INSTALLATION
INSTRUCTIONS
- The installation must be executed by a qualifi ed technician.
- Must be installed solidly. This heater could weight
up to 35 lb (16 kg).
- The motor is thermally protected.
- All wiring must be in accordance with National and local
Electrical Codes.
- Heater must be grounded as a precaution against possible shock.
- To avoid possible electrical shock, disconnect all power at the
main panel prior to wiring.
- Verify the power supply voltage coming to the heater matches
the heater nameplate rating before energizing heater.
- When installed, heater must be electrically grounded in
accordance with the National Electrical Code.
CAUTION
- High temperature, risk of fi re, keep electrical cords, drapery,
furnishings, and other combustibles at least 36 in. (915 mm) from
the front of the heater. To reduce the risk of fi re, do not store or
use gasoline or other fl ammable vapors and liquids in the vicinity
of the heater.
- Ceiling installation only.
- Use copper wire only.
STANDARD CEILING MOUNTING
1. Never install the air-forced diffuser at less than 8 ft. (250 cm)
from the fl oor and 12 in. (30 cm) from adjacent walls.
2. Provide an exit for the power supply wires in the ceiling,
under the heater.
3. Mount the ceiling support using provided screws.
For drop ceiling mounting, the necessary kit is not provided.
4. Suspend the heater at the hangers of the ceiling support.
5. Convey the wires of power supply to the junction box of
the heater and connect the heater leads to the supply leads
according to the local and national codes.
See wiring diagram.
6. Fold back the heater toward the ceiling and fi x it using
the screw provided..
7. Install the front cover using provided screws (4).
DROP CEILING MOUNTING with T-BAR option
1. Install the T-BAR on the ceiling using chains, steel
wires or bar.
2. Mount the ceiling support on the T-BAR option.
3. Follow instructions 4 to 7 as above for STANDARD CEILING
MOUNTING.
OPTIONS
See installation pamphlet provided with the various options
for the installation of those options.
Read carefully these instructions before installation, operation of
the heater. Failure to adhere to the instructions could result in fi re,
electric shock, serious personal injury, and death or property damage.
Review frequently for continuing safe operation and instruction of
future users, if necessary.
IMPORTANT
INSTRUCTIONS
1- Read all instructions before installing or using this heater.
2- This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
like furniture, pillows, bedding, papers, clothes, and
curtains at least 36 in. (915 mm) from the front of the heater.
3- Extreme caution is necessary when any heater is used by
or near children or invalids and whenever the heater is left
operating and unattended.
4- Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a
reputable electrician before reusing.
5- Do not use outdoors.
6- Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause an electric
shock or fi re, or damage the heater.
7- Do not block air intakes or exhaust in any way whatsoever.
8- This heater has hot and arcing or sparking parts inside.
Do not use it in areas where gasoline, paint, or fl ammable
liquids are used or stored.
9- Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fi re,
electric shock, or injury.
10-
SAVE THESE
INSTRUCTIONS
OPERATING
INSTRUCTIONS
The heater must be properly installed before it is used.
START UP
- Turn the power on at the circuit breaker panel.
- Electronic thermostat: be sure to set it on the fan mode.
- Built-in tamperproof thermostat: the setting can be done with
a small slotted screwdriver.
- On a call for heat from either remote thermostat or unit mounted
thermostat, the elements and fan will be energized.
- When the thermostat is satisfi ed, elements will be deenergized.
- The fan will continue to run until the residual heat is removed
from the heater. Then the fan will stop.
Automatic Reset Thermal High Limit
The heater has an automatic reset thermal high limit that will
deenergize the heating elements if the interior temperatures of
heater exceed its setting. The limit will automatically reset when
the heater interior temperatures fall below its setting.
MAINTENANCE
INSTRUCTIONS
- The heater motor is permanently lubricated.
- Wait until the housing and heating elements cool before
performing maintenance.
- Once a year, remove the front cover and use a vacuum cleaner or
compressed air to remove the dust accumulation inside the heater.
- Cleaning should be done while the heater is disconnected from
the power supply circuit.
- A qualifi ed technician should perform any other servicing.
WARRANTY
The manufacturer warrants the electric heating element for a
ten (10) year period; and its component parts against defects in
material and workmanship for a one (1) year period following the
date of purchase, under normal use and service, when proof of
purchase of such is provided to the manufacturer. The obligation of
the manufacturer, under the terms of this warranty, will be to supply
a new unit and this omits the manufacturer to bear the installation
costs or other secondary charges linked to replacing the unit or the
component part(s).
KEEP THIS INSTRUCTION PAMPHLET
FOR THE USER
WARNING
When using electrical appliances, basic precautions should always
be taken to reduce the risk of fi re, electrical shock and injury,
including the following:
IMPORTANT
Connect the control (thermostat or relay)
to the T1-T2 position on the terminal block.
Do not interrupt power supply to control this heater.
INS482-200404-04
Model (7.5 kW to 10 kW)
2
1
T-BAR Option
Reznor LLC
O’Fallon, MO USA 63368 - Tel.: 1 800 695-1901
www.ReznorHVAC.com
©2014 Reznor, LLC. All rights reserved. All other trademarks are
the property of their respective organizations.
INSTRUCTIONS
ECS Model (7.5 kW to 10 kW)