INSTALLATION
INSTRUCTIONS
Commercial Stacked Dryer
Gas (120-Volt, 60-Hz)
or Electric
(120/240-Volt, 60-Hz)
www.whirlpoolcommerciallaundry.com
W10761037A
W10761038A – SP
INSTRUCTIONS
D’INSTALLATION
Sécheuse à usage
commercial superposée
à gaz (120 Volts, 60 Hz)
TABLE OF CONTENTS
Page
Dryer Safety ............................................................................. 2
Tools & Parts ........................................................................... 5
Dimensions/Clearances ........................................................ 6
Location Requirements ......................................................... 7
Gas Dryer Electrical Requirements ..................................... 8
Gas Requirements ................................................................. 9
Electric Dryer Electrical Requirements ............................. 10
Dryer Venting Requirements .............................................. 12
Gas Supply Connection ...................................................... 14
Installing Coin Slide and Coin Box ...................................... 16
Electric Dryer Electrical Connections ............................... 17
Leveling ................................................................................. 21
Complete Installation ........................................................... 22
Reversing Dryer Door Swing ............................................... 23
Changing to a 30- or 60-Minute Timing Cam ..................... 24
Maintenance Instructions .................................................... 25
If You Need Assistance ........................................................ 25
Warranty ............................................................................... 26
TABLE DES MATIÈRES
Page
Sécurité de la sécheuse ........................................................ 27
Outils et pièces ..................................................................... 30
Dimensions/Distances de dégagement ............................. 31
Exigences de l’emplacement ............................................... 32
Exigences électriques pour la sécheuse à gaz .................. 33
Exigences de gaz................................................................... 34
Exigences concernant l’évacuation de la sécheuse ......... 35
Raccordement à la canalisation de gaz ............................. 37
Installation de la glissière à monnaie
et de la caisse à monnaie .................................................... 39
Nivellement ............................................................................40
Achever l’installation ............................................................. 41
Inversion du sens d’ouverture de la porte ..........................42
Installation d’une came de minutage
de 30 ou 60 minutes ..............................................................43
Instructions d’entretien .........................................................44
Si vous avez besoin d’assistance ........................................44
Garantie ................................................................................. 45
Actual unit may or may not contain doors
with windows, depending on model.
Selon le modèle, le présent appareil
n’offre peut-être pas de hublot de porte.
2
DRYER SAFETY
It is recommended that the owner post, in a prominent location, instructions for the customer’s use in the event the customer
smells gas. This information should be obtained from your gas supplier.
Post the following warning in a prominent location.
3
DRYER SAFETY
IMPORTANT: When discarding or storing your old clothes dryer, remove the door.
4
DRYER SAFETY
Clean dryer lint screen before or after each load.
Do not use this dryer without the lint screen in place.
Do not repair or replace any part of the dryer or attempt
any servicing unless specically recommended in this
Installation Instructions or in published user-repair
instructions that you understand and have the skills
to carry out.
Do not use fabric softeners or products to eliminate static
unless recommended by the manufacturer of the fabric
softener or product.
Do not use heat to dry articles containing foam rubber
or similarly textured rubber-like materials.
The nal part of a tumble dryer cycle occurs without heat
(cool-down cycle) to ensure that the articles are left at
a temperature that ensures that the items will not be
damaged.
WARNING: Never stop a tumble dryer before the end
of the drying cycle unless all items are quickly removed
and spread out so that the heat is dissipated. (Avoids risk
of spontaneous combustion).
Keep area around the exhaust opening and adjacent
surrounding areas free from the accumulation of lint,
dust, and dirt.
The interior of the dryer and dryer exhaust vent should
be cleaned periodically by qualied service personnel.
See “Electrical Requirements” section for grounding
instructions.
IMPORTANT SAFETY INSTRUCTIONS
WARNING: To reduce the risk of re, electric shock, or injury to persons when using the dryer, follow basic precautions, including
the following:
SAVE THESE INSTRUCTIONS
Read all instructions before using the dryer.
This dryer is intended only for drying clothes and textiles
that have been washed in water. Do not use for any other
purpose.
WARNING: If you smell gas, do not use the dryer or any
electrical equipment nearby. Warn other people to clear
the area. Contact the dryer owner immediately.
