Described product
SLT - Smart Light Tower
Manufacturer
SICK AG
Erwin-Sick-Str. 1
79183 Waldkirch
Germany
Legal information
This work is protected by copyright. Any rights derived from the copyright shall be
reserved for SICK AG. Reproduction of this document or parts of this document is
only permissible within the limits of the legal determination of Copyright Law. Any modi‐
fication, abridgment or translation of this document is prohibited without the express
written permission of SICK AG.
The trademarks stated in this document are the property of their respective owner.
© SICK AG. All rights reserved.
Original document
This document is an original document of SICK AG.
2006/42/EC
NO
SAFETY
8026183 / 2021-04-29 | SICK
Subject to change without notice
3
Contents
1 General safety notes......................................................................... 5
2 Notes on UL approval........................................................................ 5
2.1 UL Satisfaction Ratings............................................................................ 5
3 Intended use...................................................................................... 5
4 Product description........................................................................... 6
4.1 Product characteristics............................................................................ 6
5 Operating elements and status indicators.................................... 6
6 Mounting............................................................................................. 7
6.1 Scope of delivery....................................................................................... 7
6.2 Mounting requirements............................................................................ 7
6.3 Notes on mounting................................................................................... 7
6.4 Mounting on the machine housing.......................................................... 7
6.5 Mounting on a rod.................................................................................... 8
6.6 Mounting the Smart Light Buzzer SLB.................................................... 8
7 Electrical installation........................................................................ 9
7.1 Attaching connection cable...................................................................... 10
8 Operation............................................................................................ 11
8.1 Operating modes...................................................................................... 11
8.2 Configuration............................................................................................. 12
9 Troubleshooting................................................................................. 19
10 Disassembly and disposal............................................................... 19
11 Maintenance...................................................................................... 19
12 Technical data.................................................................................... 20
12.1 Technical specifications........................................................................... 20
12.2 Dimensional drawings.............................................................................. 20
13 Annex.................................................................................................. 21
CONTENTS
4
8026183 / 2021-04-29 | SICK
Subject to change without notice
1 General safety notes
Read these operating instructions before commissioning the device.
Connection, mounting and configuration of the device must only be carried
out by qualified personnel.
2006/42/EC
NO
SAFETY
This device does not constitute a safety component as defined in the
Machinery Directive.
Do not install the device in places exposed to direct UV radiation (sunlight)
or other weather conditions unless this is expressly permitted in the operating
instructions.
When commissioning the device, ensure adequate protection against moisture
and contamination.
These operating instructions contain information required during the life cycle of
the device.
2 Notes on UL approval
2.1 UL Satisfaction Ratings
The Smart Light Tower is a UL Recognized Component (file no. E198242).
Standard for safety:
UL 508, Standard for Industrial Control Equipment
CSA C22.2 No. 14-18, Standard for Industrial Control Equipment
The following compliance requirements of UL certification must be considered:
A class 2 voltage supply unit must be used for the voltage supply
3 Intended use
The Smart Light Tower SLT is used for the visual display of machine states or to indicate
filling levels.
The optional Smart Light Buzzer SLB unit is used for acoustic alarms.
Both the 20 LED segments and the acoustic Smart Light Buzzer SLB can be switched
on and off individually. Parameterization for this is done via the IO-Link interface.
Intended use requires that the device is used industrially indoors without any specific
climatic and atmospheric requirements. Any use outside of the areas mentioned in
each case will be considered to be incorrect use and void any warranty claims against
SICK AG. The intended use is only guaranteed if the housing is completely mounted.
In the event of any other usage or modification to the device (e.g., due to opening the
housing during mounting and electrical installation) or changes to the SICK software,
any claims against SICK AG under the warranty will be rendered void.
GENERAL SAFETY NOTES 1
8026183 / 2021-04-29 | SICK
Subject to change without notice
5
4 Product description
4.1 Product characteristics
The Smart Light Tower SLT is a signal lamp used for the visual display of, for example,
machine states or to indicate filling levels. With the Smart Light Buzzer SLB unit, the
device is also suitable for issuing acoustic alarms if needed.
The Smart Light Tower is an IO-Link device that communicates exclusively via the IO-
Link protocol with the higher-level IO-Link master assembly. The IO-Link communication
interface enables direct access to process data and parameter values. The required
IODD can be found at http://www.sick.com/slt.
The device has 20 LED segments. According to IO-Link standards, these LED segments
and the optional buzzer unit can be configured and operated individually. It is possible
to change device parameters during operation. Configuration is performed either via
the SICK SOPAS ET software (available free of charge at www.sick.com) or directly via
the PLC interface.
