Master Flow IR61G Mode d'emploi

Taper
Mode d'emploi
New Construction
or Re-Roofing
Determine the location of vents:
Evenly space the roof vents along the width of the roof, marking
the location of all roof vents before cutting holes. Center the holes
between the rafters within 2' from the peak of the roof. Mark a
10" x 10" square outline for the hole on the roof. (Figure 1)
Cut and prepare the opening:
Cut the holes in the sheathing before applying shingles. Shingle up
until the first full course of shingles covers the bottom of the hole.
Cut the excess shingles away from the hole. (Figure 2) (For
increased weather protection on new construction or re-roofing
applications, use an 18”x18” piece of GAF Weather Watch
®
or
GAF StormGuard
®
Leak Barrier. Center the leak barrier over the
hole. Remove release film, press into place and cut away the leak
barrier spanning the hole.)
Position the vent and nail the vent into place:
The top of the IR61 has an up-arrow formed into the flashing.
Make sure the vent is in the proper position. Using the pre-drilled
nail holes, nail the vent securely into place. Seal all seams and nail
heads with an approved sealant, such as silicone or waterproof
caulking* (Figure 3)
* Note: Make sure the sealant is a non-petroleum product.
DO NOT USE ROOFING CEMENTS.
Complete shingle installation:
Continue installing shingles, overlapping the flange on the vent.
Cut the shingles around the top of the vent to match its shape.
(Figure 4)
©2005 GAF Materials Corporation 8/05 • 1361 Alps Road, Wayne, NJ 07470 • Master Flow
®
Technical Services: 1-800-211-9612
IR61 Instructions
Installation of IR61 roof vents should comply
with all local standards and regulations.
CAUTION: Use appropriate safety glasses,
gloves and other equipment to avoid injury.
Figure 4 • Figura 4
Quality You Can Trust Since 1886...
from North America’s Largest Roofing
and V
entilation Manufacturer
Visit us at: www.gaf.com
2'
10"
10"
10"
10"
2'
rafters
vigas
chevrons
faîte de toit
pico del techo
roof peak
Figure 1 • Figura 1
Figure 3 • Figura 3
Figure 2 • Figura 2
2'
10"
10"
Instrucciones para la IR61
Instructions IR61
La instalación de las rejillas de ventilación para techos
IR61 debe cumplir con todos los estándares y reglas
locales. PRECAUCION: Use antiparras de seguridad
apropiadas, guantes ydemás equipamiento de seguri-
dad para evitar lesiones.
L’installation des évents de toiture IR61 devrait
respecter toutes les normes et règlements locaux.
AVERTISSEMENT: Utiliser des lunettes de sécurité,
des gants et autre équipement approprié pour éviter
les blessures.
La calidad en la que usted puede
confiar desde 1886… del fabricante
para techos y ventilación
más grande
de Norteamérica
Une qualité à laquelle vous pouvez
vous fier depuis 1886... du plus gros
fabricant de toitures et ventilation
en
Amérique du Nord
Construcción Nueva
o Re-Techado
Determine la ubicación de las rejillas:
Distribuya las rejillas de ventilación uniformemente a lo ancho del
techo, marcando la ubicación de todas las rejillas de ventilación del
techo antes de perforar los orificios. Centre los orificios entre las
vigas a unos 2' del pico del techo. Marque un perfil cuadrado de
10'' x 10'' para el orificio en el techo. (Figura 1)
Perfore y prepare la abertura:
Perfore los orificios en el revestimiento antes de aplicar las tejas.
Coloque tejas hasta que el primer recorrido completo de tejas cubra
el fondo del orificio. Corte las tejas excedentes del orificio. (Figura 2)
(Para mayor protección climática en construcciones nuevas o en
aplicaciones de re-techado, use un trozo de 18”x18” de GAF
Weather Watch
®
o GAF StormGuard
®
Leak Barrier. Centre la bar-
rera contra filtraciones sobre el agujero. Retire la película liberada,
presione en su lugar y corte la barrera de filtraciones cubriendo
l'alignement vertical.)
