Access Lighting 50185-BS/OPL Mode d'emploi

Taper
Mode d'emploi
IMPORTANT
Before assembling your ACCESS LIGHTING fixture, please make sure that
you carefully read through this instruction sheet.
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH
CIRCUIT CONDUCTOR.
CONSULTER UN ELECTRICIEN QUALIFIE POUR VOUS ASSURER QUE LES
CONDUCTEURS DE LA DERIVATION SONT ADEQUATS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONTSTRUCTION
AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
CE PRODUIT DOIT ETRE INSTALLE SELON LE CODE D’INSTALLATION PERTINENT,
PAR UNE PERSONNE QUI CONNAIT BIEN LE PRODUIT ET SON FONCTIONNEMENT
AINSI QUE LES RISQUES INHERENTS
NOTE: The important safeguards and instructions that appear in this
manual are not meant to cover all possible conditions and situations
that may occur. It must be understood that common sense, caution and
care, are factors that can’t be built into any product. These factors must
be supplied by the person(s) caring for and operating the fixture.
STEP BY STEP INSTRUCTIONS
Before starting your installation disconnect the Power by turning off the
Circuit Breaker or by removing the fuse at the fuse box. Just turning the
light off at the light switch is not sufficient to prevent electrical shock.
MOUNT CROSSBAR
If there is an existing fixture remove it. Expose the
supply wires from the j-box. Mount the crossbar to
the j-box. Gently pull the wires through the center
hole in the crossbar.
1
GENERAL INFORMATION
All electrical connections must be in accordance with all ordinances,
Local and National Electrical Codes. These fixtures are intended for
mounting to a standard 4” x 2 1/2”metal octagon outlet box. The box
must be directly supported by the building structure and U.L. Recognized.
WHAT YOU NEED
Screwdriver
Wire Cutters
Wiring Supplies as Specified
by Electrical Code
2 x 60W/E12/Candelabra
INSTALLATION INSTRUCTIONS
WHAT WE PROVIDE
Crossbar
Mounting Hardware
Back Plate
Metal bar
1 x Glass Shade
COLLECTION
1
CERTIFICATION: cULus DAMP NO. 50183/50184/50185
50183
APPLICATION MODEL NO.
Wall Fixture
Tabo
50184
50185
2
4
2
CERTIFICATION: cULus DAMP NO. 50183/50184/50185
3
MOUNT THE BACK PLATE
Align the holes in the back plate with the protruding
screws from the crossbar. Insert the screws through
the holes in the back plate and secure with
the supplied thumb nuts.
MOUNT THE METAL BAR
Place the metal bar up to the back plate
inserting the sockets into the designated
holes in the metal bar.
CONNECT THE WIRES
Gently pull the supply wires. Connect the black supply
wire to the black fixture wire. Secure with the supplied
wire nuts. Connect the white supply wire to the white
fixture wire. Secure with the supplied wire nuts. Either
wrap the green wire around one of the protruding screws
or connect it to the supply ground wire. Secure all wires
with electrical U.L Certified electrical tape (not supplied).
Tuck all wires carefully into the J-box.
WHAT YOU NEED
Screwdriver
Wire Cutters
Wiring Supplies as Specified
by Electrical Code
2 x 60W/E12/Candelabra
3
CERTIFICATION: cULus DAMP NO. 50183/50184/50185
5
6
Please ensure that the fitting is cool and
switched off before replacing the bulb.
DO NOT use bulbs that might exceed the
maximum wattage, stated on caution label.
CAUTION
RESTORE THE ELECTRICITY AND
CHECK THE OPERATION OF YOUR
NEW ACCESS LIGHTING FIXTURE
SECURE THE GLASS SHADE
Secure the glass shade to the fixture, by
aligning the holes the glass with the sockets. Insert
the sockets into the glass. Secure with the supplied
socket ring. Insert the bulbs. MAXIMUM
WATTAGE 60W. DO NOT EXCEED THE MAXIMUM
WATTAGE AS STATED ON THE WARNING LABEL AND
INSTRUCTION SHEETS.