Further specifications can be found in the technical data (see "Technical data",
page 20).
5 Operating elements and status indicators
1
4
5
5
6
7
2
3
8
9
ß
à
1
Cover
2
Main body
3
20 LED segment display
4
IO-Link status LED
5
Positionsmarkierung
6
Base
7
Waterproof foil
8
Fastening nut (M30)
9
Summereinheit (Optional)
ß
M12 connection (IO-Link)
à
½ inch thread
Display Description
Green LED lights up Device switched on
4 PRODUCT DESCRIPTION
6
8026183 / 2021-04-29 | SICK
Subject to change without notice
Display Description
Green LED flashes IO-Link connection active
off - Device not ready
- No voltage
- Voltage below the limit values
6 Mounting
6.1 Scope of delivery
SLT
Quickstart
6.2 Mounting requirements
For the typical space requirements for the device, see the type-specific dimen‐
sional drawing, see "Technical data", page 20.
Comply with technical data, such as the permitted ambient conditions for opera‐
tion of the device (e.g., temperature range, EMC interference emissions, ground
potential).
To prevent condensation, avoid exposing the device to rapid changes in tempera‐
ture.
Protect the device from direct sunlight.
Only mount the device using the threaded mounting holes provided.
Shock and vibration resistant mounting.
6.3 Notes on mounting
The following requirements are necessary for proper installation:
Switch off the voltage supply before you mount or replace the devices.
Do not apply excessive force when mounting/dismounting the signal lamp and
buzzer unit.
Perform installation on a rugged, level surface.
Install this device where there is no excessive vibration.
Note the maximum permissible tightening torque for the device of 4.5 Nm.
NOTE
This product comes with a waterproof foil on the bottom of the bracket (1 mm).
This must be used during installation. We recommend, however, applying sealant
between the device and the installation surface to guarantee the watertightness
of the device if there are any irregularities present in the installation surface.
If sealing from the nut side (interior of the machine) is required, apply a suitable
sealing compound for the M30 nut to the
1
/
2
-inch NPT thread.
6.4
Mounting on the machine housing
Unscrew the M30 nut on the bottom of the signal lamp. Insert the bottom part of the
signal lamp through the mounting surface and secure the lamp to the machine using
the M30 nut and 4.5 Nm tightening torque.
Attachment of the connection cable is described in "Electrical installation", page 9.
MOUNTING 6
8026183 / 2021-04-29 | SICK
Subject to change without notice
7
1
2
3
1
Mounting surface
2
Ø 31 mm
3
M30 Nut
6.5 Mounting on a rod
Screw a rod with ½-inch NPT onto the female thread of the signal lamp. The recom‐
mended tightening torque is 2.25 Nm.
1
6.6 Mounting the Smart Light Buzzer SLB
NOTE
The SLB (SLB060-0B010K700) is available as an optional accessory (part number
6076072).
6 MOUNTING
8
8026183 / 2021-04-29 | SICK
Subject to change without notice
1.
To unlock it, rotate the cover (1) on the top of the signal lamp in the counterclock‐
wise direction. Lift up the released cover. Note the position markings (2 Locked;
3 Unlocked).
2 3
1
2.
Locate the Smart Light Buzzer (1) on the signal lamp with the position markers as
shown. To lock the buzzer unit and signal lamp together, turn the signal lamp in the
clockwise direction. (2 Unlocked; 3 Locked).
2 3
1
7 Electrical installation
No separate supply voltage connection is required for the SLT. The supply is provided by
the higher-level IO-Link master via the IO-Link interface.
The signal lamp must be connected in a voltage-free state.
U
B
: 18... 30 V DC, see "Technical data", page 20
Table 1: IO-Link port, M12, A-coded, port class A
SLT Signal Description
1 + (L+) +24 V DC
2 n.c. -
3 L- 0 V (logic ground)
4 C/Q IO-Link
5 n.c. -
3
4
2
1
5
ELECTRICAL INSTALLATION 7
8026183 / 2021-04-29 | SICK
Subject to change without notice
9
7.1 Attaching connection cable
1.
Rotate the main body (1) in the counterclockwise direction to unlock it. Note the
position markings while doing so (2 Locked; 3 Unlocked). You can now remove
the main body from the base (4).
2 3
1
4
2.
