Big Blue 402P, 502P, 602P
OM-491 190 355AG
November 2002
Visit our website at
www.MillerWelds.com
Processes
Description
Air Carbon Arc (CAC-A)
Cutting and Gouging
Stick (SMAW) Welding
Engine Driven Welding Generator
TIG (GTAW) Welding
MIG (GMAW) Welding
Flux Cored (FCAW) Welding
Miller Electric manufactures a full line
of welders and welding related equipment.
For information on other quality Miller
products, contact your local Miller distributor to receive the latest full
line catalog orindividual catalog sheets. To locate your nearest
distributor or service agency call 1-800-4-A-Miller, or visit us at
www.MillerWelds.com on the web.
Thank you and congratulations on choosing Miller. Now you can get
the job done and get it done right. We know you don’t have time to do
it any other way.
That’s why when Niels Miller first started building arc welders in 1929,
he made sure his products offered long-lasting value and superior
quality. Like you, his customers couldn’t afford anything less. Miller
products had to be more than the best they could be. They had to be the
best you could buy.
Today, the people that build and sell Miller products continue the
tradition. They’re just as committed to providing equipment and service
that meets the high standards of quality and value established in 1929.
This Owners Manual is designed to help you get the most out of your
Miller products. Please take time to read the Safety precautions. They
will help you protect yourself against potential hazards on the worksite.
We’ve made installation and operation quick
and easy. With Miller you can count on years
of reliable service with proper maintenance.
And if for some reason the unit needs repair,
there’s a Troubleshooting section that will
help you figure out what the problem is. The
parts list will then help you to decide the
exact part you may need to fix the problem.
Warranty and service information for your
particular model are also provided.
Miller is the first welding
equipment manufacturer in
the U.S.A. to be registered to
the ISO 9001:2000 Quality
System Standard.
Working as hard as you do
– every power source from
Miller is backed by the most
hassle-free warranty in the
business.
From Miller to You
Miller offers a Technical
Manual which provides
more detailed service and
parts information for your
unit. To obtain a Technical
Manual, contact your local
distributor. Your distributor
can also supply you with
Welding Process Manuals
such as SMAW, GTAW,
GMAW, and GMAW-P.
The following terms are
used interchangeably
throughout this manual:
Stick = SMAW
TIG = GTAW
MIG = GMAW
CALIFORNIA
Proposition 65
Warning
Diesel engine exhaust and
some of its constituents
are known to the State of
California to cause
cancer, birth defects, and
other reproductive harm.
TABLE OF CONTENTS
SECTION 1 – SAFETY PRECAUTIONS – READ BEFORE USING 1. . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Engine Hazards 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Compressed Air Hazards 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Additional Symbols For Installation, Operation, And Maintenance 3. . . . . . . . . . . . . . . . . . . . .
1-6. Principal Safety Standards 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-7. EMF Information 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT UTILISATION 5. . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à larc 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Dangers existant en relation avec le moteur 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Dangers supplémentaires en relation avec linstallation, le fonctionnement
et la maintenance 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Principales normes de sécurité 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-6. Information sur les champs électromagnétiques 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – DEFINITIONS 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 – SPECIFICATIONS 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Weld, Power, And Engine Specifications 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Dimensions, Weights, And Operating Angles 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-3. Volt-Ampere Curves For CC Models 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-4. Volt-Ampere Curves For CC/CV Models 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-5. Fuel Consumption 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-6. Duty Cycle And Overheating 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-7. AC Generator Power Curve 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-8. Optional Three-Phase Generator Curves 13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 – INSTALLATION 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Installing Welding Generator 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Mounting Welding Generator 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Using Lifting Eye 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Installing Exhaust Pipe 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Activating The Dry Charge Battery (If Applicable) 17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Connecting The Battery 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Engine Prestart Checks 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Connecting To Weld Output Terminals 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Selecting Weld Cable Sizes* 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-10. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models 21. . . . . . . . . . . . .
4-11. Connecting To Remote 14 Receptacle RC14 On CC/CV Models 21. . . . . . . . . . . . . . . . . . . . . .
SECTION 5 – OPERATING WELDING GENERATOR – CC MODELS 22. . . . . . . . . . . . . . . . . . . . . . . . .
5-1. Front Panel Controls For CC Models (See Section 5-2) 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2. Description Of Front Panel Controls For CC Models (See Section 5-1) 23. . . . . . . . . . . . . . . . .
5-3. Remote Amperage Control On CC Models (Optional) 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 – OPERATING WELDING GENERATOR – CC/CV MODELS 26. . . . . . . . . . . . . . . . . . . . . .
6-1. Front Panel Controls For CC/CV Models (See Section 6-2) 26. . . . . . . . . . . . . . . . . . . . . . . . . .
6-2. Description Of Front Panel Controls For CC/CV Models (See Section 6-1) 27. . . . . . . . . . . . . .
6-3. Process/Contactor Switch On CC/CV Models 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-4. Remote Voltage/Amperage Control On CC/CV Models (Optional) 29. . . . . . . . . . . . . . . . . . . . .
SECTION 7 – OPERATING AUXILIARY EQUIPMENT 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-1. 120 Volt And 240 Volt Receptacles 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2. Connecting To Optional Three-Phase Generator (CC/CV Models Only) 31. . . . . . . . . . . . . . . .
