Lumination® LED Luminaires
LUR2 Troubleshooting Checklist & Replacement Parts
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING / AVERTISSEMENT
RISK OF ELECTRIC SHOCK
Turn o power before inspection, installation or removal
• Properly ground electrical enclosure if ground is manipulated
RISK OF FIRE
• F
ollow all NEC and local codes
• LUR LED maintenance requires knowledge of luminaire
electrical systems. If not qualied do not attempt
troubleshooting or repair. Contact a qualied electrician.
Prepare Electrical Wiring
Electrical Requirements
• The LED luminaire must be connected to the mains
supply according to its ratings on the product label.
• Class 1 wiring should be in accordance with NEC.
Grounding Instructions
• The grounding and bonding of the overall system
shall be done in accordance to local electric code
of the country where the luminaire is installed.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation avant d’inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d’alimentation
électrique est manipulée
RISQUES D’INCENDIE
• Respectez tous les codes NEC et codes locaux
• L’entretien du LUR LED nécessite une connaissance du luminaire
systèmes électriques. Si vous n’êtes pas qualié, n’essayez pas
dépannage ou réparation. Contactez un électricien qualié.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
CAN ICES-005(A)/NMB-005(A)
NOTE: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
NOTICE: Current disclaims any liability of injury or property damage
resulting from the use of this troubleshooting guide.
Installation Guide
IND558
A-1024745
Click here for install instructions. Scan code for install video.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 2 of 4
(Rev 05/17/23)
IND558-Lumination-LUR-Series-Gen-2-Linear-Retrofit-Kit-Troubleshooting-Installation-Guide_R01
LUR2 System
Single 4-foot light engine is out
Verify proper orientation of the master and satellite light engines. The labels should point to each other.
As shown below. Please ensure that 2 satellites are not connected back to back, as the latter one will not be lit
.
• If it’s still not lighting up, replace the entire 8-foot section as shown below.
1
The LUR Gen 2 retrot kit consists of an 8-foot conguration. The kit contains two 4ft. light engines: the master and the
satellite. The master light engine has an integral driver that powers itself and one satellite light engine. The LED light
engines are connected by bridge connectors. Within the text, “section(s)” will be brought up, a section compromises of a
light engine, bridge connection and suspension bracket.
Installation
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 3 of 4
(Rev 05/17/23)
IND558-Lumination-LUR-Series-Gen-2-Linear-Retrofit-Kit-Troubleshooting-Installation-Guide_R01
Installation
Single 8-foot section is out
• Ensure that the master/satellite conguration is maintained. If there are 3 consecutive satellites in the row,
that will result in an 8-foot section out.
2
• A single 8-foot master/satellite outage is usually caused by a failed driver in the master light engine.
The driver is not replaceable.
• If not located at the end of the row, replace entire 8-foot section as shown below.
• If the 8-foot section is at the end of the row, then replace the 4-foot section prior to it as well as shown below.
Multiple continuous light engines are out consecutively (more than 2 x 4-foot sections)
• Continuous rows are powered by an internal wiring harness. Check the bridge connector where the outage begins.
- If the 1st out xture is a satellite, check the connection between the prior master and that satellite
(replace veried sections as well).
3
- If the 1st out xture is a master, check the connection prior to the master and satellite
(replace veried sections as well).
• If a faulty connection is found in the bridge, replace as indicated above.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Page 4 of 4
(Rev 05/17/23)
IND558-Lumination-LUR-Series-Gen-2-Linear-Retrofit-Kit-Troubleshooting-Installation-Guide_R01
Important Notes:
• Please mark the removed xtures in pairs so when
received they can be analyzed together.
• If a bridge connection will not easily back out while
performing checks, then remove complete 8-foot with
the bridge in question in the middle.
For immediate assistance please call:
• Tech support: 1-888-694-3533
Entire row outage
• Ensure that the breaker is not tripped. If it is, count the number of 8-foot sections on breaker/power
drop. Ensure that it does not exceed 52 x 8-foot sections.
• Check the power connection to the rst master light engine in the row. Note that there will be
multiple circuits coming in the existing uorescent xture, 1 circuit will be tied to the power cord of
the LUR2 series and 2 circuits will be cut. (Visit Product Install sheet)
• If full rows or large sections of store are out, check the breaker at the panel. If the breaker is not
tripped the issue may be related to the control system installed. Please contact the Daintree Controls
team at 866-855-8629 or email [email protected].