Now connect the connecting cable (2) to the M12 port (1) on the main body. (3
min. internal diameter)
3. Locate the main body in the base bracket again and rotate the main body in
the clockwise direction to secure the signal lamp. Pay attention to the position
markers while doing so. (1 Unlocked; 2 Locked)
1 2
7
ELECTRICAL INSTALLATION
10
8026183 / 2021-04-29 | SICK
Subject to change without notice
8 Operation
8.1 Operating modes
There are 3 different operating modes for the SLT, which are used to display various
warning and indicator signals:
Signal lamp mode
Filling level mode
Animation mode
8.1.1 Signal lamp mode
In Signal lamp mode, the SLT can be used as a standard signal lamp.
The 20 LED segments can be divided into a maximum of five groups. When evenly
distributed, four LEDs together always form a group. The number of LEDs per group
can be changed individually. Even if only one group is activated, all 20 LEDs are always
used for visualization. Exception: If the group separation function is activated, one row
of LEDs is switched off between the individual segments and the remaining number of
LEDs is reduced to 15.
The colors of the different groups can be selected from a color palette with eight
predefined colors. In addition, another individual color from a total of 21 predefined
colors can be added to the color palette here.
In Signal lamp mode, the LEDs can be set as either continuous light, flashing light,
strobe light, or pulsating light. The light animation frequency can be set individually.
8.1.2 Filling level mode
Filling level mode is used when the SLT is used as a level indicator or filling level display.
For this purpose, a level value is specified in the process data. The higher the level
value (in percent), the more LEDs are switched on at the signal lamp.
Each of the 20 LED segments can be individually colored from 21 predefined colors.
As in Signal lamp mode, each individual segment can be configured with a different
light pattern. Continuous light, flashing light, strobe light or pulsating light is available
for selection. The light animation frequency can be set individually.
Switching on the LEDs can be done either from the bottom end of the device upwards
or from the top end downwards. It is also possible for the segments to change color or
light pattern as soon as the segment above them begins to glow.
There are three options here:
The previously activated segments retain their light animation.
The segments that are already illuminated stop their light pattern animation as
soon as a new segment is added, but remain activated. Only the uppermost
segment shows an animation.
All segments show the light pattern of the uppermost segment to draw attention to
the current filling level, e.g. in the event of an overflow warning.
8.1.3 Animation mode
Animation mode is used to demonstrate the range of functions of the signal lamp. Here
the 20 different LED segments are switched on one after the other in a configured
sequence. In Animation mode, each LED segment of the SLT can be configured individ‐
ually.
OPERATION 8
8026183 / 2021-04-29 | SICK
Subject to change without notice
11
For coloring there are 21 predefined colors are available. In Animation mode, the LEDs
can be set as either continuous light, flashing light, strobe light, or pulsating light. The
light animation frequency can be set individually.
Switching on the LEDs can be done either from the bottom end of the device upwards
(bottom up) or from the top end downwards (top down). It is also possible for the
segments to change color or light pattern as soon as the segment above them begins to
glow.
There are three options here:
The previously activated segments retain their light animation.
The segments that are already illuminated stop their light pattern animation as
soon as a new segment is added, but remain activated. Only the uppermost
segment shows an animation.
All segments show the light pattern of the uppermost segment.
Other properties of the animation, e.g. loop/bounce effect, can also be set in this
mode.
8.2 Configuration
The SLT can be configured and controlled in three different ways:
1 Via SiLink2 IO-Link master and SOPAS ET with extensive graphical user interface
based on the SDD
2 Via IO-Link master (e.g. SIG200) and generic user interface based on the IODD
3 Via IO-Link master with direct access to the device parameters via IO-Link service
and process data (e.g. PLC with IO-Link master terminal)
8.2.1.1 Configuration via SiLink2 master and SOPAS ET
The SLT can be configured on a PC (running Microsoft Windows) using the SOPAS
Engineering Tool (SOPAS Et for short) software.
An IO-Link master is required for configuration and operation of the SLT. When using the
SiLink2 IO-Link master, a comprehensive graphical user interface is available to assist
during configuration. The required SiLink2 IO-Link master can be ordered separately.
The SOPAS Engineering Tool application can be downloaded at www.sick.com.
8.2.1.1.1 SDD installation
A SOPAS Device Description (SDD) is required in order to configure the SLT via graphic
user interface. Start SOPAS ET and install the SDD of the SLT as described in the
following section.
Adding SDD via the device catalog
Open the device catalog (1) and then the SDD installation menu using the gear (2)
icon:
1
2
Keep the default settings and select the SLT from the list of available SDDs after the
SDD search is complete. The SDD will now be installed, close the window when the
installation is complete.
