Legrand FS-155/155-1 Line Voltage Fixture Mount Occupancy Sensor Mode d'emploi

Taper
Mode d'emploi

Ce manuel convient également à

Wattstopper
®
Occupancy Sensor Line Voltage Fixture Mount
Installation Instructions • Instructions d’Installation • Instrucciones de Instalación
No: 24741 – 06/17 rev. 1
Catalog Numbers • Les Numéros de Catalogue • Números de Catálogo: FS-155 and FS-155-1
Country of Origin: Made in China • Pays d’origine: Fabriqué en Chine • País de origen: Hecho en China
SPECIFICATIONS
Voltages ................................................ 120 - 277VAC, 60Hz
Load Requirements
@ 120VAC ..................... 0-800W ballast or incandescent
@ 277VAC .............................................. 0-1200W ballast
Time Delay ..................................... 30 seconds - 30 minutes
Coverage @ 8’ height ........................................ 10’ diameter
Operating Temperature ..................32° to 131°F (0° to 55°C)
Dimensions
Sensor body ....... 7 1/8’ x 7/8” x 11/16” (181 x 22 x 17mm)
Threaded Neck Length .................................0.35” ((9mm)
Threaded Neck Diameter ..............9/16” diameter (14mm)
Lens Collar Diameter
FS-155 ......................................................... 1” (25mm)
FS-155-1 .................................................... 1.2” (30mm
DESCRIPTION AND OPERATION
The FS-155 and FS-155-1 occupancy sensors turn lighting on and off based on occupancy. These slim, low-profile sensors are
designed for installation inside the bottom of a light fixture body. The PIR lens views the coverage area through a 9/16” diameter hole in
the bottom of the fixture.
The sensors use passive infrared (PIR) sensing technology that reacts to changes in infrared energy (moving body heat) within the
coverage area. Once the space is vacant and the time delay elapses (adjustable from 30 seconds to 30 minutes), lights will turn off.
Sensors must directly “see” motion of an occupant to detect them, so careful consideration must be given to sensor placement. Avoid
placing the sensor where shelving or other obstructions may block the sensors line of sight.
The FS-155/155-1 operates between 120-277VAC. It is designed for installation in a light fixture. The FS-155/155-1 sensor is equipped
with three, six-inch, 18AWG flying leads for connection to the lighting load and electrical system.
NOTE: There is an initial warm-up period. It may take up to a minute before the lights turn on due to a sensor warm-up period required
during initial power-up. This occurs during installation or after a lengthy power failure only.
INSTALLATION
1. Determine an appropriate mounting location inside the light fixture.
2. Cut a 9/16” diameter hole through the sheet metal in the bottom of
the fixture.
3. Remove the beauty ring and thumbscrew collar from the
FS-155/155-1 lens pipe.
4. Insert the lens through the hole in the bottom of the fixture then put the thumbscrew collar onto the lens pipe. Tighten it securely to
the outside of the fixture.
5. Use the holes or mounting slots at both ends of the sensor to secure it to the fixture.
6. Re-tighten the thumbscrew collar, then put the beauty ring onto the lens pipe and tighten it.
7. Connect load and supply wires as shown in Figure 2.
8. Restore power from the circuit breaker.
WARNING: TURN THE POWER OFF AT THE
CIRCUIT BREAKER BEFORE WIRING.
7LJKWHQ
)L[WXUH
:DOO
6HQVRU
Fig 1: FS-155/155-1 mounting in light xture
2
WIRING A SINGLE SENSOR
5HG±/RDG
%ODFN±+RW
:KLWH±1HXWUDO
/RDG
1HXWUDO
COVERAGE PATTERNS
FS-155
Density and range of the coverage pattern is determined by mount height. The FS-155 has a multi-cell, multi-tier Fresnel lens with a
view of 360°. This lens is designed to detect small motion when mounted within 6' of occupants. When mounted at a height of 8', the
coverage area is approximately 10' m diameter, but sensitivity may be diminished.
Coverage shown in the diagrams below is maximum. They represent coverage for full-step walking motion, with no barriers or obstacles.
FS-155-1
Density and range of the coverage pattern is determined by mounting height. The FS-155-1 has a multi-cell, multi-tier Fresnel lens
with a view of 360°. This lens is designed to detect motion when mounted within 10' of occupants. When mounted at a height of 8', the
coverage area is approximately 20' diameter.
Coverage shown in the diagrams below is maximum. They represent coverage for full-step walking motion, with no barriers or obstacles.
Fig 2: FS-155/155-1 wiring
(0m)
0ft
(0.6m)
2'
(0.3m)
1'
4'
(1.2m
)
5'
(1.5m)
0ft
(0m)
4'
(1.2m
