Concentric Vent Termination Kit for Condensing Furnaces
SPECIAL VENTING REQUIREMENTS FOR
INSTALLATIONS IN CANADA
Installation in Canada must conform to the requirements
of CSA B149 code. Vent systems must be composed of
pipe, fittings, cements, and primers listed to ULC S636. This
concentric vent termination kit has been certified to ULC
S636 for use vent components which have been certified
to this standard. The primer and cement must be of the
same manufacturer as the vent system. Do not mix primers
and cements from one manufacturer with a vent system
from a different manufacturer. Follow the manufacturer’s
instructions in the use of primer and cement and never
use primer or cement beyond its expiration date.
The safe operation, as defined by ULC S636, of the vent
system and this termination kit is based on following these
installation instructions, the vent system manufacturer’s
installation instructions, and proper use of primer and
cement. Acceptability under Canadian standard CSA B149
is dependent upon full compliance with all installation
instructions. Under this standard, it is recommended
that the vent system be checked once a year by qualified
service personnel. The authority having jurisdiction (gas
inspection authority, municipal building department, fire
department, etc) should be consulted before installation
to determine the need to obtain a permit.
CONSIGNES SPÉCIALES POUR
L’INSTALLATION DE VENTILLATION AU
CANADA
L’installation faite au Canada doit se conformer aux
exigences du code CSA B149. Ce systême de ventillation
doit se composer de tuyaux, raccords, ciments et apprêts
conformes au ULC S636. Ce systême de ventillation
concentrique a été certifié ULC S636 pour être utilisé avec
les composantes qui sont certifiés. L’apprêt et le ciment
doivent être du même manufacturier que le systême de
ventillation; ne pas mélanger l’apprêt et le ciment d’un
manufacturier avec le systême de ventillation d’un autre
manufacturier. Bien suivre les indications du manufacturier
lors de l’utilisation de l’apprêt et du ciment et ne pas utiliser
ceux--ci si la date d’expiration est atteinte.
Le bon fonctionnement de ce systême de ventillation
est conditionnel à l’installation tel que défini par le ULC
S636 c’est à dire: bien suivre les consignes ci--haut
mentionnées ainsi que les instructions du manufacturier
et aussi une bonne utilisation de l’apprêt et du ciment.
L’acceptation du standard Canadien CSA B419 est
directement relié à l’installation conforme aux instructions
ci--haut mentionnées. Le standard Canadien recommande
l’ inspection par un personel qualifié et ce, une fois par
année. Les autoritées ayant juridiction (inspecteurs de gas,
inspecteurs en bâtiments, département des incendies,
etc) devraient être consultées avant l’installation afin de
déterminer si un permis est requis.
IMPORTANT SAFETY INFORMATION
Please read all instructions before installing this kit. Pay
attention to all safety warnings and any other special
notes highlighted in the manual. Safety markings are
used frequently throughout this manual to designate a
degree or level of seriousness and should not be ignored.
WARNING indicates a potentially hazardous situation that
if not avoided, could result in personal injury or death.
CAUTION indicates a potentially hazardous situation
that if not avoided, may result in minor or moderate injury
or property damage.These instructions are intended to
assist qualified individuals in the proper installation of
the concentric vent termination kit. If these instructions
differ from those packaged with the furnace, follow these
instructions. READ ALL INSTRUCTIONS CAREFULLY
BEFORE STARTING THE INSTALLATION.
WARNING:
ELECTRICAL SHOCK, FIRE OR EXPLOSION
HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
• Before servicing, disconnect all electrical
power to the indoor blower.
• Whenservicingcontrols,labelallwiresprior
to disconnecting. Reconnect wires correctly.
• Verifyproperoperationafterservicing.
WARNING:
The information listed in this manual must
be followed during the installation of this kit.
Unqualified individuals should not attempt
to interpret these instructions or install this
equipment. If you do not posses mechanical skills
or tools, call your local dealer for assistance.
Installing and servicing heating equipment can be
hazardous due to gas and electrical components.
Observe all precautions in the literature, and on
tags and labels attached to the unit. Follow all
safety codes. Wear glasses and work gloves, and
have a fire extinguisher available.
Failure to follow safety recommendations could
result in possible damage to the equipment,
serious personal injury or death.
INSTALLATION INSTRUCTIONS