Spectrum Controls P42C2-SC Mode d'emploi

Taper
Mode d'emploi

Ce manuel convient également à

PN: 1778600501 Spectrum Controls, Inc. Publication 0100290-01A
Installation Instructions
Installing InView Marquee
2706-P4xC2-SC Message Displays
Catalog Number: 2706-P42C2-SC, 2706-P44C2-SC
Inside
Page
Important User Information
2
Overview
3
Environmental Requirements
3
Wire and Safety Guidelines
3
Description of the InView P42C2-SC and 2706-P44C2-SC Displays
4
Parts List
6
Sign Specifications
7
EMI Compliance
7
Certifications
7
Wiring the 2706-P42C2-SC and 2706-P44C2-SC Displays
8
Mounting the 2706-P42C2-SC and 2706-P44C2-SC Displays
16
2706-P4xC2 Display Language Messaging Format Codes
21
Additional Resources
22
Getting Technical Assistance
22
2 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
Important User Information
Solid state equipment has operational characteristics differing from those of electromechanical
equipment. Because of this difference, and also because of the wide variety of uses for solid state
equipment, all persons responsible for applying this equipment must satisfy themselves that each
intended application of this equipment is acceptable.
In no event will Spectrum Controls, Inc. be responsible or liable for indirect or consequential
damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of
the many variables and requirements associated with any particular installation, Spectrum Controls,
Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.
No patent liability is assumed by Spectrum Controls, Inc. with respect to use of information, circuits,
equipment, or software described in this manual.
Reproduction of the contents of this manual, in whole or in part, without written permission of
Spectrum Controls, Inc., is prohibited.
Throughout this manual, when necessary, we use notes to make you aware of safety considerations.
WARNING
WARNING
Identifies information about practices or circumstances that can
cause an explosion in a hazardous environment, which may lead to
personal injury or death, property damage, or economic loss.
NOTE
Identifies information that is critical for successful application and
understanding of the product.
SHOCK HAZARD
Labels may be on or inside the equipment, for example, a drive or
motor, to alert people that dangerous voltage may be present.
BURN HAZARD
Labels may be on or inside the equipment, for example, a drive or
motor, to alert people that surfaces may reach high temperatures.
Installing InView Marquee 2706-P4xC2-SC Message Displays 3
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
AVERTISSEMENT
Actions ou situations risquant de provoquer une explosion dans
un environnement dangereux et d’entraîner des blessures
pouvant être mortelles, des dégâts matériels ou des pertes
financières.
NOTE
Informations particulièrement importantes dans le cadre de
l’utilisation du produit.
DANGER
D’ÉLECTROCUTION
Les étiquettes ci-contre, placées sur l’équipement ou à l’intérieur
(un variateur ou un moteur, par ex.), signalent la présence
éventuelle de tensions électriques dangereuses.
RISQUE DE
BRÛLLURE
Les étiquettes ci-contre, placées sur l’équipement ou à l’intérieur
(un variateur ou un moteur, par ex.), indiquent au personnel que
certaines surfaces peuvent atteindre des températures
particulièrement élevées.
Overview
These instructions show you how to mount InView 2706-P42C2-SC and 2706-P44C2-SC signs with
NEMA Type 12 enclosures.
Environmental Requirements
Observe the following considerations:
These displays are for indoor use only. They should not be exposed continuously to
sunlight.
They must not be hung in windows. Placing a sign in a window invalidates the warranty.
Signs are suitable only for environments that are between 0 ºC and 55 ºC (32 ºF and 131
ºF).
Displays must only be used in an environment where the humidity (non-condensing) does
not exceed 95%.
Install displays with at least 2.5 cm (1 inch) clearance on each end of the case, and at
least 5.1 cm (2 inches) clearance above the case.
Misuse of the product will void the warranty.
Wire and Safety Guidelines
Install the InView display conforming to all Electrical Safety Requirements for Employee
Workplaces in effect locally. In addition to the NFPA general guidelines, use the following
guidelines:
Careful cable routing helps minimize electrical noise. Route incoming power to the
module by a separate path from the communication cables. Do not run the power and
communication wires in the same conduit, or directly next to each other.
4 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
Where power and series communications wires must cross, the intersection should be
perpendicular.
Shield all serial communication wires. Connect the shield to ground at only one point.
