AquaPower AQM 3-1 Operation and Installation

Taper
Operation and Installation

Ce manuel convient également à

OPERATION AND INSTALLATION
FUNCIONAMIENTO E INSTALACIÓN
MODE D’EMPLOI ET INSTALLATION
TANKLESS ELECTRIC WATER HEATER WITH ELECTROMECHANICAL FLOW SWITCH
CALENTADOR DE AGUA ELÉCTRICO SIN TANQUE CON SENSOR ELECTROMECÁNICO DE FLUJO
CHAUFFE-EAU ÉLECTRIQUE SANS RÉSERVOIR AVEC CONTACTEUR DEBITMETRIQUE ÉLECTROMÉCANIQUE
» AQM 2-1
» AQM 2.5-1
» AQM 3-1
» AQM 3.5-1
» AQM 4-2
» AQM 6-2
Conforms to ANSI/UL Std. 499
Certied to CAN/CSA Std. C22.2 No. 110
Conforme a ANSI/UL Std. 499
Certicación con CAN/CSA Std. C22.2 No. 110
Conforme à la norme ANSI/UL Std. 499
Certié à la norme CAN/CSA Std. C22.2 No. 110
Tested and certied by WQA to NSF/ANSI372
for lead free compliance.
Probado y certicado por WQA NSF/ANSI 372 para
el cumplimiento de las regulaciones sin plomo.
Testé et certié par WQA à la NSF/ANSI 372 pour une
utilisation sans plomb.
2 | AQM TANKLESS ELECTRIC WATER HEATERS WWW.APTANKLESS.COM
CONTENTS | OPERATION
GENERAL INFORMATION
1. General Information
Read this entire manual. Failure to follow all the guides,
instructions and rules could cause personal injury or property
damage. Improper installation, adjustment, alteration, service
and use of this unit can result in serious injury.
This unit must be installed by a licensed electrician and
plumber. The installation must comply with all national, state
and local plumbing and electric codes. Proper installation is
the responsibility of the installer. Failure to comply with the
installation and operating instructions or improper use voids
the warranty.
Save these instructions for future reference. Installer should leave
these instructions with the consumer.
If you have any questions regarding the installation, use or
operation of this water heater, or if you need any additional
installation manuals, please call our technical service line at
800.582.2213 (USA and Canada only). If you are calling from
outside the USA or Canada, please call USA ++413-247-3380 and
we will refer you to a qualied AquaPower
®
service representative
in your area.
!
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED
TO ALERT YOU TO POTENTIAL PERSONAL INJURY
HAZARD. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS
SYMBOL TO AVOID POSSIBLE INJURY OR DEATH.
The chapter Operation is intended for homeowners, heating
contractors, plumbers and electricians.
The chapter Installat i on is intended for heating contractors,
plumbers and electricians only.
1.1 Symbol key
1.1.1 Layout of safety information
DANGER Electric shock
Before any work on the appliance,
disconnect all poles from the power
supply.
1
3
4
2
1 Symbol (see 1.1.2 "Symbols", below)
2 Keyword (see 1.1.3 "Keywords", below)
3 Description (see 1.1.2 "Symbols", below)
4 Information text
1.1.2 Symbols
Symbol Description
Injury
Electrocution
Burns or scalding
!
Other situations
1.1.3 Keywords
KEYWORD
DANGER
The keyword DANGER indicates information
that must be observed, otherwise serious injury
or death will result.
WARNING
The keyword WARNING indicates information
that must be observed, otherwise serious injury
or death may result.
CAUTION
The keyword CAUTION indicates information
that must be observed, otherwise relatively
serious or light injuries may result.
1. General Information___________________________ 2
1.1 Symbol key ����������������������������������� 2
2. Safety precautions ____________________________ 3
3. Register your product _________________________ 3
4. Temperature increase above ambient water
temperature _________________________________ 4
5. Technical drawings ____________________________ 4
6. Overview ____________________________________ 6
6.1 General Description ���������������������������� 6
6.2 Important information before supplying power to unit 6
6.3 Hot water output ������������������������������ 6
6.4 Incorrect use ���������������������������������� 7
6.5 First steps to be taken in the event of malfunction ���� 7
6.6 Maintenance and care �������������������������� 7
7. Installation instructions _______________________ 7
7.1 Mounting the unit ������������������������������ 7
7.2 Plumbing connections �������������������������� 7
7.3 Electrical connection ��������������������������� 8
8. Initial start-up ________________________________ 8
9. Water heater hand over ________________________ 8
10. Normal maintenance __________________________ 8
11. Technical data ________________________________ 9
12. Troubleshooting ______________________________ 9
13. Spare parts __________________________________ 10
14. Warranty ___________________________________ 11
ENGLISH
WWW.APTANKLESS.COM AQM TANKLESS ELECTRIC WATER HEATERS | 3
GENERAL INFORMATION
SAFETY PRECAUTIONS
2. Safety precautions
!
PLEASE READ AND FOLLOW THESE
INSTRUCTIONS. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN SERIOUS BODILY
INJURY OR DEATH.
THE UNIT MUST BE INSTALLED BY A LICENSED
ELECTRICIAN AND PLUMBER. THE INSTALLATION MUST
COMPLY WITH ALL NATIONAL, STATE AND LOCAL
PLUMBING AND ELECTRIC CODES. SERVICE OF THE
UNIT MUST BE PERFORMED BY QUALIFIED SERVICE
TECHNICIANS.
BEFORE PROCEEDING WITH ANY INSTALLATION,
ADJUSTMENT, ALTERATION, OR SERVICE OF
THIS UNIT ALL CIRCUIT BREAKERS AND DISCONNECT
SWITCHES SERVICING THE UNIT MUST BE TURNED OFF.
FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL
INJURY OR DEATH.
DANGER: NEVER REMOVE THE UNIT'S COVER
UNLESS THE ELECTRICITY SERVICING THE UNIT
IS TURNED OFF. FAILURE TO DO SO COULD RESULT IN
PERSONAL INJURY OR DEATH.
DANGER: WATER TEMPERATURES OVER 125 °F
52 °C CAN CAUSE SEVERE BURNS INSTANTLY
OR DEATH FROM SCALDING. A HOT WATER SCALDING
POTENTIAL EXISTS IF THE THERMOSTAT ON THE UNIT IS
SET TOO HIGH. HOUSEHOLDS WITH SMALL CHILDREN,
DISABLED OR ELDERLY PERSONS MAY REQUIRE THAT
THE THERMOSTAT BE SET AT 120 °F 49 °C OR LOWER TO
PREVENT POSSIBLE INJURY FROM HOT WATER.
WARNING: THE UNIT MUST BE PROPERLY
GROUNDED. FAILURE TO ELECTRICALLY GROUND
THE PRODUCT COULD RESULT IN SERIOUS PERSONAL
INJURY OR DEATH.
3. Register your product
You must register this product within 90 days of
purchase on our web site in order to activate the
standard warranty or to be eligible for the extended war-
ranty. Go to our web site at www.aptankless.com and click
on register your product.
Before beginning the registration process, we suggest
that you gather the necessary information which will be as
follows:
Type, Example: AQM 3-1 [ Mini 3 ] (from the white label that is
on the right side of the unit)
Number listed after "Nr."
Place of Purchase
Purchase Date
First & Last Name
Email address
Physical Address
Phone Number
If you have any questions concerning the registration pro-
cess or warranty options, please contact AquaPower
®
USA
directly at 800.582.2213.
Limited liability warranty:
AquaPower
®
is not liable for damages to the unit, damage to
personal property, bodily injury, or loss of life due to the following
conditions:
- Non-observance of these instructions
- Incorrect use (heating any other liquid than water)
- Installation of the appliance by unqualied personnel
- Unauthorized modications
- Technical modications
- Use of unauthorized spare parts
The one year warranty covers all parts but does not cover
damage to the unit due to hard water. See section 14,
“Warranty, pg. 11 for complete warranty details. If you
know or suspect that the water in your area is hard (has
a high mineral content), it is necessary to install a water
softening device to avoid damage to the AQM unit.