Coloque la rejilla de ventilación en posición
y clávela en su lugar:
La parte superior de la IR61 tiene una flecha ascendente formada
en el vierteaguas. Asegúrese que la rejilla de ventilación esté en la
posición correcta. Usando los orificios para clavos pre-taladrados,
clave la rejilla de ventilación seguramente en su lugar. Selle todas
las costuras y cabezas de clavos con un sellador aprobado, como
silicona o calafate impermeable.* (Figura 3)
* Nota: Asegúrese que el sellador sea un producto no derivado del
petróleo. NO USE CEMENTOS PARA TECHOS.
Complete la instalación de las tejas:
Continúe instalando las tejas, superponiendo la brida sobre la rejilla
de ventilación. Corte las tejas alrededor de la parte superior de la
rejilla para igualar su forma. (Figura 4)
Nouvelle construction ou
réfection de toiture
Déterminez l’emplacement des évents:
Espacez également les évents sur la largeur de la toiture, marquant
leur emplacement avant de couper les ouvertures. Centrez les
ouvertures entre les chevrons à l’intérieur de 61 cm (2 pi) à partir
du faîte de toit. Tracez un carré de 25 cm x 25 cm (10 po x 10 po)
pour l’ouverture sur la toiture. (Figure 1)
Coupez et préparez l’ouverture:
Coupez les ouvertures dans le platelage avant l’installation des
bardeaux. Installez les bardeaux en amont jusqu’à ce que le pre-
mier rang complet de bardeaux recouvre la base de l’ouverture.
Coupez l’excédent de bardeaux autour de l’ouverture. (Figure 2)
(Pour une protection additionnelle contre les intempéries sur une
nouvelle construction ou une réfection de toiture, utilisez un
morceau de pare fuite GAF Weather Watch
MD
ou GAF StormGuard
MD
de 45,7cm x 45,7 cm (18 po x 18 po). Centrez le pare-fuite
au-dessus de l'ouverture. Enlevez la pellicule, appliquez une
pression et coupez le pare fuite recouvrant l'ouverture.)
Positionnez l’évent et fixez-le en place:
Le haut du IR61 est marqué d’une flèche dans le solin de l’évent.
Assurez-vous que l’évent est dans la position adéquate. En vous
servant des trous prépercés pour les clous, fixez l’évent solidement
en place. Scellez tous les joints et les têtes de clou à l’aide d’un
scellant approuvé tel que la silicone ou un produit de calfeutrage
imperméabilisant.* (Figure 3)
* Remarque: Assurez-vous que le scellant n’est pas un produit à
base de pétrole. N’UTILISEZ PAS DE BITUME DE COLLAGE.
Complétez l’installation des bardeaux:
Continuez l’installation des bardeaux, chevauchant la bride de
l’évent. Coupez les bardeaux autour de la partie supérieure de
l’évent pour épouser son profil. (Figure 4)
NOTE: In Canada, only the GAF and
Timberline logos are registered trademarks.
NOTA: Solamente los nombres de GAF y
Timberline son marcas registradas en Canadá.
REMARQUE: Seuls les noms GAF et
Timberline sont des marques de
commerce déposées au Canada
Adding an IR61 to
Finished Roofs
Determine the location of vents:
Inspect the attic to determine the location of rafters and other
obstructions. Evenly space the roof vents along the width of the
roof, marking the location of all roof vents before cutting holes.
Center the holes between the rafters within 2' from the peak of the
roof. Mark a 10" x 10" square outline for the hole on the top of
shingles. (Figure 5)
Cut and prepare the opening:
Using a sharp knife, cutaway the shingles (Figure 6A). Cut
through the sheathing using a reciprocating saw (Figure 6B).