7-3. Optional Generator Power Receptacles 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 8 – MAINTENANCE & TROUBLESHOOTING 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-1. Routine Maintenance 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-2. Maintenance Label 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-3. Servicing Air Cleaner 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-4. Inspecting And Cleaning Optional Spark Arrestor Muffler 37. . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-5. Adjusting Engine Speed 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-6. Servicing Fuel And Lubrication Systems 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-7. Overload Protection 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-8. Diagnosing Causes Of Engine Fault Shutdowns 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8-9. Troubleshooting 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 9 – ELECTRICAL DIAGRAMS 46. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 10 – RUN-IN PROCEDURE 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-1. Wetstacking 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-2. Run-In Procedure Using Load Bank 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10-3. Run-In Procedure Using Resistance Grid 52. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 11 – GENERATOR POWER GUIDELINES 53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 12 – PARTS LIST 60. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPTIONS AND ACCESSORIES
WARRANTY
WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)
WARNING
Battery posts, terminals
and related accessories
contain lead and lead
compounds, chemicals
known to the State of
California to cause cancer
and birth defects or other
reproductive harm. Wash
hands after handling.
OM-491 Page 1
SECTION 1 SAFETY PRECAUTIONS READ BEFORE USING
rom _nd_10/02
Warning: Protect yourself and others from injury read and follow these precautions.
1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Marks a special safety message.
Means “Note”; not safety related.
This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.
1-2. Arc Welding Hazards
The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-6. Read and follow all
Safety Standards.
Only qualified persons should install, operate, maintain, and
repair this unit.
During operation, keep everybody, especially children, away.
ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.
Do not touch live electrical parts.
Wear dry, hole-free insulating gloves and body protection.
Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
Use AC output ONLY if required for the welding process.
If AC output is required, use remote output control if present
on unit.
Additional safety precautions are required when any of the follow-
ing electrically hazardous conditions are present: in damp
locations or while wearing wet clothing; on metal structures such
as floors, gratings, or scaffolds; when in cramped positions such
as sitting, kneeling, or lying; or when there is a high risk of unavoid-
able or accidental contact with the workpiece or ground. For these
conditions, use the following equipment in order presented: 1) a
semiautomatic DC constant voltage (wire) welder, 2) a DC manual
(stick) welder, or 3) an AC welder with reduced open-circuit volt-
age. In most situations, use of a DC, constant voltage wire welder
is recommended. And, do not work alone!
Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
Properly install and ground this equipment according to its
Owners Manual and national, state, and local codes.
Always verify the supply ground check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
When making input connections, attach proper grounding conduc-
tor first double-check connections.
Frequently inspect input power cord for damage or bare wiring
replace cord immediately if damaged bare wiring can kill.
Turn off all equipment when not in use.
Do not use worn, damaged, undersized, or poorly spliced cables.
Do not drape cables over your body.
If earth grounding of the workpiece is required, ground it directly
with a separate cable.
Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.
Wear a safety harness if working above floor level.
Keep all panels and covers securely in place.
Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.
Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
Do not connect more than one electrode or work cable to any
single weld output terminal.
SIGNIFICANT DC VOLTAGE exists in inverters after
stopping engine.
Stop engine on inverter and discharge input capacitors according
to instructions in Maintenance Section before touching any parts.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.
FUMES AND GASES can be hazardous.
Keep your head out of the fumes. Do not breathe the fumes.
If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
If ventilation is poor, use an approved air-supplied respirator.
Read the Material Safety Data Sheets (MSDSs) and the
manufacturers instructions for metals, consumables, coatings,
cleaners, and degreasers.
Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watch-
person nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breath-
ing air is safe.
Do not weld in locations near degreasing, cleaning, or spraying op-
erations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.
Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.
OM-491 Page 2
BUILDUP OF GAS can injure or kill.
Shut off shielding gas supply when not in use.
Always ventilate confined spaces or use
approved air-supplied respirator.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from
the weld.
ARC RAYS can burn eyes and skin.
Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes from arc rays and sparks when welding or
watching (see ANSI Z49.1 and Z87.1 listed in Safety Standards).
Wear approved safety glasses with side shields under your
helmet.
Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
Wear protective clothing made from durable, flame-resistant mate-
rial (wool and leather) and foot protection.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
WELDING can cause fire or explosion.
Protect yourself and others from flying sparks and hot metal.
Do not weld where flying sparks can strike flammable material.
Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
Watch for fire, and keep a fire extinguisher nearby.
Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
Do not use welder to thaw frozen pipes.
Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.
Follow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B
for hot work and have a fire watcher and extinguisher nearby.
FLYING METAL can injure eyes.
Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
Wear approved safety glasses with side
shields even under your welding helmet.
HOT PARTS can cause severe burns.
Allow cooling period before maintaining.
Wear protective gloves and clothing when
working on a hot engine.
Do not touch hot engine parts or just-welded
parts bare-handed.
NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
Wear approved ear protection if noise level
is high.
MAGNETIC FIELDS can affect pacemakers.
Pacemaker wearers keep away.
Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
CYLINDERS can explode if damaged.
Protect compressed gas cylinders from excessive heat, mechani-
cal shocks, slag, open flames, sparks, and arcs.
Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
Keep cylinders away from any welding or other electrical circuits.
Never drape a welding torch over a gas cylinder.
Never allow a welding electrode to touch any cylinder.
Never weld on a pressurized cylinder explosion will result.
Use only correct shielding gas cylinders, regulators, hoses, and fit-
tings designed for the specific application; maintain them and
associated parts in good condition.
Turn face away from valve outlet when opening cylinder valve.
Keep protective cap in place over valve except when cylinder is in
use or connected for use.
Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.
1-3. Engine Hazards
BATTERY EXPLOSION can BLIND.
Always wear a face shield, rubber gloves, and
protective clothing when working on a battery.
Stop engine before disconnecting or connect-
ing battery cables or servicing battery.
Do not allow tools to cause sparks when working on a battery.
Do not use welder to charge batteries or jump start vehicles.
Observe correct polarity (+ and ) on batteries.
Disconnect negative () cable first and connect it last.
FUEL can cause fire or explosion.
