Bosch HDS7052C/08 Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

INSTALLATION INSTRUCTIONS
FOR USE WITH BOSCH DUAL FUEL RANGES
NOTICE D'INSTALLATION
À UTILISER AVEC LES FOURS BI-COMBUSTIBLES DE BOSCH
INSTRUCCIONES DE INSTALACIÓN
PARA UTILIZAR CON ESTUFAS DE DOBLE COMBUSTIBLE DE BOSCH
Table of content
Important Safety Instructions ................................................... 3
Preparation ................................................................................ 5
Procedure .................................................................................. 6
Installation of anti-tip bracket ................................................... 6
Prepare Electrical Connection ................................................... 6
Install Electrical Connection ....................................................... 8
Connect Gas Supply ................................................................... 9
Test the Installation ................................................................. 11
Test for Gas Leaks .................................................................... 11
Test Electric Ignition ................................................................ 11
Test/Adjust Flame High Setting ................................................ 11
Service ..................................................................................... 12
Table des matières
Consignes de sécurité importantes ........................................ 13
Préparation .............................................................................. 15
Procédure ................................................................................ 16
Installation de l'étrier anti-bascule .......................................... 16
Préparation du raccordement électrique ................................. 16
Installation du raccordement électrique ................................... 18
Raccordement de l'alimentation en gaz .................................... 19
Vérification de l'installation10
Vérifier les fuites de gaz............................................................ 21
Vérifier l'allumage électrique ................................................... 21
Vérifier/ajuster la flamme : réglage élevé .................................. 21
Dépannage ............................................................................... 22
Índice
Instrucciones de seguridad importantes ................................ 23
Preparación .............................................................................. 25
Procedimiento ......................................................................... 26
Instalación del soporte anticaídas ........................................... 26
Preparar la conexión eléctrica ................................................. 27
Instalar la conexión eléctrica .................................................... 29
Conectar la alimentación de gas............................................... 30
Probar la instalación ................................................................ 32
Realizar una prueba de fugas de gas ........................................ 32
Probar el encendido eléctrico ................................................. 32
Probar/ajustar los valores de llama altos .................................. 33
Servicio técnico ....................................................................... 33
3
, Important Safety Instructions
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS
APPLIANCE.
, WARNING
If the information in this manual is not followed exactly,
a fire or explosion may result causing property damage,
personal injury or death.
Do not store or use combustible materials, gasoline
or other flammable vapors and liquids in the vicinity
of this or any other appliance.
, WARNING
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
Immediately call your gas supplier from
a neighbor’s phone. Follow the gas sup-
plier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be per-
formed by a qualified installer, authorized
service agency or the gas supplier.
, WARNING
TIP OVER HAZARD!
A child or adult can
tip the range over
and be killed.Verify
that the anti-tip
bracket is securely
installed. Ensure the anti-tip bracket is
engaged when the range is moved.
Do not operate the range without the
anti-tip bracket in place. Failure to fol-
low the instructions in this manual can
result in death or serious burns to chil-
dren and adults.
Check for proper installation and use
of anti-tip bracket
Carefully tip range forward pulling from
the back to ensure that the anti-tip
bracket engages the range leg and pre-
vents tip-over. Range should not move
more than 1" (2.5 cm).
Questions?
1-800-944-2904
www.boschappliances.com
We look forward to hearing from you!
4
Before installing, turn power OFF at the service
panel. Lock service panel to prevent power from be-
ing turned ON accidentally.
Remove all tape and packaging before using the range.
Destroy the carton and plastic bags after unpacking the
range. Never allow children to play with packaging mate-
rial.
Be sure your appliance is properly installed and ground
-
ed by a qualified technician in accordance with the Na-
tional Electrical Code ANSI/NFPA No. 7 latest edition and
local electrical code requirements.
Important: Local codes vary. Installation, electrical con-
nections and grounding must comply with all applicable
codes.
Install only per installation instructions included in the
literature package for this range.
Ask your dealer to recommend a qualified technician
and an authorized repair service.
Know how to disconnect the power to the range at the
circuit breaker or fuse box and the gas supply at the shut
-
off in case of an emergency.
Do not repair or replace any part of the appliance un
-
less specifically recommended in the manuals. All other
servicing should be done by a qualified technician. This
may reduce the risk of personal injury and damage to the
range.
When testing the supply piping system at test pressures
in excess of ½ psig (3.5 kPa), the appliance and its indi
-
vidual shutoff valve must be disconnected from the gas
piping system.
When testing the supply piping system at test pressures
equal to or less than ½ psig (3.5 kPa), the appliance
must be isolated from the gas supply piping system by
closing its individual manual shutoff valve.
Never modify or alter the construction of a range by
removing leveling legs, panels, wire covers, anti-tip brack
-
ets/screws, or any other part of the product.
Do not lift door by door handle. Remove the door for
easier handling and installation. See Section “Removing
Oven Door” in Use and Care Manual.
Do not store items of interest to children in the
cabinets above the range or on the backguard of
a range. Children climbing on the range to reach
items could be seriously injured.
, CAUTION
Unit is heavy and requires at least two persons or
proper equipment to move.
Do not use the oven or warming drawer (if
equipped) for storage.
This appliance has been tested in accordance with
the following standards:
• ANSI Z21.1 - Household Cooking Gas Appliances
• UL 858 - Household Electric Ranges
CAN/CSA C22.2 No. 61 - Household Cooking
Ranges
In Canada, installation must be in accordance with
CAN 1-B149.1 and .2 Installation Codes for Gas
Burning Appliances and/or local codes.
For Massachusetts Installations:
1. Installation must be performed by a qualified or
licensed contractor, plumber or gas fitter qualified
or licensed by the state, province or region where
this appliance is being installed.
2. Shutoff valve must be a “T” handle gas cock.
3. Flexible gas connector must not be longer than
36" (91.4 cm).
High Altitude Installation Note:
This range is CSA certified for safe operation up to
an altitude of 10,000 ft. without any modifications.