4 | AQM TANKLESS ELECTRIC WATER HEATERS WWW.APTANKLESS.COM
GENERAL INFORMATION
TEMPERATURE INCREASE ABOVE AMBIENT WATER TEMPERATURE
AQM 4-2
3.5 57 50 45 35
AQM 3.5-1
3.5 57 50 45 35
[ °F ]
Min. water ow to activate unit. * AQM 2-1 is internally restricted to 0.32 gpm
AQM 3-1
3.0 49 43 41 30
AQM 2-1
*
1.8 38 – – – – –
Type kW GPM
0.32 0.42 0.48 0.5 0.69 0.85 1.06 1.14
AQM 6-2
5.7 – – – – 46 37 34
AQM 2.5-1
2.4 39 34 33 24
1.2 1.6 1.8 2.0 2.6 3.2 4.0 4.3
Type kW l/min
[ °C ]
Min. water ow to activate unit. * AQM 2-1 is internally restricted to 1.2 l/min
AQM 3-1
3.0 27 24 22 17
AQM 3.5-1
3.5 31 28 25 19
AQM 2-1
*
1.8 22 – – – – –
AQM 2.5-1
2.4 22 19 17 13
AQM 4-2
3.5 31 28 25 19
AQM 6-2
5.7 – – – – 26 20 19
5 /
5
8
(143 mm)
3
/
16
(4,8 mm)
13
/16 (20 mm)
1/
3
16
(30 mm)
4
¾
(120 mm)
6 ½
(165 mm)
7½” (190 mm) 3¼” (82 mm)
3/8” O.D.
ex connector
3 ¾ (95
mm)
C26�02�05�0009
1
2
4
3
A
4. Temperature increase above ambient water temperature
5. Technical drawings
Figure A legend
1 Hot water connection
2 Cold water connection with lter screen
3 Filter screen
4 Mounting holes
ENGLISH
WWW.APTANKLESS.COM AQM TANKLESS ELECTRIC WATER HEATERS | 5
GENERAL INFORMATION
TECHNICAL DRAWINGS
C26�02�05�0010
V >
p >
L N
L N GRD
L L GRD
AQM 2-1/2.5-1/3-1/3.5-1
AQM 4-2/6-2
5
6
7
8
9
10
CB
D
Figure C legend
5
Electrical junction box
6 Water supply line for faucet installation
7 Sink
8 Cold valve (right)
9 Hot valve (left)
10
Shut o valve
11
Reset button from safety pressure cut out
OPERATION
OVERVIEW
6 | AQM TANKLESS ELECTRIC WATER HEATERS WWW.APTANKLESS.COM
6. Overview
6.1 General Description
The AQM tankless water heater diers from conventional storage
type water heaters in several ways. It does not store hot water.
Instead, water is heated instantaneously as it ows through the
unit. The powerful heating elements are activated by a ow
switch as water is drawn from a hot water faucet connected to
the AQM. Due to the absence of stand-by losses, the AQM oers
greater energy eciency than storage type water heaters. The
unit will continuously supply hot water as long as the faucet is
open.
The temperature of the hot water delivered by the AQM depends
on the wattage of the heating element, the temperature of the
incoming cold water, and the water ow rate through the unit.
In order for the AQM to operate properly, it must be carefully
matched to the application.
In case you have questions regarding the way you plan to use the
AQM, please call our technical service line at 800.582.2213 (USA
and Canada). For service outside the U.S. and Canada, please call
us at USA 413.247.3380. You can also e-mail us at info@aptankless.
com or fax us at 413.247.3369.
The AQM can be used for hand washing type applications in
the U.S. and Canada:
Restroom sinks in commercial/industrial facilities
and homes
Kitchen areas in commercial /industrial facilities
and homes
– Cabins
Special uses in photo developing shops,
laboratories etc.
The AQM can also be used for whole apartments and homes in
warm climate zones such as the Caribbean region, Central America
and Mexico due to the higher ambient water temperatures.
This manual must be read carefully before attempting to install the aqm water heater. If you do not follow the safety
rules or the instructions outlined in this manual, the unit may not operate properly and it could cause property damage,
serious bodily injury and/or death.
AquaPower
®
will not be liable for any damages because of failure to comply with the installation and operating instructions
outlined in this manual or because of improper use. Improper use includes the use of this appliance to heat any liquid
other than water. Failure to comply with the installation and operating instructions or improper use voids warranty. Never
remove the units cover unless the electricity is turned o.
If you have any questions regarding the installation or operation of this water heater, or if you need any additional
installation manuals, please call our technical service line on 800.582.2213 (USA and Canada only). If you are calling
from outside the U.S. Or Canada, please call usa 413-247-3380 and we will refer you to a qualied AquaPower
®
service
representative in your area.
6.2 Important information before supplying power
to unit
Air in the cold water pipe will destroy the bare-wire
heating system of the AQM. If the water supply to
the AQM has been interrupted, for example due to the risk
of frost or work on the water pipe, the following steps must
be carried out before the unit is used again.
» 1. Turn o circuit breaker.
» 2. Open a hot water tap downstream of the unit for as long
as is necessary for the unit and the cold water pipe to be
free of air.
» 3. Turn on circuit breaker.
All information in these Instructions for Use and Installation
must be followed carefully. They provide important
information with regard to safety, operation, installation,
and maintenance of the device.
6.3 Hot water output
Model Wattage @ max
rated voltage
Typical hot water output
AQM 2-1 1.8 kW 0.32 gpm / 1.2 l/min
AQM 2.5-1 2.4 kW 0.50 gpm / 1.9 l/min
AQM 3-1 3.0 kW 0.50 gpm / 1.9 l/min
AQM 3.5-1 3.5 kW 0.66 gpm / 2.5 l/min
AQM 4-2 3.5 kW 0.66 gpm / 2.5 l/min
AQM 6-2 5.7 kW 1.00 gpm / 3.8 l/min
AQM 2-1 models are internally restricted to 0.32 gpm (1.3 l/
min). AQM 2-1, 2.5-1, 3-1 ship with a 0.5 gpm (1.9 l/min) pressure
compensating ow reducer/aerator that must be installed. AQM
3.5-1, 4-2 ship with a 0.66 gpm (2.5 l/min) pressure compensating
ow reducer/aerator that must be installed.
ENGLISH
WWW.APTANKLESS.COM AQM TANKLESS ELECTRIC WATER HEATERS | 7
INSTALLATION
INSTALLATION INSTRUCTIONS
6.4 Incorrect use
The following are not permitted and will void the factory
warranty:
- Installation of the appliance where it is at risk
from frost
- Installation in rooms where the appliance is at risk from
explosions as a result of dust, gases or vapors
- Ignoring safety clearances and safety zones
- Incorrect power connection
- Operation of the appliance without water owing through
the unit, or with air in the lines (See section 8, “Initial start-
up”, pg. 8)
- Operation of the unit with the cover o
- Heating liquids other than potable water
6.5 First steps to be taken in the event of
malfunction
WARNING: ALWAYS SHUT OFF POWER AND WATER
TO THE UNIT PRIOR TO REMOVING THE FILTER
SCREEN. FAILURE TO DO SO MAY CAUSE SERIOUS BODILY
INJURY OR DEATH.
» Check the circuit breaker
» Check the lter screen for scale blockage or dirt
accumulation. See section 12, “Troubleshooting”, pg. 10.
6.6 Maintenance and care
!
MAINTENANCE WORK, SUCH AS CHECKING
ELECTRICAL SAFETY, MAY ONLY BE CARRIED OUT
BY A QUALIFIED INSTALLER.
WARNING: ALWAYS SHUT OFF POWER AND WATER
TO THE UNIT PRIOR TO REMOVING THE FILTER
SCREEN. FAILURE TO DO SO MAY CAUSE SERIOUS BODILY
INJURY OR DEATH.
Regularly clean and descale the lter screen located in the cold
water inlet connection and if necessary replace. Always shut o
power and water to the unit prior to removing the lter screen.
A damp cloth is sucient for cleaning of the unit's housing. Do
not use any abrasive or corrosive cleaning agents.
7. Installation instructions
Keep these instructions carefully and pass them on
to your successor in the event of a change in owner-
ship, in the event of maintenance and possible repair work
they should be passed to the qualied installer for his or
her reference.
7.1 Mounting the unit
!
UNIT MUST BE INSTALLED WITH THE PLUMBING
CONNECTIONS POINTING DOWNWARD OR UP-
WARD ONLY.
WARNING: DO NOT INSTALL UNIT WHERE IT WOULD
ROUTINELY BE SPLASHED WITH WATER. ELECTRIC
SHOCK OR DEATH MAY RESULT.
» 1. Install AQM as close as possible to the hot water draw-o
point, for example, directly underneath the sink or next to
the shower stall.
» 2. Install AQM in a frost-free area. If frost may occur, remove
unit before freezing temperatures set in.
» 3. Leave a minimum of 5" of clearance on all sides for
servicing.
» 4. Remove plastic cover by removing screws located on the
left and right sides of the unit
B
.
» 5. Remove plastic backplate by pulling on the tab with a
screwdriver
B
.
» 6. Mount backplate securely to wall by putting two screws
through mounting holes
A B
.
» 7. Snap unit back onto mounting plate
B
.
» 8. Reinstall cover with screws on left and right side of unit
B
.
7.2 Plumbing connections
Note: if soldering near the unit is necessary, please
direct the ame away from the housing of the unit in
order to avoid damage. Excessive heat from soldering on cop
per pipes near the aqm may cause damage.
All plumbing work must comply with national and appli-
cable state and local plumbing codes.
» 1. All plumbing work must comply with national and
applicable state and local
plumbing codes.
» 2. A pressure reducing valve must be installed if the cold
water supply pressure exceeds 150 PSI (10 bar).
» 3. Make certain that the cold water supply line has been
ushed to remove any scale and dirt.
» 4. Install isolating valve in cold water line as shown in
illustration
C
. This allows the unit to be isolated for
maintenance purposes.
» 5. Cold water connection (inlet) is on the right side of the
unit, hot water connection (outlet) is on the left side of unit.
» 6. Tankless water heaters such as the AQM are not required
to be equipped with a Pressure and Temperature Relief
Valve (except in Massachusetts). If the local inspector will
not pass the installation without a P+T valve, it should be
installed on the hot water outlet side of unit.
8 | AQM TANKLESS ELECTRIC WATER HEATERS WWW.APTANKLESS.COM
INSTALLATION
INITIAL STARTUP
» 7. The AQM is designed for connection to a braided
stainless steel hose with a 3/8“ OD Tube Outlet.
» 8. When all plumbing work is completed, check for leaks
and take corrective action before proceeding.