)
5'
(1.5m)
2'
(0.6m
)
2'
(0.6m
)
(1.2m)
4'
(0.9m)
3'
(0.9m)
3'
(1.2m)
4'
(0.3m)
1'
(0.6m)
2'
(1.5m
)
5'
4'
(1.2m
)
6'
(1.8m)
8'
(2.4m
)
0’
(0m)
2'
(0.6m
)
(0m)
0'
(0.6m)
2'
(0.3m)
1'
(1.2m)
4'
(0.9m)
3'
(0.9m)
3'
(1.2m)
4'
(0.3m)
1'
(0.6m)
2'
(1.5m
)
5'
(1.5m)
5'
Fig 3: FS-155 coverage pattern,
top view from 8' mounting height
Fig 4: FS-155 coverage pattern, side view
(0m)
0'
(0m)
0'
(0.6m)
2'
(0.6m)
2'
(0.6m)
2'
(0.6m)
2'
(2.4m)
8'
(2.4m)
8'
(2.4m)
8'
(2.4m)
8'
(3m)
10'
(3m)
10'
(3m)
10'
(1.2m)
4'
(1.2m)
4'
(1.2m)
4'
(1.2m)
4'
(1.8m)
6'
(1.8m)
6'
(1.8m)
6'
(1.8m)
6'
5'
(1.5m)
8'
(2.4m)
0’
(0m)
(0m)
0'
(1.5m)
5'
(1.5m)
5'
2.5'
(0.8m)
(3m)
10'
(3m)
10'
Fig 5: FS-155-1 coverage pattern,
top view from 8' mounting height
Fig 6: FS-155-1 coverage pattern, side view
3
SENSOR ADJUSTMENT
The Time Delay adjustment potentiometer is on the top side of the FS-155/155-1. It may be necessary to adjust the sensor before the
fixture is fully assembled.
Test Occupancy Sensor
1. Turn the time delay to minimum.
2. Move out of the sensors view. Lights should turn OFF after 30 seconds.
3. Move into the detection area. Lights should turn ON.
Test and Adjust Time Delay
1. Adjust the time delay to minimum. Leave the area and let the sensor time out so lights are OFF.
2. Enter the space and lights should turn ON.
3. Set the time delay to the desired setting. The time delay can be set from 30 seconds to 30 minutes.
TROUBLESHOOTING
Lights will not turn on:
LED does not flash:
Check all wire connections and verify the ground wire is tightly secured.
LED does flash:
Check all wire connections and verify the load wire is tightly secured.
If lights still do not turn on, call 800.879.8585 for technical support.
Lights will not turn off:
The time delay can be set from 30 seconds to 30 minutes. Ensure that the time delay is set to the desired delay and that there is no
movement within the sensor’s view for that time period.
To quickly test the unit for proper operation, turn the time delay to minimum and move out of the sensor’s view. Lights should turn
off after 30 seconds.
If lights still do not turn off, call 800.879.8585 for technical support.
Operation during Power-Up
During the sensor warm-up period, which can last up to a minute after initial power-up (or after a lengthy power outage), the load can be
either on or off, depending on the status of the relay before the sensor was powered down. After warm-up, the sensor will open or close
the relay to correspond to the occupancy status of the room.
ORDERING INFORMATION
Catalog Number Description
FS-155 Fixture mount, line voltage occupancy sensor, 12' diam. coverage
FS-155-1 Fixture mount, line voltage occupancy sensor, 18' diam. coverage
All units are White.
CAUTION:
DO NOT OVERTURN TRIMPOT WHEN
ADJUSTING THE SENSOR.
800.879.8585
www.legrand.us/wattstopper
No. 24741 – 06/17 rev. 1
© Copyright 2017 Legrand All Rights Reserved.
© Copyright 2017 Tous droits réservés Legrand.
© Copyright 2017 Legrand Todos los derechos reservados.
Wattstopper warranties its products to be free
of defects in materials and workmanship for a
period of five (5) years. There are no obligations
or liabilities on the part of Wattstopper for
consequential damages arising out of, or in
connection with, the use or performance of this
product or other indirect damages with respect
to loss of property, revenue or profit, or cost of
removal, installation or reinstallation.
Wattstopper garantit que ses produits sont
exempts de défauts de matériaux et de fabrication
pour une période de cinq (5) ans. Wattstopper
ne peut être tenu responsable de tout dommage
consécutif causé par ou lié à l’utilisation ou
à la performance de ce produit ou tout autre
dommage indirect lié à la perte de propriété, de
revenus, ou de profits, ou aux coûts d’enlèvement,
d’installation ou de réinstallation.
Wattstopper garantiza que sus productos
están libres de defectos en materiales y mano
de obra por un período de cinco (5) años. No
existen obligaciones ni responsabilidades por
parte de Wattstopper por daños consecuentes
que se deriven o estén relacionados con el
uso o el rendimiento de este producto u otros
daños indirectos con respecto a la pérdida
de propiedad, renta o ganancias, o al costo
de extracción, instalación o reinstalación.
WARRANTY INFORMATION INFORMATIONS RELATIVES À LA GARANTIE INFORMACIÓN DE LA GARANTÍA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Legrand FS-155/155-1 Line Voltage Fixture Mount Occupancy Sensor Mode d'emploi

Taper
Mode d'emploi
Ce manuel convient également à