Stop engine and let it cool off before checking or
adding fuel.
Do not add fuel while smoking or if unit is near
any sparks or open flames.
Do not overfill tank allow room for fuel to expand.
Do not spill fuel. If fuel is spilled, clean up before starting engine.
Dispose of rags in a fireproof container.
Always keep nozzle in contact with tank when fueling.
OM-491 Page 3
MOVING PARTS can cause injury.
Keep away from fans, belts, and rotors.
Keep all doors, panels, covers, and guards
closed and securely in place.
Stop engine before installing or connecting unit.
Have only qualified people remove guards or covers for maint-
enance and troubleshooting as necessary.
To prevent accidental starting during servicing, disconnect
negative () battery cable from battery.
Keep hands, hair, loose clothing, and tools away from moving
parts.
Reinstall panels or guards and close doors when servicing is
finished and before starting engine.
Before working on generator, remove spark plugs or injectors to
keep engine from kicking back or starting.
Block flywheel so that it will not turn while working on generator
components.
STEAM AND HOT COOLANT can burn.
If possible, check coolant level when engine is
cold to avoid scalding.
Always check coolant level at overflow tank, if
present on unit, instead of radiator (unless told
otherwise in maintenance section or engine
manual).
If the engine is warm, checking is needed, and there is no over-
flow tank, follow the next two statements.
Wear safety glasses and gloves and put a rag over radiator cap.
Turn cap slightly and let pressure escape slowly before
completely removing cap.
ENGINE EXHAUST GASES can kill.
Use equipment outside in open, well-ventilated
areas.
If used in a closed area, vent engine exhaust
outside and away from any building air intakes.
BATTERY ACID can BURN SKIN and EYES.
Do not tip battery.
Replace damaged battery.
Flush eyes and skin immediately with water.
ENGINE HEAT can cause fire.
Do not locate unit on, over, or near combustible
surfaces or flammables.
Keep exhaust and exhaust pipes way from
flammables.
EXHAUST SPARKS can cause fire.
Do not let engine exhaust sparks cause fire.
Use approved engine exhaust spark arrestor in
required areas see applicable codes.
1-4. Compressed Air Hazards
BREATHING COMPRESSED AIR can
cause serious injury or death.
Do not use compressed air for breathing.
Use only for cutting, gouging, and tools.
COMPRESSED AIR can cause injury.
Wear approved safety goggles.
Do not direct air stream toward self or others.
TRAPPED AIR PRESSURE AND WHIPPING
HOSES can cause injury.
Release air pressure from tools and system
before servicing, adding or changing attach-
ments, or opening compressor oil drain or oil
fill cap.
HOT METAL from air arc cutting and
gouging can cause fire or explosion.
Do not cut or gouge near flammables.
Watch for fire; keep extinguisher nearby.
HOT PARTS can cause burns and injury.
Do not touch hot compressor or air system
parts.
Let system cool down before touching or
servicing.
READ INSTRUCTIONS.
Read Owners Manual before using or servic-
ing unit.
Stop engine and release air pressure before
servicing.
1-5. Additional Symbols For Installation, Operation, And Maintenance
FALLING UNIT can cause injury.
Use lifting eye to lift unit only, NOT running
gear, gas cylinders, trailer, or any other
accessories.
Use equipment of adequate capacity to lift and
support unit.
If using lift forks to move unit, be sure forks are long enough to
extend beyond opposite side of unit.
OVERHEATING can damage motors.
Turn off or unplug equipment before starting or
stopping engine.
Do not let low voltage and frequency caused by
low engine speed damage electric motors.
Do not connect 50 or 60 Hertz motors to the 100 Hertz receptacle
where applicable.
OM-491 Page 4
FLYING SPARKS can cause injury.
Wear a face shield to protect eyes and face.
Shape tungsten electrode only on grinder with
proper guards in a safe location wearing proper
face, hand, and body protection.
Sparks can cause fires keep flammables away.
OVERUSE can cause OVERHEATING.
Allow cooling period; follow rated duty cycle.
Reduce current or reduce duty cycle before
starting to weld again.
Do not block or filter airflow to unit.
STATIC (ESD) can damage PC boards.
Put on grounded wrist strap BEFORE handling
boards or parts.
Use proper static-proof bags and boxes to
store, move, or ship PC boards.
TILTING OF TRAILER can cause injury.
Use tongue jack or blocks to support weight.
Properly install welding generator onto trailer
according to instructions supplied with trailer.
READ INSTRUCTIONS.
Use only genuine MILLER/Hobart replacement
parts.
Perform engine and air compressor (if applica-
ble) maintenance and service according to this
manual and the engine/air compressor (if appli-
cable) manuals.
H.F. RADIATION can cause interference.
High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician
promptly correct any interference problem resulting from the
installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.
ARC WELDING can cause interference.
Electromagnetic energy can interfere with
sensitive electronic equipment such as micro-
processors, computers, and computer-driven
equipment such as robots.
Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive elec-
tronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.
1-6. Principal Safety Standards
Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1,
from American Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
(phone: 305-443-9353, website: www.aws.org).
Recommended Safe Practices for the Preparation for Welding and Cut-
ting of Containers and Piping, American Welding Society Standard
AWS F4.1, from American Welding Society, 550 N.W. LeJeune Rd, Mi-
ami, FL 33126 (phone: 305-443-9353, website: www.aws.org).
National Electrical Code, NFPA Standard 70, from National Fire Protec-
tion Association, P.O. Box 9101, 1 Battery March Park, Quincy, MA
02269-9101 (phone: 617-770-3000, website: www.nfpa.org and www.
sparky.org).
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1735 Jefferson Davis Highway,
Suite 1004, Arlington, VA 22202-4102 (phone: 703-412-0900, website:
www.cganet.com).
