NanoBeam 5AC Gen 2 Ball Joint Mount Lock Ring
Metal Strap Gigabit PoE (24V, 0.5A) with
Mounting Bracket
Power Cord
Package Contents
Installation Requirements
Pole-mounting: 7 mm socket wrench or screwdriver
Wall-mounting: wall fastener (not included)
Shielded Category 5 (or above) cabling with drain wire should be used for all wired
Ethernet connections and should be grounded through the AC ground of the PoE.
We recommend that you protect your networks from harmful outdoor environments
and destructive ESD events with industrial-grade, shielded Ethernet cable from
Ubiquiti. For more details, visit ui.com/toughcable
Surge protection should be used for all outdoor installations. We recommend that
you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoBeam and
the other at the entry point to the building. The ETH-SP will absorb power surges and
safely discharge them into the ground.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 2/18
Hardware Overview
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 3/18
Main Ethernet Port
Reset Button
Secondary Ethernet Port
Power LED
Main LED
LAN2 LED
Signal LEDs
This Gigabit Ethernet port is used to connect the power and should be connected to
the LAN and DHCP server.
To reset to factory defaults, press and hold the Reset button for more than 10
seconds while the device is powered on. Alternatively, the device may be reset
remotely via a Reset button located on the bottom of the Gigabit PoE Adapter.
This Gigabit Ethernet port provides passthrough PoE to power and connect a 24V
passive PoE device to the network.
Note: In order to use PoE Passthrough on the Secondary port, a 24V, 1A
PoE adapter is required.
The Power LED will light blue when the device is connected to a power source.
The LED will light steady blue when an active Ethernet connection is made to the
Main port and flash when there is activity.
The LED will light steady blue when an active Ethernet connection is made to the
LAN2 port and flash when there is activity.
In airOS®, you can modify the threshold value for the wireless signal strength LEDs
on the Wireless tab under Signal LED Thresholds. Each LED will light when the
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 4/18
wireless signal strength is equal to or greater than the LED’s threshold value. The
default threshold values for these LEDs are shown below:
Hardware Installation
Go to the appropriate mounting instructions: Pole Mounting or “Wall Mounting”.
Pole Mounting
1.
2.
3.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 5/18
4.
Wall Mounting
The NanoBeam must be mounted directly to a wood stud or other structurally stable
surface to avoid damage to the mounting hole when you adjust the aim.
Optional Accessory
To enhance stability, you can use the NanoBeam Wall Mount Kit, model NBE-WMK
(sold separately).
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 6/18
Note: Center screw included. Two optional screws (not included) provide
additional stability.
Installation Instructions
1.
2.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 7/18
3.
4.
Fastener (not included)
OR
NanoBeam Wall Mount Kit
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 8/18
Aiming
1.
2.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 9/18
Connecting Power
1.
2.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 10/18
3.
4.
WARNING: The switch port must comply with the power specifications
listed in this Quick Start Guide.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 11/18
OR
Optional
Accessing airOS via Wi-Fi
Verify connectivity in the airOS® Configuration Interface using the UNMS™ app or Web
Portal. Both are available for 15 minutes immediately after you power on the device. If
necessary, you can power cycle the device to re-enable its Wi-Fi.
UNMS App
1. Download the UNMS app.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 12/18
2. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
3. Launch the app and follow the on-screen instructions.
Web Portal
1. Connect your device’s Wi-Fi to the SSID named: <model>:<MAC Address>
2. Launch your web browser and go to: http://setup.ui.com
3. Select your Country and Language. You must agree to the Terms of Use to use the
product. Click Continue.
4. Create a username and password. Confirm your new password and then click Save.
Note: Ensure that DHCP is enabled on your Wi-Fi adapter.
Note: Ensure that your Wi-Fi connection has DHCP enabled.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 13/18
The airOS Configuration Interface will appear, allowing you to customize your settings as
needed. For additional details, refer to the User Guide available at
ui.com/download/airmax-ac
Installer Compliance Responsibility
Devices must be professionally installed and it is the professional installers responsibility
to make sure the device is operated within local country regulatory requirements.
The Output Power field is provided to the professional installer to assist in meeting
regulatory requirements.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 14/18
Specifications
NBE-5AC-Gen2
Dimensions 189 x 189 x 125 mm
(7.44 x 7.44 x 4.92")
Weight 530 g
(1.17 lb)
Gain 17 dBi
Networking Interface (2) 10/100/1000 Ethernet Ports
Wi-Fi for Management
Enclosure Outdoor UV Stabilized Plastic
Max. Power Consumption 8.5W
Power Supply 24V, 0.5A Gigabit PoE Adapter (Included)
Power Method 24V Passive PoE In (Pairs 4, 5+; 7, 8 Return)
PoE Passthrough 24V Passive PoE Out (Pairs 4, 5+; 7, 8 Return)
Wind Loading 45.4 N @ 200 km/h (10.2 lbf @ 125 mph)
Wind Survivability 200 km/h (125 mph)
Operating Temperature -40 to 80° C (-40 to 176° F)
Operating Humidity 5 to 95% Noncondensing
Salt Fog Test IEC 68-2-11 (ASTM B117),
Equivalent: MIL-STD-810 G Method 509.5
Vibration Test IEC 68-2-6
Temperature Shock Test IEC 68-2-14
UV Test IEC 68-2-5 at 40° C (104° F)
Equivalent: ETS 300 019-1-4
Wind-Driven Rain Test ETS 300 019-1-4