NOTE
Description of the 2706-P42C2-SC and 2706-P44C2-SC Displays
InView 2706-P42C2-SC Display:
InView 2706-P44C2-SC Display:
InView 2706-P42C2-SC and 2706-P44C2-SC displays both provide 1200 NITs brightness level.
Power consumption is also much lower than the previous models of 2706-P4xC InView displays.
The resolution for both displays is 7.6 mm (0.3 in). The displays provide 10, user-selectable colors
for fonts and bitmaps. You may scroll images and characters from right-to-left, or left-to-right,
depending on the language. The displays comply with NEMA 12 housing standards.
Installing InView Marquee 2706-P4xC2-SC Message Displays 5
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
2706-P42C2-SC Top View
2706-P42C2-SC Rear View with Rear Access Panel Covers Removed
2706-P42C2-SC Bottom View
2706-P44C2-SC Top View
2706-P44C2-SC Rear View with Rear Access Panel Covers Removed
6 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
2706-P44C2-SC Bottom View
Parts List
Item
Name
Description
A
Ceiling Mount
Optional ceiling mount. Attach provided
hanging brackets here.
B
Micro SD Card Access Panel
Removal panel to access Micro SD card.
C
Rear Bracket Mount
Attach wall mounting brackets at this
location.
D
Rear Communication Access Panel
Removable panel to access RS-232, RS-
484, or Ethernet communication input
connections.
E
Rear Power Access Panel
Removal panel to access 12 to 240 VAC
power input connection.
F
Rear Access Panel Screws
8 to 32 Phillips screws. Take care not to
lose screws.
G
Communication Entry Point
½-inch trade size hole (.875-inch) for AC
power wiring entry.
H
Power Entry Point
½-inch trade size hole (.875-inch) for AC
power wiring entry. Power cable and
grommet are customer-supplied.
I
Cable Tie Wrap Mount
Tie wrap mount for cable management (if
needed)
J
Alternative Communication Entry Point
Alternative ½-inch trade size holes (.875-
inch) for communication wiring with
removable watertight plug. (If used replace
into rear communication entry point (G)).
K
Alternative Power Entry Point
Alternative ½-inch trade size holes (.875-
inch) for power wiring with removable
watertight plug. (If used replace into rear
power entry point (H)).
Installing InView Marquee 2706-P4xC2-SC Message Displays 7
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
Sign Specifications
Sign
model
number
Pitch
LED
rows
LED
columns
LED
colors
Brightness
(typical)
Dimensions
L × W × H
Weight
(approx.)
Input
voltage and
power
draw
2706-
P42C2-
SC
NEMA 12
7.6
mm
0.3 in
16
120
RGB
10
colors
1200 NITS
94.5 × 8.1 ×
18.8 cm
37.2 × 3.2 ×
7.4 in
5.17 kg
11.40 lb
100-240
VAC
at 0.7-0.3 A
maximum
2706-
P44C2-
SC
NEMA 12
7.6
mm
0.3 in
16
240
185.9 × 8.1 ×
18.8 cm
73.2 × 3.2 ×
7.4 in
9.66 kg
21.3 lb
100-240
VAC
at 1.1-0.5 A
maximum
EMI Compliance
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with installation guidelines, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Certifications
Certifications are:
UL 60950-1, 2nd Edition Information Technology Equipment Safety Part 1: General
Requirements
CSA C22.2 No. 60950-1, 2nd Edition Information Technology Equipment Safety Part
1: General Requirements
EN 60950-1:2006/A11:2009/A1:2010/A12:2011/A2:2013
IEC 60950-1:2005 (Second Edition) + Am 1:2009 + Am 2:2013
8 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
Wiring the 2706-P42C2-SC and 2706-P44C2-SC Displays
WARNING
Hazardous voltage.
Contact with high voltage may cause death or serious injury.
Always disconnect power to the InView display prior to servicing.
Maintain separation of circuits. Route the incoming power directly to the
power connections terminal block.
Do not run the power wiring over the logic board.
WARNING
Tension dangereuse.
Toucher un câble a haute tension peut provoquer la mort ou des
blessures graves.
Sortir la prise d'alimentation de l'afficheur avant de le réparer.
Maintenir la séparation des câbles.
Brancher le câble d’alimentation directement au bornier d’alimentation
électrique.
Ne pas faire cheminer le câble d'alimentation le long de la carte
NOTE
Wiring instructions apply to both displays unless indicated.
Wiring Power to the Display
Wiring method must be in accordance with:
In the United States, the National Electrical Code, NFPA 70, and the National Fire
Alarm and signaling Code, NFPA 72.