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale Bou-
levard, Rexdale, Ontario, Canada M9W 1R3 (phone: 800-463-6727 or
in Toronto 416-747-4044, website: www.csa-international.org).
Practice For Occupational And Educational Eye And Face Protection,
ANSI Standard Z87.1, from American National Standards Institute, 11
West 42nd Street, New York, NY 100368002 (phone: 212-642-4900,
website: www.ansi.org).
Standard for Fire Prevention During Welding, Cutting, and Other Hot
Work, NFPA Standard 51B, from National Fire Protection Association,
P.O. Box 9101, 1 Battery March Park, Quincy, MA 02269-9101 (phone:
617-770-3000, website: www.nfpa.org and www. sparky.org).
OSHA, Occupational Safety and Health Standards for General Indus-
try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,
and Part 1926, Subpart J, from U.S. Government Printing Office, Super-
intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250 (there
are 10 Regional Officesphone for Region 5, Chicago, is
312-353-2220, website: www.osha.gov).
1-7. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electro-
magnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: The body of evidence, in the
committees judgment, has not demonstrated that exposure to power-
frequency electric and magnetic fields is a human-health hazard.
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:
1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from
operator as practical.
5. Connect work clamp to workpiece as close to the weld as
possible.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.
OM-491 Page 5
SECTION 1 CONSIGNES DE SÉCURITÉ LIRE AVANT
UTILISATION
rom _nd_fre 4/02
1-1. Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Identifie un message de sécurité particulier.
Signifie NOTA ; nest pas relatif à la sécurité.
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.
1-2. Dangers relatifs au soudage à larc
Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les ris-
ques de danger. Lorsque vous voyez un symbole, soyez
vigilant et suivez les directives mentionnées afin d’éviter tout
danger. Les consignes de sécurité présentées ci-après ne font
que résumer linformation contenue dans les normes de sécu-
rité énumérées à la section 1-5. Veuillez lire et respecter toutes
ces normes de sécurité.
Linstallation, lutilisation, lentretien et les réparations ne
doivent être confiés qu’à des personnes qualifiées.
Au cours de lutilisation, tenir toute personne à l’écart et plus
particulièrement les enfants.
UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension dès
que lappareil est sur ON. Le circuit dentrée et les circuits
internes de lappareil sont également sous tension à ce
moment-là. En soudage semi-automatique ou automatique, le fil, le dévidoir, le
logement des galets dentraînement et les pièces métalliques en contact avec
le fil de soudage sont sous tension. Des matériels mal installés ou mal mis à la
terre présentent un danger.
Ne jamais toucher les pièces électriques sous tension.
Porter des gants et des vêtements de protection secs ne comportant pas
de trous.
Sisoler de la pièce et de la terre au moyen de tapis ou dautres moyens iso-
lants suffisamment grands pour empêcher le contact physique éventuel
avec la pièce ou la terre.
Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir dune source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si lutilisation dune source électrique àcourant électrique savère néces-
saire, se servir de la fonction de télécommande si lappareil en est équipé.
Couper lalimentation ou arrêter le moteur avant de procéder à linstallation,
à la réparation ou à lentretien de lappareil. Déverrouiller lalimentation
selon la norme OSHA 29 CFR 1910.147 (voir normes de sécurité).
Installer et mettre à la terre correctement cet appareil conformément à son
manuel dutilisation et aux codes nationaux, provinciaux et municipaux.
Toujours vérifier la terre du cordon dalimentation Vérifier et sassurer que
le fil de terre du cordon dalimentation est bien raccordé à la borne de terre
du sectionneur ou que la fiche du cordon est raccordée à une prise
correctement mise à la terre.
En effectuant les raccordements dentrée fixer dabord le conducteur de
mise à la terre approprié et contre-vérifier les connexions.
Vérifier fréquemment le cordon dalimentation pour voir sil nest pas en-
dommagé ou dénudé remplacer le cordon immédiatement sil est
endommagé un câble dénudé peut provoquer une électrocution.
Mettre lappareil hors tension quand on ne lutilise pas.
Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou
mal épissés.
Ne pas enrouler les câbles autour du corps.
Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct ne pas utiliser le connecteur de pièce ou le câble de retour.
Ne pas toucher l’électrode quand on est en contact avec la pièce, la terre ou
une électrode provenant dune autre machine.
Nutiliser quun matériel en bon état. Réparer ou remplacer sur-le-champ
les pièces endommagées. Entretenir lappareil conformément à ce
manuel.
Porter un harnais de sécurité quand on travaille en hauteur.
Maintenir solidement en place tous les panneaux et capots.
Fixer le câble de retour de façon à obtenir un bon contact métal-métal avec
la pièce à souder ou la table de travail, le plus près possible de la soudure.
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.
Une tension DC importante subsiste à lintérieur
des onduleurs après avoir coupé lalimentation.
Couper lalimentation du poste et décharger les condensateurs dentrée
comme indiqué dans la Section Maintenance avant de toucher des compo-
sants.
Le rayonnement de larc du procédé de soudage génère
des rayons visibles et invisibles intenses (ultraviolets et
infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la
peau. Des étincelles sont projetées pendant le soudage.
LES RAYONS DE LARC peuvent pro-
voquer des brûlures dans les yeux et
sur la peau.
Porter un casque de soudage muni dun écran de filtre approprié pour pro-
téger votre visage et vos yeux pendant le soudage ou pour regarder (voir
ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.
Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair et de
l’éblouissement; demander aux autres personnes de ne pas regarder larc.
Porter des vêtements de protection constitué dans une matière durable, ré-
sistant au feu (laine ou cuir) et une protection des pieds.
LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur inhalation
peut être dangereux pour votre santé.
