Whirlpool WGD5000DW1 Guide d'installation

Catégorie
Sèche-linge
Taper
Guide d'installation
DRYER iNSTALLATiON iNSTRUCTiONS
29" and 27" Wide Models
Gas (U.S.A. and Canada} & Electric (Canada Only)
iNSTRUCTiONS D'INSTALLATION DE LA SECHEUSE
ModUles de 29" et de 27" de iargeur
A gaz (E.-U. et Canada) et I_lectrique (Canada uniquement)
Para obtener acceso al manual de uso y cuidado en espa_ol, o para obtener informaci6n adicional acerca de su producto, visite:
www.whirlpool.com
Tenga listo su nOmero de modelo completo. Puede encontrar el nOmero de modelo y de serie dentro de la cavidad superior de la puerta.
Table of Contents Table des mati_res
DRYER SAFETY ................................................................ 2
INSTALLATION REQUIREMENTS .................................... 4
Tools and Parts .................................................................... 4
Location Requirements ...................................................... 4
ELECTRIC DRYER POWER HOOKUP - CANADA ONLY ......... 6
Electrical Requirements ..................................................... 6
install Leveling Legs ........................................................... 7
GAS DRYER POWER HOOKUP ................................................. 7
Gas Supply Requirements .................................................. 7
Electrical Requirements ..................................................... 9
VENTING ...................................................................................... 9
Venting Requirements ......................................................... 9
Plan Vent System ............................................................... 10
Venting Kits ........................................................................ 11
Install Vent System ............................................................ 12
Make Gas Connection ...................................................... 12
Connect Vent ..................................................................... 13
LEVEL DRYER ........................................................................... 13
COMPLETE iNSTALLATiON CHECKLIST ............................... 13
REVERSE DOOR SWING (OPTIONAL) .................................... 14
TROUBLESHOOTING ............................................................... 21
SECURIT¢:: DE LA S¢:CHEUSE ....................................... 22
EXIGENCES D'INSTALLATION ...................................... 24
Outillage et pi_ces ............................................................ 24
E×igences d'emplacement ............................................... 25
RACCORDEMENT A L'ALIMENTATION leLECTRIQUE
DE LA SI'==CHEUSE#LECTRIQUE - CANADA SEULEMENT ... 27
Specifications _lectriques ................................................ 27
installation des pieds de nivellement .............................. 28
RACCORDEMENT D'UNE S(-=CHEUSE A GAZ ....................... 28
Specifications de I'alimentation en gaz .......................... 28
Specifications _lectriques ................................................ 30
UleVACUATION .......................................................................... 30
E×igences concernant I'_vacuation ................................ 30
Planification du syst_me d'_vacuation ........................... 31
Trousses d'6vacuation ...................................................... 32
installation du circuit d'_vacuation ................................. 33
Raccordement au gaz ....................................................... 34
Raccordement du conduit d'6vacuation ......................... 34
REGLAGE DE L'APLOMB DE LA SECHEUSE ......................... 35
ACHEVER L'INSTALLATION - LISTE DE VERIFICATION ....... 35
INVERSION DU SENS DE L'OUVERTURE DE LA PORTE
(FACULTATIF) ............................................................................. 36
DEPANNAGE ............................................................................. 43
iNSTALLATiON NOTES
Date of purchase:
Date of installation:
Installer:
Model number:
Serial number:
NOTES CONCERNANT L'INSTALLATION
Date d'achat :
Date d'installation :
Installateur :
Num_ro de module :
Num_ro de s_rie :
W10562360A
W10562361A=SP
DRYER SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
WARNING - ...i.. of
= Clothes dryer installation must be performed by a qualified installer,
- Install the clothes dryer according to the manufacturer's instructions and local codes.
= Do not install a clothes dryer with fle×ible plastic venting materials or fle×ible metal
(foil type) duct. if fle×ible metal duct is installed, it must be of a specific type identified
by the appliance manufacturer as suitable for use with clothes dryers. Fle×ible venting
materials are known to collapse, be easily crushed, and trap lint. These conditions will
obstruct clothes dryer airflow and increase the risk of fire.
= To reduce the risk of severe injury or death, follow all installation instructions.
= Save these instructions.
iMPORTANT: The gas installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
The dryer must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA C22.1.
State of California Proposition 65 Warnings:
WARNING: This product contains one or more chemicals known to the State of California to cause cancer.
WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other
reproductive harm.
2
In the State of Massachusetts, the following installation instructions apply:
[] InstaHlationsand repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
[] If using a ball valve, it shall be a T=handle type.
[] A flexible gas connector, when used, must not exceed 3 feet.
WARNING: For your safety, the information in this manual must be followed to minimize
the risk of fire or explosion, or to prevent property damage, personal injury, or death.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
- WHAT TO DO iF YOU SMELL GAS:
= Do not try to light any appliance.
® Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building, or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
if you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or
the gas supplier.
WARNING: Gas leaks cannot always be detected by smell.
Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the "What to do if you smell gas" instructions.
IMPORTANT SAFETY iNSTRUCTIONS
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions,
including the following:
[] Read all instructions before using the dryer.
[] Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to
a chemical reaction that could cause a load to catch fire.
[] Do not dry articles that have been previously cleaned in,
washed in, soaked in, or spotted with gasoline, dry-
cleaning solvents, or other flammable or explosive
substances as they give off vapors that could ignite or
explode.
[] Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
[] Before the dryer is removed from service or discarded,
remove the door to the drying compartment.
[] Do not reach into the dryer if the drum is moving.
[] Do not install or store the dryer where it will be exposed
to the weather.
[] Do not tamper with controls.
[] Do not repair or replace any part of the dryer or attempt
any servicing unless specifically recommended in this
Use and Care Guide or in published user=repair
instructions that you understand and have the skills to
carry out.
[] Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
[] Do not use heat to dry articles containing foam rubber or
similarly textured rubber=like materials.
[] Clean lint screen before or after each load.
[] Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint, dust,
and dirt.
[] The interior of the dryer and exhaust vent should be
cleaned periodically by qualified service personnel.
[] See "Electrical Requirements" located in the installation
instructions for grounding instructions.
SAVE THESE iNSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
When discarding or storing your old clothes dryer, remove the door.
SAVE THESE iNSTRUCTIONS
iNSTALLATiON REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Tools needed for all installations:
Tools needed for gas installations:
8" or 10" pipe wrench 8" or 10" adjustable wrench
(for gas connections)
Flat-blade screwdriver
#2 Phillips screwdriver
1/4" nut driver or socket
wrench (recommended)
Tape measure
Level Pliers
Adjustable wrench that
opens to 1" (25 mm) or
hex-head socket wrench
Utility knife
Tin snips (new vent
installations)
Vent clamps
Caulking gun and
compound (for installing
new exhaust vent)
Putty knife
Pipe-joint compound
resistant to LP gas
Parts supplied:
Leveling legs (4)
Parts package is located in dryer drum. Check that all parts
are included.
Parts needed:
Check local codes. Check existing electrical supply and venting.
See "Electrical Requirements" and "Venting Requirements"
before purchasing parts.
Check code requirements. Some codes limit, or do not permit,
installing dryer in garages, closets, mobile homes, or sleeping
quarters. Contact your local building inspector.
Optional Equipment: (Not supplied with dryer)
Refer to your "Use and Care Guide" for information about
accessories available for your dryer.
Location Requirements
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least !8 inches (460 ram) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
4
You will need:
[] A location allowing for proper exhaust installation.
See "Venting Requirements."
[] Aseparate30ampcircuitforelectricdryers.
[] Aseparate15or20ampcircuitforgasdryers.
[] Ifyouareusingpowersupplycord,agroundedelectrical
outletlocatedwithin2ft.(610mm)ofeithersideofdryer.
See"ElectricalRequirements."
[] Asturdyfloortosupportdryerandatotalweight(dryer
andload)of200Ibs.(90.7kg).Thecombinedweightofa
companionapplianceshouldalsobeconsidered.
[] Levelfloorwithmaximumslopeof1"(25mm)underentire
dryer.If slope is greater than 1" (25 mm), install Extended
Dryer Feet Kit, Part Number 279810. If not level, clothes
may not tumble properly and automatic sensor cycles may
not operate correctly.
Do not operate your dryer at temperatures below 45°F (7°C).
At lower temperatures, the dryer might not shut off at the end
of an automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the
same closet as a dryer.
installation clearances:
The location must be large enough to allow the dryer door to
open fully.
Most installations require a minimum 51/2'' (140 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
29" Wide Models
Dryer Dimensions
29"
(737 rnm)
43
110; ram)
V
?
