INSTALLATION INSTRUCTION
Hiline
WS-W2308
HARDWARE
A1 B1 C1
Technology Upgraded
No Driver Required
Driver
(Please direct wire with 120V AC)
Wire Connector
Qty: 3
Junction Box Screw
Qty: 2 + 1 Extra
Mounting Screw
Qty: 2 + 1 Extra
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel quil est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF (APAGADO).
- Coloque el interruptor de la pared en la posición OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. AUGUST, 2015
INSTALLATION INSTRUCTION
Hiline
WS-W2308
C1
C1 G1 F1
A1
E1
B1
D1
FIG.1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
Junction Box
Caulking
Fig.3 Sealing
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
3. Remove mounting screws (C1)
4. Position the xtures backplate on the wall and mark the location for the two drywall anchors (J1). Pre-drill holes and insert the drywall
anchors into the wall.
5. Connect the Fixture wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
Fixture and junction box ground wires should be connected to mounting plate using green screw provided.
Tuck wires carefully inside the junction box.
6. Secure mounting backplate (D1) to the junction box (F1) using junction box screws (B1). The side of the mounting
backplate marked “GND” must face out.
7. Place the xture over the mounting backplate (D1) and secure with screws (C1) and gasket (G1).
COMPLETING THE INSTALLATION (Fig. 3)
8. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline
the outside of xture back plate where it meets the wall. Leave a space at bottom to allow moisture to escape
Fixture Screw
Fixture Screw
Gasket
Wire Connector
Green Screw
Junction Box Screw
Mounting Backplate
Junction Box
Back Plate Dimensions
7 3/4”
4”
1 3/4”
1 3/8”
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. AUGUST, 2015 1
INSTALLATION INSTRUCTION
Hiline - Outdoor
WS-W2312, WS-W2316
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel quil est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF (APAGADO).
- Coloque el interruptor de la pared en la posición OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
A1 B1 C1 D1 E1 F1
Wire
Connector
Qty: 3pcs
Wood Screw
Qty: 2pcs
Plastic Anchor
Qty: 2pcs
Junction Box Screw
Qty: 2pcs + 1 extra
Mounting Screw
Qty: 1 extra
Gasket
Qty: 1 extra
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. AUGUST, 2015 2
Fig.1
PREPARATION
- Shut o the power at the circuit breaker and remove existing xture, including the mounting hardware.
- Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (FIG. 1)
1. Remove the top and bottom mounting screws (E1) from the xture.
2. Position the xtures back plate on the wall and mark the location for the two plastic anchors (C1). Pre-drill holes and insert the plastic
anchors into the wall.
CONNECTING THE WIRES (FIG. 2)
3. Connect the supply wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured. If your outlet box has a green or bare
copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xtures ground wire directly to the mounting plate
using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (FIG. 1)
4. Secure mounting back plate to the junction box using junction box screws (D1). Align with the pre-drill holes where plastic anchor installed
and fasten the mounting plate to the wall using the wood screw (B1). The side of the mounting back plate marked “GND” must face out.
5. Place the xture over the mounting back plate and secure with mounting screws (E1) and gasket (F1).
COMPLETING THE INSTALLATION (FIG. 3)
6. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of xture back plate where it meets the wall. Leave a space at bottom to allow moisture to escape.
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2
Junction Box
Caulking
Fig.3 Sealing
A1
D1
C1
B1
E1
F1
C1
B1
E1
F1
Wire Connector
Ground Wire
Ground Wire Screw
Junction Box Screw
Plastic Anchor
Mounting Back Plate
Wood Screw
Gasket
Mounting
Screw
Junction Box
Plastic Anchor
Wood Screw
Mounting
Screw
Gasket
INSTALLATION INSTRUCTION
Hiline - Outdoor
WS-W2312, WS-W2316
Back Plate Dimensions
1 3/4” 1 3/4”
11 3/4”
15 3/4”
WS-W2312 WS-W2316
1 3/8”
1 1/2”
4” 5 3/4”
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Modern Forms WS-W2308 Hiline Mode d'emploi

Taper
Mode d'emploi