Eloigner votre tête des fumées. Ne pas respirer les fumées.
À linterieur, ventiler la zone et/ou utiliser un échappement au niveau de
larc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimentation dair
homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les instruc-
tions du fabricant concernant les métaux, les consommables, les
revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement sil est bien ventilé ou en por-
tant un respirateur à alimentation dair. Demander toujours à un surveillant
dûment formé de se tenir à proximité. Des fumées et des gaz de soudage
peuvent déplacer lair et abaisser le niveau doxygène provoquant des
blessures ou des accidents mortels. Sassurer que lair de respiration ne
présente aucun danger.
Ne pas souder dans des endroits situés à proximité dopérations de dé-
graissage, de nettoyage ou de pulvérisation. La chaleur et les rayons de
larc peuvent réagir en présence de vapeurs et former des gaz hautement
toxiques et irritants.
Ne pas souder des métaux munis dun revêtement, tels que lacier galvani-
sé, plaqué en plomb ou au cadmium à moins que le revêtement nait été
enlevé dans la zone de soudure, que lendroit soit bien ventilé, et si néces-
saire, en portant un respirateur à alimentation dair. Les revêtements et
tous les métaux renfermant ces éléments peuvent dégager des fumées
toxiques en cas de soudage.
OM-491 Page 6
Le soudage effectué sur des conteneurs fermés tels que
des réservoirs, tambours ou des conduites peut provoquer
leur éclatement. Des étincelles peuvent être projetées de
larc de soudure. La projection d’étincelles, des pièces chaudes et des
équipements chauds peut provoquer des incendies et des brûlures. Le contact
accidentel de l’électrode avec des objets métalliques peut provoquer des
étincelles, une explosion, un surchauffement ou un incendie. Avant de
commencer le soudage, vérifier et sassurer que lendroit ne présente pas de
danger.
LE SOUDAGE peut provoquer un in-
cendie ou une explosion.
Se protéger et dautres personnes de la projection d’étincelles et de métal
chaud.
Ne pas souder dans un endroit là où des étincelles peuvent tomber sur des
substances inflammables.
Déplacer toutes les substances inflammables à une distance de 10,7 m de
larc de soudage. En cas dimpossibilité les recouvrir soigneusement avec
des protections homologués.
Des étincelles et des matériaux chauds du soudage peuvent facilement
passer dans dautres zones en traversant de petites fissures et des
ouvertures.
Surveiller tout déclenchement dincendie et tenir un extincteur à proximité.
Le soudage effectué sur un plafond, plancher, paroi ou séparation peut dé-
clencher un incendie de lautre côté.
Ne pas effectuer le soudage sur des conteneurs fermés tels que des réser-
voirs, tambours, ou conduites, à moins quils naient été préparés
correctement conformément à AWS F4.1 (voir les normes de sécurité).
Brancher le câble sur la pièce le plus près possible de la zone de soudage
pour éviter le transport du courant sur une longue distance par des che-
mins inconnus éventuels en provoquant des risques d’électrocution et
dincendie.
Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
En cas de non utilisation, enlever la baguette d’électrode du porte-électro-
de ou couper le fil à la pointe de contact.
Porter des vêtements de protection dépourvus dhuile tels que des gants
en cuir, une chemise en matériau lourd, des pantalons sans revers, des
chaussures hautes et un couvre chef.
Avant de souder, retirer toute substance combustible de vos poches telles
quun allumeur au butane ou des allumettes.
DES PARTICULES VOLANTES
peuvent blesser les yeux.
Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques vo-
lantes. Pendant la période de refroidissement des soudures, elles ris-
quent de projeter du laitier.
Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.
LES ACCUMULATIONS DE GAZ ris-
quent de provoquer des blessures ou
même la mort.
Fermer lalimentation du gaz protecteur en cas de
non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir dun respi-
rateur dadduction dair homologué.
DES PIÈCES CHAUDES peuvent
provoquer des brûlures graves.
Prévoir une période de refroidissement avant deffec-
tuer des travaux dentretien.
Porter des gants et des vêtements de protection pour
travailler sur un moteur chaud.
Ne pas toucher à mains nues les parties chaudes du moteur ni les pièces
récemment soudées.
LE BRUIT peut affecter louïe.
Le bruit des processus et des équipements peut affecter
louïe.
Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.
LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs dun stimulateur cardiaque doivent
dabord consulter leur médecin avant de sapprocher
des opérations de soudage à larc, de gougeage ou
de soudage par points.
Si des BOUTEILLES sont endomma-
gées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz sous
haute pression. Si une bouteille est endommagée, elle peut
exploser. Du fait que les bouteilles de gaz font normale-
ment partie du procédé de soudage, les manipuler avec
précaution.
Protéger les bouteilles de gaz comprimé dune chaleur excessive, des
chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des
arcs.
Placer les bouteilles debout en les fixant dans un support stationnaire ou
dans un porte-bouteilles pour les empêcher de tomber ou de se renverser.
Tenir les bouteilles éloignées des circuits de soudage ou autres circuits
électriques.
Ne jamais placer une torche de soudage sur une bouteille à gaz.
Une électrode de soudage ne doit jamais entrer en contact avec une bou-
teille.
Ne jamais souder une bouteille pressurisée risque dexplosion.
Utiliser seulement des bouteilles de gaz protecteur, régulateurs, tuyaux et
raccords convenables pour cette application spécifique; les maintenir ainsi
que les éléments associés en bon état.
Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la bouteille.
Maintenir le chapeau de protection sur la soupape, sauf en cas dutilisation
ou de branchement de la bouteille.
Lire et suivre les instructions concernant les bouteilles de gaz comprimé,
les équipements associés et les publication P-1 CGA énumérées dans les
normes de sécurité.