1/2H
(13 ram}
-,,--- 29" -_
(737 ram) I
433/8 ''
(1102ram)
{ II
u u ___
1V2'
(38ram)
NOTE: Leveling legs should be 1/2" (13 mm) (to match height of
3.6 cu. ft. capacity washer) or 11/2"(38 mm) (to match height of
3.8 cu. ft. capacity washer).
133/4"
(34grnrn)
223/4.-.__ 273/4.--_ _ -.,P----273/4.--_
(578 ram) (705 ram) _ (705 ram)
f _ /2_
A
A, Wide opening side-swing door
B. Wide opening hamper door
installation Spacing
d11
18"* °l°
(457m_l __
1,,-_i_- 29,,-_ i<- 1,,
(25rnrn)(737ram)
A
_ _ (31Ocm)_
24in.2.-
-. _ (l_scrn)_
-H_"*F273_,,H5,/_"I_
(25rnm)(25ram}(705rnrn}(140ram)
B C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
27" Wide Models
Dryer Dimensions
27"
(686 ram)
223/4 ''
(578 ram)
--f
43"
(1092 ram)
1V2"
(38 ram}
133/4 ''
(349ram)
291/2"
(749 ram)
J_
291/2 ''
(749mm)
1
A B
A, Wideopening side-swing door
B. Wideopening hamper door
Installation Spacing
[_ _ II_ mm_48in'_
(310®)_
Q 24i_*,
"-_ E:_ (155cml
1"--)t J_- 27"-_ I_-1" -'_l"*_<'-2gY2"_5y2"*}'_"
(25rnm) (686mrn) (25mrn)_5mm}(749mrn}(140rnm}
A B
*Required spacing
C
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
3]1,
(76ram)
i_ 3"*
(76rnm)
--f
j._ 3"*
(76ram)
?
Installation spacing for recessed area or c(oset
The dimensions shown are for the minimum spacing allowed.
[] Additional spacing should be considered for ease of
installation and servicing.
[] Additional clearances might be required for wall, door, and
floor moldings.
[] Additional spacing of 1" (25 mm) on all sides of the dryer is
recommended to reduce noise transfer.
[] For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
[] Companion appliance spacing should also be considered.
Mobile home = Additional installation requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280) or the Canadian
Manufactured Home Standard CAN/CSA-Z240 MH.
[] Metal exhaust system hardware, available for purchase.
For further information, please reference the "Assistance
or Service" section of the "Use and Care Guide."
[] Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such
as a nearby window) should be at least twice as large
as the dryer exhaust opening.
ELECTRIC DRYER POWER
HOOKUP - CANADA ONLY
Electrical Requirements
"a,
Electrical Shock Hazard
Plug into a grounded 4 prong out(et.
Failure to do so can result in death or electrical shock.
[]
This dryer is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-30R
wall receptacle. The cord is 5 ft. (1.52 m) in length. Be sure
wall receptacle is within reach of dryer's final location.
4-wire receptacle (14-30R)
[] Do not use an extension cord.
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 8579325.
For further information, please reference the "Assistance or
Service" section of the "Use and Care Guide."
GROUNDING INSTRUCTIONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
(t is your responsibility:
[] To contact a qualified electrical installer.
[] To be sure that the electrical connection is adequate
and in conformance with the Canadian Electrical Code,
C22.1 -latest edition and all local codes. A copy of the
above codes standard may be obtained from: Canadian
Standards Association, 178 Rexdale Blvd., Toronto, ON
M9W 1R3 CANADA.
[] To supply the required 4 wire, single phase, 120/240 volt,
60 Hz., AC only electrical supply on a separate 30-amp
circuit, fused on both sides of the line. A time-delay fuse or
circuit breaker is recommended. Connect to an individual
branch circuit.
6
Install Leveling Legs
Excessive Weight Hazard
Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.
1, Prepare dryer for leveling legs
\
To avoid damaging floor, use a large flat piece of cardboard
from dryer carton; place under entire back edge of dryer.
Firmly grasp dryer body (not console panel) and gently lay
dryer down on cardboard.
2, Screw in leveling legs
Using a wrench and tape measure, screw legs into leg holes
until bottom of foot is approximately 1/2" (13 mm) (to match
height of 3.6 cu. ft. capacity washer) or 11/2'` (38 mm) (to
match height of 3.8 cu. ft. capacity washer) from bottom of
dryer.