Do not place items exposed to cooking oils in your dryer.
Items contaminated with cooking oils may contribute to a
chemical reaction that could cause a load to catch re.
Do not dry articles that have been previously cleaned
in, washed in, soaked in, or spotted with gasoline,
dry-cleaning solvents, other ammable, or explosive
substances as they give off vapors that could ignite
or explode.
Do not dry unwashed items in the dryer.
Do not allow children to play on or in the dryer. Close
supervision of children is necessary when the dryer is
used near children.
Before the dryer is removed from service or discarded,
remove the doors to the dryer compartment.
Do not reach into the dryer if the drum is moving.
Do not open door while dryer is in operation. It will stop.
Do not install or store the dryer where it will be exposed
to the weather.
Do not tamper with controls.
5
Tools Needed:
8" (200 mm) 8" (200 mm) or 10" (250 mm) Flat-Blade Screwdriver Phillips Screwdriver
or 10" (250 mm) Adjustable Wrench
Pipe Wrench That Opens to 1" (25 mm)
Torx
®†
T-20 Security 1" (25 mm) Hex-Head 5⁄16" (8 mm) Socket Wrench Pliers (that open to
Screwdriver or Bit Socket Wrench 1
9
/
16
" [39 mm])
Level Utility Knife 1/4" (6 mm) Nut Driver 27" (686 mm)
Wood Block
Caulk Gun and Caulk Vent Clamps Pipe-Joint Compound Putty Knife
(for installing new exhaust vent) Suitable for Gas Type
Flashlight (optional) 1" (25 mm) Ruler or Measuring Tape
Open-End Wrenches
TOOLS & PARTS
Parts Supplied:
10-32 x 5/16" Serrated Screws (4) Security Cotter Pins (2)
†® TORX and T-20 are registered trademarks of Acument Intellectual Properties, LLC.
6
DIMENSIONS/CLEARANCES
Dimensions
Clearances
Front View
Recessed Front View Recessed Side View
Side View Back View
7
Your dryer can be installed in a basement, laundry room,
or recessed area.
Companion appliance location requirements should also
be considered.
IMPORTANT:
Do not install or store the dryer where it will be exposed
to the weather. Proper installation is your responsibility.
This dryer must not be installed in a closet with a door.
You will need:
A grounded electrical outlet located within 6 ft. (1.8 m) of
where the power cord is attached to the back of the dryer.
See “Electrical Requirements.”
A level oor with a maximum slope of 1" (25 mm) under
entire dryer. Installing the dryer on soft oor surfaces,
such as carpets or surfaces with foam backing, is not
recommended.
Dryer installation clearances
The location must be large enough to allow the dryer door
to be fully opened.
Additional spacing should be considered for ease of
installation and servicing. The door opens more than 180°.
Additional clearances might be required for wall, door,
and oor moldings.
Additional spacing of 1" (25 mm) on all sides of the dryer
is recommended to reduce noise transfer.
LOCATION REQUIREMENTS
When installing a gas dryer:
IMPORTANT: Observe all governing codes and ordinances.
Check code requirements: Some codes limit or do not
permit installation of clothes dryers in garages, closets,
or sleeping quarters. Contact your local building inspector.
Make sure that lower edges of the cabinet, plus the back
and bottom sides of the dryer, are free of obstructions to
permit adequate clearance of air openings for combustion
air. See “Recessed Area Installation Instructions” below
for minimum spacing requirements.
Recessed Area Installation Instructions
This dryer may be installed in a recessed area. For recessed
area installations, minimum clearances can be found on the
warning label on the rear of the dryer or in “Dimensions/
Clearances.”
The installation spacing is in inches and is the minimum
allowable. Additional spacing should be considered for ease
of installation, servicing, and compliance with local codes
and ordinances.
The dryer must be exhausted outdoors.
8
Gas Dryer Grounding
IMPORTANT: The dryer must be electrically grounded in
accordance with local codes and ordinances or, in the absence
of local codes, with the National Electrical Code, ANSI/NFPA
70, latest edition, or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrical installer determine
that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
Do not ground to a gas pipe.
Do not have a fuse in the neutral or ground circuit.