1-3. Dangers existant en relation avec le moteur
LE CARBURANT MOTEUR peut pro-
voquer un incendie ou une explosion.
Arrêter le moteur avant de vérifier le niveau de carbu-
rant ou de faire le plein.
Ne pas faire le plein en fumant ou proche dune sour-
ce d’étincelles ou dune flamme nue.
Ne pas faire le plein de carburant à ras bord; prévoir de lespace pour son
expansion.
Faire attention de ne pas renverser de carburant. Nettoyer tout carbu-
rant renversé avant de faire démarrer le moteur.
Jeter les chiffons dans un récipient ignifuge.
LA VAPEUR ET LE LIQUIDE DE
REFROIDISSEMENT CHAUD peuvent
provoquer des brûlures.
Il est préférable de vérifier le liquide de
refroidissement une fois le moteur refroidi pour éviter
de se brûler.
Toujours vérifier le niveau de liquide de refroidissement dans le vase
dexpansion (si présent), et non dans le radiateur (sauf si précisé autre-
ment dans la section maintenance du manuel du moteur).
Si le moteur est chaud et que le liquide doit être vérifié, opérer comme
suivant :
Mettre des lunettes de sécurité et des gants, placer un torchon sur le
bouchon du radiateur.
Dévisser le bouchon légèrement et laisser la vapeur s’échapper avant
denlever le bouchon.
OM-491 Page 7
DES ORGANES MOBILES peuvent
provoquer des blessures.
Ne pas approcher les mains des ventilateurs, cour-
roies et autres pièces en mouvement.
Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.
Arrêter le moteur avant dinstaller ou brancher lappareil.
Demander seulement à un personnel qualifié denlever les dispositifs de
sécurité ou les recouvrements pour effectuer, sil y a lieu, des travaux
dentretien et de dépannage.
Pour empêcher tout démarrage accidentel pendant les travaux dentre-
tien, débrancher le câble négatif () de batterie de la borne.
Ne pas approcher les mains, cheveux, vêtements lâches et outils des or-
ganes mobiles.
Remettre en place les panneaux ou les dipositifs de protection et fermer
les portes à la fin des travaux dentretien et avant de faire démarrer le
moteur.
Avant dintervenir, déposer les bougies ou injecteurs pour éviter la mise
en route accidentelle du moteur.
Bloquer le volant moteur pour éviter sa rotation lors dune intervention
sur le générateur.
LEXPLOSION DE LA BATTERIE peut
RENDRE AVEUGLE.
Toujours porter une protection faciale, des gants en
caoutchouc et vêtements de protection lors dune in-
tervention sur la batterie.
Arrêter le moteur avant de débrancher ou de brancher les câbles de
batterie.
Eviter de provoquer des étincelles avec les outils en travaillant sur la
batterie.
Ne pas utiliser le poste de soudage pour charger les batteries ou des vé-
hicules de démarrage rapide.
Observer la polarité correcte (+ et ) sur les batteries.
Débrancher le câble négatif () en premier lieu. Le rebrancher en dernier
lieu.
LACIDE DE LA BATTERIE peut pro-
voquer des brûlures dans les YEUX et
sur la PEAU.
Ne pas renverser la batterie.
Remplacer une batterie endommagée.
Rincer immédiatement les yeux et la peau à leau.
LES GAZ D’ÈCHAPPEMENT DU
MOTEUR peuvent provoquer des
accidents mortels.
Utiliser l’équipement à lextérieur dans des zones ou-
vertes et bien ventilées.
En cas dutilisation dans un endroit fermé évacuer les gaz d’échappe-
ment du moteur vers lextérieur à distance des entrées dair dans les bâti-
ments.
LA CHALEUR DU MOTEUR peut pro-
voquer un incendie.
Ne pas placer lappareil sur, au-dessus ou à proximité
de surfaces inflammables.
Tenir à distance les produits inflammables de
l’échappement.
LES ÉTINCELLES À L’ÉCHAPPEMENT
peuvent provoquer un incendie.
Empêcher les étincelles d’échappement du moteur
de provoquer un incendie.
Utiliser uniquement un pare-étincelles approuvé
voir codes en vigueur.
1-4. Dangers supplémentaires en relation avec linstallation, le fonctionnement
et la maintenance
LA CHUTE DE LAPPAREIL peut
blesser.
Utiliser lanneau de levage uniquement pour soulever
lappareil lui-même ; sans chariot, de bouteilles de
gaz, remorque, ou autres accessoires.
Utiliser un équipement de levage de capacité suffi-
sante pour lever lappareil.
En utilisant des fourches de levage pour déplacer lunité, sassurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de lappareil.
LES ÉTINCELLES VOLANTES ris-
quent de provoquer des blessures.
Porter un écran facial pour protéger le visage et les
yeux.
Affuterr l’électrode au tungstène uniquement à la meuleuse dotée de pro-
tecteurs. Cette manoeuvre est à exécuter dans un endroit sûr lorsque
lon porte l’équipement homologué de protection du visage, des mains et
du corps.
Les étincelles risquent de causer un incendie éloigner toute substance
inflammable.
LE SURCHAUFFEMENT peut endom-
mager le moteur électrique.
Arrêter ou déconnecter l’équipement avant de dé-
marrer ou darrêter le moteur.
Ne pas laisser tourner le moteur trop lentement sous
risque dendommager le moteur électrique à cause
dune tension et dune fréquence trop faibles.
Ne pas brancher de moteur de 50 ou de 60 Hz à la prise de 100 Hz, sil y a
lieu.
LEMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.
Laisser l’équipement refroidir ; respecter le facteur de
marche nominal.
Réduire le courant ou le facteur de marche avant de
poursuivre le soudage.
