Modern Forms WS-W10214 Cupid Mode d'emploi

Taper
Mode d'emploi
INSTALLATION INSTRUCTION
102 - Outdoor Wall Sconce
WS-W10214
HARDWARE
Wire Connector
Qty: 3pcs+1 Extra
Mounting Screw
Qty:1 Extra
Rubber Gasket
Qty:1 Extra
B
AC
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning.
Read all instructions before installing.
System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
Retain installation instructions for future maintenance reference.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal
areas clean all external surfaces of the fixture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
Lisez toutes les instructions avant l’installation.
Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux
règlements locaux.
Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec
un chiffon humide.
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
INSTALLATION INSTRUCTION
102 - Outdoor Wall Sconce
WS-W10214
PREPARATION
MOUNTING THE FIXTURE (Fig. 1)
CONNECTING THE WIRES (Fig. 2)
COMPLETING THE INSTALLATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
3. Remove the mounting screw (B) and the rubber gasket (C) from the mounting back plate.
4. Secure the mounting plate to the junction box using junction box screws. The side of the mounting back plate marked “GND” must face out.
5. Connect the fixture’s wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A) are secured. If your outlet box has a
green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate
using the “GND” screw provided. After wires are connected, tuck them carefully inside the junction box.
6. Secure the fixture to the mounting back plate using the mounting screw (B) and the rubber gasket (C).
7. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape Fig.3.
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Fig. 1
"
1/4
4
"
3/4
1
"
1/2
1
"
1/4
4
Back Plate Dimensions
7MBC151106
Junction Box
Caulking
Fig. 3 Sealing
Junction Box Screw
Rubber Gasket
C
Mounting Screw
B
Backplate
Junction Box
Wire Connector
A
Black WireWhite
Wire
Ground
Wire
G
ND
Screw
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement progr
  • Page 1 1
  • Page 2 2

Modern Forms WS-W10214 Cupid Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues