Robustel EG5120 Hardware Manual Manuel utilisateur

Taper
Manuel utilisateur
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 1/9
EG5120
Hardware Manual
Version: 1.0.2
Date: Nov. 23, 2022
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 2/9
Regulatory and Type Approval Information
Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits
Radio Specifications for Europe
RF technologies
2G, 3G, 4G, 5G, GNSS, Wi-Fi*, BLE*
Cellular
Frequency *
2G: GSM: B2/B3/B5/B8
3G: WCDMA: B1/B2/B4/B5/B6/B8/B19
4G: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/
B19/B20/B25/B26/B28/B29/B30/B32/B66/B71
LTE TDD: B34/B38/B39/B40/B41/B42/B43/B48
LAA: B46 (only supports 2 x 2 MIMO)
5G: NR SA/NSA:
n1/n2/n3/n5/n7/n8/n12/n13/n14/n20/n25/n26/n28/n29/
n30/n38/n40/n41/n48/n66/n71/n75/n76/n77/n78/n79
Wi-Fi Frequency
2.4 GHz: 2.412 ~ 2.484 GHz
5 GHz: 4.915 ~ 5.925 GHz
BLE Frequency
2402 ~ 2480 MHz
Max RF power
33 dBm±1dB@GSM, 23 dBm±1dB@WCDMA, 23 dBm±1dB@LTE, 23 dBm±1dB@NR, 18
dBm@WiFi, 4 dBm@BLE
* May vary on difference models.
Note: Operation of 5150 ~ 5250 MHz frequency range is restricted to indoor use only.
Name of
the Part
Hazardous Substances
(Pb)
(Hg)
(Cd)
(Cr(VI))
(PBDE)
(DEHP)
(DBP)
(DIBP)
Metal
parts
o
o
o
o
-
-
-
-
Circuit
modules
o
o
o
o
o
o
o
o
Cables
and cable
assemblie
s
o
o
o
o
o
o
o
o
Plastic
and
polymeric
parts
o
o
o
o
o
o
o
o
o:
Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is
below the limit requirement in RoHS2.0.
X:
Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this
part might exceed the limit requirement in RoHS2.0.
-:
Indicates that it does not contain the toxic or hazardous substance.
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 3/9
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the
device.
Lémetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation,
Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. Lexploitation
est autorisée aux deux conditions suivantes :
(1) Lappareil ne doit pas produire de brouillage;
(2) Lappareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
FCC& IC Radiation Exposure Statement
This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your
body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Déclaration d’IC sur l’exposition aux radiations
Cet équipement est conforme aux limites d’exposition aux radiations définies par le Canada pour des
environnements non contrôlés. Cet équipement doit être installé et utilisé à une distance minimum de 20 cm entre
l’antenne et votre corps.
Cet émetteur ne doit pas être installé au même endroit ni utilisé avec une autre antenne ou un autre émetteur.
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 4/9
Simplified EU Declaration of Conformity
We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou,
China, declare that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is
available at the following internet address:
www.robustel.com/certifications/
Safety Information
General
- The router generates radio frequency (RF) power. When using the router, care must be taken on safety issues
related to RF interference as well as regulations of RF equipment.
- Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is prohibited.
- Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical
equipment. The antenna of the router should be away from computers, office equipment, home appliance, etc.
- An external antenna must be connected to the router for proper operation. Only uses approved antenna with the
router. Please contact authorized distributor on finding an approved antenna.
RF Exposure
- This device meets the official requirements for exposure to radio waves. This device is designed and manufactured
not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies.
- The device must be used with a minimum separation of 20 cm from a person’s body to ensure compliance with RF
exposure guidelines. Failure to observe these instructions could result in your RF exposure exceeding the applicable
limits.
Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open.
Router may be used at this time.
The symbol indicates that the product should not be mixed with general household waste but must be sent to
separate collection facilities for recovery and recycling.
The symbol indicates that the product meets the requirements of the applicable EU directives.
The symbol indicates that the product meets the requirements of the relevant UK legislation.
Related download link
Find more product documents or tools at:
www.robustel.com/en/documentations/
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 5/9
Technical Support
Tel: +86-20-82321505
Email: support@robustel.com
Web: www.robustel.com
Document History
Updates between document versions are cumulative. Therefore, the latest document version contains all updates
made to previous versions.
Date
Firmware Version
Document Version
Change Description
July. 6, 2022
2.0.0
1.0.0
Initial release.
Nov. 1, 2022
2.0.0
1.0.1
Added description of 4-in-1 antenna installation.
Nov. 23, 2022
2.0.0
1.0.2
Added declaration for product.
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 6/9
Overview
EG5120 is a new generation of industrial edge computing gateway, supporting global 5G/4G/3G/2G networks for
cellular backhaul, with a fully-fledged Debian 11(bullseye) based operating system able to support thousands of
existing or new ARMv8 (Raspberry Pi compatible) based applications.
Package Checklist
Before commencing installation ensure your package has the following components:
Device
2PIN Terminal
Block
6PIN Terminal
Block
8PIN Terminal
Block
Mounting Kit
RCMS Card
Quick Start Guide
Card
Cellular Antenna
(Optional)
Power Supply
(Optional)
Wi-Fi Antenna
(Optional)
Note: The accessories could be different on specific order.
Panel Layout (May vary on different models)
Top View Front View Bottom View
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 7/9
Interface Descriptions
1. Serial Ports. Two software configurable serial
ports, could be configured as RS232 or RS485.
Name
RS232 Mode
RS485 Mode
TXD1/A1
data sending
RS485_A
RXD1/B1
data receiving
RS485_B
GND1
Ground
Ground
TXD2/A2
data sending
RS485_A
RXD2/B2
data receiving
RS485_B
GND2
Ground
Ground
2. Ethernet Ports. Two Ethernet ports, both of them
could be configured as WAN or LAN.
LED
Description
Activity
On, blinking
Transmitting data
Off
No activity
Link
Off
Link off
On
Link on
3. Reset Button.
Press and Release
RUN LED
Action
Hold less than 3
seconds
On then blink
regularly
Reset
Hold more than 3
seconds but less
than 10 seconds
Blink regularly
->
blink rapidly
Restore to
factory setting
and reboot
Hold more than
10 seconds
Solid on for 5
seconds then
blink regularly
Do nothing
4. Digital Input and Output Ports. Two sets of digital
inputs and two sets of digital outputs. Some
applications for reference are as below:
Note: The external power supply DC voltage range is 5V~30V, 0.1A max.
5. LED Indicators.
LED
Description
RUN
On, solid
Gateway system is initializing
On, blinking
Gateway starts operating
Off
Gateway is powered off
Note: The RUN LEDs color is green
MDM
Color
With 4G Module:
2G: Red, 3G: Yellow, 4G: Green
With 5G Module:
3G: Red, 4G: Yellow, 5G: Green
On, blinking
Link connection is working
Off
Link connection is not working
Green
Strong signal
Yellow
Medium signal
Red
Weak or no signal
Note: The USR LED is defined by user via web UI to
specify different status, the details see the following
sheet.
USR
Description
None
Off
No definition
Net
On, solid
With 4G Module:
Connection to the 4G network
is established
With 5G Module:
Connection to the 5G network
is established
On, blinking
With 4G Module:
Connection to the 2G or 3G
network is established
With 5G Module:
Connection to the 4G or 3G
network is established
Off
No connection
SIM
On, solid
Main card is being used
On, blinking
Backup card is being used
IPsec
On, solid
IPsec connection is established
Off
IPsec connection is not
established
Open
VPN
On, solid
OpenVPN connection is
established
Off
OpenVPN connection is not
established
Note: The USR LEDs color is green.
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 8/9
Hardware Installation
1. SIM Card Installation. Remove the SIM card cover
to insert the SIM cards into the device, then screw
up the cover.
2. Antenna Installation. Rotate the antenna into the
antenna connector accordingly. For 5G 4-IN-1
combo antenna, LHM# cable need to be
connected to ANT1 and ANT2 while the MH# cable
need to be connected to ANT0 and ANT3. GPS
function is available when using the 4 in 1 combo
antenna.
3. Terminal Block Installation. Insert the 6PIN and
8PIN terminal blocks into the interfaces
connector, then can connect the devices or
sensors to the gateway with wires via
corresponding interfaces e.g. RS232/RS485,
DIDO...
4. Power Supply installation. Insert the power
supply cord into the corresponding terminal block
if needed, then insert the terminal block into the
power connector.
5. DIN Rail Mounting. Use 2 M3 screws to fix the DIN
rail to the device, then hang the DIN rail on the
mounting bracket.
6. Grounding the Device. Grounding will help to
prevent the noise effect due to electromagnetic
interference (EMI). Connect the device to the site
ground wire by the grounding screw before
powering on.
Robustel EG5120 Hardware Manual
RT090_HM_EG5120 9/9
Login to the Device
1. Connect the gateways Ethernet port to a PC with
a standard Ethernet cable.
2. Before logging in, manually configure the PC with
a static IP address on the same subnet as the
gateway address, click and configure "Use the
following IP address".
3. To enter the gateway's web interface, type
http://192.168.0.1 into the URL field of your
Internet browser.
4. Use login information shown in the product label
when prompted for authentication.
5. After logging in, the home page of the web
interface is displayed, then you can view system
information and perform configuration on the
device.
6. The automatic APN selection is ON by default, if
need to specify your own APN, please go to the
menu Interface->Cellular->Advanced Cellular
Setting->General Settings to finish the specific
setting.
7. For more configuration details please refer to
RT104_SM_RobustOS Pro Software Manual.
(END)
Support: support@robustel.com
Website: www.robustel.com
©2022 Guangzhou Robustel Co.,Ltd.
All rights reserved. Subject to change without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Robustel EG5120 Hardware Manual Manuel utilisateur

Taper
Manuel utilisateur

dans d''autres langues