8 OPERATION
12
8026183 / 2021-04-29 | SICK
Subject to change without notice
8.2.1.1.2 Establishing connection to the SLT
A connection between SOPAS ET and the SLT must now be established via SiLink2
master. The device search can be used for this purpose. Open the search settings
using the button in the lower right corner of the window. Select the interface-based
search and make sure that the “IO-Link communication” entry is selected in the
following window. If desired, the configured device search can be saved under
a user-defined name in the next step. SOPAS ET now searches for connected IO-
Link devices. After the search is finished, drag the found SLT to the project area:
SOPAS will now establish a connection to the SLT via IO-Link. You can identify a
successful connection by the green status display of the device tile in the project area:
Double-clicking on the device tile opens the graphical user interface for configuration
and control of the SLT, whose functions are explained in the following sections.
8.2.1.2 Overview of SOPAS ET and the standard functions on the individual pages
The pages for the SLT have the following general layout:
12 3 7 8 9
ß
à
4
5
6
1
Menu
2
Start
3
Display of the current navigation level
OPERATION 8
8026183 / 2021-04-29 | SICK
Subject to change without notice
13
4
Device information
5
Page navigation
6
Notifications
7
Update page
8
Restore factory settings
9
Activate/Deactivate Edit mode
ß
Parameterization page, with sub-pages if applicable
à
Operating mode
Table 2: Function
Menu Click this button to show/hide the “Page selection” menu to make
it easier to navigate on smaller screens. The button is highlighted
in light blue when the device tree is hidden.
Start Click the Start button at any time to return to the “STATUS” device
page.
Device information The product name, the application-specific name, the firmware
version, and the serial number are displayed in this area at the top
left.
Page navigation Clicking on the individual levels displays different parameterization
pages.
Notifications Notifications for the SLT are displayed at the bottom of the screen.
They are provided for informational purposes when exchanging
parameterizations or when errors occur. Each notification can be
acknowledged by clicking on the entry.
Update page After clicking on this button, the page contents are updated.
Restore factory settings When you click on this button, all settings of the SLT are reset to
their factory values.
Edit Click the Edit button to change the settings on the current parame‐
terization page. When the Edit button is pressed, it is highlighted in
light blue. Configurable pages are displayed in gray until Edit mode
is activated.
Operating mode With the SLT, there is only the RUN operating mode. No password
is provided for this operating mode. With other SICK products,
there are other operating modes that require entry of a password.
8.2.1.2.1 STATUS page
The “STATUS” page is the start page for the SLT. On this page, you can set the process
data that is cyclically transmitted to the SLT. The process data available for writing
differs depending on the operating mode set.
8 OPERATION
14
8026183 / 2021-04-29 | SICK
Subject to change without notice
NOTICE
For writing process data on the status side, at least SOPAS ET version V2021.2 is
required. Alternatively, an IO-Link master can be used to write the process data.
The following process data can be set:
Signal lamp mode
The configured LED groups as well as the SLB buzzer can be switched on and off
via the switches.
Filling level mode
Here the text field can be used to specify the filling level value in 0-100% format,
which is transmitted cyclically to the SLT as process data. The SLB buzzer can also
be turned on and off with a switch here.
Animation mode
In this mode, the animation can be switched on and off. The animation can also
be reset and its speed can be adjusted. The SLB buzzer can also be turned on and
off with a switch here.
8.2.1.2.2 Configuration page
The Configuration page is divided into four tabs:
General
Color
Buzzer
Alarm
General tab
In the GENERAL tab, the SLT can be completely shut off. In addition, the brightness of
the lamp can be adjusted. The slider can be used to set values between 0 and 100%
in 10% increments. The Find me function can also be activated here. If this function is
activated, the IO-LINK LED in the lower part of the SLT starts flashing with a frequency
of 1 Hz (clock/pause 50%) until the button is clicked again. This function can be used
to identify devices that have already been mounted.
Color tab
The appearance of the lamp can be configured in the COLOR tab. The operating modes
described in chapter 3.4 are available. Configuration is done by selecting the different
options such as color, light pattern and frequency from the CONFIGURATION OF COLOR
OPERATION 8
8026183 / 2021-04-29 | SICK
Subject to change without notice
15
area on the left. After the desired option has been activated by clicking on it, it can be
transferred to the SLT in the preview in the center area of the page by clicking again
in the desired segment. Operating mode-specific functions are available for selection in
the area on the right. In the center part of the tab, the corresponding configurations are
displayed as previews. The colors and icons signal how each segment is configured.