Exception: for use with LP, the range must first be
converted using the LP conversion instructions in-
cluded in this literature package.
, Important Safety Instructions
READ AND SAVE THESE INSTRUCTIONS
5
Parts provided:
Anti-Tip Bracket
2 wood screws
2 anchorless concrete screws
Tools and parts needed:
Range Power Supply Cord Kit with strain relief
(240V - 30 Amps)*
• Standard Measuring Tape
• Phillips Head Screwdriver
• 1-" Wrench
• Pencil
• T-20 Torx Screwdriver
• " Nut Driver
• Pipe Wrench (2)
Teon® Tape** or Pipe Joint Compound
(Appropriate for use with LP gas and Natural gas)
• Channel Lock Pliers
• Gas Leak Test Solution
• Level
Drill and Drill Bit (3/16“ masonry bit for
concrete screws)
Gas Supply Line (Flexible Metal Appliance
Connector or Rigid Pipe)
• Gas Shut Off Valve (If not already present)
• Gloves and Safety Goggles
* Not needed for Canadian installations
** Teflon is a registered trademark of DuPont
1. Install Ventilation
Bosch strongly recommends the installation of a
ventilation hood above this range. For most kitchens
a certified hood rating of not less than 300 CFM is
recommended. The range hood must be installed ac-
cording to instructions furnished with the hood.
Note: The appliance should not be installed with a
ventilation system that blows air downward toward
the burners. This type of ventilation system may
cause ignition and combustion problems with the
gas cooking appliance resulting in personal injury or
unintended operation.
2. Prepare Cabinets
This unit is designed for installation near adjacent
walls and projected surfaces constructed of combus-
tible materials.
Allow a minimum of 30"(76.2 cm) between cabinets
where range is to be installed**.
30in (76.2 cm)
min. centered
30in (76.2 cm) min.
4in (10.2 cm )
min
4in
(10.2 cm
)
min
no clearance required (12 mm clearance from
range sidewall to cabinet required in Canada.)
Required Clearances*
From cooktop to materials above
There must be a minimum clearance of 30" (76.2 cm)
between the top of the cooking surface and the bot-
tom of an unprotected wood or metal cabinet.
24" (60.7 cm) is acceptable when the bottom of the
wood or metal cabinet is protected by (a) not less
than " (6.4 mm) of ame retardant material which
must be covered with (b) not less than No. 28 MSG
sheet metal, 0.015" (0.4 mm) stainless steel or
0.024" (0.6 mm) aluminum or copper.
From range walls to adjacent materials
No clearance is required from unit walls to adjacent
vertical combustible walls on rear, right or left.
Clearance from range top to adjacent vertical walls
must be at least 4" (10.2 cm).
NOTE: Some cabinet finishes cannot survive the tem-
peratures allowed by U.L., particularly self-cleaning
ovens; the cabinets may discolor or stain. This is
most noticeable with laminated cabinets.
Preparation
6
General Information
Ranges are dual rated for use on either 120/240 VAC
or 120/208 VAC. See chart below for power ratings
and circuit breaker sizes based on the supply voltage
for each model.
MODEL: HDS
VOLTS A.C. HZ RATING KW CIRCUIT BREAKER
120/240 60 6.5 30 AMPS
120/208 60 4.8 30 AMPS
, CAUTION
Make certain that gas shutoff valve and all burner con-
trols are in the OFF position before beginning.
Procedure
Prepare Electrical Connection
Installation of anti-tip bracket
1. Adjust height of range and level by rotating the ad-
justable leg supports on the bottom of the range,
using 1-" (32 mm) wrench.
2. Locate bracket position as shown below.
3. Secure bracket with 2 screws to the floor or to
the wall. Depending on floor or wall material use
wood or anchorless concrete screws (included).
Concrete screws require a 3/16” masonry bit.
Screws should provide firm attachment into solid
wood or flooring. Do not attempt to anchor into
drywall.
3. Prepare Gas Supply Line and Electrical Outlet
The gas supply line and electrical outlet must be
located in the shaded area.
7 1/2"
4 1/2"
13 1/8 "
4"
3 7/8"
4 1/2"
3 1/2"
30"
Place Gas Supply
Line and Electrical
Outlet Here
7 1/2”
4 1/2”
13 1/8”
4” 3 7/8”
3 1/2”
4 1/2”
30”
4. Prepare Walls and Floor
Seal any holes in the walls or floor. Remove any ob-
structions (extra electrical or gas connections, etc.)
so that range will rest against wall properly.
*Instructions were determined using standard American cabinets. Standard
base cabinets measure 36" (91.4 cm) high x 24" (61 cm) deep . Cabinets
over the cooking surface and cabinets adjacent to those over the cooking
surface measure 13" (33 cm) deep from backwall. If nonstandard cabinets
are used, care should be taken to alter dimensions accordingly.
** 12 mm clearance from range sidewall to cabinet required in Canada.
7
Verify that wiring to house is adequate. Contact your
local utility company to verify that the present electric
service to your home is adequate. In some instances,
the size of the wiring to the house and service switch
must be increased to handle the electrical load de-
manded by the range.
Verify that wiring inside house is adequate.
Most wiring codes require a separate circuit with
separate disconnect switch and fuses either in the
main entrance panel or in a separate switch and fuse
box.
The range requires a three wire 120/240 or
120/208 volt, 30 AMP, 60 Hz AC circuit.
Most local building regulations and codes require that
electrical wiring be done by licensed electricians. Be
sure to install your range according to the electric
codes in place in your region.
,
WARNING
To prevent electrical shock, the grounding prong on
the range cord should not be cut or removed under
any circumstances. It must be plugged into a match-
ing grounding type receptacle and connected to a
correctly polarized 240- Volt circuit. If there is any
doubt as to whether the wall receptacle is properly
grounded, have it checked by a qualified electrician.
Bosch recommends that the range be installed with
a power cord set (not supplied)*. The electrical
rating of the power cord set must be 120/240 volt,
30 amperes minimum. The power cord set shall be
marked “For Use with Ranges.” Always use a new
power cord.