7.3 Electrical connection
WARNING: BEFORE BEGINNING ANY WORK ON THE
ELECTRIC INSTALLATION, BE SURE THAT THE MAIN
CIRCUIT BREAKER PANEL SWITCH IS "OFF" TO AVOID ANY
DANGER OF ELECTRIC SHOCK. FAILURE TO DO SO MAY
RESULT IN SERIOUS INJURY OR DEATH. ALL MOUNTING AND
PLUMBING MUST BE COMPLETED BEFORE PROCEEDING
WITH ELECTRICAL HOOKUP. WHERE REQUIRED BY
LOCAL, STATE OR NATIONAL ELECTRICAL CODES, THE
CIRCUIT SHOULD BE EQUIPPED WITH A GROUND FAULT
INTERRUPTER.
WARNING: AS WITH ANY ELECTRIC APPLIANCE, FAILURE
TO ELECTRICALLY GROUND UNIT MAY RESULT IN
SERIOUS INJURY OR DEATH.
CAUTION: INSTALLING AN AQM 21, AQM 2.51, AQM 31,
OR AQM 3.51 ON A 208 V OR 220240 V CIRCUIT WILL
DESTROY THE HEATING ELEMENT. THIS IS CONSIDERED
IMPROPER INSTALLATION AND WILL VOID YOUR
FACTORY WARRANTY.
Voltage
AQM 2-1: 110120 V
AQM 2.5-1: 110120 V
AQM 3-1: 110120 V
AQM 3.5-1: 110120 V
AQM 4-2: 220240 V, 208 V
AQM 6-2: 220240 V, 208 V
1. All electrical work must comply with national and applicable
state and local electrical codes.
2. The AQM should be connected to a properly grounded
dedicated branch circuit of proper voltage rating. In installa-
tions with several AQM units, each unit requires an independent
circuit. Please refer to the technical data table for the correct wire
and circuit breaker size.
3. Reinstall plastic cover.
8. Initial start-up
!
WARNING: OPEN HOT WATER FAUCET FOR A FEW
MINUTES UNTIL WATER FLOW IS CONTINUOUS AND
ALL AIR IS PURGED FROM WATER PIPES. THE UNIT’S PLASTIC
COVER MUST BE INSTALLED BEFORE THE CIRCUIT BREAKER
IS TURNED ON.
26�02�02�0436
2
1
press
on
on
e
le
c
tro
n
ic
°C
2.
electronic
°C
electronic
°C
1.
electronic
°C
X1
press
on
on
e
le
c
tr
o
n
ic
°C
2.
electronic
°C
electronic
°C
1.
electronic
°C
X1
9. Water heater hand over
Explain the functions of the unit to the user and familiarize him
or her with its use.
Important instructions:
» Draw the users attention to possible hazards (scalding).
» Hand over these instructions for future reference.
» In order to obtain a proper temperature at a single spout
mixer-type faucet, restrict cold water ow to faucet by
partially closing the cold water shut-o valve under the sink
until cold water and hot water ow rates are approximately
the same.
10. Normal maintenance
!
CAUTION: OTHER THAN THE FILTER SCREEN, THE
AQM DOES NOT CONTAIN ANY PARTS SERVICEABLE
BY THE LAY PERSON. IN CASE OF MALFUNCTION PLEASE
CONTACT A LICENSED PLUMBER OR ELECTRICIAN.
AquaPower AQM tankless heaters are designed for a very long
service life. Actual life expectancy will vary with water quality
and use. The unit itself does not require any regular maintenance.
However, to ensure consistent water ow, it is recommended
to periodically remove scale and dirt that may build up at the
aerator of the faucet or in the shower head. Also, the AQM has
a built in lter screen that should be cleaned from time to time.
In order to do this, turn o the cold water supply at the isolating
valve. Clean screen and put the screen back into its original
position.
ENGLISH
WWW.APTANKLESS.COM AQM TANKLESS ELECTRIC WATER HEATERS | 9
INSTALLATION
TECHNICAL DATA
11. Technical data
AQM
21 AQM 2.51 AQM
31 AQM
3.51 AQM 42 AQM 62
Item number 231045 232098 220816 232099 222039 220817
Phase
1 1 1 1 1 1
Voltage
110 120 V 110 120 V 110 120 V 110 120 V 220–240 V 208 V 220–240 V 208 V
Wattage
1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW
Max. amp, load
15 A 20 A 25 A 29 A 14.6 A 12.7 A 23.8 A 20.6 A
Min. recommended
circuit breaker size
1
15 A
(sp)
20 A
(sp)
25 A
(sp)
30 A
(sp)
15 A
(dp)
25 A
(dp)
Min. recommended
wire size
2
(copper)
14
awg
12
awg
10
awg
10
awg
14
awg
10
awg
Min. water flow to
activate unit
0.21 gpm
(0.8) l/min
0.40 gpm
(1.5) l/min
0.40 gpm
(1.5) l/min
0.40 gpm
(1.5) l/min
0.40 gpm
(1.5) l/min
0.77 gpm
(2.9) l/min
Recommended inlet
temperature range
41–77 °F (525 °C)
Nominal water volume 0.026 gal (0.1 l)
Max. working pressure 150 psi (10 bar)
Tested to pressure 300 psi (20 bar)
Weight 3.44 lb. (1.56 kg)
Height
Depth
Width
6 ½ in. (165 mm)
3 ¼ in. (82 mm)
7 ½ in. (190 mm)
Water connections
3
for
3
/
8
in. O.D. flex connector
Heating system Nichrome bare-wire
AQM 2-1 models are internally restricted to 0.32 GPM / 1.2 l/min.
AQM 2-1, 2.5-1, 3-1 ship with a 0.5 GPM pressure compensating ow-reducer/aerator that must be installed.
AQM 3.5-1, 4-2 ship with a 0.66 GPM pressure compensating ow-reducer/aerator that must be installed.
AQM 6-2 ships with a 1.0 GPM pressure compensating ow-reducer/aerator that must be installed.
1
This is our recommendation for overcurrent protection sized at 100% of load. Check local codes for compliance if necessary.
Tankless water heaters are considered a non-continuous load.
2
Copper must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
3
Suitable for supply with cold water only.
10 | AQM TANKLESS ELECTRIC WATER HEATERS WWW.APTANKLESS.COM
INSTALLATION
TROUBLESHOOTING
1
2 Rear housing
3 Filter screen
4 Plumbing connection (incl. 2 O-rings)
Mini
Tankless Spare Parts List & Diagram
Spare Part No. Model Mini
2-1, 2.5-1, 3-1, 3.5-1, 4-2, 6-2
271010
271011
275981
272777
1
2
3
4
Front cover
13. Spare parts
Spare Part (all AQM models) Item no.
1 Front cover 271010
2 Rear housing 271011
3 Filter screen 272884
4 Plumbing connection 272777
5 O-rings (not shown) 083043
17 West Street
West Hat eld, MA 01088
Toll Free 800.582.2213
Phone 413.247.3380
Fax 413.247.3369
info@aptankless.com
www.aptankless.com
Tankless Electric Domestic Hot Water Heaters
All AQM, AQC, AQE, DHE, & DHE Pro Models
LIMITED WARRANTY
This Warranty is valid for U.S.A. & Canada only. Warranties
may vary by country. Please consult your local AquaPower
Representative for the Warranty for your country.
Subject to the terms and conditions set forth in this
limited warranty, AquaPower (the “Manufacturer”)
hereby warrants to the original purchaser (the “Owner”)
that each Tankless Electric Domestic Hot Water Heater
(the “Heater”) shall not (i) leak due to defects in the
Manufacturer’s materials or workmanship for a period
of  ve (5) years from the date of purchase or (ii) fail
due to defects in the Manufacturers materials or
workmanship for a period of one (1) year from the date
of purchase. As Owners sole and exclusive remedy for
breach of the above warranty, Manufacturer shall, at
the Manufacturer’s discretion, send replacement parts
for local repair; retrieve the unit for factory repair, or
replace the defective Heater with a replacement unit
with comparable operating features. Manufacturer’s
maximum liability under all circumstances shall be
limited to the Owner’s purchase price for the Heater.
This limited warranty shall be the exclusive warranty
made by the Manufacturer and is made in lieu of all
other warranties, express or implied, whether written
or oral, including, but not limited to warranties of
merchantability and  tness for a particular purpose.
Manufacturer shall not be liable for incidental,
consequential or contingent damages or expenses
arising directly or indirectly from any defect in the
Heater or the use of the Heater. Manufacturer shall
not be liable for any water damage or other damage
to property of Owner arising, directly or indirectly,
from any defect in the Heater or the use of the Heater.
Manufacturer alone is authorized to make all warranties
on Manufacturer’s behalf and no statement, warranty
or guarantee made by any other party shall be binding
on Manufacturer.
Manufacturer shall not be liable for any damage
whatsoever relating to or caused by:
1. any misuse or neglect of the Heater, any accident to
the Heater, any alteration of the Heater, or any other
unintended use;
2. acts of God and circumstances over which
Manufacturer has no control;
3. installation of the Heater other than as directed
by Manufacturer and other than in accordance
with applicable building codes;
4. failure to maintain the Heater or to operate the
Heater in accordance with the Manufacturer’s
speci cations;
5. operation of the Heater under  uctuating water
pressure or in the event the Heater is supplied with
non-potable water, for any duration;
6. improper installation and/or improper materials
used by any installer and not relating to defects in
parts or workmanship of Manufacturer;
7. moving the Heater from its original place of
installation;
8. exposure to freezing conditions;
9. water quality issues such as corrosive water, hard
water, and water contaminated with pollutants or
additives;
Should owner wish to return the Heater to
manufacturer for repair or replacement under this
warranty, Owner must  rst secure written authorization
from Manufacturer. Owner shall demonstrate proof
of purchase, including a purchase date, and shall be
responsible for all removal and transportation costs.
