Bestway 58392E Le manuel du propriétaire

Catégorie
Accessoires de piscine hors terre
Taper
Le manuel du propriétaire
OWNER’S MANUAL
bestwaycorp.com/support
Visit Bestway YouTube channel
WE SUGGEST NOT TO RETURN
THE PRODUCT TO THE STORE
QUESTIONS? PROBLEMS?
MISSING PARTS?
For FAQ, Manuals, Videos Or
Spare Parts, Please Visit
bestwaycorp.com/support
V
i
s
i
t
w
w
w
.
b
e
s
t
w
a
y
c
o
r
p
.
c
o
m
/
s
u
p
p
o
r
t
f
o
r
h
e
l
p
58392E
2
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY, do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK. Connect only to a grounding type
receptacle.This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset
button.Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of an electric shock. Do not use this pump.
Disconnect the pump and have the problem corrected by a qualified service representative
before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances
closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential
bonding grid.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately. If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION - This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity. A permanently-installed
pool is constructed in or on the ground or in a building such that it cannot be readily
disassembled for storage.
CAUTION - For continued protection against possible electric shock this unit is
to bemounted to the base in accordance with the installation instructions.
IMPORTANT - Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK - When working with electricity, turn the electrical power off
at the circuit breaker and lock breaker door. Failure to do so will result in increased risk of
shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY.
DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related
to the validity of your plugs grounding. Handle the pump with care. Do not pull or carry the
pump by the power cord. Never pull a plug from the outlet by yanking the power cord.
Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer
service address listed on this manual for any manufacturing defect or missing parts at the
time of purchase. Verify that the equipment components represent the filter pump model
that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to position of pool
and pump so adequate ventilation, drainage, and access for cleaning is available. Never
place pump in an area that may accumulate water, or in an area where foot traffic will flow
around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your
filter pump. Unnecessary wear and tear may occur during periods of cold, heat and exposure
to sun. Whenever possible shelter the pump from these conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly of this product should only be performed by adults.
• THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A
GROUNDING TYPE RECEPTACLE.
CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE
ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE
WITH THE INSTALLATION INSTRUCTIONS.
WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground
4) Do Not Touch Plug With Wet Hands
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING: Any changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
FILTER PUMP
OWNER’S MANUAL
3
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY, do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK. Connect only to a grounding type
receptacle.This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset
button.Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of an electric shock. Do not use this pump.
Disconnect the pump and have the problem corrected by a qualified service representative
before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances
closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential
bonding grid.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately. If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION - This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity. A permanently-installed
pool is constructed in or on the ground or in a building such that it cannot be readily
disassembled for storage.
CAUTION - For continued protection against possible electric shock this unit is
to bemounted to the base in accordance with the installation instructions.
IMPORTANT - Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK - When working with electricity, turn the electrical power off
at the circuit breaker and lock breaker door. Failure to do so will result in increased risk of
shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY.
DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related
to the validity of your plugs grounding. Handle the pump with care. Do not pull or carry the
pump by the power cord. Never pull a plug from the outlet by yanking the power cord.
Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer
service address listed on this manual for any manufacturing defect or missing parts at the
time of purchase. Verify that the equipment components represent the filter pump model
that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to position of pool
and pump so adequate ventilation, drainage, and access for cleaning is available. Never
place pump in an area that may accumulate water, or in an area where foot traffic will flow
around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your
filter pump. Unnecessary wear and tear may occur during periods of cold, heat and exposure
to sun. Whenever possible shelter the pump from these conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly of this product should only be performed by adults.
• THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A
GROUNDING TYPE RECEPTACLE.
CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE
ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE
WITH THE INSTALLATION INSTRUCTIONS.
WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground
4) Do Not Touch Plug With Wet Hands
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING: Any changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
4
WARNING
IMPORTANT SAFETY INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always
be followed, including the following:
READ AND FOLLOW ALL
INSTRUCTIONS
WARNING - TO REDUCE THE RISK OF INJURY, do not permit children to
use this product unless they are closely supervised at all times.
WARNING - RISK OF ELECTRIC SHOCK. Connect only to a grounding type
receptacle.This product is provided with a ground-fault circuit-interrupter. If replacement of
the plug is needed, use only identical replacement parts.
WARNING: The unit is provided with a ground-fault circuit-interrupter (GFCI).
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset
button.Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a
ground current is flowing, indicating the possibility of an electric shock. Do not use this pump.
Disconnect the pump and have the problem corrected by a qualified service representative
before using.