NOTE: In Canada, the range is shipped from the fac-
tory with the range cord already installed. Proceed
to “Connect Gas Supply”.
For installations other than those in Canada, connect
the range cord at the terminal block (See “Install
Electrical Connection”). Access the terminal block by
removing the cover in the lower right hand corner of
the range back panel. Install the strain relief and the
proper connector through the knockout(s) provided.
The electrical supply, including flexible conduit or
power cord, should be restricted to the shaded
areas (page 5).
Install Strain Relief
Place strain relief in knockout below terminal block.
Feed range cord through hole and strain relief up
to terminal block. Allow for slack in the cord be-
tween the strain relief and terminal block. Once cord
length/slack has been adjusted, attach strain relief
per instructions included with strain relief.
Electric Connection (found
behind terminal block
cover)
Gas Connection
Feed
Range
Cord
Through
Strain
Relief in
Knockout
Panel
Here
, WARNING
The strain relief provided with your range cord must
be properly installed.
Tip:
The knockout panel below the terminal block
can be removed from the range to install the
strain relief: Remove knockout panel from range,
install strain relief in panel and reattach. DO
NOT remove entire range back panel.
, WARNING
Risk of Electric Shock or Fire. Frame grounded to
neutral through a ground strap. Grounding through the
neutral conductor is prohibited for new branch-circuit
installations (1996 NEC), mobile homes, and
recreational vehicles, or in an area where local codes
prohibit grounding through the neutral conductor.
For installations where grounding through the neutral
conductor is prohibited, (a) disconnect the link from
the neutral, (b) use grounding terminal or lead to
ground unit, (c) connect neutral terminal to lead branch
circuit neutral in usual manner (when the appliance is
to be connected by means of a cord kit, use
4-conductor cord for this purpose).
Use only cord kits rated 125/250 volts (minimum),
30 amperes and labeled “For Use with Ranges”.
Strain relief provided with cord must be installed per
instructions included with cord.
8
Three Wire Connection
The Four Wire Connection is preferred, but where
local codes and ordinances permit grounding
through neutral and/or conversion to four wire is
impractical, unit may be connected to the power
supply via a three wire connection.
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove top nut, star washer, and round washer
from each post.
NOTE: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Attach white wire, round washer, star washer and
nut IN THIS ORDER on top of ground strap on
center post.
5. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
6. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post.
White
Red
Black
Ground Strap
7. Tighten all connections securely and replace ter-
minal block cover.
Red
White
Black
Ground
Strap
Green Ground Screw
8. Properly secure strain relief (see page 7).
Four Wire Connection (Preferred to three wire con-
nection).
1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the
terminal block.
3. Remove top nut, star washer, and round washer
from each post.
NOTE: DO NOT remove last round washer, last nut or
internal wiring leads.
4. Remove screw from bottom end of ground strap.
5. Remove ground strap from center post, rotate so
that wide end is at top and attach wide end to
range through hole below junction box. Attach
green wire on top of ground strap. Tighten Screw.
Green Ground Screw
Ground
Strap
Green
6. Attach red wire, round washer, star washer and
nut IN THIS ORDER to left post.
7. Attach white wire, round washer, star washer and
nut IN THIS ORDER to center post.
Install Electrical Connection
9
Connect Gas Supply
Important note for LP users: The range is shipped
from the factory for use with natural gas. For use
with propane (LP) gas, your range must first be con-
verted using the LP conversion kit.
The gas connection is located below the back panel
of the range (page 7). It is accessible through the
warming drawer access panel or from the back of
the range. To reach access panel, remove warming
drawer.
Shut off main gas supply valve before disconnecting
the old range and leave it off until the new hook-up
has been completed. Don’t forget to relight the pi-
lot on other gas appliances when you turn the gas
back on.
The range can be installed using rigid pipe or a CSA
International-certified flexible metal appliance con-
nector. If using a flexible connector, always use a
new connector.
Apply pipe joint compound or Teflon** tape appropri-
ate for use with LP gas and Natural gas around all
male pipe threads to prevent leaks.
If not already present, install gas shut off valve in an
easily accessible location. Make sure all users know
where and how to shut off the gas supply to the
range.
NOTE: The installer should inform the consumer of
the location of the gas shutoff valve.
Flexible Connector Method
Gas Shut-
Off Valve
Flexible
Connector
Regulator
1. Install male ½" (12.7 mm) flare adaptor at the ½"
(12.7 mm) NPT internal thread of the range inlet.
Use a backup wrench on the elbow fitting to avoid
damage.
2. Install male ½" (12.7 mm) or ¾" (19 mm) flare
union adapter on the NPT internal thread of the
manual shutoff valve.
3. Connect flexible metal appliance connector.
, CAUTION
Before you plug in an electrical cord, be sure all con-
trols are in the OFF position.
4. Make sure circuit breaker is off and then plug
range cord into electrical outlet.
5. Slide range into position ensuring that the left
back leg slides under the anti-tip bracket. Range
will sit ¾" (19 mm) away from back wall when
properly installed.
NOTE: Be careful not to crimp flexible connector!
8. Attach black wire, round washer, star washer and
nut IN THIS ORDER to right post.
Red
White
Black
9. Tighten all connections securely and replace ter-
minal block cover.
10. Properly secure strain relief (see previous page).
NOTE: DO NOT plug in range at this time. Proceed to
“Connect Gas Supply”.
10
6. Carefully tip range forward pulling from the back
to ensure that the anti-tip bracket engages the
range leg and prevents tip-over.
Rigid Pipe Method
gas shut off valve
elbow
nipple
nipple
nipple
union
elbow
1/2” to 3/4”
gas pipe
Gas Flow to Range
elbow:
connect to
regulator here
The configuration of the rigid pipe connection will
vary depending on the location of the gas pipe stub.
Refer to figure above for details.
, CAUTION
Before you plug in an electrical cord, be sure all con-
trols are in the OFF position.