If Owner cannot demonstrate a purchase date this
warranty shall be limited to the period beginning
from the date of manufacture stamped on the Heater.
Manufacturer reserves the right to deny warranty
coverage upon Manufacturers examination of Heater.
This warranty is restricted to the Owner and cannot be
assigned.
Some States and Provinces do not allow the exclusion
or limitation of certain warranties. In such cases, the
limitations set forth herein may not apply to the Owner.
In such cases this warranty shall be limited to the
shortest period and lowest damage amounts allowed
by law. This warranty gives you speci c legal rights and
you may also have other rights which vary from State to
State or Province to Province.
Owner shall be responsible for all labor and other
charges incurred in the removal or repair of the Heater
in the  eld. Please also note that the Heater must be
installed in such a manner that if any leak does occur,
the  ow of water from any leak will not damage the
area in which it is installed.
12. Troubleshooting
E
Symptom Possible cause Solution
No hot water
despite fully
opened hot
water faucet.
No electrical power. Check the circuit breaker and check
voltage at the wiring block.
The activation ow rate needed
to turn on the heating element
has not been reached.
Clean lter screen.
Safety cut out tripped turn circuit breakers o
open Hot Valve to release pres-
sure from the unit
reset safety pressure cut out
E
turn circuit breakers on
Safety pressure cut out
ENGLISH
WWW.APTANKLESS.COM AQM TANKLESS ELECTRIC WATER HEATERS | 11
WARRANTY | ENVIRONMENT AND RECYCLING
Environment and recycling
Please help us protect the environment. Dispose of the appliance
and its packaging in accordance with national regulations.
14. Warranty
17 West Street
West Hat eld, MA 01088
Toll Free 800.582.2213
Phone 413.247.3380
Fax 413.247.3369
info@aptankless.com
www.aptankless.com
Tankless Electric Domestic Hot Water Heaters
All AQM, AQC, AQE, DHE, & DHE Pro Models
LIMITED WARRANTY
This Warranty is valid for U.S.A. & Canada only. Warranties
may vary by country. Please consult your local AquaPower
Representative for the Warranty for your country.
Subject to the terms and conditions set forth in this
limited warranty, AquaPower (the “Manufacturer”)
hereby warrants to the original purchaser (the “Owner”)
that each Tankless Electric Domestic Hot Water Heater
(the “Heater”) shall not (i) leak due to defects in the
Manufacturer’s materials or workmanship for a period
of  ve (5) years from the date of purchase or (ii) fail
due to defects in the Manufacturers materials or
workmanship for a period of one (1) year from the date
of purchase. As Owners sole and exclusive remedy for
breach of the above warranty, Manufacturer shall, at
the Manufacturer’s discretion, send replacement parts
for local repair; retrieve the unit for factory repair, or
replace the defective Heater with a replacement unit
with comparable operating features. Manufacturer’s
maximum liability under all circumstances shall be
limited to the Owner’s purchase price for the Heater.
This limited warranty shall be the exclusive warranty
made by the Manufacturer and is made in lieu of all
other warranties, express or implied, whether written
or oral, including, but not limited to warranties of
merchantability and  tness for a particular purpose.
Manufacturer shall not be liable for incidental,
consequential or contingent damages or expenses
arising directly or indirectly from any defect in the
Heater or the use of the Heater. Manufacturer shall
not be liable for any water damage or other damage
to property of Owner arising, directly or indirectly,
from any defect in the Heater or the use of the Heater.
Manufacturer alone is authorized to make all warranties
on Manufacturer’s behalf and no statement, warranty
or guarantee made by any other party shall be binding
on Manufacturer.
Manufacturer shall not be liable for any damage
whatsoever relating to or caused by:
1. any misuse or neglect of the Heater, any accident to
the Heater, any alteration of the Heater, or any other
unintended use;
2. acts of God and circumstances over which
Manufacturer has no control;
3. installation of the Heater other than as directed
by Manufacturer and other than in accordance
with applicable building codes;
4. failure to maintain the Heater or to operate the
Heater in accordance with the Manufacturer’s
speci cations;
5. operation of the Heater under  uctuating water
pressure or in the event the Heater is supplied with
non-potable water, for any duration;
6. improper installation and/or improper materials
used by any installer and not relating to defects in
parts or workmanship of Manufacturer;
7. moving the Heater from its original place of
installation;
8. exposure to freezing conditions;
9. water quality issues such as corrosive water, hard
water, and water contaminated with pollutants or
additives;
Should owner wish to return the Heater to
manufacturer for repair or replacement under this
warranty, Owner must  rst secure written authorization
from Manufacturer. Owner shall demonstrate proof
of purchase, including a purchase date, and shall be
responsible for all removal and transportation costs.
If Owner cannot demonstrate a purchase date this
warranty shall be limited to the period beginning
from the date of manufacture stamped on the Heater.
Manufacturer reserves the right to deny warranty
coverage upon Manufacturers examination of Heater.
This warranty is restricted to the Owner and cannot be
assigned.
Some States and Provinces do not allow the exclusion
or limitation of certain warranties. In such cases, the
limitations set forth herein may not apply to the Owner.
In such cases this warranty shall be limited to the
shortest period and lowest damage amounts allowed
by law. This warranty gives you speci c legal rights and
you may also have other rights which vary from State to
State or Province to Province.
Owner shall be responsible for all labor and other
charges incurred in the removal or repair of the Heater
in the  eld. Please also note that the Heater must be
installed in such a manner that if any leak does occur,
the  ow of water from any leak will not damage the
area in which it is installed.
17 West Street
West Hat eld, MA 01088
Toll Free 800.582.2213
Phone 413.247.3380
Fax 413.247.3369
info@aptankless.com
www.aptankless.com
Tankless Electric Domestic Hot Water Heaters
All AQM, AQC, AQE, DHE, & DHE Pro Models
LIMITED WARRANTY
This Warranty is valid for U.S.A. & Canada only. Warranties
may vary by country. Please consult your local AquaPower
Representative for the Warranty for your country.
Subject to the terms and conditions set forth in this
limited warranty, AquaPower (the “Manufacturer”)
hereby warrants to the original purchaser (the “Owner”)
that each Tankless Electric Domestic Hot Water Heater
(the “Heater”) shall not (i) leak due to defects in the
Manufacturer’s materials or workmanship for a period
of  ve (5) years from the date of purchase or (ii) fail
due to defects in the Manufacturers materials or
workmanship for a period of one (1) year from the date
of purchase. As Owners sole and exclusive remedy for
breach of the above warranty, Manufacturer shall, at
the Manufacturer’s discretion, send replacement parts
for local repair; retrieve the unit for factory repair, or
replace the defective Heater with a replacement unit
with comparable operating features. Manufacturer’s
maximum liability under all circumstances shall be
limited to the Owner’s purchase price for the Heater.
This limited warranty shall be the exclusive warranty
made by the Manufacturer and is made in lieu of all
other warranties, express or implied, whether written
or oral, including, but not limited to warranties of
merchantability and  tness for a particular purpose.
Manufacturer shall not be liable for incidental,
consequential or contingent damages or expenses
arising directly or indirectly from any defect in the
Heater or the use of the Heater. Manufacturer shall
not be liable for any water damage or other damage
to property of Owner arising, directly or indirectly,
from any defect in the Heater or the use of the Heater.
Manufacturer alone is authorized to make all warranties
on Manufacturer’s behalf and no statement, warranty
or guarantee made by any other party shall be binding
on Manufacturer.
Manufacturer shall not be liable for any damage
whatsoever relating to or caused by:
1. any misuse or neglect of the Heater, any accident to
the Heater, any alteration of the Heater, or any other
unintended use;
2. acts of God and circumstances over which
Manufacturer has no control;
3. installation of the Heater other than as directed
by Manufacturer and other than in accordance
with applicable building codes;
4. failure to maintain the Heater or to operate the
Heater in accordance with the Manufacturer’s
speci cations;
5. operation of the Heater under  uctuating water
pressure or in the event the Heater is supplied with
non-potable water, for any duration;
6. improper installation and/or improper materials
used by any installer and not relating to defects in
parts or workmanship of Manufacturer;
7. moving the Heater from its original place of
installation;
8. exposure to freezing conditions;
9. water quality issues such as corrosive water, hard
water, and water contaminated with pollutants or
additives;
Should owner wish to return the Heater to
manufacturer for repair or replacement under this
warranty, Owner must  rst secure written authorization
from Manufacturer. Owner shall demonstrate proof
of purchase, including a purchase date, and shall be
responsible for all removal and transportation costs.
If Owner cannot demonstrate a purchase date this
warranty shall be limited to the period beginning
from the date of manufacture stamped on the Heater.
Manufacturer reserves the right to deny warranty
coverage upon Manufacturers examination of Heater.
This warranty is restricted to the Owner and cannot be
assigned.
