Date Issued: 09/12/17 IS-49964-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
1) Thread small threaded pipe[1] into end of second loop[2]. Pass
threaded pipe on loop up through hole in canopy[3].
2) Thread lockwasher[4] onto end of threaded pipe protruding
from inside canopy.
3) Thread hexnut[5] onto threaded pipe protruding from inside
canopy.
4) Attach one end of chain[6] to loop[7] on top of roof. Attach
other end of chain to small loop on canopy.
5) Weave electrical wire and ground wire through chain links no
more than 3 inches apart.
6) Find the appropriate threaded holes on mounting strap[8] that
align with hole distance in canopy. Thread mounting screws[9]
into threaded holes starting from outlet box[10] side.
7) Attach mounting strap to outlet box with strap mounting
screws[11]. Mounting strap can be adjusted to suit position of
xture.
8) Grounding instructions: (See Illus. A or B).
A) Onxtureswheremountingstrapisprovidedwithahole
and two raised dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) Onxtureswhereacuppedwasherisprovided.Attach
ground wire from outlet box under cupped washer and
green ground screw, and thread into mounting strap.
Ifxtureisprovidedwithgroundwire.Connectxtureground
wire to outlet box ground wire with wire connector. After follow-
ing the above steps. Never con¬nect ground wire to black or
white power supply wires.
9) Make wire connections. Reference chart below for correct con-
nections and wire accordingly.
10) Pushxturetoceiling,carefullypassingmountingscrews
through holes in canopy.
11) Thread lock-up knobs[12] onto mounting screws. Tighten
knobstosecurexturetoceiling.
12) Raise glass[13]upintoxture,passthesmalleropeningofthe
glass over socket[14]. Rest the top of the glass against the
padsinthextureroof.
13) Thread the socket ring[15] onto the socket. Tighten to secure
the glass in place. (Do not over-tighten).
14 ) Insert recommended bulb (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
14
13
15
9
10
11
8
3
12
6
2
5
4
1
7