Carefully remove the roofing nails within 3'' of the hole. Cut the
shingles at the top of the hole to accommodate the shape of the
roof vent. (For increased weather protection on new construction
or re-roofing applications, use an 18”x18” piece of GAF Weather
Watch
®
or GAF StormGuard
®
Leak Barrier. Center the leak barrier
over the hole. Remove release film, press into place and cut away
the leak barrier spanning the hole.)
Position the vent:
Apply a generous amount of silicone or waterproof
caulking to the perimeter of the hole (Figure 7A).* Slide the vent
into place beneath the shingles, ensuring that the throat of the vent
is centered on the hole. The shingles should overlap the top half of
the vent flange (Figure 7B). The bottom half of the vent’s flange
will be exposed on top of the shingles.
* Note: Make sure the sealant is a non-petroleum product.
DO NOT USE ROOFING CEMENTS.
Nail the vent into place:
Nail the vent into place, using the pre-drilled holes. Replace nails
in the shingles as necessary to ensure a proper seal. Use silicone or
waterproof caulking to seal any exposed nails.* (Figure 8)
* Note: Make sure the sealent is a non-petroleum product.
DO NOT USE ROOFING CEMENTS.
Installation of IR61 roof vents should comply
with all local standards and regulations.
CAUTION: Use appropriate safety glasses,
gloves and other equipment to avoid injury.
Figure 6 • Figura 6
Figure 7 • Figura 7
Figure 8 • Figura 8
©2005 GAF Materials Corporation 8/05 • 1361 Alps Road, Wayne, NJ 07470 • Master Flow
®
Technical Services: 1-800-211-9612
Quality You Can Trust Since 1886...
from North America’s Largest Roofing
and V
entilation Manufacturer
Visit us at: www.gaf.com
2' 2'
10"
10"
10"
10"
rafters
vigas
chevrons
faîte de toit
pico del techo
roof peak
2'
10"
10"
2'
10"
10"
AB
2'
10"
10"
A B
Figure 5 • Figura 5
L’installation des évents de toiture IR61 devrait
respecter toutes les normes et règlements locaux.
AVERTISSEMENT: Utiliser des lunettes de sécurité,
des gants et autre équipement approprié pour éviter
les blessures.
La calidad en la que usted puede
confiar desde 1886… del fabricante
para techos y ventilación
más grande
de Norteamérica
Une qualité à laquelle vous pouvez
vous fier depuis 1886... du plus gros
fabricant de toitures et ventilation
en
Amérique du Nord
Agregando una IR61 a
Techos Terminados
Determine la ubicación de las rejillas:
Inspeccione el ático para determinar la ubicación de las vigas y
demás obstrucciones. Distribuya uniformemente las rejillas de venti-
lación para techos a lo ancho del techo, marcando la ubicación de las
rejillas para techos antes de perforar los orificios. Centre los orificios
entre las vigas a 2' del pico del techo. Marque un perfil cuadrado de
10'' x 10'' para el orificio en la parte superior de las tejas. (Figura 5)
Perfore y prepare la abertura:
Usando un cuchillo filoso, corte las tejas (Figura 6A). Corte a
través del revestimiento usando una sierra recíproca (Figura 6B).
Cuidadosamente retire los clavos para techos a 3'' del orificio.
Corte las tejas en la parte superior del orificio para acomodar el
pico moldeado de la rejilla de ventilación para techos. (Para mayor
protección climática en construcciones nuevas o en aplicaciones de
re-techado, use un trozo de 18”x18” de GAF Weather Watch
®
o
GAF StormGuard
®
Leak Barrier. Centre la barrera contra filtraciones
sobre el agujero. Retire la película liberada, presione en su lugar y
corte la barrera de filtraciones cubriendo l'alignement vertical.)
Coloque la rejilla de ventilación en posición:
Aplique una generosa cantidad de silicona o calafate impermeable al
perímetro del orificio (Figura 7A).* Deslice la rejilla de ventilación
en su lugar debajo de las tejas, asegurándose que la garganta de la
rejilla de ventilación esté centrada sobre el orificio. Las tejas deben
sobresalir de la parte superior de la brida de la rejilla de ventilación
(Figura 7B). La mitad inferior de la brida de la rejilla de ventilación
quedará expuesta sobre las tejas.