Figure 1: Color tab
Table 3: Functions of the COLOR tab
Operating mode selection Selection of operating mode:
- Signal lamp mode
- Filling level mode
- Animation mode
Color palette A color palette with 21 different colors is available.
In Signal lamp mode, 7 colors are available in the preselection.
Another color can be added by clicking the button with the plus
sign. By clicking on the desired color, it can be transferred to the
layout at the corresponding position.
Light pattern Four different light patterns are available: Continuous light, flash‐
ing, strobe, pulsating. The illuminated images can be activated by
clicking on them. You can see this with the blue coloring of the
selected button.
The selected light pattern is transferred by clicking on the individ‐
ual segment in the layout.
Frequency The frequency of the flashing, strobing or pulsating light patterns
can also be set.
The following frequencies are available:
- Slow (0.5 Hz)
- Medium (1.5 Hz)
- Fast (2.0 Hz)
The activated frequency is marked in blue.
Switch-on behavior of LEDs This selection is available in Filling level and Animation mode.
A selection is made to determine whether the LEDs turn on from
the bottom end of the SLT upwards (bottom up) or from the top
end downwards (top down).
Segment representation This selection is available in Filling level and Animation mode.
It is defined whether the LEDs should change color or light pattern
as soon as the LED segment above them begins to glow. There are
three options here:
- The previously activated segments retain their light animation.
8 OPERATION
16
8026183 / 2021-04-29 | SICK
Subject to change without notice
- The segments that are already illuminated stop their light pattern
animation as soon as a new segment is added, but remain acti‐
vated. Only the uppermost segment shows an animation.
- All segments show the light pattern of the uppermost segment
Layout The layout shows a preview of the configuration of the SLT. The
colors and icons symbolize how the lamp will look later.
Group separation This function is only available in Signal lamp mode.
Activating the function turns off one LED segment between the
groups. This allows for better visual separation of the individual
groups.
Transfer values This selection is only available in Signal lamp mode.
After changing the size of the individual groups in Signal lamp
mode, this configuration must be transferred to the SLT by clicking
the “Transfer values” button.
Reset This selection is available in Signal lamp and Filling level mode.
Clicking on the RESET button resets the number of LED segments
in Signal lamp mode to the presetting. The limit values are reset in
Filling level mode.
Delete values This function is only available in Signal lamp mode.
By deleting the values, the number of LEDs in the changeable
groups is set to 0 and group 1 is then automatically set to 20.
Configuration of limit val‐
ues
In Filling level mode, a value between 0 and 100% can be set for
each LED segment. It is important to note that the value in each
LED segment may not be higher than the value in the segment
above it.
Animation repetition This selection can be used to set the repetition pattern of the
animation. The Loop (always building up from bottom to top) and
Bounce (first building up from bottom to top, then going down
from top to bottom) properties are available.
Buzzer tab
The SLB alarm unit can be configured in the BUZZER tab. In addition to the volume,
various sound effects can also be set. The following sound effects are available:
Sound effect Description Frequency
1 Off Off
2 Continuous tone Continuous tone 3,378 Hz
3 Beeping Fast, periodic tone 3,378 Hz
4 Whistling Fast, high/low tone 2,016 Hz &
3,012 Hz
5 Sweep Sweeping tone 1,000 Hz &
4,032 Hz
6 Beeping, slowly Slow, periodic tone 3,378 Hz
7 Beeping, with pause Fast, periodic tone with pause
1)
3,378 Hz
8 Whistling, with pause Fast, high/low tone with pause
1)
2,016 Hz &
3,012 Hz
9 Sweep, with pause Sweeping tone with pause
1)
1,000 Hz &
4,032 Hz
1)
Pause: 500 ms on / 500 ms off
OPERATION 8
8026183 / 2021-04-29 | SICK
Subject to change without notice
17
Alarm tab
Three user-defined light patterns (profile 1 to 3) can be configured in the ALARM tab. For
this purpose, an individual color sample can be created after selecting one of the three
profiles. The selection of patterns is done as with the regular color selection in the Color
tab. These three profiles can be selected for display on the STATUS page in all three
operating modes:
Diagnostics page
The current status of the SLT can be checked on the Diagnostics page. If the
device reports an error, it will be displayed here. The sending of IO-Link events can
also be deactivated here.
Identification page
The device identification details are displayed on the Identification page. An appli‐
cation-specific name and a device function name can be specified here.
Settings page
The language of the user interface can be selected on the SETTINGS page.