1. Make sure circuit breaker is off and then plug
range cord into electrical outlet.
2. Slide range into position ensuring that the left
back leg slides under the anti-tip bracket. Range
will sit ¾" (19 mm) away from back wall when
properly installed.
3. Carefully tip range forward pulling from the back
to ensure that the anti-tip bracket engages the
range leg and prevents tip-over.
4. Connect pipe to range at union. Access the con-
nection through the access panel behind the
warming drawer.
NOTE: Be careful not to apply pressure to warming
drawer element during rigid pipe installation.
** Teflon is a registered trademark of DuPont
11
Test the Installation
Leak testing is to be conducted by the installer ac-
cording to the instructions given in this section.
Turn on Gas. Apply a non-corrosive leak detection
fluid to all joints and fittings in the gas connection
between the shutoff valve and the range. Include gas
fittings and joints in the range if connections may
have been disturbed during installation. Bubbles
appearing around fittings and connections indicate
a leak.
If a leak appears, turn off supply line gas shutoff
valve and tighten connections. Retest for leaks by
turning on the supply line gas shutoff valve. When
leak check is complete (no bubbles appear), test is
complete. Wipe off all detection fluid residue.
, CAUTION
Never check for leaks with a flame.
Do not continue to the next step until all leaks are
eliminated.
Test for Gas Leaks
Turn on power at breaker.
, CAUTION
If the display flashes and beeps, the polarity of
the wiring may be reversed. Reversed polarity can
damage the range and can result in electrical shock
hazard. Immediately switch off power at the breaker
and return to “Install Electrical Connection”.
Select a rangetop burner knob. Push down and turn
to the flame symbol. If the ignitor/spark module is
operating correctly, it will produce a clicking sound.
Once the air has been purged from the supply lines,
the burner should light within four (4) seconds. After
burner lights, turn knob to the OFF position.
Test each rangetop burner in this fashion.
Call Bosch Service at 800-944-2904 if any of the
burners do not light.
Some yellow streaking is normal during the initial
start-up. Allow unit to operate 4-5 minutes and
reevaluate before making adjustments.
Checking Flame Characteristics
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LP Gas.
Soft Blue Flames:
Normal for Natural Gas.
Test Electric Ignition
High Setting
The combustion quality of the flame for each burner
must be visually inspected. For propane, the flame
should be blue with yellow tips. For natural gas, it
should be soft blue in color. The flame should carry over,
or surround, the entire burner and should not lift or
blow off the burner.
To inspect, turn the burner on. See figure on this side for
appropriate flame characteristics.
If the flame is completely or mostly yellow, verify that
the regulator is set for the correct fuel. After adjustment,
retest. If any of the burners continue to burn mostly or
completely yellow, call Bosch Service 800-944-2904.
NOTE: With LP use, some yellow tipping on outer cones
is normal.
Low Setting
All burners must also be inspected for carry-over. On
low, the flame should completely surround the burner.
If any of the cooktop burners do not carry over on the
low setting, call Bosch Service 800-944-2904.
Installation is complete at this time.
When properly adjusted:
There should be a flame at each burner port.
There should be no air gap between the flame and
burner.
Test/Adjust Flame
Replacement Parts: Visit your Bosch dealer for
replacement parts. For a dealer near you contact
Bosch Service at 800-944-2904.
12
Service
See Use and Care Manual for troubleshooting infor-
mation. Refer to the Warranty in the Use and Care
Manual.
To reach a service representative, see the contact
information at the front of the manual. Please be
prepared with the information printed on your pro-
duct data plate when calling.
Product Data Plate
The data plate shows the model and serial number.
Refer to the data plate on the appliance when re-
questing service. It is located on the frame near the
drawer.
Open the drawer to view it.
Before Calling Service
Data Plate
13
, Consignes de sécurité importantes
LIRE ET CONSERVER CES CONSIGNES
VEUILLEZ LIRE TOUTES LES CONSIGNES AVANT
D'UTILISER CET APPAREIL.
, AVERTISSEMENT
Si les informations de ce manuel ne sont pas suivies à la
lettre, un incendie ou une explosion peuvent se produire
entraînant des dommages matériels, des lésions corpo-
relles ou la mort.
Ne pas ranger ou utiliser de matériaux combustibles,
d'essence ou d'autres liquides et vapeurs inflamma-
bles à proximité de cet appareil ou d'aucun autre
appareil.
, AVERTISSEMENT
QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ :
Ne tentez pas d'allumer un appareil, quel
qu'il soit.
Ne touchez à aucun interrupteur électrique.
N'utilisez pas les téléphones de votre
immeuble.
Téléphonez immédiatement à votre
fournisseur de gaz de chez un voisin.
Suivez les instructions du fournisseur
de gaz.
Si vous ne parvenez pas à joindre votre
fournisseur de gaz, appelez le service
d'incendie.
L'installation et les réparations doivent
être effectuées par un installateur quali-
fié, un organisme de service autorisé ou
le fournisseur de gaz.
, AVERTISSEMENT
RISQUE DE BASCULEMENT!
Un enfant ou un
adulte peut faire
basculer le four et
être tué. Vérifiez
que l’étrier anti-bas-
cule est bien installé. Assurez-vous que
l’étrier anti-bascule est en place lorsque
le four est déplacé.
N’utilisez pas le four sans que l’étrier
anti-bascule soit en place. Un manque-
ment à suivre les instructions de ce
manuel peut causer la mort ou des
brûlures graves à des enfants ou des
adultes.
Vérifiez que l'étrier anti-bascule est
installé et utilisé
de façon convenable.
Pour ce faire, faites basculer doucement
le four vers l'avant en tirant de l'arrière
pour vous assurer que l'étrier anti-
bascule est ancré à la patte du four et
empêche l'appareil de basculer. Le four
ne devrait pas bouger de plus de 2,5 cm
(1 pouce).
Questions?
1-800-944-2904
www.boschappliances.com
Il nous fait toujours plaisir de recevoir vos
commentaires!