CAUTION - To reduce the risk of electric shock the pool must be installed no
closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances
closer than 5 feet (1.5 m) from the pool.
WARNING: The pump is not intended to be bonded to the equipotential
bonding grid.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING - To reduce the risk of electric shock, replace damaged cord
immediately. If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
WARNING - To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; provide a properly located outlet.
CAUTION - This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable of being readily
disassembled for storage and reassembled to its original integrity. A permanently-installed
pool is constructed in or on the ground or in a building such that it cannot be readily
disassembled for storage.
CAUTION - For continued protection against possible electric shock this unit is
to bemounted to the base in accordance with the installation instructions.
IMPORTANT - Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRIC SHOCK - When working with electricity, turn the electrical power off
at the circuit breaker and lock breaker door. Failure to do so will result in increased risk of
shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY.
DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related
to the validity of your plugs grounding. Handle the pump with care. Do not pull or carry the
pump by the power cord. Never pull a plug from the outlet by yanking the power cord.
Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump.
NOTE: Please examine equipment before use. Notify Bestway at the customer
service address listed on this manual for any manufacturing defect or missing parts at the
time of purchase. Verify that the equipment components represent the filter pump model
that you had intended to purchase.
NOTE: Place pump on a solid and level ground. Pay attention to position of pool
and pump so adequate ventilation, drainage, and access for cleaning is available. Never
place pump in an area that may accumulate water, or in an area where foot traffic will flow
around the pool.
NOTE: Atmospheric conditions may affect the performance and life span of your
filter pump. Unnecessary wear and tear may occur during periods of cold, heat and exposure
to sun. Whenever possible shelter the pump from these conditions.
NOTE: Do not add chemicals in the filter pump.
NOTE: Assembly and disassembly of this product should only be performed by adults.
• THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3
• FOR USE WITH SWIMMING POOLS ONLY.
CAUTION: TO ENSURE CONTINUED PROTECTION AGAINST SHOCK
HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING.
WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A
GROUNDING TYPE RECEPTACLE.
CAUTION: THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY - DO
NOT USE WITH PERMANENTLY-INSTALLED POOLS.
CAUTION: CONNECT ONLY TO GROUNDING TYPE RECEPTACLE
PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER.
CAUTION: FOR CONTINUED PROTECTION AGAINST POSSIBLE
ELECTRIC SHOCK THIS UNIT IS TO BE MOUNTED TO THE BASE IN ACCORDANCE
WITH THE INSTALLATION INSTRUCTIONS.
WARNING - RISK OF ELECTROCUTION
1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin
2) Inspect Cord Before Using – Do Not Use If Cord Is Damaged.
3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground
4) Do Not Touch Plug With Wet Hands
5) Double Insulated – When Servicing Use Only Identical Replacement Parts.
6) Read Instruction Manual Before Using.
DO NOT REMOVE THIS TAG
SAVE THESE INSTRUCTIONS.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
WARNING: Any changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
5
POOL SUCTION FITTING
INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be
followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, AND UNDERSTAND
ALL INSTRUCTIONS AND WARNINGS.
- Any modification that increases the flow rate of the circulation system shall require
re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction
Outlet Fitting Assembly (SOFA) is not exceeded.
- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA
component shall be replaced before bathers are allowed to use the pool.
- Loose cover/grates shall be reattached before bathers are allowed to use the pool.
1. Replace suction fittings every 2 years.
2. The use of adhesives or other attachment methods
that prevent access to suction piping or SOFA
components requiring periodic servicing is prohibited.
3. Refer to the following diagram for each SOFA
component part instructions:
4. - Any field modification made to a SOFA not
authorized by the manufacturer’s installation
instructions shall void the SOFA certification.
- No modification shall be made to a SOFA structure
or flow path unless the new configuration has been
certified as new SOFA.
- Cover/grates and all other SOFA components shall
be replaced at or before the end of their service life and that service life begins the
month and year in which a SOFA component is installed with or without water.
5. Winterizing instructions. Dry the suction fittings completelyand store the product in a
dry room at a storage temperature of 15 ~ 40 .
6. Use the screwdriver (not included) to disassemble the suction fitting to clean or service.
- Cover/grate, including fasteners, shall be observed for damage or tampering each
operational day.
- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed
to use the pool.
- Loose cover/grates and associated components shall be reattached before bathers are
allowed to use the pool.
- SOFA components and fastener receptacles shall be clean and free of debris or
obstructions during installation of cover/grate and fasteners.
- Remember to hand-check cover/grate for snugness to the sump/ frame after
installation.