Now stand the dryer on its legs. Slide the dryer until it is
close to its final location. Leave enough room for electrical
connection and to connect the exhaust vent.
For mobile home use
Gas dryers must be securely fastened to the floor.
Mobile home installations require a Mobile Home installation
Hold-down Kit. For ordering information, please reference the
"Use and Care Guide."
GAS DRYER POWER HOOKUP
Gas Supply Requirements
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut=off valve.
Securely tighten all gas connections.
if connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas type
Natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate conversion.
[]
Your dryer must have the correct burner for the type of gas
in your home. Burner information is located on the rating
plate in the door well of your dryer. If this information does
not agree with the type of gas available, please reference the
"Assistance or Service" section of the "Use and Care Guide."
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier.
iMPORTANT: The gas installation must conform with local codes,
or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and
Propane Installation Code, CSA B149.1.
Gassupply line []
[] 1/2" NPT pipe is recommended.
[] 3/8" approved tubing is acceptable for lengths under
20 ft. (6.1 m) if local codes and gas supplier permit.
[] Must include 1/8" NPT minimum plugged tapping accessible
for test gauge connection, immediately upstream of the gas
connection to the dryer (see illustration).
[] Must include a shut-off valve:
in the U.S.A.:
An individual manual shut-off valve must be installed within
six (6)feet (1.8 m) of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1.
In Canada:
An individual manual shut-off valve must be installed in
accordance with the B149.1, Natural Gas and Propane
Installation Code. It is recommended that an individual
manual shut-off valve be installed within six (6) feet (1.8 m)
of the dryer.
The shut-off valve location should be easy to reach for opening
and closing.
E
B
A. 3/8" flexible gas connector
B.3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged tapping
D. 1/2" NPT gas supply line
E. Gas shut-off valve
Gas supply connection requirements
There are many methods by which your gas dryer can be
connected to the gas supply. Listed here are some guidelines
for two different methods of connection.
This dryer must be connected to the gas supply line with
a listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24 or CSA 6.10.
Option 1 (Recommended Method}
Flexible stainless steel gas connector:
[] If local codes permit, use a new flexible stainless steel gas
connector (Design Certified by the American Gas Association
or CSA International) to connect your dryer to the rigid gas
supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter
fitting between the stainless steel gas connector and the
dryer gas pipe, as needed to prevent kinking.
Option 2 (Alternate Method}
Approved aluminum or copper tubing:
[] Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing
(if codes and gas supplier permit).
[] If you are using Natural Gas, do not use copper tubing.
[] 3/8" flare x 3/8" NPT adapter fitting between dryer pipe
and 3/8" approved tubing.
[] Lengths over 20 ft. (6.1 m) should use larger tubing and
a different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP
gas must be used. Do not use TEFLON _>ttape.
Dryer gas pipe
[] The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
29" Wide Model
A 91/4"''_
(235 ram)
11/4"
(32 rnm}
A. 3/8" NPTdryer pipe
27" Wide Model
*5 3/4"
(146 mm)
A
11/2"
(38 rnm)
A. 3/8" NPTdryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m}:
[] The design of this dryer is certified by CSA International for
use at altitudes up to 10,000 ft. (3,048 m) above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
Elevations above 10,000 ft. (3,048 m}:
[] When installed above 10,000 ft. (3,048 m), a 4% reduction
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. (305 m)
increase in elevation.
Gas supply pressure testing
[] The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
1-®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
8
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to fo(Iow these instructions can result in death,
fire, or electrical shock.
[]
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. It is also recommended that a separate
circuit serving only this dryer be provided.
GROUNDING iNSTRUCTiONS
[] For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or
breakdown, grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must
be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
VENTING
Venting Requirements
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING: To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
iMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
( O'
(102 ram)
+
4" (102 mm) heavy metal exhaust vent
[] Only a 4" (102 mm) heavy metal exhaust vent and clamps
may be used.
[] Do not use plastic or metal foil vent.
Rigid metal vent:
[] Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
[] Must be fully extended and supported in final dryer location.
[] Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance.
[] Do not install in enclosed walls, ceilings, or floors.
[] The total length should not exceed 73/4ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or flexible metal vents. Review "Vent System Chart" and,
if necessary, modify existing vent system to achieve best drying
performance.