* Nota: Asegúrese que el sellador sea un producto no derivado del
petróleo. NO USE CEMENTOS PARA TECHOS.
Clave la rejilla de ventilación en su lugar:
Clave la rejilla de ventilación en su lugar, usando los orificios
pre-taladrados. Reemplace los clavos en las tejas según sea necesario
para garantizar un sellado correcto. Use silicona o calafate imper-
meable para sellar cualquier clavo expuesto.* (Figura 8)
* Nota: Asegúrese que el sellador sea un producto no derivado del
petróleo. NO USE CEMENTOS PARA TECHOS.
Ajout d’un IR61 sur les
toitures terminées
Déterminez l’emplacement des évents:
Examinez l’entretoit pour délimiter l’emplacement des chevrons et
autres obstacles. Espacez également les évents sur la largeur de la
toiture, marquant leur emplacement avant de couper les ouvertures.
Centrez les ouvertures entre les chevrons à l’intérieur de 61 cm
(2 pi) à partir du faîte de toit. Tracez un carré de 25 cm x 25 cm
(10 po x 10 po) sur les bardeaux. (Figure 5)
Coupez et préparez l’ouverture:
Coupez les bardeaux à l’aide d’un couteau bien aiguisé (Figure 6A).
Coupez à travers le platelage à l’aide d’une scie sauteuse (Figure 6B).
Enlevez soigneusement les clous à toiture à l’intérieur de 8 cm (3 po)
de l’ouverture. Coupez les bardeaux au-dessus de l’ouverture pour
accommoder le haut du cylindre de l’évent. (Pour une protection
additionnelle contre les intempéries sur une nouvelle construction
ou une réfection de toiture, utilisez un morceau de pare fuite GAF
Weather Watch
MD
ou GAF StormGuard
MD
‚ de 45,7cm x 45,7 cm
(18 po x 18 po). Centrez le pare-fuite au-dessus de l'ouverture.
Enlevez la pellicule, appliquez une pression et coupez le pare fuite
recouvrant l'ouverture.)
Positionnez l’évent:
Appliquez une généreuse portion de silicone ou de produit de calfeu-
trage imperméabilisant sur le périmètre de l'ouverture (Figure 7A).*
Glissez l’évent en place sous les bardeaux en vous assurant que la
bride est bien centrée sur l’ouverture. Les bardeaux devraient
chevaucher la moitié supérieure de la bride de l’évent (Figure 7B).
La moitié inférieure de la bride sera exposée sur les bardeaux.
* Remarque: Assurez-vous que le scellant n’est pas un produit à
base de pétrole. N’UTILISEZ PAS DE BITUME DE COLLAGE.
Clouez l’évent en place:
Clouez l’évent en place en vous servant des trous prépercés.
Remplacez les clous dans les bardeaux, au besoin, pour garantir
une adhérence adéquate. Utilisez un scellant de silicone ou un pro-
duit de calfeutrage imperméabilisant pour sceller les clous exposés.*
(Figure 8)
* Remarque: Assurez-vous que le scellant n’est pas un produit à
base de pétrole. N’UTILISEZ PAS DE BITUME DE COLLAGE.
La instalación de las rejillas de ventilación para techos
IR61 debe cumplir con todos los estándares y reglas
locales. PRECAUCION: Use antiparras de seguridad
apropiadas, guantes ydemás equipamiento de seguri-
dad para evitar lesiones.
NOTE: In Canada, only the GAF and
Timberline logos are registered trademarks.
NOTA: Solamente los nombres de GAF y
Timberline son marcas registradas en Canadá.
REMARQUE: Seuls les noms GAF et
Timberline sont des marques de
commerce déposées au Canada
  • Page 1 1
  • Page 2 2

Master Flow IR61G Mode d'emploi

Taper
Mode d'emploi