A 120 volt, 60 Hz, AC only, 15- or 20-amp, fused electrical
circuit is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this dryer be provided.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
Check with a qualied electrician if you are not sure
the dryer is properly grounded.
GAS DRYER ELECTRICAL REQUIREMENTS
9
IMPORTANT: Observe all governing codes and ordinances.
This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1/NFPA 54 or CAN/CSA B149.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park, Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
The design of this dryer has been certied by CSA International
for use at altitudes up to 10,000 feet (3048 m) above sea level
at the B.T.U. rating indicated on the model/serial plate. Burner
input adjustments are not required when the dryer is operated
up to this elevation.
When installed above 10,000 feet (3048 m), a four percent
(4%) reduction of the burner B.T.U. rating shown on the model/
serial plate is required for each 1,000 foot (305 m) increase in
elevation. For assistance when converting to other gas types
and/or installing above 10,000 feet (3048 m) elevation, contact
your local service company.
Gas Supply
GAS REQUIREMENTS
10
Electric Dryer GroundingIt is your responsibility:
To contact a qualied electrical installer.
To be sure that the electrical connection is adequate and in
conformance with the National Electrical Code, ANSI/NFPA
70-latest edition and all local codes and ordinances.
The National Electrical Code requires a 4-wire power supply
connection for homes built after 1996, dryer circuits involved
in remodeling after 1996, and all mobile home installations.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch
Park, Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240
volt, 60 Hz., AC only electrical supply (or 3 or 4 wire,
120/208 volt electrical supply, if specied on the serial/
rating plate) on a separate 30-amp circuit, fused on both
sides of the line. A time delay fuse or circuit breaker is
recommended. Connect to an individual branch circuit.
Do not have a fuse in the neutral or grounding circuit.
Do not use an extension cord.
If codes permit and a separate ground wire is used, it is
recommended that a qualied electrician determine that
the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type
of electrical connection you will be using and follow the
instructions provided for it here.
This dryer is manufactured ready to install with a 3-wire
electrical supply connection. The neutral ground conductor
is permanently connected to the neutral conductor (white
wire) within the dryer. If the dryer is installed with a 4-wire
electrical supply connection, the neutral ground conductor
must be removed from the external ground connector (green
screw), and secured under the neutral terminal (center or
white wire) of the terminal block. When the neutral ground
conductor is secured under the neutral terminal (center or
white wire) of the terminal block, the dryer cabinet is isolated
from the neutral conductor.
If local codes do not permit the connection of a neutral
ground wire to the neutral wire, see “Optional 3-wire
connection” section.
A 4-wire power supply connection must be used when the
appliance is installed in a location where grounding through
the neutral conductor is prohibited. Grounding through the
neutral is prohibited for (1) new branch-circuit installations
and (2) areas where local codes prohibit grounding through
the neutral conductor.
ELECTRIC DRYER ELECTRICAL REQUIREMENTS
(U.S.A. ONLY) (ÉTATS-UNIS SEULEMENT)
11
Electric Dryer Power Supply Cord
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt
minimum. The cord should be type SRD or SRDT and be at
least 4 ft. (1.22 m) long. The wires that connect to the dryer
must end in ring terminals or “U” shaped spade terminals
with upturned ends.
A UL listed strain relief.
If your outlet looks like this:
4-Wire
Receptacle
(14-30R)
3-Wire
Receptacle
(10-30R)
Then choose a 4-wire power supply cord with ring
or spade terminals and UL listed strain relief. The
4-wire power supply cord, at least 4 ft. (1.22 m)
long, must have four 10-gauge copper wires and
match a 4-wire receptacle of NEMA Type 14-30R.
The ground wire (ground conductor) may be either
green or bare. The neutral conductor must be
identied by a white cover.
Then choose a 3-wire power supply cord with ring
or spade terminals and UL listed strain relief. The
3-wire power supply cord, at least 4 ft. (1.22 m)
long, must have three 10-gauge copper wires and
match a 3-wire receptacle of NEMA Type 10-30R.