Exhausthoods:
[] Must be at least 12" (305 mm) from ground or any object
that may obstruct exhaust (such as flowers, rocks, bushes,
or snow).
Recommended St__les:
Louveredhood
Acceptable Style:
Box hood
Angled hood
Elbows:
[] 45° elbows provide better airflow than 90° elbows.
Bet
Clamps:
[] Use clamps to seal all joints.
[] Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
improper venting can cause moisture and tint to collect
indoors, which may result in:
[] Moisture damage to woodwork, furniture, paint, wallpaper,
carpets, etc.
[] Housecleaning problems and health problems.
See "Venting Kits" for more information.
Plan Vent System
Recommended exhaust installations
Typical installations vent the dryer from the rear of the dryer.
Other installations are possible.
B
-'11
B
_H
A. Dryer
B. Elbow
C, Wall
D. Exhaust hood
E. Clamps
E Rigid metal or flexible metal vent
G. Vent length necessary to connect elbows
H. Exhaust outlet
I. Optional side exhaust outlet
Optional exhaust installations:
27" Wide Models can be converted to exhaust out the right side,
left side, or through the bottom (4-way vent kit). Each kit includes
step-by-step instructions. For ordering information, see "Venting
Kits."
!
Fire Hazard
Cover unused exhaust holes with a manufacturer's
exhaust cover kit,
Contact your local dealer,
Failure to follow these instructions can result in death,
fire, electrical shock, or serious injury,
A B c
A, Standard rear offset exhaust installation
B. Left- or right-side exhaust installation
(27" wide models only)
C. Bottom exhaust installation (27" wide models only)
10
Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
Over-The-Top installation (also available with one offset elbow)
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1=800=901=2042, or visit us
at www.applianceaccessories.com, in Canada, call
1=800=807=6777 or visit us at www.whirlpooiparts.ca.
Part Number Descriptions
8171587RP 0-5" Metal vent periscope
4396037RP 0"-18" Metal vent periscope
4396011RP 18"-29" Metal vent periscope
4396014 29"-50" Metal vent periscope
4392892 In-Wall metal DuraVent TM Periscope
W10186596 4-way vent kit - universal grey (27" Dryers Only)
4396028 Sure Connect TM venting kit
(over-the-top installation)
4396009RP 5' Universal connect vent, flexible dryer venting
4396010RP 6' SecureConnect TM vent, flexible dryer venting
4396013RB Dryer vent installer's kit
4396033RP 5' flexible dryer venting with clamps
4396727RP 8' flexible dryer venting with clamps
4396004 Dryer offset elbow
4396005 Wall offset elbow
4396006RW DuraSafe TM close elbow
4396007RW Through-the-wall vent cap
4396008RP 4" steel dryer venting clamps - 2 pack
8212662 Flush mounting Iouvered vent hood 4"
Determine vent path:
[] Select route that will provide straightest and most direct path
outdoors.
[] Plan installation to use fewest number of elbows and turns.
[] When using elbows or making turns, allow as much room
as possible.
[] Bend vent gradually to avoid kinking.
[] Use as few 90° turns as possible.
Determine vent length and elbows needed for best
drying performance:
[] Use following "Vent System Chart" to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in "Vent System Chart." Exhaust systems longer than those
specified will:
[] Shorten life of dryer.
[] Reduce performance, resulting in longer drying times and
increased energy usage.
The "Vent System Chart" provides venting requirements that
will help achieve best drying performance.
Vent System Chart
Number of
90 °turns or
elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered Angled
hoods hoods
64 ft. (20 m) 58 ft. (17.7 m)
54 ft. (16.5 m) 48 ft. (14.6 m)
44 ft. (13.4m) 38 ft. (11.6m)
35 ft. (10.7 m) 29 ft. (8.8 m)
27 ft. (8.2 m) 21 ft. (6.4 m)
NOTE: Side and bottom exhaust installations for 27" wide
models have a 90° turn inside the dryer. To determine
maximum exhaust length, add one 90° turn to the chart.
11
Vent System Chart
(29" Wide Long Vent Models Only)
Number of Type Box/Iouvered, or
90 ° turns of vent Angled hoods
or elbows
0 Rigid metal 120 ft. (36.6 m)
1 Rigid metal 110 ft. (33.5 m)
2 Rigid metal 100 ft. (30.5 m)
3 Rigid metal 90 ft. (27.4 m)
4 Rigid metal 80 ft. (24.4 m)
5 Rigid metal 70 ft. (21.3 m)
Install Vent System
1. install exhaust hood
.==_---12" rnin.