Some States and Provinces do not allow the exclusion
or limitation of certain warranties. In such cases, the
limitations set forth herein may not apply to the Owner.
In such cases this warranty shall be limited to the
shortest period and lowest damage amounts allowed
by law. This warranty gives you speci c legal rights and
you may also have other rights which vary from State to
State or Province to Province.
Owner shall be responsible for all labor and other
charges incurred in the removal or repair of the Heater
in the  eld. Please also note that the Heater must be
installed in such a manner that if any leak does occur,
the  ow of water from any leak will not damage the
area in which it is installed.
12 | CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM WWW.APTANKLESS.COM
CONTENIDO | FUNCIONAMIENTO
INFORMACIÓN GENERAL
1. Información general __________________________ 12
1.1 Explicación de símbolos ������������������������ 12
2. Precauciones de seguridad ____________________ 13
3. Registre su producto _________________________ 13
4. Aumento de la temperatura por encima de la
temperatura ambiente del agua _______________ 14
5. Diagramas técnicos __________________________ 14
6. Resumen general ____________________________16
6.1 Descripción general ��������������������������� 16
6.2 Información importante a tener en cuenta antes de
conectar la unidad a la red eléctrica �������������� 16
6.3 Salida de agua caliente ������������������������� 16
6.4 Uso incorrecto �������������������������������� 17
6.5 Primeros pasos a dar en caso de mal funcionamiento 17
6.6 Mantenimiento y cuidado ���������������������� 17
7. Instrucciones de instalación ___________________ 17
7.1 Montaje de la unidad �������������������������� 17
7.2 Conexiones de tuberías ������������������������ 17
7.3 Conexión eléctrica ���������������������������� 18
8. Puesta en marcha inicial ______________________18
9. Traspaso del calentador de agua _______________18
10. Mantenimiento de rutina _____________________ 19
11. Datos técnicos _______________________________ 19
12. Resolución de problemas _____________________20
13. Repuestos __________________________________20
14. Garantía ____________________________________21
1. Información general
Lea este manual en su totalidad. El incumplimiento de alguna
de las pautas, instrucciones o reglas puevde ocasionar lesiones
personales o daños a la propiedad. La inadecuada instalación,
ajuste, alteración, mantenimiento y uso de la unidad puede
resultar en lesiones severas.
Esta unidad debe ser instalada por un electricista y sanitario
autorizado. La instalación debe cumplir con todos los códigos
sanitarios y eléctricos nacionales, estatales y locales. La instalación
adecuada es responsabilidad del instalador. El incumplimiento de
las instrucciones de instalación y operación o el uso inadecuado
invalidan la garantía.
Guarde este instructivo para consultas futuras. El instalador debe
devolverle este instructivo al usuario.
Si tiene cualquier consulta relacionada con la instalación, uso u
operación de este calentador de agua, o si necesita cualquier
manual de instalación adicional, comuníquese por favor con
nuestra línea de servicio técnico a través del 800.582.2213 (solo
para EEUU y Canadá). Si está llamando desde fuera de EEUU y
Canadá, comuníquese por favor con EEUU ++413-247-3380 y
le informaremos sobre un representante calicado del servicio
AquaPower
®
en su zona.
!
Este es el símbolo de alerta de seguridad. Se utiliza
para alertarle sobre potenciales peligros de lesio-
nes personales. Obedezca todos los mensajes de seguridad
que siguen a este símbolo para evitar posibles lesiones o
muerte.
El capítulo Operación está dirigido a dueños de casa, técnicos
en calefacción, sanitarios y electricistas.
El capítulo Instalación está dirigido solamente a técnicos en
calefacción, sanitarios y electricistas.
PELIGRO DE SHOCK ELÉCTRICO
ANTES DE REALIZAR CUALQUIER
TRABAJO SOBRE EL ARTEFACTO,
DESCONECTE TODOS LOS POLOS DE LA RED
ELÉCTRICA.
1
3
4
2
1.1 Explicación de símbolos
1.1.1 Presentación de la información de seguridad
1 Símbolo (vea 1.1.2 "Símbolos", abajo)
2 Palabra clave (Véase la sección 1.1.3, “Palabras clave”, pág.
13)
3 Descripción (ver 1.1.2 "Símbolos", abajo)
4 Texto informativo
1.1.2 Símbolos
Símbolo Descripción
Lesiones
Electrocución
Quemaduras o escaldaduras
!
Otras situaciones
ESPAÑOL
WWW.APTANKLESS.COM CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM | 13
INFORMACIÓN GENERAL
PRECAUCIONES DE SEGURIDAD
1.1.3 Palabras clave
PALABRA CLAVE
PELIGRO
La palabra clave PELIGRO indica
información que debe respetarse, ya que
de lo contrario se producirán lesiones
serias o incluso la muerte.
ADVERTENCIA
La palabra clave ADVERTENCIA indica
información que debe respetarse, ya que
de lo contrario pueden producirse lesiones
serias o incluso la muerte.
PRECAUCIÓN
La palabra clave PRECAUCIÓN indica
información que debe respetarse, ya que
de lo contrario pueden producirse lesiones
serias o incluso la muerte.
2. Precauciones de seguridad
!
POR FAVOR LEA Y SIGA ESTAS INSTRUCCIONES.
EL INCUMPLIMIENTO DE ESTAS INSTRUCCIONES
PUEDE RESULTAR EN LESIONES CORPORALES SEVERAS O
INCLUSO LA MUERTE.
LA UNIDAD DEBE SER INSTALADA POR UN ELECTRICISTA
Y UN SANITARIO AUTORIZADO. LA INSTALACIÓN DEBE
CUMPLIR CON TODOS LOS CÓDIGOS SANITARIOS Y
ELÉCTRICOS NACIONALES, ESTATALES Y LOCALES.
EL MANTENIMIENTO DE LA UNIDAD DEBE SER
REALIZADO POR TÉCNICOS CALIFICADOS.
PELIGRO: ANTES DE REALIZAR CUALQUIER
INSTALACIÓN, AJUSTE, ALTERACIÓN O SERVICIO
DE MANTENIMIENTO DE LA UNIDAD TODOS LOS
DISYUNTORES E INTERRUPTORES DEL CIRCUITO QUE
ALIMENTA LA UNIDAD DEBEN SER DESCONECTADOS. NO
HACERLO PUEDE RESULTAR EN LESIONES PERSONALES
SEVERAS O INCLUSO LA MUERTE.
PELIGRO: TEMPERATURAS DE AGUA
MAYORES A 125 °F 52 °C PUEDEN CAUSAR
QUEMADURAS INSTANTÁNEAS SEVERAS O MUERTE POR
ESCALDADURAS. EXISTE RIESGO DE ESCALDADURA CON
EL AGUA CALIENTE SI SE AJUSTA EL TERMOSTATO A UNA
TEMPERATURA DEMASIADO ELEVADA. LOS HOGARES
CON NIÑOS PEQUEÑOS O PERSONAS DISCAPACITADAS
O DE EDAD AVANZADA PUEDEN REQUERIR QUE EL
TERMOSTATO SE AJUSTE A 120 °F 48 °C O MENOS PARA
PREVENIR POSIBLES LESIONES CON AGUA CALIENTE.
PELIGRO: NUNCA RETIRE LA CUBIERTA DE LA
UNIDAD SIN HABER DESCONECTADO PRIMERO LA
ALIMENTACIÓN ELÉCTRICA DE LA UNIDAD. NO HACERLO
PUEDE RESULTAR EN LESIONES PERSONALES SEVERAS O
INCLUSO LA MUERTE.
ADVERTENCIA: LA UNIDAD DEBE SER
CORRECTAMENTE CONECTADA A TIERRA. NO
CONECTAR LA UNIDAD A TIERRA PUEDE RESULTAR EN
LESIONES PERSONALES SEVERAS O INCLUSO LA MUERTE.
3. Registre su producto
Debe registrar este producto en nuestro sitio
web dentro de los 90 días de la compra para
activar la garantía estándar o para ser elegible para
la garantía extendida. Diríjase a nuestro sitio web en
www.aptankless.com y haga clic en registre su producto
dentro del menú de "Ayuda".
Antes de comenzar el proceso de registro, le sugerimos que
reúna la información necesaria que será la siguiente:
Tipo, por ejemplo: AQM 3-1 [ Mini 3 ] (de la etiqueta blanca
que se encuentra en el lado derecho de la unidad)
Número indicado después de "Nr."
Lugar de compra
Fecha de compra
Nombre y apellido
Dirección de correo electrónico
Dirección física
Número telefónico
Si desea realizar cualquier consulta respecto del proceso
de registro o las opciones de garantía, póngase por fa-
vor en contacto directamente con AquaPower
®
EEUU Al
800.582.2213.
Garantía limitada de responsabilidad:
AquaPower
®
no es responsable por daños a la unidad, daños a
propiedad personal, lesiones corporales o pérdida de la vida
generados por las siguientes situaciones:
- Incumplimiento de estas instrucciones
- Uso incorrecto (calentamiento de cualquier otro líquido que
no sea agua)
- Instalación del artefacto por personas no calicadas
- Modicaciones no autorizadas
- Modicaciones técnicas
- Uso de repuestos no autorizados
La garantía de un año cubre todas las piezas pero no
cubre daños a la unidad como consecuencia de agua dura
Véase la sección 14, “Garantía”, pág. 21 para la garantía
completa. Si está en conocimiento o sospecha que el agua
en su zona es dura (tiene un alto contenido de minerales),
es necesario instalar un dispositivo de ablandamiento de
agua para evitar daños a la unidad AQM.