If your outlet looks like this:
ELECTRIC DRYER ELECTRICAL REQUIREMENTS
(U.S.A. ONLY) (ÉTATS-UNIS SEULEMENT)
Direct Wire
If connecting by direct wire:
Power supply cable must match power supply (4-wire or 3-wire)
and be:
Flexible armored cable or nonmetallic sheathed copper
cable (with ground wire), covered with exible metallic
conduit. All current-carrying wires must be insulated.
10-gauge solid copper wire (do not use aluminum).
At least 5 ft. (1.52 m) long.
12
DRYER VENTING REQUIREMENTS
WARNING: To reduce the risk of re, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or exible metal vent shall be used for
exhausting.
Only a 4" (102 mm) heavy, metal exhaust vent and clamps
may be used.
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
Must be fully extended and supported in nal dryer location.
Remove excess to avoid sagging and kinking that may result
in reduced airow and poor performance.
Do not install in enclosed walls, ceilings, or oors.
The total length should not exceed 7
3
4
ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not
plugged with lint. Replace plastic or metal foil vents with rigid
metal or exible metal vents. Review “Vent System Chart” and
if necessary, modify existing vent system to achieve best drying
performance.
4"
(102 mm)
4" (102 mm) Heavy, Metal Exhaust Vent
Elbows:
45° elbows provide better airow than 90° elbows.
Clamps:
Use clamps to seal all joints.
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into interior of duct
and catch lint. Do not use duct tape.
Better
Good
13
4" (102 mm) Diameter Exhaust Hoods
Vent Hoods
DRYER VENTING REQUIREMENTS
Exhaust hood must be at least 12" (305 mm) from the ground
or any object that may be in the path of the exhaust (such as
owers, rocks, bushes, or snow).
Maximum Vent Length/Vent Connection
Maximum length of vent system depends upon the type of vent
used, number of elbows, and type of exhaust hood.
Vent System Chart (Rigid Metal Vent)
No. of 90˚ Turns
Box and
Louvered Hood
Angled Hood
0 64 ft. (19.5 m) 58 ft. (17.7 m)
1 54 ft. (16.5 m) 48 ft. (14.6 m)
2 44 ft. (13.4 m) 38 ft. (11.6 m)
3 35 ft. (10.7 m) 29 ft. (8.8 m)
4 27 ft. (8.2 m) 21 ft. (6.4 m)
For vent systems not covered by the vent specication chart,
see your parts distributor.
Provision must be made for enough air for combustion
and ventilation. (Check governing codes and ordinances.)
See “Recessed Area Installation Instructions” in the “Location
Requirements” sections.
A 4" (102 mm) outlet hood is preferred. However, a 2
1
2
"
(64 mm) outlet exhaust hood may be used. A 2
1
2
" (64 mm)
outlet creates greater back pressure than other hood types.
For permanent installation, a stationary vent system is required.
Connect Vent
1. If connecting to existing vent, make sure the vent is clean.
2. Using a 4" (102 mm) clamp, connect vent to exhaust outlet
in dryer.
NOTE: Do not remove vent collar.
Vent System Length
3. Tighten hose clamp with Phillips screwdriver.
4. Make sure the vent is secured to exhaust hood with
a 4" (102 mm) clamp.
5. Move dryer into nal position. Do not crush or kink vent.
Make sure dryer is level.
12" min.
(305 mm)
Vent collar
Box Hood Louvered Hood Angled Hood
14
The outside end of main vent should have a sweep elbow
directed downward.
If main vent travels vertically through the roof, rather than
through wall, install a 180° sweep elbow on end of vent at least
2 ft. (610 mm) above surface of roof.
The opening in wall or roof shall have a diameter 1⁄2" (13 mm)
larger than vent diameter. Vent should be centered in opening.
Do not install screening over end of vent for best performance.
12" min.
(305 mm)*
A main vent can be used for venting a group of dryers. The
main vent should be sized to remove 5663 l/min. (200 CFM)
of air per dryer. Large-capacity lint screens of proper design
may be used in main vent if checked and cleaned frequently.
The room where the dryers are located should have make-up
air equal to or greater than CFM of all the dryers in the room.
Back-draft Damper Kit, Part No. 3391910, is available from
your distributor and should be installed in the vent of each
dryer to keep exhausted air from returning into dryers and to
keep exhaust in balance within main vent. Unobstructed return
air openings are required.