In Canada, CSA C22.1, Canadian Electrical Code, Part I, Safety Standard for
Electrical Installations, Section 32.
NOTE
Use appropriate conduit fittings and connections to route wires for
power and communication into the power access compartment.
Ensure a provided ferrite is properly installed on the cables as
shown in the supplied photos.
Installing InView Marquee 2706-P4xC2-SC Message Displays 9
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
1. If necessary, disconnect power to the InView P42xC2 display.
2. To access the display’s rear power access panel, remove the 4, 8-32 Phillips screws
holding the panel in place, and remove the cover.
3. Retain the screws in a safe place.
4. The InView Display power terminal block is rated for wire ranges of 20 to 6 AWG
for the power wiring. Two trade holes are provided for wiring (on rear and
underneath of display). Choose the appropriate entry point for your installation
location. If you choose to use the trade hole underneath the display, make sure you
transfer the watertight hole plug and re-install it in the rear trade hole. Pull the
electrical wires through the trade hole. Ensure you follow all applicable, local,
electrical codes for completion of the wiring.
5. Wire the external power to the rear access power panel as shown. Strip the electrical
wires back 6.35 mm (0.25 in), or as needed. Insert the wires into the appropriate
terminal connection using the image and table provided.
Phillips
screws for
rear power
access
panel cover
Rear trade
hole
10 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
6. Tighten the screws to a maximum of 0.79 N-m (7 in-lbs):
Wire Color
Wire Name
Black
Line (Hot) connect to L
White
Neutral connect to N
Green
Ground connect to G
7. In order to comply with Part 15 of FCC Rules, attach one of the provided ferrites
around the incoming power wiring. Secure with one of the provided tie wraps to the
tie wrap anchor.
8. Replace the rear access power panel by inserting the 4 8-32 Phillips screws. Tighten
to a maximum of 1.13 N-m (10.00 in-lbs).
Wiring Communications to the Displays
Wire the Comms module power and communications into the displays as follows:
1. Remove the 4, 8-32 Phillips screws holding the rear communication access panel. Retain the
screws in a safe place.
2. Choose the ½-inch trade hole to remove for your installation location. Two are provided.
3. Route wiring provided in the two-part cable installed inside the Comms module for power and
communication through one of the cable glands provided on the Comms module and through
the trade hole in the display that provides the most convenient access to the communication
terminal block.
4. If the bottom ½ inch trade hole is to be used, remove the watertight hole plug and reinstall it in
to the rear ½ inch trade hole.
Installing InView Marquee 2706-P4xC2-SC Message Displays 11
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
NOTE
Only connect one type of communication type to the display at a
time.
1. Connect the incoming communication wire(s) to the appropriate
terminals or connection point within the Rear Access Panel
Communications terminal compartment. Terminal connection points are
shown below:
Pin
Description
1
EGROUND
2
SHIELD
3
RS485-(A)
4
RS485-(B)
6
5VDC
7
GROUND
8
RS232TXD
9
RS232RXD
10
GROUND
NOTE
Only connect one type of communication type to the display at a time.
Terminal connection points for communication types are listed below.
12 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
RS-232 Communication:
1. Connect the incoming serial wires from the Comms module to the following
terminal connection points:
Pin Number
Terminal Connection
Point
2
Blue: Shield
8
White: RS232TXD
9
Brown: RS232RXD
10
Green: RS232GND
2. For the RS-232 connection, a wire gage between 24 AWG (minimum) and 18
AWG (maximum) is required. Tighten the terminal connection points to a
maximum of 0.56 N-m (5.00 in-lbs).
3. To comply with Part 15 of the FCC rules attach one of the provided ferrites around
the incoming RS-232 wire(s), and secure with one of the provided tie wraps to the
tie wrap anchor. The ferrite must be attached to the sign.
Display with
power and RS-
232
communications
wiring from
Comms Module
(serial)
Comms Module with power and RS-
232 communications wiring
Installing InView Marquee 2706-P4xC2-SC Message Displays 13
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
RS-485 Communication:
1. Connect the incoming serial wires from the Comms module to the following
terminal connection points:
Display Pin Number
Terminal Connection Point
1
Green: EGROUND
2
Blue: SHIELD
3
White: RS485-(A)
4
Brown: RS485-(B)
Jumper between 4 and 5
Yellow: RS485T/RS485-(B)
2. Shielded RS-485 cable is recommended. Connect the shield of the cable to the
SHIELD terminal.