14 | CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM WWW.APTANKLESS.COM
INFORMACIÓN GENERAL
AUMENTO DE LA TEMPERATURA POR ENCIMA DE LA TEMPERATURA AMBIENTE DEL AGUA
AQM 4-2
3.5 57 50 45 35
AQM 3.5-1
3.5 57 50 45 35
[ °F ]
Flujo mínimo de agua para activar la unidad.
Nota: AQM 2-1 está limitado internamente a 0.32 gpm (1.2 l/min)
AQM 3-1
3.0 49 43 41 30
AQM 2-1
*
1.8 38 – – – – –
Tipo kW GPM
0.32 0.42 0.48 0.5 0.69 0.85 1.06 1.14
AQM 6-2
5.7 – – – – 46 37 34
AQM 2.5-1
2.4 39 34 33 24
1.2 1.6 1.8 2.0 2.6 3.2 4.0 4.3
Tipo kW l/min
[ °C ]
Flujo mínimo de agua para activar la unidad.
Nota: AQM 2-1 está limitado internamente a 1.2 l/min (0.32 gpm)
AQM 3-1
3.0 27 24 22 17
AQM 3.5-1
3.5 31 28 25 19
AQM 2-1
*
1.8 22 – – – – –
AQM 2.5-1
2.4 22 19 17 13
AQM 4-2
3.5 31 28 25 19
AQM 6-2
5.7 – – – – 26 20 19
5 /
5
8
(143 mm)
3
/
16
(4,8 mm)
13
/16 (20 mm)
1/
3
16
(30 mm)
4
¾
(120 mm)
6 ½
(165 mm)
7½” (190 mm) 3¼” (82 mm)
3/8” O.D.
ex connector
3 ¾ (95
mm)
C26�02�05�0009
1
2
4
3
A
4. Aumento de la temperatura por encima de la temperatura ambiente del agua
5. Diagramas técnicos
Leyenda de la gura A
1 Conexión de agua caliente
2 Conexión de agua fría con malla ltrante
3 Malla ltrante
4 Oricios de montaje
15 | CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM WWW.APTANKLESS.COM
INFORMACIÓN GENERAL
DIAGRAMAS TÉCNICOS
C26�02�05�0010
V >
p >
L N
L N GRD
L L GRD
AQM 2-1/2.5-1/3-1/3.5-1
AQM 4-2/6-2
5
6
7
8
9
10
CB
D
Leyenda de la gura C
5
Caja de conexión eléctrica
6 Línea de alimentación de agua para instalación de llave
7 Pileta
8 Llave de agua fría (derecha)
9 Llave de agua caliente (izquierda)
10
Llave de corte
11
Botón de reinicio del limitador de presión de seguridad
FUNCIONAMIENTO
RESUMEN GENERAL
16 | CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM WWW.APTANKLESS.COM
6. Resumen general
6.1 Descripción general
El calentador de agua sin tanque AQM diere de los calentadores
de agua tradicionales de acumulación en varios aspectos. No
almacena agua caliente. En cambio, el agua se calienta en forma
instantánea cuando uye a través de la unidad. Los poderosos
elementos calefactores se activan por un sensor de ujo cuando
se extrae agua de una llave de agua caliente conectada al AQM.
Debido a la ausencia de pérdidas en modo de espera, el AQM
ofrece mayor eciencia energética que los calentadores de agua
de acumulación. La unidad suministrará agua caliente de forma
continua mientras que la llave esté abierta.
La temperatura del agua caliente entregada por el AQM depende
de la potencia del elemento calefactor, la temperatura del
agua fría de entrada y el ujo de agua a través de la unidad.
Para que el AQM funcione correctamente, debe ser ajustado
cuidadosamente a la aplicación que se le va a dar.
Si tiene consultas relacionadas con el modo en que piensa utilizar
el AQM, por favor comuníquese con nuestra línea de servicio
técnico al 800.582.2213 (EEUU y Canadá). Para servicios fuera de
EEUU y Canadá, por favor comuníquese con EEUU 413.247.3380.
También puede comunicarse por correo electrónico a
info@aptankless.com o por fax al 413.247.3369.
El AQM puede ser utilizado para aplicaciones de lavado de manos
en EEUU y Canadá:
- Piletas de baños en instalaciones comerciales/industriales y
hogares
- Cocinas en instalaciones comerciales/industriales y hogares
- Cabañas
- Usos especiales en locales de revelado de fotografías,
laboratorios, etc.
El AQM también puede ser utilizado para apartamentos
completos y casas en zonas de clima cálido como la región del
Caribe, América Central y México, debido a que se registran
temperaturas ambiente del agua superiores.
Este manual debe ser leído cuidadosamente antes de intentar instalar el calentador de agua aqm. Si ud no sigue las
normas de seguridad o las instrucciones descritas en este manual, la unidad puede no operar adecuadamente y puede
ocasionar daños a la propiedad, lesiones corporales severas y/o la muerte.
AquaPower
®
no será responsable por cualquier daño ocasionado por el incumplimiento de las instrucciones de instalación
y operación descritas en este manual o por uso inadecuado. Como uso inadecuado se incluye el uso de este artefacto para
calentar cualquier otro líquido que no sea agua. El incumplimiento de las instrucciones de instalación y operación o el uso
inadecuado invalidan la garantía. Nunca retire la cubierta de la unidad sin haber desconectado primero la electricidad.
Si tiene cualquier consulta relacionada con la instalación u operación de este calentador de agua, o si necesita cualquier
manual de instalación adicional, comuníquese por favor con nuestra línea de servicio técnico a través del 800.582.2213
(Solo para EEUU Y Canadá). Si está llamando desde fuera de EEUU Y Canadá, comuníquese por favor con EEUU 413.247.3380
Y le informaremos sobre un representante calicado del servicio AquaPower
®
en su zona.
6.2 Información importante a tener en cuenta
antes de conectar la unidad a la red eléctrica
La presencia de aire en la cañería de agua fría des-
truirá el sistema calefactor de alambre desnudo
del AQM. Si se ha interrumpido la alimentación de agua al
AQM, por ejemplo debido a riesgos de formación de escar-
cha o a trabajos en la cañería de agua, se deben ejecutar
los siguientes pasos antes de volver a utilizar la unidad:
» 1. Desconecte el disyuntor del circuito.
» 2. Abra una llave de agua caliente ubicada a continuación
de la unidad durante el tiempo necesario para que la unidad
y la cañería de agua fría queden libres de aire.
» 3. Conecte el disyuntor del circuito.
Toda la información contenida en estas Instrucciones de Uso
debe ser seguida cuidadosamente. Las Instrucciones de Uso
brindan información importante en relación a la seguridad,
operación, instalación y mantenimiento de la unidad.
6.3 Salida de agua caliente
Modelo Potencia a voltaje
nominal máxima
Salida de agua
caliente típica
AQM 2-1 1.8 kW 0.32 gpm / 1.2 l/min
AQM 2.5-1 2.4 kW 0.50 gpm / 1.9 l/min
AQM 3-1 3.0 kW 0.50 gpm / 1.9 l/min
AQM 3.5-1 3.5 kW 0.66 gpm / 2.5 l/min
AQM 4-2 3.5 kW 0.66 gpm / 2.5 l/min
AQM 6-2 5.7 kW 1.00 gpm / 3.8 l/min
Modelo AQM 2-1 está limitado internamente a 0.32 gpm (1.3 l /
min). Modelos AQM 2-1, 2.5-1, 3-1 se suministran con una presión
de 0.5 gpm (1.9 l / min) compensar reductor de ujo / aireador
que se debe instalar. Modelos AQM 3.5-1, 4-2 se suministran con
una presión de 0.66 gpm (2.5 l / min) compensar reductor de ujo
/ aireador que se debe instalar.
ESPAÑOL
WWW.APTANKLESS.COM CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM | 17
INSTALACIÓN
INSTRUCCIONES DE INSTALACIÓN
6.4 Uso incorrecto
No están permitidas e invalidarán la garantía de fábrica:
- La instalación del artefacto donde exista riesgo de
formación de escarcha
- La instalación en habitaciones donde el artefacto esté en
riesgo de explosión como resultados de polvos, gases o
vapores
- Ignorar las holguras y zonas de seguridad
- La conexión eléctrica incorrecta
- La operación del artefacto sin que uya agua por la unidad,
o con aire en las cañerías (Véase la sección 8, “Puesta en
marcha inicial”, pág. 18)
- La operación de la unidad sin tener colocada la cubierta
- Calentar líquidos diferentes del agua potable
6.5 Primeros pasos a dar en caso de mal
funcionamiento
ADVERTENCIA: Siempre desconecte la energía eléc-
trica y el agua de la unidad antes de retirar la malla
ltrante. No hacerlo puede resultar en lesiones personales
severas o incluso la muerte.
» Revise el disyuntor
» Revise la malla ltrante para detectar el bloqueo por
incrustaciones o la acumulación de suciedad. Véase la
sección 12, “Resolución de problemas”, pág. 20.
6.6 Mantenimiento y cuidado
!
El trabajo de mantenimiento, tal como comprobar
la seguridad eléctrica, solo puede ser realizado por
un instalador calicado.