7. Before using the product, please check the integrity of the head of the suction fitting. If
the product is broken, cracked, or the color has significantly faded, please do not use it.
8. - All SOFAs shall be installed in accordance with the manufacturer’s installation
instructions.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified to the original SOFA.
- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool
is open to bathers.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the
finished surface of the pool in which the SOFA is installed
9.
Please research and download General Certificate of Conformity through
www.bestwaycorp.com
SAVE THESE INSTRUCTIONS
F4070-01
F4070-02
F4070-03
GFCI WARNING
WARNING: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE.
WARNING: DO NOT USE THE PUMP IF THE ABOVE TEST FAILS. FOR ASSISTANCE, PLEASE VISIT THE
SUPPORT SECTION ON OUR WEBSITE, WWW.BESTWAYCORP.COM.
NOTE: To prevent the risk of electrical shock, ensure your hands are completely dry when plugging-in the Filter Pump.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP - Make sure both the pool’s Inlet and Outlet valves
are fully covered by water before operating the Filter Pump.
6
POOL SUCTION FITTING
INSTRUCTIONS
When installing and using this equipment, basic safety precautions shall always be
followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
READ, FOLLOW, AND UNDERSTAND
ALL INSTRUCTIONS AND WARNINGS.
- Any modification that increases the flow rate of the circulation system shall require
re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction
Outlet Fitting Assembly (SOFA) is not exceeded.
- Missing, broken, or cracked cover/grates, sumps, mud-frames, or any other SOFA
component shall be replaced before bathers are allowed to use the pool.
- Loose cover/grates shall be reattached before bathers are allowed to use the pool.
1. Replace suction fittings every 2 years.
2. The use of adhesives or other attachment methods
that prevent access to suction piping or SOFA
components requiring periodic servicing is prohibited.
3. Refer to the following diagram for each SOFA
component part instructions:
4. - Any field modification made to a SOFA not
authorized by the manufacturer’s installation
instructions shall void the SOFA certification.
- No modification shall be made to a SOFA structure
or flow path unless the new configuration has been
certified as new SOFA.
- Cover/grates and all other SOFA components shall
be replaced at or before the end of their service life and that service life begins the
month and year in which a SOFA component is installed with or without water.
5. Winterizing instructions. Dry the suction fittings completelyand store the product in a
dry room at a storage temperature of 15 ~ 40 .
6. Use the screwdriver (not included) to disassemble the suction fitting to clean or service.
- Cover/grate, including fasteners, shall be observed for damage or tampering each
operational day.
- Missing, broken, or cracked cover/grates shall be replaced before bathers are allowed
to use the pool.
- Loose cover/grates and associated components shall be reattached before bathers are
allowed to use the pool.
- SOFA components and fastener receptacles shall be clean and free of debris or
obstructions during installation of cover/grate and fasteners.
- Remember to hand-check cover/grate for snugness to the sump/ frame after
installation.
7. Before using the product, please check the integrity of the head of the suction fitting. If
the product is broken, cracked, or the color has significantly faded, please do not use it.
8. - All SOFAs shall be installed in accordance with the manufacturer’s installation
instructions.
- No modification shall be made to a SOFA structure or flow path unless the new
configuration has been certified to the original SOFA.
- These SOFA-configuration specific flow ratings NOT be exceeded at any time the pool
is open to bathers.
- Cover/grates, when installed, shall not protrude more than 2 in. (51 mm) from the
finished surface of the pool in which the SOFA is installed
9.
Please research and download General Certificate of Conformity through
www.bestwaycorp.com
SAVE THESE INSTRUCTIONS
Installation Information label (copy)
Manufacturers name:
GOLEADER INDUSTRIES (JINHUA) CO., LTD.
Cover part number: F4070
Service life of the cover: 2 Years
Cover flow rating: 38 GPM
Installer needs to fill in the balance of the information
and permanently post it as near as feasible to the pump
control. Keep a copy of this information with the other
important pool related documents.