3. Terminate both ends of all RS-485 buses. The last sign in an RS-485 bus should be
terminated by placing a jumper between the RS-485T and RS-485-(B) terminals.
The jumper wire (yellow) is not included.
4. For the RS-485 connection, a wire gage between 24 AWG (minimum) and 18
AWG (maximum) is required. Tighten the terminal connection points to a
maximum of .056 N-m (5.00 in-lbs).
Comms Module with power and RS-
485 communications wiring
Display with
power and RS-
485
communications
wiring from
Comms Module
(serial)
14 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
WARNING
Hazard of damage to electronic equipment.
Failure to ensure that jumper J2 is in the correct position for the
voltage supplied to the InView Comms module can result in
damage to the module circuitry.
Before applying power to the InView Comms Module, check that the
jumper is in the correct position for your application.
WARNING
Danger de dommage pour l'équipement électronique.
S'assurez que le cavalier J2 est dans la position correcte pour la
tension fournie au module de communication InView sinon cela
pourrait entrainer des dommages a l'ensemble des circuits du
module.
InView en tension, vérifiez que le cavalier est dans la position de
voltage adequat pour votre application.
Power Connections in Comms Module:
1. Jumper J2 settings are shown as labeled on the Comms Module board and in 24
VDC or 5 VDC positions.
Check jumper J2 is correctly positioned for your application:
2. Connect the incoming power (Black and Red), serial (White and Brown), and GND
(Green) wires from the Comms module to the terminal block as shown:
Communications
Connector (on Display)
Pin
Stranded wire from Comms
Module Cable 6010nn-nn
Connectors on InView
Comms Module J1
6: 5VDC
RED + 5 V Power
J1 Pin 2
7: GND(PWR)
BLACK: Supply GND (-5 V)
J1 Pin 3
2: Shield
Blue Chassis Ground
J1 Pin 4
Installing InView Marquee 2706-P4xC2-SC Message Displays 15
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
2. Mount the cable grip to the InView display housing, tighten the
locknut finger-tight, and rotate an additional 1/2 turn.
WARNING
Hazard of damage to electronic equipment.
Failure to ensure that jumper J2 is in the correct position for the
voltage supplied to the InView Comms module can result in
damage to the module circuitry.
Before applying power to the InView Comms Module, check that the
jumper is in the correct position for your application.
WARNING
Danger de dommage pour l'équipement électronique.
S'assurez que le cavalier J2 est dans la position correcte pour la
tension fournie au module de communication InView sinon cela
pourrait entrainer des dommages a l'ensemble des circuits du
module.
InView en tension, vérifiez que le cavalier est dans la position de
voltage adequat pour votre application.
NOTE
The 2706-PENETM2C2-SC communication modules are provided
with cable PN 6010104-nn, (3 meters long). The cable combines
power and serial communications. Power for the communications
module comes from display terminals #6 and #7. Serial
communications are via RS-232 from the module to the display
using terminals #8 and #9.
3. Tighten the cable grip cap until the cable is securely fastened.
4. Replace the rear panel power cover with the 4 screws and tighten
the screws to 2.7 N-m (24 in-lbs).
5. Connect the power supply to a power source.
6. If you press the reset button in the module, the module restarts,
initializes, and displays the Communications Module’s MAC
address, its Ethernet IP address, and its Gateway IP addresses as
part of the associated InView display.
7. Write down the values. Example: 192.168.1.100
8. Connect your PC to the other end of the Ethernet network cable
installed in ETH1 on the Comms module and start an Internet
browser.
9. In the Address field, type in the IP address you obtained from the
display to which the Comms Module is connected.
10. Example entry only. Your value will be different: 192.168.1.100
11. The InView User Interface starts up. If you do not have Adobe
Flash Player installed on your computer, the software provides a
link for you to access, download, and install the Flash Player.
Follow Adobe’s instructions to install the Flash Player.
16 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
12. If needed, re-enter the IP address in the Browser.
13. The InView User Interface software starts up and provides you
with a login screen. Enter the default password:
spectrum
The main InView User Interface View window appears.
14. Use the online help to finish setting up your InView and display.
15. Follow directions. If needed, click Help button for specific
instructions:
Mounting the 2706-P42C2-SC and 2706-P44C2-SC Displays
Sign installation must be performed by qualified personnel. Wall mounting brackets and fasteners
are provided with the display. Hardware to fasten the display to the wall or ceiling is not provided as
the appropriate fasteners must be used for brick, stone, or wood etc.