14
Avant l'installation, coupez le courant au panneau de
service. Verrouillez le panneau de service pour éviter
que le courant ne soit accidentellement rétabli.
Retirez les rubans adhésifs et l'emballage avant d'utili-
ser l'appareil. Débarrassez-vous de la boîte et des sacs de
plastique après avoir déballé l'appareil. Ne laissez jamais
les enfants jouer avec des matériaux d'emballage.
Assurez-vous que votre appareil est installé convenable
-
ment et mis à la terre par un technicien qualifié en res-
pectant les exigences de la plus récente édition du Code
national de l'électricité ANSI/NFPA No. 7 et les autres
exigences des codes de l'électricité locaux.
Important : Les codes locaux peuvent différer. L'installa-
tion, les raccordements électriques et la mise à la terre
doivent être conformes à tous les codes applicables.
Procédez à l'installation uniquement en suivant les
instructions d'installation comprises dans la documenta
-
tion fournie avec cet appareil.
Demandez à votre détaillant de vous recommander un
technicien qualifié et un service de réparation autorisé.
Apprenez à débrancher l'alimentation électrique de l'ap
-
pareil par le disjoncteur ou par les fusibles et à fermer le
robinet d'arrêt de l'alimentation en gaz en cas d'urgence.
Ne réparez pas ou ne remplacez pas des pièces de l'ap
-
pareil à moins que cela ne soit expressément recom-
mandé dans les manuels. Tous les travaux d'entretien de-
vraient être confiés à un technicien qualifié. Vous pourrez
ainsi réduire les risques de blessures personnelles et de
dommages à l'appareil.
L'appareil et son robinet d'arrêt individuel doivent être
isolés de la tuyauterie d'alimentation en gaz lorsque
vous effectuez des tests de pression à une pression
d'épreuve dépassant 3,5 kPa (½ psi).
L'appareil doit être isolé de la tuyauterie d'alimentation
en gaz en fermant le robinet d'arrêt manuel individuel
lorsque vous effectuez des tests de pression sur la
tuyauterie d'alimentation en gaz à une pression d'épreu
-
ve égale ou inférieure à 3,5 kPa (1/2 psi).
Ne modifiez pas ou n'altérez pas l'assemblage d'un ap
-
pareil en enlevant des pattes, des panneaux, des couvre-
fils, des vis ou des étriers anti-bascules ou toute autre
partie du produit.
Ne soulevez pas l'appareil par la poignée de la porte. En
-
levez la porte pour faciliter la manipulation et l'installation
de l'appareil. Voir la section « Retrait de la porte du four »
dans le manuel d'utilisation et d'entretien.
Ne placez pas des objets destinés aux enfants
dans les armoires situées au-dessus ou sur le dos-
seret d'un appareil. Des enfants qui grimperaient
sur l'appareil pour prendre ces objets pourraient
se blesser sérieusement.
, ATTENTION
Cet appareil est lourd et il faut au moins deux per-
sonnes ou l'équipement approprié pour le déplacer.
N'utilisez pas le four ou le tiroir-réchaud (si compris)
pour le rangement.
Cet appareil a été testé conformément aux normes
suivantes :
ANSI Z21.1, norme nationale américaine
pour appareils ménagers de cuisson au gaz
UL 858 - Household Electric Ranges
CAN/CSA-C 22.2 n° 61-M89, cuisinières ménagères
Au Canada, l'installation doit être conforme aux co-
des d'installation CAN 1-B149.1 et .2 pour les appa-
reils à gaz et/ou aux codes locaux.
Installations effectuées dans l'état du Massachu-
setts :
1. L'installation doit être effectuée par un entrepre-
neur qualifié ou titulaire d'une licence, un plom-
bier ou installateur de gaz qualifié ou titulaire
d'une licence octroyée par l'état, la province ou la
région où l'appareil est installé.
2. Le robinet d'arrêt doit être pourvu d'une poignée
en « T ».
3. Le connecteur à gaz flexible ne doit pas être plus
long que 91,4 cm (36 po).
Note concernant l'installation à haute altitude :
Cet appareil est approuvé par le CSA pour un fonc-
tionnement sécuritaire jusqu’à une altitude de 3048
m (10 000 pi) sans modification. Exception : pour
l'utilisation avec du gaz LP, l'appareil doit d'abord
être converti à l'aide des instructions de conversion
pour le gaz LP comprises avec la documentation
fournie.
, Consignes de sécurité importantes
LIRE ET CONSERVER CES CONSIGNES
15
Pièces incluses :
Étrier anti-bascule
2 vis à bois
2 vis à béton sans ancre
Outils et pièces nécessaires :
Ensemble de cordon d'alimentation pour four avec ser-
re-câble (240 V - 30 A)*
• Ruban à mesurer standard
• Tournevis à tête Phillips
• Clé de 31,8 mm (1-1/4 po)
• Crayon
• Tournevis Torx T-20
• Tournevis à douille de 10 mm (3/8 po)
• Clés à tuyau (2)
Ruban Teon
MD
** ou pâte isolante à joint
(pour le gaz LP ou le gaz naturel)
• Pince multiprise ordinaire
• Solution pour tester les fuites de gaz
• Niveau
Perceuse et mèche (mèche à maçonnerie de 4,8 mm
ou 3/16 po pour les vis à béton)
Canalisation d'alimentation en gaz (connecteur d'appa-
reil en métal flexible ou tuyau rigide)
• Robinet d'arrêt du gaz (s'il n'est pas déjà présent)
• Gants et lunettes de sécurité
* N'est pas nécessaire pour les installations au Canada
** Teflon est une marque déposée de DuPont
1. Installation de la ventilation
Bosch recommande fortement d'installer une hotte au-
dessus de cet appareil. Pour la plupart des cuisines, une
hotte certifiée offrant au moins 91 m
3
/min (300 CFM) est
recommandée. La hotte doit être installée conformément
aux instructions qui l'accompagnent.