Ne pas obstruer les passages dair du poste.
LES CHARGES ÉLECTROSTATI-
QUES peuvent endommager les
circuits imprimés.
Établir la connexion avec la barrette de terre avant de
manipuler des cartes ou des pièces.
Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.
UNE REMORQUE QUI BASCULE peut
entraîner des blessures.
Utiliser les supports de la remorque ou des blocs
pour soutenir le poids.
Installer convenablement le poste sur la remorque
comme indiqué dans le manuel sy rapportant.
LIRE LES INSTRUCTIONS.
Utiliser seulement les pièces de rechange dorigine.
Effecteur la maintenance et la mise en service
daprès le manuel et celui du moteur.
OM-491 Page 8
LE RAYONNEMENT HAUTE FRÉ-
QUENCE (H.F.) risque de provoquer
des interférences.
Le rayonnement haute fréquence (H.F.) peut
provoquer des interférences avec les équipements
de radionavigation et de communication, les
services de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées avec des
équipements électroniques de faire fonctionner linstallation.
Lutilisateur est tenu de faire corriger rapidement par un électricien quali-
fié les interférences résultant de linstallation.
Si le FCC signale des interférences, arrêter immédiatement lappareil.
Effectuer régulièrement le contrôle et lentretien de linstallation.
Maintenir soigneusement fermés les portes et les panneaux des sources
de haute fréquence, maintenir les éclateurs à une distance correcte et
utiliser une terre et et un blindage pour réduire les interférences
éventuelles.
LE SOUDAGE À LARC risque de
provoquer des interférences.
L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement com-
mandé par ordinateur tel que les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible
électromagnétiquement.
Pour réduire la possibilité dinterférence, maintenir les câbles de souda-
ge aussi courts que possible, les grouper, et les poser aussi bas que pos-
sible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement élec-
tronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre conformé-
ment à ce mode demploi.
En cas dinterférences après avoir pris les mesures précédentes, il in-
combe à lutilisateur de prendre des mesures supplémentaires telles que
le déplacement du poste, lutilisation de câbles blindés, lutilisation de fil-
tres de ligne ou la pose de protecteurs dans la zone de travail.
1-5. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de lAmerican Weld-
ing Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de lAmerican Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de lAssociation canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protec-
tion, norme ANSI Z87.1, de lAmerican National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.
1-6. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour lorganisme,
des champs magnétiques basse fréquence
Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: Laccumulation de preuves, suivant le
jugement du comité, na pas démontré que lexposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.
Afin de réduire les champs électromagnétiques dans lenvironnement
de travail, respecter les consignes suivantes :
1 Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
2 Mettre tous les câbles du côté opposé de lopérateur.
3 Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
4 Garder le poste de soudage et les câbles le plus loin possible de
vous.
5 Relier la pince de masse le plus près possible de la zone de
soudure.
Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes cidessus.
OM-491 Page 9
SECTION 2 DEFINITIONS
2-1. Symbols And Definitions
Stop Engine
Fast (Run, Weld/
Power)
Slow (Idle) Start Engine
Starting Aid Battery (Engine)
Engine Oil
Pressure
Engine Oil
Check Injectors/
Pump
Check Valve
Clearance
Fuel
Protective Earth
(Ground)
Positive Negative
Certified/Trained
Mechanic
Welding Arc
A
Amperes
V
Volts Panel/Local Remote
Engine
Air Temperature Or
Engine
Temperature
Output
Alternating
Current
Stick (SMAW)
Welding
Constant Current
(CC)
MIG (GMAW)
Welding
TIG (GTAW)
Time
h
Hours
s
Seconds
1
Single Phase
3
Three Phase
Read Operators
Manual
Circuit Breaker
Do Not Switch
While Welding
Electrode
Connection
Work Connection Contactor On
SECTION 3 SPECIFICATIONS
A CC/DC model is shown in this manual.
NOTE
3-1. Weld, Power, And Engine Specifications
Welding
Mode
Weld Output
Range
Rated Welding
Output
Maximum
Open-
Circuit
Voltage
Generator Power
Rating
Engine
Fuel
Capacity
CC/DC
55 600 A
(CC Models)
20 600 A
(CC/CV Models)
400 A, 40 Volts DC,
100% Duty Cycle
500 A, 40 volts DC,
95
Standard
Single-Phase,
4 kVA/kW, 34/17 A,
120/240 V AC,
50/60 Hz
Three-Phase Generator
Perkins
25 gal
CV/DC
(CC/CV
Models
Only)
14 40 V
500 A, 40 volts DC,
60% Duty Cycle
600 A, 30 Volts DC,
40% Duty Cycle
56
Three-Phase Generator
Option*
Single-Phase/Three-Phase,
12/20 kVA/kW, 50/48A,
120/240 VAC, 60 Hz
*In Addition To Standard
4 kVA/kW Generator Power
Perkins 3.1524
Water-Cooled,
Three-Cylinder,
45 HP Diesel Engine
25 gal
(95 L)
OM-491 Page 10
3-2. Dimensions, Weights, And Operating Angles
Dimensions
Height
50 in (1270 mm)
(to top of muffler)
G
Width
28-1/2 in (724 mm)
(mtg. brackets turned in)
30-3/4 in (781 mm)
(mtg. brackets turned out)
G
Do not exceed tilt angles or engine could
be damaged or unit could tip.
Do not move or operate unit where it could
Depth 65-1/8 in (1654 mm)
Do not move or operate unit where it could
tip.
A 65-1/8 in (1654 mm)
B* 56 in (1422 mm)
C* 46-1/2 in (1181)
A
D* 9-5/8 in (244 mm)
B
C
E 27-1/2 in (699 mm)
F 1 in (25 mm)
G 29-1/2 in (743 mm)
H
°
H
9/16 in (14 mm) Dia.