ADVERTENCIA: Siempre desconecte la energía eléc-
trica y el agua de la unidad antes de retirar la malla
ltrante. No hacerlo puede resultar en lesiones personales
severas o incluso la muerte.
Periódicamente limpie y elimine las incrustaciones de la malla
ltrante ubicada en la conexión de entrada de agua fría, y si es
necesario reemplácela. Siempre desconecte la energía eléctrica
y el agua de la unidad antes de retirar la malla ltrante.
Para limpiar la carcasa de la unidad es suciente utilizar un
paño húmedo. No utilice ningún agente de limpieza abrasivo
o corrosivo.
7. Instrucciones de instalación
Guarde estas instrucciones cuidadosamente y en-
trégueselas a su sucesor en caso de ocurrir un cam-
bio en la propiedad; si se debe realizar mantenimiento o un
posible trabajo de reparación, estas instrucciones deben
ser entregadas al instalador calicado para su consulta.
7.1 Montaje de la unidad
!
LA UNIDAD SOLAMENTE DEBE SER MONTADA CON
LAS CONEXIONES SANITARIAS APUNTANDO HACIA
ARRIBA O HACIA ABAJO.
ADVERTENCIA: NO INSTALE LA UNIDAD EN UN LU-
GAR DONDE PUEDA SER SALPICADA A MENUDO
CON AGUA. PUEDE RESULTAR EN SHOCK ELÉCTRICO O IN-
CLUSO MUERTE.
» 1. Instale el AQM tan cerca como sea posible del
punto donde se extraerá el agua caliente, por ejemplo
directamente debajo de la pileta o junto al duchero.
» 2. Instale el AQM en una zona libre de escarcha. Si se
formase escarcha, retire la unidad antes que se alcance la
temperatura de congelación.
» 3. Deje una holgura mínima de 13 cm en todas las caras
para realizar el mantenimiento.
» 4. Para retirar la cubierta de plástico desenrosque los
tornillos ubicados en el lado izquierdo y el lado derecho de
la unidad
B
.
» 5. Retire el panel trasero de plástico tirando de la lengüeta
con un destornillador
B
.
» 6. Asegure el panel trasero a la pared colocando dos
tornillos a través de los oricios de
montaje
A B
.
» 7. Vuelva a encajar la unidad sobre el panel de montaje
B
.
» 8. Vuelva a colocar la cubierta sujetándola con los tornillos
ubicados en el lado izquierdo y el lado derecho de la unidad
B
.
7.2 Conexiones de tuberías
Nota: si fuera necesario soldar cerca de la unidad,
por favor dirija la llama lejos de la carcasa de la uni-
dad para evitar daños. El calor excesivo ocasionado por sol-
dar cañerías de cobre cerca del aqm puede causar daños.
Todo el trabajo plomería debe cumplir con los códigos de
plomería nacionales, estatales y locales aplicables.
» 1. Todo el trabajo plomería debe cumplir con los códigos de
plomería nacionales, estatales y locales aplicables.
18 | CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM WWW.APTANKLESS.COM
INSTALACIÓN
PUESTA EN MARCHA INICIAL
» 2. Si la presión de la alimentación de agua fría supera los
1,034 MPa (150 psi o 10 bar) se debe instalar una válvula
reductora de presión.
» 3. Asegúrese que la línea de alimentación de agua fría
ha sido enjuagada para retirar cualquier incrustación o
suciedad.
» 4. Instale una llave de paso en la cañería de agua fría tal
como se muestra en la ilustración
C
Esto permite aislar la
unidad para propósitos de mantenimiento.
» 5. La conexión de agua fría (entrada) se encuentra del lado
derecho de la unidad, la conexión de agua caliente (salida)
se encuentra del lado izquierdo de la unidad.
» 6. Los calentadores de agua sin tanque, tal como el AQM,
no requieren estar equipados con una válvula de alivio
de presión y temperatura (salvo en Massachusetts). Si el
inspector local no aprueba la instalación sin una válvula de
presión y temperatura, la misma debe ser instalada del lado
de la unidad donde se encuentra la salida de agua caliente.
» 7. El AQM está diseñado para ser conectado con una
manguera trenzada de acero inoxidable con un diámetro
exterior del tubo de salida de 7,6 cm (3/8").
» 8. Cuando se haya completado todo el trabajo de sanitaria,
compruebe que no existen pérdidas y tome medidas
correctivas antes de proceder.
7.3 Conexión eléctrica
ADVERTENCIA: ANTES DE COMENZAR CUALQUIER
TRABAJO DE INSTALACIÓN ELÉCTRICA, ASEGÚ
RESE QUE EL INTERRUPTOR DEL PANEL DEL CIRCUITO
DISYUNTOR PRINCIPAL ESTÉ EN POSICIÓN "OFF" PARA
EVITAR PELIGRO DE SHOCK ELÉCTRICO. NO HACERLO
PUEDE RESULTAR EN LESIONES PERSONALES SEVERAS O
INCLUSO LA MUERTE. TODO EL MONTAJE E INSTALACIÓN
SANITARIA DEBE COMPLETARSE ANTES DE PROCEDER A
LA CONEXN ELÉCTRICA. CUANDO LO REQUIERAN LOS
CÓDIGOS LOCALES, ESTATALES O NACIONALES, EL CIR
CUITO DEBE ESTAR EQUIPADO CON UN INTERRUPTOR DE
FALLA A TIERRA.
ADVERTENCIA: COMO CON CUALQUIER ARTEFACTO
ELÉCTRICO, LA NO CONEXIÓN DE LA UNIDAD A TIERRA
PUEDE RESULTAR EN LESIONES SEVERAS O INCLUSO LA
MUERTE.
PRECAUCIÓN: LA INSTALACIÓN DE UN AQM 21, AQM
2.51, AQM 31, O AQM 3.51 EN UN CIRCUITO DE 208 V O
220 240 V DESTRUIRÁ EL ELEMENTO CALEFACTOR. ÉSTO
SE CONSIDERA INSTALACIÓN INDEBIDA E INVALIDARÁ
SU GARANTÍA DE FÁBRICA.
Voltaje
AQM 2-1: 110120 V
AQM 2.5-1: 110120 V
AQM 3-1: 110120 V
AQM 3.5-1: 110120 V
AQM 4-2: 220240 V, 208 V
AQM 6-2: 220240 V, 208 V
1. Todo el trabajo eléctrico debe cumplir con los códigos
sanitarios nacionales, estatales y locales aplicables.
2. El AQM debe ser conectado a un ramal dedicado del circuito
con una conexión a tierra adecuada y el voltaje apropiado. En
instalaciones con varias unidades AQM, cada unidad requiere
un circuito independiente. Por favor consulte la tabla de datos
técnicos para conocer el dimensionado correcto de los cables y
el disyuntor.
3. Vuelva a colocar la cubierta plástica.
8. Puesta en marcha inicial
!
ADVERTENCIA: ABRA LA LLAVE DE AGUA CALIEN-
TE POR UNOS MINUTOS HASTA QUE EL FLUJO DE
AGUA SEA CONTINUO Y TODO EL AIRE HAYA SIDO PURGA-
DO DE LAS CAÑERÍAS DE AGUA. LA CUBIERTA PLÁSTICA DE
LA UNIDAD DEBE SER INSTALADA ANTES DE CONECTAR EL
DISYUNTOR DEL CIRCUITO.
26�02�02�0436
2
1
press
on
on
e
le
c
tro
n
ic
°C
2.
electronic
°C
electronic
°C
1.
electronic
°C
X1
press
on
on
e
le
c
tro
n
ic
°C
2.
electronic
°C
electronic
°C
1.
electronic
°C
X1
9. Traspaso del calentador de agua
Explique las funciones de la unidad al usuario y haga que se
familiarice con su uso. Instrucciones importantes:
» Advierta al usuario de posibles peligros (escaldaduras).
» Entréguele este instructivo para consultas futuras.
» Para obtener una temperatura adecuada en la salida de una
llave única tipo mezcladora, restrinja el ujo de agua fría a la
llave cerrando parcialmente la válvula de corte del agua fría
ubicada debajo de la pileta, hasta que los ujos de agua fría
y caliente sean aproximadamente iguales.
ESPAÑOL
WWW.APTANKLESS.COM CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM | 19
INSTALACIÓN
MANTENIMIENTO DE RUTINA
10. Mantenimiento de rutina
!
PRECAUCIÓN: SALVO EL TAMIZ FILTRANTE, EL AQM
NO POSEE NINGUNA PARTE QUE PUEDA SER MAN-
TENIDA POR UNA PERSONA NO ESPECIALIZADA. EN CASO
DE MAL FUNCIONAMIENTO, POR FAVOR CONTACTE A UN
SANITARIO O ELECTRICISTA AUTORIZADO.
Los calentadores de agua sin tanque AQM de AquaPower
®
están diseñados para una larga vida útil. La expectativa de vida real variará
con la calidad del agua y el uso. La unidad en sí misma no requiere ningún mantenimiento periódico. Sin embargo, para asegurar un
ujo de agua uniforme, se recomienda remover periódicamente las incrustaciones y la suciedad que puede depositarse en el aireador
de la llave o en el cabezal de la ducha. El AQM también tiene incorporado un tamiz ltrante que debe limpiarse de tanto en tanto.