Remarque : L’appareil ne devrait pas être installé avec
un système de ventilation qui souffle l’air vers les brû-
leurs. Ce type de système de ventilation peut causer des
problèmes d’allumage et de combustion avec l’appareil
de cuisson au gaz et pourrait provoquer des blessures ou
nuire au fonctionnement normal.
2. Préparation des armoires
Cet appareil est conçu pour une installation près de murs
adjacents et de surfaces de projection fabriqués de maté-
riaux combustibles.
Laissez au moins 76,2 cm (30 po) d'espace entre les
armoires à l'endroit où l'appareil sera installé.**
76,2 cm (30 po)
centré
76,2 cm (30 po) min.
10,2 cm (4 po)
min.
10,2 cm (4 po)
min.
aucun espacement requis (12 mm d'espacement entre est requis
entre les côtés de l'appareil et les armoires au Canada).
Espacements requis*
De la surface de cuisson jusqu'aux matériaux au-dessus
Il doit y avoir un espacement de 76,2 cm (30 po) entre le
haut de la surface de cuisson et le bas d’une armoire en
métal ou en bois non protégé.
Un espacement de 60,7 cm (24 po) est acceptable lors-
que le bas de l’armoire en métal ou en bois est protégé
par (a) au moins 6,4 mm (1/4 po) de matériel ignifuge
qui doit être recouvert (b) d'au moins 0,4 mm (0,015 po)
de feuille de métal n
o
28 MSG, ou de 0,6 mm (0,024 po)
d'aluminium ou de cuivre.
Des parois de l'appareil aux matériaux adjacents
Aucun espacement n’est nécessaire entre les parois de
l’appareil et les murs verticaux combustibles à l'arrière,
sur la droite et sur la gauche.
L'espacement entre le haut de la cuisinière et les murs
verticaux adjacents doit être d’au moins 10,2 cm (4 po).
Remarque : Certains finis d'armoire ne peuvent résister
aux températures permises par U.L., particulièrement
dans le cas des fours autonettoyants. Les armoires
peuvent se décolorer ou se tacher, tout particulièrement
dans le cas des armoires laminées.
3. Préparation de la canalisation d'alimentation en gaz
et de la prise électrique
La canalisation d'alimentation en gaz et la prise électri-
que doivent se trouver dans la zone ombragée.
Préparation
16
Informations générales
Les appareils ont une cote jumelée pour une utilisa-
tion avec le 120/240 VAC ou le 120/208 VAC. Consul-
tez le tableau ci-dessous pour la puissance nominale
et la taille des disjoncteurs en fonction de la tension
d'alimentation de chaque modèle.
MODÈLE : HDS
VOLTS C.A HZ PUISSANCE
KW
DISJONCTEUR
120/240 60 6,5 30 A
120/208 60 4,8 30 A
, ATTENTION
Assurez-vous que le robinet d'alimentation en gaz et
les commandes des brûleurs sont à la position -
SACTIVER avant de commencer.
Vérifiez que le câblage desservant la résidence est
adéquat. Contractez votre distributeur d'électricité
local pour vous assurer que le service électrique ac-
tuel de votre maison est adéquat. Dans certains cas,
la dimension du câblage et l'interrupteur de service
doivent être augmentés pour répondre à la charge
électrique requise par l'appareil.
Préparation du raccordement électrique
Procédure
Installation de l'étrier anti-bascule
1. Ajustez la hauteur du four et mettez-le à niveau en
faisant tourner les supports ajustables des pattes
au bas du four à l'aide d'une clé de 32 mm (1-1/4 po).
2. Placez l'étrier tel qu'illustré ci-dessous.
3. Fixez l'étrier au plancher ou au mur à l'aide de
2 vis. En fonction des matériaux du plancher
ou du mur, utilisez des vis en bois ou des vis à
béton sans ancre (comprises). Les vis à béton
nécessitent une mèche à maçonnerie de 4,8 mm
(3/16 po). Les vis devraient offrir une fixation so-
lide dans le bois ou un plancher ferme. Ne tentez
pas de fixer l'étrier dans une cloison sèche.
7 1/2"
4 1/2"
13 1/8 "
4"
3 7/8"
4 1/2"
3 1/2"
30"
Placez la canalisation
d'alimentation en gaz et
la prise électrique ici
7 1/2”
4 1/2”
13 1/8”
4” 3 7/8”
3 1/2”
4 1/2”
30”
4. Préparation des murs et du plancher
Scellez les trous dans les murs et le plancher. Enlevez
tous les obstacles (raccordements électriques ou de gaz
en surplus, etc.) afin que l'appareil soit positionné cor-
rectement contre le mur.
* Les instructions ont été déterminées en utilisant des armoires américaines stan-
dard. Les armoires de base standard mesurent 91,4 cm (36 po) de haut par 61
cm (24 po) de profondeur. Les armoires au-dessus de la surface de cuisson et les
armoires adjacentes à celles au-dessus de la surface de cuisson mesurent 33 cm
(13 po) de profondeur à partir du mur arrière. Si des armoires non standard sont
utilisées, assurez-vous de modier les dimensions de façon appropriée.
** Un espacement de 12 mm est requis entre les côtés de l'appareil et les armoi
-
res au Canada.
17
Vérifiez que le câblage intérieur est adéquat.
La plupart des codes de câblage exigent un circuit
seul et un interrupteur général et des fusibles sépa-
rés dans le panneau principal ou dans un boîtier de
fusibles avec interrupteur distinct.
L'appareil nécessite un circuit 120/240 ou 120/208 V,
30 A, 60 Hz de trois fils.
La plupart des règlements de construction et des
codes locaux requièrent que le câblage électrique soit
installé par un électricien qualifié. Assurez-vous d'ins-
taller l'appareil conformément aux codes électriques
applicables dans votre région.