Each vent should enter the main vent at an angle pointing in
the direction of the airow. Vents entering from the opposite
side should be staggered to reduce the exhausted air from
interfering with the other vents.
The maximum angle of each vent entering the main vent should
be no more than 30°.
Keep air openings free of dry cleaning uid fumes. Fumes
create acids which, when drawn through the dryer heating
units, can damage dryers and items being dried.
A clean-out cover should be located on the main vent for
periodic cleaning of the vent system.
If an Exhaust Hood Cannot be Used Multiple Dryer Venting
DRYER VENTING REQUIREMENTS
24" min.
(610 mm)
* Minimum clearance above
any accumulation of snow,
ice, or debris such as leaves
1. Remove red cap from gas pipe on back of dryer.
2. Connect gas supply to dryer. Use a pipe thread compound
approved for the type of gas supplied. If exible metal
tubing is used, be certain there are no kinks.
If necessary for service, open the toe panel. Use a putty
knife to press on the toe panel locks located at the upper
corners of the toe panel. Pull downward on the toe panel
to open. Toe panel is hinged at the bottom.
3. Open the shut-off valve in the gas supply line and make sure
the dryer has its own gas supply opened.
4. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show
a leak. Correct any leaks found.
Make Gas Connection
GAS SUPPLY CONNECTION
30˚ max.
air ow
Air Flow
15
This dryer is equipped for use with natural gas. It is design-
certied by CSA International for LP (propane and butane)
gases with appropriate conversion. No attempt shall be made
to convert dryer from gas specied on serial/rating plate for use
with a different gas without consulting the serving gas supplier.
Conversion must be done by a qualied service technician.
Gas conversion kit part numbers are listed on gas valve
burner base.
Type of Gas
GAS SUPPLY CONNECTION
Recommended Method
Provide a gas supply line of 1⁄2" (13 mm) rigid (IPS) pipe to
dryer location. Pipe joint compounds that resist action of LP
gas must be used. Do not use TEFLON
®†
tape. With LP gas,
piping or tubing size can be 1⁄2" (13 mm) minimum. Usually, LP
gas suppliers determine size and materials used in the system.
Gas Supply Pressure Testing
A 1/8" (3 mm) NPT minimum plugged tapping, accessible for
gauge testing, must be installed immediately downstream of
the installed shut-off valve to the dryer (as shown above). The
dryer must be disconnected from the gas supply piping system
during any pressure testing of the system at test pressures in
excess of 1/2" psig (352 kg/m
2
).
Alternate Method
The gas supply may also be connected using 38" (10 mm)
approved copper or aluminum tubing. If the total length of
the supply line is more than 20 ft. (6.1 m), larger tubing will
be required.
If using natural gas, do not use copper tubing. Pipe joint
compounds that resist action of type of gas supplied must
be used.
Shut-off valve required
The supply line must be equipped with a manual shut-off
valve installed within 6 ft. (1.8 m) of dryer in accordance
with National Fuel Gas Code, ANSI Z223.1. This valve should
be located in same room as dryer. It should be in a location
that allows ease of opening and closing. Do not block access
to shut-off valve. In Canada, an individual manual shut-off
valve must be installed in accordance with the B149 installation
codes CAN/CGA B149.1 and CAN/CGA B149.2.
Gas Supply Line
Flexible Metal Appliance Connector
It is recommended that a new exible stainless steel gas line,
design-certied by CSA International, be used for connecting
the dryer to the gas supply line. (The gas pipe which extends
through the lower rear of the dryer is provided with 38"
[10 mm] male pipe thread.)
NOTE: Do not kink or damage the exible stainless steel gas
line when moving the dryer.
Rigid Pipe Connection
The rigid pipe connection requires a combination of pipe ttings
to obtain an in-line connection to the dryer.
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
16
INSTALLING COIN SLIDE AND COIN BOX
The console houses the factory-installed accumulator timer
with actuating arm and button.
The factory-installed timer is set to provide 45 minutes (4 pins)
of drying time when activated by the coin slide. Timer cams
for 30-minute (6 pins) and 60-minute (3 pins) drying times are
included in the parts bag.