Equivalent: MIL-STD-810 G Method 506.5
Mounting Pole-Mount (Kit Included)
Wall-Mount (Not Included)
ESD/EMP Protection ± 24kV Contact/Air
Certifications CE, FCC, IC
Operating Frequency (MHz)
Worldwide 5150 - 5875
US/CA U-NII-1 5150 - 5250
U-NII-2A 5250 - 5350
U-NII-2C 5470 - 5725
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 15/18
Operating Frequency (MHz)
U-NII-3 5725 - 5850
Management Radio (MHz)
Worldwide 2412 - 2472
US/CA 2412 - 2462
Safety Notices
1. Read, follow, and keep these instructions.
2. Heed all warnings.
3. Only use attachments/accessories specified by the manufacturer.
WARNING: Do not use this product in location that can be submerged by water.
WARNING: Avoid using this product during an electrical storm. There may be a remote
risk of electric shock from lightning.
Electrical Safety Information
1. Compliance is required with respect to voltage, frequency, and current requirements indicated
on the manufacturer’s label. Connection to a different power source than those specified may
result in improper operation, damage to the equipment or pose a fire hazard if the limitations are
not followed.
2. There are no operator serviceable parts inside this equipment. Service should be provided only
by a qualified service technician.
3. This equipment is provided with a detachable power cord which has an integral safety ground
wire intended for connection to a grounded safety outlet.
a. Do not substitute the power cord with one that is not the provided approved type. Never use
an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding
wire.
b. The equipment requires the use of the ground wire as a part of the safety certification,
modification or misuse can provide a shock hazard that can result in serious injury or death.
c. Contact a qualified electrician or the manufacturer if there are questions about the installation
prior to connecting the equipment.
d. Protective earthing is provided by Listed AC adapter. Building installation shall provide
appropriate short-circuit backup protection.
e. Protective bonding must be installed in accordance with local national wiring rules and
regulations.
Limited Warranty
ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and,
where applicable, specify arbitration instead of jury trials or class actions.
Compliance
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 16/18
FCC
Changes or modifications not expressly approved by the party responsible for compliance could
void the users authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions.
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operations of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
This radio transmitter has been approved by FCC.
ISED Canada
CAN ICES-3(A)/NMB-3(A)
This device complies with ISED Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
This radio transmitter has been approved by ISED Canada.
The device for operation in the band 5150-5250 MHz is only for indoor use to reduce the potential
for harmful interference to co-channel mobile satellite systems.
CAN ICES-3(A)/NMB-3(A)
Le présent appareil est conforme aux CNR d’ISDE Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. l’appareil ne doit pas produire de brouillage;
2. l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Le présent émetteur radio a été approuvé par ISDE Canada.
Les dispositifs fonctionnant dans la bande 5150-5250 MHz sont réservés uniquement pour une
utilisation à l’intérieur afin de réduire les risques de brouillage préjudiciable aux systèmes de
satellites mobiles utilisant les mêmes canaux.
IMPORTANT NOTE
Radiation Exposure Statement
This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 17/18
This equipment should be installed and operated with minimum distance 29 cm between the
radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
AVIS IMPORTANT
Déclaration sur l’exposition aux rayonnements
Cet équipement est conforme aux limites prévues pour l’exposition aux rayonnements dans un
environnement non contrôlé.
Lors de l’installation et de la mise en fonctionnement de l’équipement, assurez-vous qu’il y ait
une distance minimale de 29 cm entre l’élément rayonnant et vous.
Cet émetteur ne doit être installé à proximité d’aucune autre antenne ni d’aucun autre émetteur,
et ne doit être utilisé conjointement à aucun autre de ces appareils.
Australia and New Zealand
Warning: This equipment is compliant with Class A of CISPR 32. In a residential
environment this equipment may cause radio interference.
Brazil
Nota: Este equipamento não tem direito à proteção contra interferência prejudicial e não
pode causar interferência em sistemas devidamente autorizados.
CE Marking
CE marking on this product represents the product is in compliance with all directives that are
applicable to it.
Country List
AT BE BG CY CZ DE DK EE EL ES FI FR HR HU
IE IT LV LT LU MT NL PL PT RO SE SI SK UK
BFWA (Broadband Fixed Wireless Access) members noted in blue
Note: This device meets Max. TX power limit per ETSI regulations.
The following apply to products that operate in the 5 GHz frequency range:
Note: This device is restricted to indoor use only when operating in the 5150 - 5350 MHz
frequency range within all member states.
Note: All countries listed may operate at 30 dBm. BFWA member states may operate at
36 dBm.
NBE-5AC-Gen2 Quick Start Guide
19/08/2019 NBE-5AC-Gen2 Quick Start Guide
https://dl.ubnt.com/qsg/NBE-5AC-Gen2/NBE-5AC-Gen2_EN.html 18/18
Note: Operation in the 5.8 GHz frequency band is prohibited in BFWA member states.
Other countries listed may use the 5.8 GHz frequency band.
RoHS/WEEE Compliance Statement
Declaration of Conformity
Online Resources
© 2016-2019 Ubiquiti Inc. All rights reserved.
NBE-5AC-Gen2 Quick Start Guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18

Ubiquiti NBE-5AC-Gen2 Guide de démarrage rapide

Taper
Guide de démarrage rapide

dans d''autres langues