,
AVERTISSEMENT
Pour éviter les chocs électriques, la broche de
mise à la terre du cordon ne doit en aucun cas être
coupée ou enlevée. Elle doit être branchée sur une
prise avec mise à la terre correspondante et reliée à
un circuit 240 volts adéquatement polarisé. En cas de
doute concernant la mise à la terre appropriée de la
prise murale, faites vérifier la prise par un électricien
qualifié.
Bosch recommande que l'appareil soit installé avec
un ensemble de cordon d'alimentation (non com-
pris)*. Les caractéristiques électriques de l'ensemble
de cordon d'alimentation devraient être au moins
120/240 volt, 30 ampères. L'ensemble de cordon
d'alimentation doit porter la mention « À utiliser avec
les fours ». Utilisez toujours un cordon d'alimenta-
tion neuf.
NOTE : Au Canada, la cuisinière est expédiée de
l’usine avec un cordon d’alimentation déjà installé.
Passez à la section « Raccordement de l'alimentation
en gaz ».
Pour les installations à l'extérieur du Canada, bran-
chez le cordon de l'appareil au bloc de bornes (voir
la section « Installation du raccordement électri-
que »). Accédez au bloc de bornes en enlevant le
couvercle dans le coin inférieur droit du panneau
arrière de l'appareil. Installez le serre-câble et le
connecteur approprié à travers le ou les panneau(x)
amovible(s) fourni(s). Les éléments de l'alimentation
électrique, y compris le câble flexible ou le cordon
d'alimentation, devraient être confinés à la section
ombragée (page 15).
Installation du serre-câble
Placez le serre-câble dans le panneau amovible sous
le bloc de bornes. Faites passer le cordon dans le
trou et le serre-câble jusqu'au bloc de bornes. Lais-
sez un peu de jeu au cordon entre le serre-câble et le
bloc de bornes. Une fois que la longueur et le jeu du
cordon ont été ajustés, fixez le serre-câble conformé-
ment aux instructions concernant son installation.
Faites passer
le cordon dans
le trou et le
serre-câble
du panneau
amovible ici
Raccordement électrique
(se trouve derrière le couvercle
du bloc de bornes)
Connexion de gaz
, AVERTISSEMENT
Le serre-câble inclus avec votre appareil doit être
installé convenablement.
Conseil :
Le panneau amovible sous le bloc de bor-
nes peut être retiré de l'appareil au cours de
l'installation du serre-câble : Retirez le panneau
amovible de l'appareil, installez le serre-câble et
replacez ensuite le panneau. NE RETIREZ PAS
tout le panneau arrière de l'appareil.
, AVERTISSEMENT
Risque de chocs électriques ou d'incendie.
Le cadre est mis à la terre au neutre par une
bande de mise à la terre. La mise à la terre
par le conducteur neutre est interdite dans
les installations comprenant de nouveaux
circuits de dérivation (CNÉ 1996), les maisons
mobiles et les véhicules créatifs, ou dans
les endroits où les codes locaux interdisent la
mise à la terre par le conducteur neutre.
Pour les installations où la mise à la terre par
le conducteur neutre sont interdites,
(a) débranchez le lien du conducteur neutre,
(b) utilisez le terminal de mise à la terre ou la
borne de l'unité de mise à la terre, (c) raccordez
le terminal neutre à la borne du circuit de
dérivation de la façon habituelle (lorsque
l'appareil est raccordé à l'aide d'un ensemble
de cordon d'alimentation, utilisez le cordon
à 4 conducteurs à cette fin).
Utilisez seulement les ensembles de cordon
d'alimentation de 135/250 volts (au minimum),
30 ampères et portant la mention « À utiliser
avec les fours ».
Le serre-câble fourni avec le cordon d'alimentation
doit être installé conformément aux instructions
qui l'accompagnent.
RACCORDEMENT À 3 FILS
FIL ROUGE
(NEUTRE)
FIL BLANC
FIL NOIR
RACCORDEMENT À 4 FILS
FIL ROUGE
(NEUTRE)
FIL BLANC
FIL NOIR
MISE À LA TERRE VERTE
18
Raccordement à trois fils
Un raccordement à quatre fils est préférable, mais aux
endroits où les codes et les règlements locaux permet-
tent la mise à la terre par le conducteur neutre et/ou la
conversion à quatre fils ne peut être considérée, l'appa-
reil peut être branché à l'alimentation électrique par un
raccordement à trois fils.
1. Débranchez l'alimentation électrique au niveau des
disjoncteurs.
2. Retirez le couvercle du bloc de bornes pour exposer
le bloc.
3. Enlevez l'écrou supérieur, la rondelle en étoile et la
rondelle ronde de chaque tige.
NOTE : NE PAS ENLEVER la dernière rondelle ronde, le
dernier écrou ou les éléments du câblage interne.
4. Fixez le fil blanc, la rondelle ronde, la rondelle en
étoile et l'écrou DANS CET ORDRE sur la bande de
mise à la terre de la tige centrale.
5. Fixez le fil rouge, la rondelle ronde, la rondelle en
étoile et l'écrou DANS CET ORDRE sur la tige gauche.
6. Fixez le fil noir, la rondelle ronde, la rondelle en étoile
et l'écrou DANS CET ORDRE sur la tige droite.
Rouge
Bande de mise à la terre
Blanc
Noir
7. Serrez tous les raccordements adéquatement et repla-
cez le couvercle du bloc de bornes.
Rouge
Bande de
mise à la terre
Vis verte de mise à la terre
Blanc
Noir
8. Fixez solidement le serre-câble (voir la page 17).
Raccordement à quatre fils (préférable au raccorde-
ment à trois fils)
1. Débranchez l'alimentation électrique au niveau des
disjoncteurs.
2. Retirez le couvercle du bloc de bornes pour exposer
le bloc.
3. Enlevez l'écrou supérieur, la rondelle en étoile et la
rondelle ronde de chaque tige.
NOTE : NE PAS ENLEVER la dernière rondelle ronde, le
dernier écrou ou les éléments du câblage interne.