Configuration and installed orientation:_________
Location:_______
Installed Date:_________
P6124ASS16
P6916ASS16
P06188
P61318ASS16
P61408ASS16
P6005ASS16
P6029ASS16
P6019ASS16
P6517ASS16
P61731ASS18
P05427
58095
P61733ASS18
P05640
P6029ASS16
P6029ASS16
7
1 2
3 4
P6517ASS16
P6019ASS16
P6019ASS16
P61731ASS18
P05427
P61733ASS18
58095
P6029ASS16
P05640
P6019ASS16
P6517ASS16
P6124ASS16
P6005ASS16
P6916ASS16
P61408ASS16
P06188
P61318ASS16
A
1
1
1
1
3
1
2
2
5
2
2
1
2
1
B
1
1
1
1
3
1
2
2
4
2
0
1
2
0
A
B
B
B
AB
B
A
B
X3
X1 X2
A
A
B
B
B
A
B
A
B
A
B
B
A
B
B
P61408ASS16
P6124ASS16
P06188
PEDESTAL FIXING Fig.1
The filter pump must be vertically fixed on ground or a certain
pedestal made of wood or concrete before use. There should
be two holes 7mm in diameter on the pedestal, the space
between which should be 256mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All
the pedestal parts should weigh over 18kgs at least to prevent
the pump from accidental falling.
OPERATION
1) Open/unscrew the Air Purge Valves on the Filter Pump; air is released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valves, close both the Air Purge Valves and wipe away any water.
3) Test the GFCI plug.
4) Start the Filter Pump by turning on the switch to the "I" position.
6
6
256
270
300
450
Fig.1
B
A
P61318ASS16 P06188
P6916ASS16
8
9
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE
BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Stop water flowing to the Filter Pump refer to pool’s manual.
3) Unscrew the Filter Cap Retainer and remove the Filter Cap.
4) Clean the Filter Cartridge with a garden hose. If filter cartridge remains soiled or discolored, it is necessary to replace it
with a new one.
5) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
6) Check that the Filter Cap Seal is in place.
7) Replace the Filter Cap and screw the Filter Cap Retainer into position.
8) Open the Valve A and B.
9) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use.
IMPORTANT: To ensure pool water stays clean,
please clean the filter cartridge every day. For sanitary reasons
we suggest replacing the Filter Cartridge with a new one every
two weeks.
PUMP STORAGE
1) Unplug the Filter Pump.
2) Stop water flowing into the Filter Pump and to remove the Filter
Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of the reach of children.
Storage temperature: 4-40OC (39.2-104OF)
7) Drain the pool according to the Pool Owner’s Manual.
PUMP WARRANTY
For information concerning pump warranty please visit our website at: www.bestwaycorp.com
To ensure pool water stays
clean, please clean the filter
cartridge every day and
change when required.
Each LED indicator represents 2 hours of working time. You can push the
Set Working Hours Button to adjust the desired time.
IMPORTANT:
1. After setting the run time, the pump will restart automatically at the same
time the following day.
2. In case of a power outage or the GFCI being unplugged, the running time
of the product will be reset to a 10 hour default and the previous set will be
deleted.
3. After finishing the working time, the GFCI goes into stand-by mode. During
this time, all LED indicators will be off.
4. Pushing the test button on the GFCI does not stop the timer. To stop the
timer, you have to unplug the GFCI.
For support please visit us at:
bestwaycorp.com/support
©2021 Bestway Inflatables & Material Corp.
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle Rechte vorbehalten/Tutti i diritti riservati
Trademarks used in some countries under license from/
Marques utilisées dans certains pays sous la licence de/
Marcas comerciales utilizadas en algunos países bajo la licencia de/
Die Warenzeichen werden in einigen Ländern verwendet unter Lizenz der/
Marchi utilizzati in alcuni paesi concessi in licenza a
Bestway Inflatables & Material Corp., Shanghai, China
Manufactured, distributed and represented in the European Union by/
Fabriqués, distribués et représentés dans l’Union Européenne par/Fabricado, distribuido y representado en la Unión Europea por/
Hergestellt, vertrieben und in der Europäischen Union vertreten von/Prodotto, distribuito e rappresentato nell'Unione Europea da
Bestway (Europe) S.r.l., Via Resistenza, 5, 20098 San Giuliano Milanese (Milano), Italy
Distributed in Latin America by/Distribué en Amérique latine par/Distribuido en Latinoamérica por/Distribuído na América Latina por
Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile
Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit 2/98-104 Carnarvon St Silverwater, NSW 2128, Australia
Tel: Australia: (+61) 29 0371 388; New Zealand: 0800 142 101
Distributed in United Kingdom by Bestway Corp UK Ltd. 8 Wentworth Road, Heathfield Industrial Estate, Newton Abbot, Devon, TQ12 6TL
Exported by/Exporté par/Exportado por/Exportiert von/Esportato da
Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited
Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon, Hong Kong
Tel: +86 21 69135588 (For U.S. and Canada)
www.bestwaycorp.com
303021275892
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Bestway 58392E Le manuel du propriétaire

Catégorie
Accessoires de piscine hors terre
Taper
Le manuel du propriétaire

dans d''autres langues