Para hacer esto, corte la alimentación de agua fría con la llave de paso. Limpie el tamiz y vuelva a colocarlo en su posición original.
11. Datos técnicos
AQM
2-1 AQM
2.5-1 AQM
3-1 AQM
3.5-1 AQM
4-2 AQM
6-2
Número de artículo
231045 232098 220816 232099 222039 220817
Fase 1 1 1 1 1 1
Voltaje 110120 V 110120 V 110120 V 110120 V 220–240 V 208 V 220–240 V 208 V
Potencia 1.8 kW 2.4 kW 3.0 kW 3.5 kW 3.5 kW 2.6 kW 5.7 kW 4.3 kW
Corriente máx., carga 15 A 20 A 25 A 29 A 14.6 A 12.7 A 23.8 A 20.6 A
Interruptor auto. #
requerido
1
15 A (1p)
20 A (1p)
25 A (1p)
30 A (1p)
15 A (2p)
25 A (2p)
Tamaño requerido de
cable
2
(cobre)
14
awg
12
awg
10
awg
10
awg
14
awg
10
awg
Flujo mínimo de agua
para activar la unidad
0.21 gpm
(0.8) l/min
0.40 gpm
(1.5) l/min
0.40 gpm
(1.5) l/min
0.40 gpm
(1.5) l/min
0.40 gpm
(1.5) l/min
0.77 gpm
(2.9) l/min
Rango de temperatura de
entrada recomendado
41–77 °F (525 °C)
Volumen nominal
de agua
0.026 gal (0.1 l)
Presión de trabajo, máx. 150 psi (10 bar)
Probado hasta una
presión de
300 psi (20 bar)
Peso 3.44 lb. (1.56 kg)
Altura
Profundidad
Ancho
6 ½ in. (165 mm)
3 ¼ in. (82 mm)
7 ½ in. (190 mm)
Conexiones de agua
3
una manguera trenzada de acero inoxidable con un diámetro exterior del tubo de
salida de
3
/
8
pulg. (76 mm).
Sistema calefactor Cable desnudo de Nicromo
Modelo AQM 2-1 está limitado internamente a 0.32 gpm (1.2 l / min).
Modelos AQM 2-1, 2.5-1, 3-1 se suministran con una presión de 0.5 gpm (1.9 l / min) compensar reductor de ujo / aireador que se debe instalar.
Modelos AQM 3.5-1, 4-2 se suministran con una presión de 0.66 gpm (2.5 l / min) compensar reductor de ujo / aireador que se debe instalar.
Modelos AQM 6-2 se suministran con una presión de 1.0 gpm (3.8 l / min) compensar reductor de ujo / aireador que se debe instalar.
1
Esta es nuestra recomendación por sobre la protección actual de tamaño al 100% de la carga. Compruebe normativa local si es necesario.
Los calentadores sin tanque eléctricos son considerados una carga no continua.
2
Los conductores deben ser dimensionados para mantener una caída de tensión de menos del 3 % en situación de carga
3
Los equipos están apropiados solo para ser alimentados con agua fría.
20 | CALENTADORES DE AGUA ELÉCTRICOS SIN TANQUE AQM WWW.APTANKLESS.COM
INSTALACIÓN
RESOLUCIÓN DE PROBLEMAS
1
2 Rear housing
3 Filter screen
4 Plumbing connection (incl. 2 O-rings)
Mini
Tankless Spare Parts List & Diagram
Spare Part No. Model Mini
2-1, 2.5-1, 3-1, 3.5-1, 4-2, 6-2
271010
271011
275981
272777
1
2
3
4
Front cover
13. Repuestos
Repuesto (todos los modelos Mini™)
1 Cubierta frontal 271010
2 Cubierta trasera 271011
3 Malla ltrante 272884
4 Conexiones de agua 272777
5 Junta circular (no se muestra aquí) 083043
12. Resolución de problemas
E
Síntoma Causa posible Solución
No sale agua
caliente a
pesar que la
llave de agua
caliente está
completa-
mente abier-
ta.
Sin energía eléctrica. Verique el disyuntor del cir-
cuito y compruebe el voltaje
en el bloque de conexiones.
No se ha alcanzado el ujo de acti-
vación requerido para encender el
elemento calefactor.
Limpie la malla ltrante.
Se activó el limitador de seguridad desconecte los disyuntores
del circuito
abra la llave caliente para
liberar presión de la unidad
reinicie el limitador de segu-
ridad de presión
E
conecte los disyuntores del
circuito
Limitador de presión
de seguridad
17 West Street
West Hat eld, MA 01088
Toll Free 800.582.2213
Phone 413.247.3380
Fax 413.247.3369
info@aptankless.com
www.aptankless.com
GARANTÍA LIMITADA
Sujeto a los términos y condiciones expresados en
esta Garantía Limitada de por vida, AquaPower (el
“Fabricante”) por la presente asegura al comprador
original (el “Propietario”) que cada calentador de
agua eléctrico de calor sin tanque (el “Calentador)
no deberá (i) tener fugas debido a defectos en los
materiales del fabricante o mano de obra por un período
de cinco (5) años desde la fecha de compra o (ii) falla
debido a defectos en los materiales o mano de obra
del fabricante por un período de un (1) año a partir de
la fecha de compra. Como única y exclusiva solución
para el Propietario en cuanto a la presente garantía,
el Fabricante, a discreción del Fabricante, reparará en
fábrica o reemplazará el Calentador defectuoso con una
unidad o repuesto de reemplazo con características de
funcionamiento comparables. La máxima responsabilidad
del Fabricante en cualquier circunstancia se limitará al
precio de compra del Calentador que pagó el Propietario.
Esta garantía limitada será la garantía exclusiva que el
Fabricante otorga, y reemplaza todas las demás garantías,
expresas o implícitas, escritas u orales, que incluyen
pero no se limitan a las garantías de comerciabilidad o
adecuación para un  n determinado. El Fabricante no
será responsable de daños incidentales, indirectos o
contingentes o gastos que surjan, de manera directa
o indirecta, de cualquier defecto del Calentador o del
uso del mismo. El Fabricante no será responsable por
daños ocasionados por el agua o cualquier otro daño a la
propiedad del Propietario que surja, de manera directa o
indirecta, de cualquier defecto del Calentador o del uso
del mismo. Solo el Fabricante está autorizado a conceder
todas las garantías en representación del Fabricante, y
ninguna declaración o garantía realizada por cualquier
otra parte será vinculante para el Fabricante.
El Fabricante no será responsable de ningún daño
relacionado o causado por:
1. cualquier uso indebido o falta de cuidado del
Calentador, cualquier accidente que afecte al
Calentador, cualquier alteración al Calentador, o
cualquier otro uso incorrecto;
2. casos fortuitos o circunstancias sobre las cuales el
Fabricante no tiene control;
3. instalación del Calentador que se desvíe de las
directivas del Fabricante o no observe los códigos
de construcción pertinentes;
4. negligencia en cuanto a mantener el Calentador u
operar el Calentador según las especi caciones del
Fabricante;
5. hacer funcionar el Calentador en condiciones de
presión de agua  uctuante o en caso de que el
Calentador se alimente de agua no potable durante un
período de cualquier duración;
6. instalación defectuosa y/o uso de materiales
inapropiados por parte de cualquier instalador y que
no se relacione con defectos en los repuestos o la
mano de obra del Fabricante;
7. mover el Calentador de su lugar original de instalación;
8. exposición a condiciones de congelamiento;
9. los problemas de calidad del agua, como el agua
corrosiva, el agua dura y agua contaminada con
contaminantes o aditivos;
Si el Propietario desea devolver el Calentador al Fabricante
para su reparación o reemplazo bajo esta garantía, el
Propietario debe obtener primero la autorización por
escrito del Fabricante. El Propietario deberá presentar una
prueba de compra, incluida la fecha de compra, y será
responsable de los costos de desinstalación y transporte.
Si el Propietario no puede demostrar una fecha de
compra, esta garantía se limitará al período que comienza
a partir de la fecha de compra impresa en el Calentador.
El Fabricante se reserva el derecho de negar la cobertura
de esta garantía después de examinar el Calentador. Esta
garantía se limita al Propietario y es intransferible.
Algunos Estados y Provincias no permiten la exclusión
o limitación de ciertas Garantías. En dichos casos, las
limitaciones aquí expresadas pueden no aplicarse al
Propietario. En dichos casos esta Garantía se limitará
al período más corto y las menores cifras de daños
permitidas por ley. Esta Garantía le da derechos legales
especí cos y puede que usted tenga otros derechos que
variarán de Estado a Estado y de Provincia a Provincia.
El Propietario será responsable de todos los costos
de mano de obra y otros cargos incurridos al retirar o
reparar el Calentador en el lugar de instalación. Por
favor obsérvese que el Calentador debe instalarse de tal
manera que, en caso de pérdida, el  ujo de agua de la
pérdida no dañe el lugar en que está instalado.
Esta Garantía solo es válida en Estados Unidos y Canadá.
Las garantías pueden variar de un país a otro. Consulte
a su representante de AquaPower local para conocer la
Garantía correspondiente a su país.
Calentadores de Agua Eléctricos Sin Tanque
Todos los modelos AQM, AQC, AQE, DHE, y DHE Pro
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

AquaPower AQM 3-1 Operation and Installation

Taper
Operation and Installation
Ce manuel convient également à

dans d''autres langues