Preparing the Table
WARNING: Wear safety glasses when cutting the hole in the table. Failure to comply may result in eye injury.
AVERTISSEMENT : Veillez à toujours porter des lunettes de protection lorsque vous percez la table. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
ATTENTION: The opening in the table for the HSA should be cut only by licensed and bonded craftspeople.
• Exercise care to prevent scarring or damaging the furniture.
• Ensure that the table surface is:
• At least 3/8 inch (0.325") (9.5 mm) thick.
• No more than 1-3/4 inch (1.75") (44.5 mm) thick.
Cut a hole in the surface where the enclosure will be installed. There are three methods for cutting the hole in the table:
• A hand router and the appropriate Extron HSA routing template. See the table for par numbers.
HSA 200
USER ACCESS
HSA 200
CABLE CUBBY 300
CABLE CUBBY 300
USER ACCESS
Router
See the HSA Series and HSA Routing Template User Guide, available on the Extron website,
www.extron.com, to prepare the template and use the template to cut the hole.
NOTE: The metal routing template is reusable. Do not discard this routing template
when the installation is complete.
• A CNC wood router and the exact cut-out dimensions for your model. See the table below for
cut-out dimensions:
• A jigsaw and a paper cut-out template (available on the Extron website,
www.extron.com).
NOTE: The underlined dimension in the table below is the AAP and connector
access side.
Template
Part
Number
Surface Cut-out Dimensions
Product
Width Depth
HSA 400 (USA) 70-189-01
8.14 inches (20.68 cm) 5.95 inches (15.11 cm)
HSA 400 (Int’l) 70-189-02
9.64 inches (24.49 cm) 5.95 inches (15.11 cm)
HSA 402 (USA) 70-190-01
10.37 inches (26.34 cm) 5.95 inches (15.11 cm)
HSA 402 (Int’l) 70-190-02
13.37 inches (33.96 cm) 5.95 inches (15.11 cm)
HSA 822 (all regions) 70-191-01
8.03 inches (20.40 cm) 8.33 inches (21.16 cm)
Mounting the HSA in the Table and Connecting Cables
ATTENTION: Be careful when handling and mounting the enclosure. Mishandling can
damage the appearance of the enclosure.
1. Unbolt the clamshell from the enclosure (the shipped position).
2. Remove the plastic strips that protect the corners of the enclosure and the plastic lm on
the nished surfaces.
3. Carefully lower the HSA into the hole to test the t (see the image on the right,
3
). If
necessary, carefully enlarge the opening.
4. Under the table, bolt the clamshell to the enclosure with two bolts of optimum length
(
4
).
5. Under the table, connect the RJ-45 connectors (
5
).
•
The network cables are terminated in accordance with the TIA/EIA T568B standard
inside the HSA.
• See the drawings on the next page to understand the relationship between the RJ-45
connectors on the bottom of the unit to the connectors on the faces of the unit.
User Access
Cut-Out Template for Extron's
Cable Cubby 200
.350" (0.90 cm)
Print this
template
at 100%
Trim Ring
Lip
Trim Ring’s Outer Edge
0.00” (0.00 cm)
0.02 (0.05 cm)
+
1. Confirm Product to be installed
2. Measure cutout and template
3. After checking, cut opening
HSA 400
COMPUTER
125 - 50/60 Hz 5A
HSA 400
33
5
4
HSA 400 / 402 / 822 • Installation Guide