NOTE
Mounting Displays on a Wall
Wall mount brackets dimensions are as follows:
Installing InView Marquee 2706-P4xC2-SC Message Displays 17
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
To mount the sign:
1. Attach the wall mounting brackets to the sign using 4 10-32 × 3/8-in Phillips screws. Tighten
to 2.71 N-m (24.00 in-lbs):
2. Attach the two remaining sign brackets to a metal post, wall, ceiling, or other surface with
sufficient weight bearing rating. It is preferable that you install the display on metal posts
attached directly to studs. Never install the brackets only on sheetrock with toggle bolts.
B
B
A
A
18 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
If installing directly onto a wall or ceiling, use two 5/16-inch lug bolts and washers per
bracket, screwed at least one inch into the center of wood studs. The washer must be snug
against the bracket. The bracket must be snug against the sheetrock or other wall surface.
If a wooden stud is not available in the correct spot, use 3/4 inch thick plywood or a 3/4-
inch metal backing plate attached to studs to secure the bracket.
3. Ensure the wall brackets align with the brackets on the sign.
4. Attach the mounting brackets on each end of the sign to each other as shown below:
5. Use 2 5/16-18×3/4-in Phillips screws (C), and the 2 5/16 lock washers (D) through the
mounting holes as shown below. Secure with the 2, 5/16-18 nuts (E).
6. DO NOT tighten the nuts at this time.
7. Match the alignment holes of the brackets on the sign with the holes of the brackets on the wall
so that the sign is at the desired viewing angle.
8. Fasten the mounting brackets together using the 4, 10-32×3/4-inch Phillips screws (F), the four
#10 lock washers (G), and the 4 10-32 lock nuts (H) through the selected alignment holes on
each end of the sign.
9. Tighten to 2.71 N-m (24.00 in-lbs).
10. Tighten the two 5/16 nuts (E). See step 5 for reference. Tighten to 2.71 N-m (24 in-lbs).
Installing InView Marquee 2706-P4xC2-SC Message Displays 19
PN: 1778600501 Spectrum Controls, Inc. Publication 0100267-01B
NOTE
Keep a minimum 2.54 cm (1.0 in) clearance on all sides of the sign
for adequate ventilation.
Mounting Displays on a Ceiling
Sign installation must be performed by qualified personnel. Ceiling mounting brackets and fasteners
are provided with the display. These brackets allow the customer to hang the sign with the
appropriate braided wire or chain or rope, etc. Hardware to fasten the display to the wall or ceiling is
not provided as the appropriate fasteners must be used for brick, stone, or wood etc.
NOTE
The maximum weight of the displays is 5.17 kg (11.40 lbs) for the 2706-P42C2-SC, and 9.66 kg
(21.30 lbs) for the 2706-P44C2-SC. This is the weight of the displays only, without the attached
2706-PENETM2C2-SC Comms Module. The module, with its attached bracket adds 1.32 kg (2.6
lbs) to the weight of the display.
WARNING
HAZARD of injury to personnel or damage to equipment.
Be sure to place the ceiling brackets so the ceiling bracket flanges face
appropriately as shown below.
Failure to place the ceiling brackets correctly will result in the sign
failing to stay in place when hung from its chains.
A indicates bracket(s).
B indicates bracket screws.
20 Installing InView Marquee 2706-P4xC2-SC Message Displays
Spectrum Controls, Inc. Publication 0100290-01A PN: 1778600501
Hardware to attach the sign to the ceiling varies based on the type of material (concrete, brick,
wood) and is not included.
Installers must use the following guidelines:
The hardware for attaching to the mounting surface must be rated for the mounting
surface.
Hardware for attaching to the mounting surface, including hanging chains, must be
capable of supporting the weight of the sign.
The display cannot be installed directly to drywall, plasterboard, or any other fragile
supports.
The ceiling, or the ceiling-mounted support system must be capable of supporting at least
four times the weight of the sign.
1. Attach the ceiling mounting brackets (A) to the sign using the 4 6-32×3/8-inch Phillips screws
(B) as shown. Tighten to 1.3 N-m (10 in-lbs).
NOTE
Use chains capable of supporting 4 times the total weight of the
signs.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Spectrum Controls P42C2-SC Mode d'emploi

Taper
Mode d'emploi
Ce manuel convient également à

dans d''autres langues