4. Retirez la vis au bas de la bande de mise à la terre.
5. Enlevez la bande de mise à la terre de la tige centrale
et faites-la pivoter pour que l'extrémité la plus large
soit sur le dessus et fixez ensuite cette extrémité
à l'appareil par le trou sous la boîte de connexion.
Fixez le fil vert sur la bande de mise à la terre. Serrez
ensuite l'écrou.
Bande de
mise à la terre
Vert
Vis verte de mise à la terr
e
6. Fixez le fil rouge, la rondelle ronde, la rondelle en
étoile et l'écrou DANS CET ORDRE sur la tige gauche.
7. Fixez le fil blanc, la rondelle ronde, la rondelle en
étoile et l'écrou DANS CET ORDRE sur la tige centrale.
Installation du raccordement électrique
19
Raccordement de l'alimentation de gaz
Note importante pour les utilisateurs de gaz LP :
Cet appareil est conçu à sa sortie de l'usine pour
fonctionner au gaz naturel. Pour être utilisé avec du
gaz LP (propane), votre appareil doit d'abord être
converti à l'aide d'un ensemble de conversion LP.
Le raccord de gaz se trouve sous le panneau arrière
de l'appareil (page 17). Il est accessible à partir du
panneau d'accès du tiroir-réchaud ou de l'arrière de
l'appareil. Pour accéder au panneau d'accès, enlevez
le tiroir-réchaud.
Fermez le robinet d'alimentation en gaz principal
avant de débrancher votre vieil appareil et assurez-
vous qu'il demeure fermé jusqu'à ce que l'installation
soit terminée. N'oubliez pas de rallumer la flamme
de veilleuse des autres appareils au gaz en rétablis-
sant l'alimentation en gaz.
L'appareil peut être installé en employant un tuyau
rigide ou un connecteur d'appareil en métal flexible
certifié CSA International. Si vous utilisez un connec-
teur flexible, assurez-vous qu'il soit neuf.
Appliquez de la pâte isolante à joint ou du ruban Te-
on** conçu pour le gaz naturel ou le gaz LP autour
de tous les filets des tuyaux mâles afin d'éviter les
fuites.
S'il n'est pas déjà présent, installez le robinet d'arrêt
du gaz à un endroit facile d'accès. Assurez-vous que
tous les usagers de l'appareil connaissent la façon et
l'endroit permettant d'arrêter l'alimentation en gaz
du four.
NOTE : L'installateur devrait informer le client de
l'endroit où se trouve le robinet d'arrêt du gaz.
Méthode avec connecteur flexible
Robinet d'art
du gaz
Régulateur
Connecteur
flexible
1. Installez un adaptateur mâle évasé de 12,7 mm (½
po) au point 12,7 mm (½ po) du filetage interne
NPT de l'entrée de l'appareil. Utilisez une clé sur
le raccord en coude pour éviter tout dommage.
2. Installez un adaptateur mâle évasé de 12,7 mm (½
po) ou 19 mm (¾ po) sur le filetage interne NPT
du robinet d'arrêt manuel.
3. Raccordez le connecteur d'appareil en métal flexible.
, ATTENTION
Avant de brancher le cordon électrique, vérifiez que
toutes les commandes sont dans la position "OFF"
(Arrêt).
8. Fixez le fil noir, la rondelle ronde, la rondelle en étoile
et l'écrou DANS CET ORDRE sur la tige droite.
Rouge
Blanc
Noir
9. Serrez tous les raccordements adéquatement et repla-
cez le couvercle du bloc de bornes.
10. Fixez solidement le serre-câble (voir la page précé-
dente).
NOTE : NE BRANCHEZ PAS l'appareil à cette étape.
Passez à la section « Raccordement de l'alimentation
en gaz ».
20
4. Assurez-vous que le disjoncteur est désactivé
avant de brancher le cordon d'alimentation de
l'appareil dans la prise électrique.
5. Faites glisser l'appareil en position en vous assu-
rant que la patte arrière gauche glisse sous l'étrier
anti-bascule. L'appareil devrait normalement se
trouver à 19 mm (3/4 po) du mur arrière dans une
installation appropriée.
NOTE : Assurez-vous de ne pas écraser le connecteur
flexible!
6. Faites basculer doucement le four vers l'avant en
tirant de l'arrière pour vous assurer que l'étrier an-
ti-bascule est ancré à la patte du four et empêche
l'appareil de basculer.
Méthode avec tuyau rigide
Circulation du gaz
vers l'appareil
coude :
branchez le
gulateur ici
raccord file
raccord file
raccord
du tuyau
coude
coude
robinet d'art du gaz
tuyau de gaz de 12,7 mm
(1/2 po) ou 19 mm (3/4 po)
raccord file
La configuration de raccordement avec tuyau rigide
variera en fonction de l'endroit où se situe l'entrée
du tuyau de gaz. Consultez l'image ci-dessus pour de
plus amples renseignements.
, ATTENTION
Avant de brancher le cordon électrique, vérifiez que
toutes les commandes sont dans la position "OFF"
(Arrêt).
1. Assurez-vous que le disjoncteur est désactivé
avant de brancher le cordon d'alimentation de
l'appareil dans la prise électrique.
2. Faites glisser l'appareil en position en vous assu-
rant que la patte arrière gauche glisse sous l'étrier
anti-bascule. L'appareil devrait normalement se
trouver à 19 mm (¾ po) du mur arrière dans une
installation appropriée.
3. Pour ce faire, faites basculer doucement le four
vers l'avant en tirant de l'arrière pour vous assurer
que l'étrier anti-bascule est ancré à la patte du
four et empêche l'appareil de basculer.
4. Raccordez le tuyau à l'appareil au raccord-union.
Accédez au raccord par le panneau d'accès à l'ar-
rière du tiroir-réchaud.
NOTE : Faites attention de ne pas appliquer de pres-
sion sur l'élément de cuisson du tiroir-réchaud au
cours de l'installation du tuyau rigide.
** Teflon est une marque déposée de DuPont
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Bosch HDS7052C/08 Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à