(305 ram)
install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
_2. Connect vent to exhaust hood
Vent must fit over the exhaust hood. Secure vent to exhaust
hood with 4" (102 mm) clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
Make Gas Connection
1. Connect gas supply to dryer
Flared
male fitting
Remove red cap from gas pipe. Using a wrench to tighten,
connect gas supply to dryer. Use pipe-joint compound
on threads of all non-flared male fittings, if flexible metal
tubing is used, be sure there are no kinks.
NOTE: For LP gas connections, you must use pipe-joint
compound resistant to action of LP gas. Do not use
TEFLON ®ttape.
2, Plan pipe fitting connection
B
A. 3/8" flexible gas connector
B. 3/8" dryer pipe
C
C. 3/8" to 3/8" pipe elbow
D.3/8" pipe-to-flare adapter fitting
A combination of pipe fittings must be used to connect dryer
to existing gas line. A recommended connection is shown.
Your connection may be different, according to supply line
type, size, and location.
3. Open shut-off valve
Open shut-off valve in supply line; valve is open when handle
is parallel to gas pipe. Then, test all connections by brushing
on an approved noncorrosive leak-detection solution.
Bubbles will show a leak. Correct any leaks found.
12 1®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.
Connect Vent
Tighten and adjust leveling legs
Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must fit over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 4" (102 mm) clamp.
2, Move dryer to final location
Move dryer to final location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.
Level Dryer
Check levelness of dryer from side to side. Repeat from
front to back.
NOTE: The dryer must be level for the moisture sensing system
to operate correctly.
If dryer is not level or the same height as the washer, prop up
using a wood block. Use wrench to adjust legs up or down,
and check again for levelness. Once legs are level, make sure
all four legs are snug against the floor before tightening them.
Complete Installation Checklist
[_ Check that all parts are now installed. Ifthere is an extra
part, go back through steps to see what was skipped.
[_ Check that you have all of your tools.
[_ Dispose of/recycle all packaging materials.
[_ Check dryer's final location. Be sure vent is not crushed
or kinked.
[_ Check that dryer is level. See "Level Dryer."
[_ Remove film on console and any tape remaining on dryer.
[_ Wipe dryer drum interior thoroughly with a damp cloth to
remove any dust.
[_ Read "Dryer Use" in your "Use and Care Guide."
[_ Set the dryer on a full heat cycle (not an air cycle) for
20 minutes and start the dryer.
if the dryer will not start, check the following:
[] Dryer is plugged into a grounded 3-prong outlet.
[] Electrical supply is connected.
[] Household fuse is intact and tight, or circuit breaker
has not tripped.
[] Dryer door is closed.
[_ When the dryer has been running for 5 minutes, open the
dryer door and feel for heat. If you feel heat, cancel cycle
and close the door.
If you do not feel heat, turn the dryer off and check to see
whether gas supply line shut-off valve is open.
[] If the gas supply line shut-off valve is closed, open it,
then repeat the 5-minute test as outlined above.
[] If the gas supply line shut-off valve is open, contact a
qualified technician.
NOTE: You may notice an odor when the dryer is first heated.
This odor is common when the heating element is first used.
The odor will go away.
Not Level LEVEL Not Level 13
Reverse Door Swing (Optional}
If your door is the 29" Super Wide Side-Swing Door,
go to steps 1-13 beginning on this page.
If your door is the 27" Wide Side-Swing Door, go to steps 1-11
beginning on page 16.
If your door is the 27" Wide Side-Swing Door with Glass, go to
steps 1-13 beginning on page 19.
NOTE: Magnetized screwdriver is helpful.
29" Super Wide Side=Swing Door
1, Place towel on dryer
Place towel on top of dryer to avoid damaging the surface.
Remove bottom screws
open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
,,,Lift door off top screws
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
Remove screws attaching hinges to door.
14
5, Remove screws from door
Remove screws at top, bottom, and side of door (4 screws)
that hold the inner and outer door together. Holding door over
towel on dryer, grasp sides of outer door and lift to separate it
from inner door. Set outer door aside.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.
6, Switch door catch, bezel, & plug
Catch and bezel Plug
8, Flip door over
\
Flip door over so handle side is down.
