Extron Hideaway HSA 822 Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

HSA 402
AUDIO
PHONE
DATA
125 - 50/60 Hz 5A
PHONE
125 - 50/60 Hz 5A
HSA 402
DATA
IMPORTANT:
Go to www.extron.com for the complete
user guide,
installation instructions,
and
specifications bef
ore connecting the
pr
oduct to the po
wer source.
1
Hideaway
®
Surface Access Products • Installation Guide
This guide provides instructions for an experienced installer to install and connect the
Extron HSA 400, HSA 402, and HSA 822.
The HSA units are lift-up architectural solutions for inconspicuous A/V connectivity access, control,
and AC power.
Planning
Determine the best location for the enclosure. Before making any cuts:
c Ensure that the location where the HSA is to be installed is convenient for
as many users as possible.
c Ensure that the edge on which the HSA opens is oriented correctly.
c Ensure that there is ample space under the table for cables.
c Ensure that the correct template or dimensions are used.
Decide on the method for cutting the hole in the table.
c Hand router and template
c CNC wood router
c Jigsaw and paper template
Before starting the installation, check with local and state regulations:
c Ensure that the planned installation complies with building and
electrical codes.
c Ensure that the planned installation complies with the Americans with Disabilities Act or other accessibility requirements.
Tools and Equipment Required for Installation
Safety Glasses
Screw Driver
Tape Measure
Vacuum Cleaner
7/16" Hex Nut Driver or Wrench (US)
10 mm Hex Nut Driver or Wrench (Int’l)
1/4" Hex Nut Driver (for AAPs)
Marking Pen
Square
Included Parts
HSA 400
HSA 402
Clamshell Bolts
(4) sets of (2)
(various lengths)
HSA 822
COMPUTER
AUDIO
125 - 50/60 Hz 5A
HSA 400
125 - 50/60 Hz 5A
125 - 50/60 Hz 5A
HSA 402
Allen Wrench
(included with HSA 400
and HSA 402 only)
Zip Ties
Icon Kit
Bezel Kit
Tweeker (1)
C
AT 6
C
AT 6
C
AT 6
C
AT 6
2
Preparing the Table
WARNING: Wear safety glasses when cutting the hole in the table. Failure to comply may result in eye injury.
AVERTISSEMENT : Veillez à toujours porter des lunettes de protection lorsque vous percez la table. Ne pas respecter cela peut
conduire à une blessure à l’oeil.
ATTENTION: The opening in the table for the HSA should be cut only by licensed and bonded craftspeople.
Exercise care to prevent scarring or damaging the furniture.
Ensure that the table surface is:
At least 3/8 inch (0.325") (9.5 mm) thick.
No more than 1-3/4 inch (1.75") (44.5 mm) thick.
Cut a hole in the surface where the enclosure will be installed. There are three methods for cutting the hole in the table:
A hand router and the appropriate Extron HSA routing template. See the table for par numbers.
HSA 200
USER ACCESS
HSA 200
CABLE CUBBY 300
CABLE CUBBY 300
USER ACCESS
Router
Wear Safety Glasses
See the HSA Series and HSA Routing Template User Guide, available on the Extron website,
www.extron.com, to prepare the template and use the template to cut the hole.
NOTE: The metal routing template is reusable. Do not discard this routing template
when the installation is complete.
A CNC wood router and the exact cut-out dimensions for your model. See the table below for
cut-out dimensions:
A jigsaw and a paper cut-out template (available on the Extron website,
www.extron.com).
NOTE: The underlined dimension in the table below is the AAP and connector
access side.
Template
Part
Number
Surface Cut-out Dimensions
Product
Width Depth
HSA 400 (USA) 70-189-01
8.14 inches (20.68 cm) 5.95 inches (15.11 cm)
HSA 400 (Int’l) 70-189-02
9.64 inches (24.49 cm) 5.95 inches (15.11 cm)
HSA 402 (USA) 70-190-01
10.37 inches (26.34 cm) 5.95 inches (15.11 cm)
HSA 402 (Int’l) 70-190-02
13.37 inches (33.96 cm) 5.95 inches (15.11 cm)
HSA 822 (all regions) 70-191-01
8.03 inches (20.40 cm) 8.33 inches (21.16 cm)
Mounting the HSA in the Table and Connecting Cables
ATTENTION: Be careful when handling and mounting the enclosure. Mishandling can
damage the appearance of the enclosure.