8.2.1.2.3 Diagnostics page
The current status of the SLT can be checked on the Diagnostics page. If the device
reports an error, it will be displayed here. The sending of IO-Link events can also be
deactivated here.
8.2.1.2.4 Identification page
The device identification details are displayed on the Identification page. An applica‐
tion-specific name and a device function name can be specified here.
8.2.1.2.5 Settings page
The language of the user interface can be selected on the Settings page.
The following settings are possible:
Language: English/Englisch, German/Deutsch
Use the INFORMATION button to get more detailed information about the version of the
interface software.
8.2.1.3 Configuration via IO-Link master based on the IODD
Instead of the SiLink2 IO-Link master, other IO-Link masters can also be used to
configure the SLT. For example, the SIG200 IO-Link master (available at www.sick.com)
enables the use of a graphical user interface generated from the IODD (IO-Link device
description file) of the SLT. No SDD is necessary here, because the configuration is
done directly via the parameters described in the IODD. For more information on the
procedure, please refer to the SIG200 User Manual, which can also be downloaded at
www.sick.com.
8.2.1.4 Configuration via direct access to service and process data
The third option for configuring the SLT is to directly access the service and process
data via an IO-Link master or a PLC with a connected IO-Link master terminal without
using a graphical user interface. When using this type of configuration/control, informa‐
tion about the process data structure for control and service data (ISDUs) is required for
configuration.
NOTE
Detailed information can be found in the IO-Link description (8026795) and / or the
IODD description.
8 OPERATION
18
8026183 / 2021-04-29 | SICK
Subject to change without notice
9 Troubleshooting
The Troubleshooting table indicates which measures are to be taken if the device stops
working.
Table 4: Troubleshooting
LED indicator/fault pattern Cause Measures
Off No voltage or voltage below
the limit values
Check the power supply,
check all electrical connec‐
tions (cables and plug connec‐
tions)
Voltage interruptions Ensure there is a stable power
supply without interruptions
Device is defective If the voltage supply is OK,
replace the device
10 Disassembly and disposal
The device must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electrical and electronic devices
In accordance with international regulations, batteries, rechargeable batteries and
electrical and electronic devices must not be disposed of with household waste.
The owner is required by law to dispose of these devices at the appropriate public
collection points at the end of their service life.
WEEE: This symbol on the product, its packaging or in the document
indicates that a product is subject to the specified regulations.
11 Maintenance
SICK devices are maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the device
Check the fittings and plug connectors
Use a soft cloth moistened with water to clean the device.
Do not use thinners, gasoline or oil.
In case of failure or damage of the SLT caused by aggressive media, no claims for
defects can be asserted.
No modifications may be made to devices.
Subject to change without notice. Specified product properties and technical data are
not written guarantees.
TROUBLESHOOTING 9
8026183 / 2021-04-29 | SICK
Subject to change without notice
19
12 Technical data
12.1 Technical specifications
Smart Light Tower
SLT060-0B010J700
Smart Light Buzzer
SLB060-0B010K700
Part number 6075938 6076072
Supply voltage U
B
DC 18 V ... 30 V -
Current consumption Max. 300 mA
1)
-
Connection M12, 5-pin, A-coded Proprietary connection
Mounting direction Upright Upright
Number of LED segments 20 -
Volume - Typ. 88 dB (at 1 m dis‐
tance)
Frequency - 1,000 - 4,032 Hz
Ambient temperature, operation -25 °C … +50 °C -20 °C … +50 °C
Ambient temperature, storage -30 … +60 -20 °C … +50 °C
Ambient humidity ≤ 90% (non-condens‐
ing)
≤ 90% (non-condens‐
ing)
IO-Link 1.1 -
Enclosure rating IP65 IP65 (in mounted state)
Protection class III III
Dimensions 281 x Ø 60 mm 53.5 x Ø 60 mm
Weight 0.54 kg 0.06 kg
Housing material Polycarbonate (PC) Polycarbonate (PC)
1)
Including accessories for beeper SLB060-0B010K700
12.2 Dimensional drawings
1
4
5
5
6
7
2
3
8
9
ß
à
Ø 60
(2.36)
Ø 52
(2.03)
281 (11.06)
201.5 (7.93)
25
(0.98)
53.5
(2.11)
1
Cover
2
Main body
12 TECHNICAL DATA
20
8026183 / 2021-04-29 | SICK
Subject to change without notice
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193

SICK SLT Smart Light Tower Mode d'emploi

Taper
Mode d'emploi