Remove the door catch, bezel, and plug from the inside of
the inner door by squeezing and pulling/pushing them. Place
the door catch, bezel, and plug on the sides opposite from
where they were.
7= Rotate outer door
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
Rotate outer door 180° and set it back down on inner door.
Reattach outer door panel to inner door panel so handle is
on the side where hinges were just removed. Insert 4 door
screws.
15
O, Remove door strike and
door strike plug
dryer cabinet
Remove door strike and door strike plug from dryer cabinet.
Insert the door strike into door strike plug hole and secure
with screw. Insert door strike plug into original door strike
hole and secure with screw.
1"1, emove and transfer
hinge hole plugs
Use a small, flat-blade screwdriver to gently remove 4 hinge
hole plugs on left side of dryer cabinet. Transfer plugs into
hinge holes on opposite side of dryer cabinet.
NOTE: Two people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer
cabinet. Tighten screws halfway. Position door so large
end of door hinge slot is over screws. Slide door up so
screws are in bottom of slots. Tighten screws. Insert and
tighten top screws in hinges.
13. Check door strike alignment
V--
Close door and check that door strike aligns with door
catch. If it is needed, slide door catch left or right within slot
to adjust alignment.
27" Wide Model Side-Swing Door
1, Place towel on dryer
Place towel on top of dryer to avoid damaging the surface.
16
Remove bottom screws
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
Lift door off top screws
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
Remove screws from hinges
Remove screws from door
\
Remove screws at top, bottom, and side of door (6 screws).
Keep door screws separate from hinge screws as they are
different sizes. Holding door over towel on dryer, grasp sides
of outer door and lift to separate it from inner door.
NOTE: Do not pry apart with putty knife or screwdriver.
Do not pull on door seal or plastic door catches.
6. Rotate outer door
Rotate outer door 180 ° and set it back down on inner door.
Be certain to keep cardboard spacer centered between doors.
Reattach outer door panel to inner door panel so handle is on
the side where hinges were just removed. Insert 6 door screws.
Flip door over
Flip door over so handle side is down.
Remove screws attaching hinges to door.
17
8, Attach door hinges
............... i-
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
dryer cabinet
NOTE: 2 people may be needed to reinstall door.
Insert screws into the bottom holes on left side of dryer cabinet.
Tighten screws halfway. Position door so large end of door hinge
slot is over screws. Slide door up so screws are in bottom of
slots. Tighten screws. Insert and tighten top screws in hinges.
1
Close door and check that door strike aligns with door catch.
If it is needed, slide door catch left or right within slot to
adjust alignment.
Remove the 4 screws that attach 2 plugs on the left side.
Transfer plugs to opposite side using the same 4 screws.
18
27" Wide Model Side-Swing Door with Glass
1, Place towel on dryer
©
Place towel on top of dryer to avoid damaging the surface.
_==_._Remove bottom screws
Remove screws attaching hinges to door.
Open dryer door. Remove bottom screws from dryer cabinet
side of hinges. Loosen (do not remove) top screws from dryer
cabinet side of hinges.
Flip door over so handle side is down.
Lift door off top screws
Lift door until top screws in dryer cabinet are in large part of
hinge slot. Pull door forward off screws. Set door (handle side
up) on top of dryer. Remove top screws from dryer cabinet.
19
6, Remove screws from door
\
Remove screws at top, bottom, and side of door (4 screws).
Keep door screws separate from hinge screws as they are
different sizes.
7, Separate inner from outer door
9, Attach door hinges
Holding door over towel on dryer, pry inner door and lift to
separate it from outer door.
NOTE: Do not pull on door seal or plastic door catches.
8, Rotate outer door
Rotate outer door 180 ° and set it back down on inner door.
Be certain to keep cardboard spacer centered between
doors. Reattach outer door panel to inner door panel so
handle is on the side where hinges were just removed. Insert
4 door screws.
Reattach door hinges to dryer door so that the larger hole is
at the bottom of the hinge.
strike label
Remove door strike and door strike label from dryer cabinet.
Insert the door strike into hole where door strike label was
removed and secure with screw. Cover original door strike
hole with door strike label and press firmly into place.
2O
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Whirlpool WGD5000DW1 Guide d'installation

Catégorie
Sèche-linge
Taper
Guide d'installation

dans d''autres langues