1. Unbolt the clamshell from the enclosure (the shipped position).
2. Remove the plastic strips that protect the corners of the enclosure and the plastic lm on
the nished surfaces.
3. Carefully lower the HSA into the hole to test the t (see the image on the right,
3
). If
necessary, carefully enlarge the opening.
4. Under the table, bolt the clamshell to the enclosure with two bolts of optimum length
(
4
).
5. Under the table, connect the RJ-45 connectors (
5
).
The network cables are terminated in accordance with the TIA/EIA T568B standard
inside the HSA.
See the drawings on the next page to understand the relationship between the RJ-45
connectors on the bottom of the unit to the connectors on the faces of the unit.
User Access
Cut-Out Template for Extron's
Cable Cubby 200
.350" (0.90 cm)
Print this
template
at 100%
Trim Ring
Lip
Trim Ring’s Outer Edge
0.00” (0.00 cm)
0.02 (0.05 cm)
+
1. Confirm Product to be installed
2. Measure cutout and template
3. After checking, cut opening
e
g
HSA 400
COMPUTER
125 - 50/60 Hz 5A
HSA 400
33
5
4
HSA 400 / 402 / 822 • Installation Guide
3
Internal RJ-45 Cable
Routing
Cabling and Installing the AAPs
ATTENTION: Ensure that AC power is disconnected before removing the front panel.
1. Remove and retain the four screws on the right and left sides of the front panel.
Lift the panel away from the enclosure.
ATTENTION: On the HSA 822, do NOT remove the center screws. They do not
fasten the AAP panel in place. They secure the AC power outlet.
2. Secure each AAP to the panel with the provided #4-40 nuts.
3. Route the AAP cables through the hole in the underside of the HSA and connect them
to the rear of the AAPs.
4. Reinstall the front panel in the enclosure and secure it in place with the screws removed
in step 1.
Dressing the Cables
1. Lift the HSA to extend the AAP cables to their maximum pull.
2. Experiment with AAP cable positioning to ensure that the cables do not rub
against any edges and that the cable pull does not restrict the HSA lifting movement.
The gures below show the recommended cable routing.
3. Route the cables as recommended in the photos below. Secure the cables in the
circled locations with the provided zip ties.
HSA 400
(shown w/ cables)
HSA 400
125 - 50/60 Hz 5A
Do not
Remove
Center
Screw
HSA 822
HSA 822
HSA 402 Rear View
HSA 822
Vie
w from
one side
Shown with clamshell removed
for clarity.
View from the opposite side
HSA 402
120-240 50/60 Hz 5A 120-240 50/60 Hz 5A
A1
A2
B1
B2
A1
A2
B1
B2
A B
A B C D
C D
HSA 822
HSA 400 / HSA 40
2
Present on
HSA 402 Only
Present on
HSA 402 Only
Extron Headquarters
+800.633.9876 Inside USA/Canada Only
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
EExtron Australia
+61.8.8351.2188
+61.8.8351.2511 FAX
Extron India
1800.3070.3777
(Inside India Only)
+91.80.3055.3777
+91.80.3055.3737 FAX
© 2017 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com
68-2107-50
Rev B 0
1 17
Installation Checklist
Planning (page 1)
Choose a location. Consider the following:
Ensure that the edge on which the lid opens faces the table position of the most likely user.
Ensure that there is ample space under the table for cable routing.
Ensure that there is a nearby electrical outlet.
Preparing the Table (page 2)
Ensure that you are using the correct template or dimensions.
Cut the hole.
Mounting the HSA (page 2)
Install the HSA and secure the clamshell.
Connect the RJ-45 cables.
Installing the AAPs (page 3)
Install the AAPs.
Route and connect the AAP cables.
Dressing the Cables (page 3)
Dress the cables out of the way to prevent lifting restrictions.
Connect the HSA AC Power
4
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Extron Hideaway HSA 822 Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à

dans d''autres langues