4 Holes
Front Panel End
D
°
30
°
30°
* With mounting brackets in center
position. Dimensions vary with
location of mounting brackets.
Front Panel End
F
20
°
20°
30
Weight
E
w/ Perkins
3.1524
No fuel: 1670 lb (758 kg)
w/fuel: 1860 lb (844 kg)
802 161-A
3-3. Volt-Ampere Curves For CC Models
203 412
The volt-ampere curve shows the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900
DC AMPERES
DC VOLTS
Ranges
300Max
185425
125320
85190
5590
OM-491 Page 11
3-4. Volt-Ampere Curves For CC/CV Models
203 414 / 203 415 / 203 413
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
A. Stick Mode
B. MIG Mode
C. TIG Mode
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900
DC AMPERES
DC VOLTS
Ranges
300Max
185425
125320
85190
5590
0
20
40
60
80
100
0 100 200 300 400 500 600 700 800 900 1000
DC AMPERES
DC VOLTS
MAX
MIN
0
20
40
60
80
100
0 50 100 150 200 250 300 350 400 450 500
DC AMPERES
DC VOLTS
Ranges
60310
40200
30130
2070
OM-491 Page 12
3-5. Fuel Consumption
The curve shows typical fuel use
under weld or power loads.
193 093
0 50 100 150 200 250 300 350 400 450 500
DC WELD AMPERES AT 100% DUTY CYCLE
1800 RPM
0
IDLE
Continuous Welding
3-6. Duty Cycle And Overheating
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
Exceeding duty cycle can
damage unit and void
warranty.
100% Duty Cycle At 400 Amperes
089 697-D
OM-491 Page 13
3-7. AC Generator Power Curve
193 018
The ac power curve shows the gen-
erator power in amperes available
at the 120 and 240 volt receptacles.
0
50
100
150
200
250
300
0 5 10 15 20 25 30
AC AMPERES IN 240V MODE
AC VOLTS
0
25
50
75
100
150
125
0102030405060
AC AMPERES IN 120V MODE
3-8. Optional Three-Phase Generator Curves
197 472 / 197 473
The ac power curves show the gen-
erator power available in amperes
at the single-phase 120/240 volt re-
ceptacle or three-phase 240 volt
terminals.
A. 12 kVA/kW Single-Phase AC Output (No Weld Load)
B. 20 kVA/kW Three-Phase AC Output (No Weld Load)
180
190
200
210
220
230
240
250
260
270
280
0
20 40 60 80 100
AC AMPERES
AC VOLTS
180
200
220
240
260
280
0 10203040506070
AC VOLTS
AC AMPERES
90
95
100
105
110
115
120
125
130
135
140
OM-491 Page 14
SECTION 4 INSTALLATION
install3 11/02 Ref. 800 652 / Ref. 800 477-A / 803 274
Always securely fasten weld-
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
If unit does not have GFCI re-
ceptacles, use GFCI-protected
extension cord.
See Section 4-2 for mounting in-
formation.
Grounding:
1 Equipment Grounding Terminal
(On Front Panel)
2 Grounding Cable (Not Supplied)
3 Metal Vehicle Frame
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger insu-
lated copper wire.
Electrically bond generator frame to
vehicle frame by metal-to-metal contact.
GND/PE
1
2
3
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
-1. Installing Welding Generator
OR OR
Grounding
Bed liners, shipping skids, an some running
gear insulate the welding generator from the ve-
hicle frame. Always connect a ground wire from
the generator equipment grounding terminal to
bare metal on the vehicle frame as shown.
OM-491 Page 15
4-2. Mounting Welding Generator
Tools Needed:
9/16 in
2
2
3
4
Welding Unit In Place
Bolting Unit In Place
Do not weld on base. Weld-
ing on base can cause fuel
tank fire or explosion. Weld
only on the four mounting
brackets or bolt unit down.
Do not mount unit by sup-
porting the base only at the
four mounting brackets.
Use cross-supports to ade-
quately support unit and pre-
vent damage to base.
Mounting Surface:
1 Cross-Supports
2 Mounting Brackets (Supplied)
Mount unit on flat surface or use
cross-supports to support base.
Secure unit with mounting brack-
ets.
3 1/2 in Bolt And Washer
(Minimum Not Supplied)
4 3/8-16 x 1 in Screws
(Supplied)
To Bolt Unit In Place:
Remove hardware securing the
four mounting brackets to the base.
Reverse brackets and reattach to
base with original hardware.
Mount unit to truck or trailer with 1/2
in (12 mm) or larger hardware (not
supplied).
To Weld Unit In Place:
Weld unit to truck or trailer only at
the four mounting brackets.
1
Inadequate support.
2
Supporting The Unit
Using Mounting Brackets
install3 5/02 803 274 / 190 250-A / 803 231
Do not use flexible mounts.
1
OR
OM-491 Page 16
4-3. Using Lifting Eye
Ref. 802 169-F
1 Lifting Eye
2 Nut
3 Carriage Bolt
Raise lifting eye until it snaps in
place. Lower lifting eye when not
needed.
To lock the lifting eye in the upright
position, insert a 3/8-16 x 1-1/2 in
carriage bolt through slot in bracket
and secure with nut (bolt and nut not
supplied).
Tools Needed:
2
1
3
4-4. Installing Exhaust Pipe
1/2 in
Tools Needed:
Ref. 802 169-E / Ref. 202 705
Stop engine and let cool.
Point exhaust pipe in desired di-
rection but always away from front
panel and direction of travel.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80

Miller Big Blue 502P Le manuel du propriétaire

Catégorie
Système de soudage
Taper
Le manuel du propriétaire

dans d''autres langues