The coin slide mechanism, control panel lock and key, and coin
box lock and key are not included and are available from the
usual industry sources.
1. Move dryer to desired location
NOTE: Slide dryer onto cardboard or hardboard before moving
to avoid damaging oor covering.
Using two or more people, move dryer to desired installation
location.
Check that each leg is approximately 1" (25 mm) from base.
Open dryer and remove the literature and parts packages.
Wipe drum interior with a damp cloth to remove any dust.
2. Install coin slide and coin box
a. Install coin vaults and locks (not supplied) into meter case
openings.
b. Install control panel lock and key (not supplied).
c. If you wish to change the 45-minute dryer timing cams
to either 30- or 60-minute timing cams, see “Changing
to a 30- or 60-Minute Timing Cam” section. Complete all
of the steps given in that section before going to Step d.
d. Open control panel and rest it on the bottom edge of
the opening. Attach slide extension (with ange pointing
down) to one of the coin-slide mechanisms.
e. Insert the coin-slide mechanism through the opening
to the left of the control panel.
f. Secure the coin slide mechanism from inside the control
panel using the 3⁄16" bolt and washer included with the
slide mechanism.
g. Install the coin box.
h. Repeat Steps d, e, f, and g for the other coin-slide
mechanism.
i. For added security between the upper dryer
and the collar, insert the cotter hair pin through
the connecting bolt.
j. Close the control panel.
17
Power Supply Cord Strain Relief
1. Insert strain relief.
2. Insert power cord into strain relief.
Remove Terminal Block Cover
Strain Relief
ELECTRIC DRYER ELECTRICAL CONNECTIONS
(U.S.A. ONLY) (ÉTATS-UNIS SEULEMENT)
Direct Wire Strain Relief
1. Insert strain relief.
2. Insert conduit into strain relief and tighten clamp.
18
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Power Cord
4-wire receptacle (NEMA Type 14-30R)
3-wire receptacle (NEMA Type 10-30R)
Standard Power Supply Cord Connectors
Flanged Spade Connector Ring Connector
Connecting Ground and Neutral Wires
1. Remove center terminal block screw and the ground wire
by removing the external ground connector screw.
2. Connect ground and neutral wire to center terminal block.
Connection Options
Connecting 4-Wire Connection: Power Supply Cord
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Direct Wire
4-wire direct
3-wire direct
1"
(25 mm)
5"
(127 mm)
Connecting Direct Wire Ground
3. Connect ground wire (green or bare) with external ground
connector screw.
Connecting Remaining Wires
4. Connect remaining wires with outer terminal block screws.
19
2. Connect neutral wire to center terminal block.
3. Connect remaining wires with outer terminal block screws.
Standard Power Cord Connectors
Flanged Spade Connector Ring Connector
Connecting Neutral Wire
1. Loosen or remove center terminal block screw.
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer can be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,
leaving bare ground wire at 5" (127 mm). Cut 1
1
2
" (38 mm)
from 3 remaining wires. Strip insulation back 1" (25 mm).
Shape ends of wires into a hook shape.
Connecting 3-Wire Connection: Power Supply Cord
Connecting 4-Wire Connection: Direct Wire
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Connecting Ground and Neutral Wires
1. Remove center terminal block screw and the ground wire
by removing the external ground connector screw.
20
2. Connect neutral wire to center terminal block.
3. Connect remaining wires to outer terminal block.
Connecting Ground and Neutral Wires (cont.)
2. Connect ground and neutral wire to center terminal block.
Connecting Direct Wire Ground
3. Connect ground wire (green or bare) with external ground
connector screw.
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
Direct wire cable must have 5 ft. (1.52 m) of extra length so
dryer can be moved if needed.
Strip 3
1
2
" (89 mm) of outer covering from end of cable. Strip
insulation back 1" (25 mm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of
wires into a hook shape.
Connecting Neutral Wire
1. Loosen or remove center terminal block screw.
Connecting Remaining Wires
4. Connect remaining wires to outer terminal block.
Connecting 3-Wire Connection: Direct Wire
Connecting 4-Wire Connection: Direct Wire
ELECTRIC DRYER ELECTRICAL CONNECTIONS
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48