Connect a fiber cable to the fiber transceivers. Then connect the other end of the cable to
network routers or other fiber devices.
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
8
EN
Stacking the S5500-48T6SP-R PoE+ Switch
The S5500-48T6SP-R PoE+ switch support stacking up to 8 units between the same model together.
It can be physically stacked using optical fiber cables connected to SFP+ tranceivers, or 10G Direct
Attach Cables(DAC). Any 2 SFP+ ports on rear panel of the switch can be used for physical stacking.
9
EN
Configuring the Switch
You are now ready to configure the switch. Refer to the S5500-48T6SP-R PoE+ switch Configuration
Guide online for further information.
Step 1: Connect your computer to any Ethernet port of the switch with the network cable.
Step 2: Set up the IP confguration on your computer. The IP address of your computer should be set
in the same subnet addresses of the switch. The IP address is 192.168.1.x ("x" is any number
from 2 to 254).
Step 3: Open a browser. Enter the default IP address of the switch http://192.168.1.1.
Step 4: When the login page appears, choose the language you need and enter the username and
password(admin/admin).
Configuring the Switch Using the Web-based Interface
Sign in
http://192.168.1.1
Username
Password
Your connection to this site is not private
Sign in Cancel
10
EN
Troubleshooting
1. Check the power cable connections at the switch and the power outlet and whether the power
on-off is at "ON" location.
2. Make sure that all cables are used correctly and comply with the Ethernet specifications.
Power LED Working Abnormally
1. Make sure the power supply is normal and the console cable is properly connected.
2. Check whether the console cable is the right type.
3. Check whether the control cable driver is properly installed on the computer.
4. Ensure the parameters of the HyperTerminal are correct.
HyperTerminal Displaying Abnormally
Configuring the Switch Using the Console Port
Step 1: Connect a computer to the switch's console port with the supplied console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Configure the terminal simulation with the following parameters:
Step 4: Enter the username and password(admin/admin).
9600 bits per second
8 data bits
1 stop bit
no sum check bit
no traffic control
CAUTION: Be sure to save settings before exiting the software.
11
EN
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
Product Warranty
FS ensures our customers that if there are any damage or faulty items due to our workmanship, we
will offer a free return within 3 months from the day you receive your goods. This excludes any
custom made items or tailored solutions.
Warranty: This product enjoys 2 years limited warranty against defect in materials or
workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
2
1. Check every port and LED on the switch and make sure the Ethernet cable is connected properly.
2. Try another port on the switch and make sure the Ethernet cable is suitable and works normally.
3. Power off the switch for a while, then power it on again.
4. Make sure the IP address of your PC is set within the subnet of the switch.
5. If you still cannot access the configuration page, please restore the switch to its factory defaults.
Then the IP address of your PC should be set as 192.168.1.x ("x" is any number from 2 to 254) and
Subnet Mask as 255.255.255.0.
Accessing the Web-based Configuration Page Unsuccessfully
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
Einführung
Vielen Dank, dass Sie sich für den FS S5500-48T6SP-R PoE+-Switch entschieden haben. Diese Anleitung
soll Sie mit dem Aufbau des Switches vertraut machen und beschreibt, wie Sie den Switch in Ihrem
Netzwerk einsetzen.
Zubehör
S5500-48T6SP-R
Hardware-Übersicht
Ports an der Vorderseite
RJ45 SFP+ Con
1
2
S5500-48T6SP-R
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
TE1 TE2 TE3 TE4 TE5 TE6
CLI
POESYS
PWR
SWAP
Netzkabel x2
Gummiunterlage x4 M3-Schraube x6
Überwachungskabel x1 Montagehalterung x2
Erdungskabel x1
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
12
DE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
Taste auf der Vorderseite
SWAP
Port Beschreibung
RJ45
SFP+
10/100/1000BASE-T-Ports für Ethernet-Verbindung
Hot-Swap-SFP+-Ports für 1/10G-Verbindungen
CON Baudrate von 9600bps
Taste Beschreibung
SWAP Swap-Funktion, zum Umschalten der PoE-Anzeige.
LEDs an der Vorderseite
RJ45 PWRSYS
POE
Beschreibung
Der Switch ist eingeschaltet.
Der Port ist verbunden.
Der Port ist nicht verbunden.
LED
PWR
SYS
POE
Status
An
Aus
Das System wird hochgefahren.
Das System funktioniert normal.Blinkt
An
An
13
DE
1
2
S5500-48T6SP-R
PoE+
S5500-48T6SP-R
PWR2 PWR1
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
Rückseite
Erdungspunkt
Erdungspunkt
Standortumgebung
Vermeiden Sie Schäden an Geräten, indem Sie das Verfahren zur Vermeidung elektrostatischer
Entladungen befolgen.
