Danfoss Pressure transmitters DST P1XX Guide d'installation

Taper
Guide d'installation
Installation guide
Pressure transmitters
DST P1XX
075R0013
075R0013
© Danfoss | DCS (im) | 2020.06 AN31455060087901-000401 | 1
Electrical connection: See product label
Electrisk tilslutning: Se produktskilt
Elektrischer Anschluss: Siehe Produktschild
Raccordement électrique: Voir étiquette du produit
Conexión eléctrica: Ver la pegatina en el producto
Connessione elettrica: Vedi etichetta sulla confezione
Electrical
connector has
to be mounted
on the Pressure
Transmitter
before pressure
is added on the
application
Elektrisk
tilslutning skal
tilsluttes
tryktransmitteren
før der kommer
tryk på
applikationen
Der elektrische
Anschlusss-
tecker muss am
Drucktransmitter
montiert werden,
bevor Druck
auf die Anlage
gegeben wird
Le transmetteur
de pression doit
être raccordé
électriquement
avant que
l’application
ne soit sous
pression
El conector
eléctrico
tieneque estar
montado en el
transmisor de
presión antes
de que se añada
presión en la
aplicación
Il connettore
elettrico deve
essere montato
sul Trasmettitore
di pressione
prima che venga
applicata
pressione sul
sistema
M12 x 1, 4 pin Metri-Pack 150
AMPseal 16 Deutsch DT04, 4pin
Danfoss
64G101
4 pole
Danfoss
64G102
American and Canadian approvals:
Must be powered by Class 2 power supply
1. Automatic electrical controls acc. to UL 60730-1 and part 2-6 /CAN/CSA E60730 and
part 2-6, file E31024.
2. Equipment for process measurement and control acc. to UL 61010-1 / CSA C22.2 No.
61010-1-12, file E494625.
3. Nonincendive electrical equipment for use in Class I, Div. 2, Groups A, B, C & D
harzarous locations in acc. to UL 121201 / C22.2 No. CSA-213, file E510763.
4. The MWP 50 bar (max. working pressure))’
5. Evaluated for pollution Degree 2
6. Altitude up to 8000 m
7. Max. R.H. 95% non-condensing
8. Overvoltage category I
DST P1XX
ISO 15170,
Bayonet
  • Page 1 1
  • Page 2 2

Danfoss Pressure transmitters DST P1XX Guide d'installation

Taper
Guide d'installation