Sorgen Sie für eine ausreichende Luftzirkulation um den Switch. Vergewissern Sie sich, dass das
Gehäuse versiegelt ist, da ein geöffnetes Gehäuse einen umgekehrten Kühlluftstrom verursacht.
Stellen Sie sicher, dass die Umgebung des Standorts gut belüftet ist, die Wärme der
elektrischen Geräte gut abgeleitet wird und eine ausreichende Luftzirkulation zur Kühlung
der Geräte gewährleistet ist.
Montage auf einem Tisch
1. Bringen Sie vier Gummiunterlagen an der Unterseite an.
2. Stellen Sie das Gehäuse auf einen Tisch.
Montage des Switches
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
14
DE
1
2
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
SWAP
PWR
SYS PoE
Rack-Montage
1. Befestigen Sie die Montagehalterungen mit sechs M3-Schrauben an den beiden Seiten des Switches.
2. Befestigen Sie den Switch mit vier M6-Schrauben und Käfigmuttern am Rack.
TE1
TE3
TE2 TE4
15
DE
Erdung des Switchs
TE1
TE3
TE5
TE7
TE2 TE4
TE6
TE8
1. Schließen Sie ein Ende des Erdungskabels an eine geeignete Erdung an, z.B. an das Rack, in dem
der Switch montiert ist.
2. Befestigen Sie die Erdungslasche mit Unterlegscheiben und Schrauben am Erdungspunkt auf der
Rückseite des Switches.
ACHTUNG: Der Erdungsanschluss kann nur entfernt werden, wenn alle
Versorgungsanschlüsse getrennt wurden.
TE3
TE5
TE7
TE4
TE6
TE8
PWR2
PWR1
INPUT
OUTPUT
100-240Vac 50/60Hz 7-3.5A
INPUT
OUTPUT
100-240Vac 50/60Hz 7-3.5A
16
DE
1
2
3
4
5
6
PoE+
S5500-48T6SP-R
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
SWAP
PWR
SYS PoE
1. Schließen Sie das Netzkabel an den Netzanschluss auf der Rückseite des Switches an.
2. Schließen Sie das andere Ende des Netzkabels an eine Netzstromquelle an.
PWR2
PWR1
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
INPUT
100-240Vac 50/60Hz 7-3.5A
OUTPUT
Anschließen der Stromversorgung
Anschließen des Konsolen-Ports
1. Verbinden Sie den Konsolen-Port und den seriellen Anschluss des Terminals oder PCs mit einem
bestimmten Konsolenkabel.
2. Führen Sie eine Terminalemulationssoftware aus, z.B. Super Windows Terminal.
ACHTUNG: Schließen Sie die Netzkabel nicht an, wenn der Switch eingeschaltet ist.
17
DE
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
SWAP
PWR
SYS PoE
1
2
3
4
5
6
7
8
9
10
11 13 15
12 14 16
17
18
19
20
21
22
23
24
25
26
27 29 31
28 30 32
33
34
35
36
37
38
39
40
41
42
43 45 47
44 46 48
S5500-48T8SP
CONSOLE
POE
SWAP
PoE
SYS
PWR
PoE+
S5500-48T6SP-R
SWAP
PWR
SYS PoE
Anschließen des RJ45-Ports
1. Schließen Sie ein Ethernet-Kabel an den RJ45-Port von IP-Kameras, IP-Telefonen, Access Points (AP)
oder anderen Netzwerkgeräten an.
2. Schließen Sie das andere Ende des Ethernet-Kabels an den RJ45-Port des Switches an.
Anschließen von SFP+-Ports
WARNUNG: Laserstrahlen können zu Augenschäden führen. Schauen Sie nicht ohne
Augenschutz in die Öffnungen von optischen Modulen oder Glasfasern.
1. Stecken Sie den kompatiblen SFP+-Transceiver in den SFP+-Port.
2. Schließen Sie ein Glasfaserkabel an den Glasfaser-Transceiver an. Schließen Sie dann das andere
Ende des Kabels an Netzwerkrouter oder andere Glasfasergeräte an.
18
DE
Stacking von S5500-48T6SP-R PoE+-Switches
Der S5500-48T6SP-R PoE+-Switch unterstützt das Stacking von bis zu 8 Geräten desselben Modells.
Das Stacking kann über Glasfaserkabel, die an SFP+-Tranceiver angeschlossen sind, oder über 10G
Direct Attach Kabel (DAC) erfolgen. Zwei beliebige SFP+-Ports auf der Rückseite des Switches können
für physisches Stacking verwendet werden.
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
PoE+S5500-48T6SP-R
SWAP PWR
SYS PoE
19
DE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

FS COM S5500-48T6SP-R Mode d'emploi

Taper
Mode d'emploi