FS S5850-24XMG-U Mode d'emploi

Catégorie
Commutateurs réseau
Taper
Mode d'emploi
ETHERNET L3 SWITCHES
Ethernet L3-Switches
Switchs Ethernet L3
V1.0
Quick Start Guide
Quick Start Anleitung
Guide de Démarrage Rapide
S5850-24XMG-U
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
Introduction
EN
Thank you for choosing S5850-24XMG-U Series Switches. This guide is designed to familiarize you
with the layout of the S5850-24XMG-U Series Switches and describes how to deploy them in your
network.
Accessories
S5850-24XMG-U
S5850-24XMG-U
1
Rubber Pad x4
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 161 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
Console Cable x1
Front Mounting Bracket x2
Grounding Cable x1Power Cord x1
M4 Screw x12
Rear Mounting Bracket x2Sliding Rail x2
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
EN
Front Panel Ports
Ports Description
CON
USB
MGMT
POE RJ45
QSFP 28
A RJ45 console port for serial management
A USB management port for software configuration backup and offline
software upgrade
An out-of-band Ethernet management port
RJ45 ports for 10G connection
QSFP 28 ports for 100G connection
LEDs State
SYS
ID
Green
Orange
Blue
OFF
OFF
ON
ON
ON
The switch has loaded the agent software code and is
operating normally.
The system operating warning occurred.
The system operating or power supply failure occurred.
ID indication function is active.
ID indication function is not active.
Hardware Overview
S5850-24XMG-U
S5850-24XMG-U
2
RJ45 QSFP 28
MGMT
CON
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
RJ45 LED 100G Breakout
100G LED
SYS POE
MGMT
ID
Front Panel LEDs
Description
USB
EN
Back Panel
MGMT
POE
RJ45
100G LED
100G
Breakout
3
4 Hot-swappable Fans 2 Hot-swappable Power Supplies
Grounding Point
LEDs State
Green
OFF
OFF
OFF
OFF
OFF No link.
The port is linked on 100G/25G bandwidth.
The port is linked and there is data activity.
The port is linked on 40G/10G bandwidth.
The port is linked and there is data activity.
The port is linked off or has been split.
The breakout port is linked off or has been split.
The breakout port is linked and there is data activity.
The breakout port is linked to 10G/25G.
Link/Act
Green
(left)
Green
Orange
(right)
Yellow (ON)
ON
Green (ON)
Green
(Blinking)
Green
(ON)
Blinking
ON
Blinking
ON
Blinking
ON
Blinking
The port is linked on 100M/1000M.
The port is linked and there is data activity.
The port is linked off.
The remaining power of the PSE subsystem is less than
the alarm threshold.
The remaining power of the PSE subsystem is greater
than the alarm threshold.
The switch system is not started or the PSE subsystem is
not working properly.
The port is linked and the bandwidth could be 100M/
1G/2.5G/5G/10G.
The port is linked and there is data activity.
Description
EN
Phillips screwdriver.
Standard-sized, 19" wide rack with a minimum of 1U height available.
Category 5e or higher RJ-45 Ethernet cables for connecting network devices.
Installation Requirements
Before installation, make sure that you have the following conditions
ready:
1. Attach four rubber pads to the bottom of switch.
2. Place the switch on a desk.
Mounting the Switch
Site Environment:
Make sure that the temperature of installation site is maintained at 0°~50°.
Make sure that the relative humidity of installation site is maintained at 10%~90%.
The installation site must be free from leaking, dripping water, heavy dew or humidity.
Keep the installation site dust-free.
The installation site must be well ventilated. Ensure that there is adequate air flow around the
switch.
Make sure that the switch is level and stable to avoid any hazardous conditions.
Make sure that the rack and working platforms are well earthed.
Desk Mounting
4
SYS ID MGMT
CON
MGMT
S5850-24XMG
2
1
43
6
58
7
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
CON
MGMT
9 10 11 12
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
CON
MGMT
9 10 11 12 13 14
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
POE+
EN
Rack Mounting
1. Secure the mounting brackets to the two sides of the switch with eight M4 screws.
2. Attach the switch to the rack with four M6 screws and cage nuts.
5
1234
17 18 19 20 21 22 23 24
12 13 14 15 16
Breakout
26 100G
25
1234
17 18 19 20 21 22 23 24
15 16
Breakout
26 100G
25
CON
MGMT
9 10 11 12 13 14 15
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
EN
Rack Mounting-Single Switch Deployment
1. Fix the mounting bracket to the one side of the switch. And fix the rear mounting bracket to the
rack with two M4 screws.
2. Fix the sliding rail to the one side of switch with two M4 screws. And assemble the rear mounting
brackets as the following picture.
3. Front rack installing: Fix the front mounting brackets to the two sides of the switch with eight M4
screws.
4. Fix the switch to the rack with M6 screws and cage nuts.
6
1 2 3 4
17 18 19 20 21 22 23 24
14 15 16
Breakout
26 100G
25
EN
PWR1
PWR1
1. Take a new power module out of the package and confirm the input mode and the input
parameters of the power module match the requirements.
2. Remove the old power module and take the plane printed with power information as the top panel.
Hold the handle of the power module with one hand, and hold the end with the other hand.
3. Insert it into the power module slot along the guide rail uprightly and slowly until it totally inserts
into place (a click” sound is heard), then make sure that the module is in good contact with the slot.
EN
Installing the Power Supply Module
7
NOTE: 1. Insert the power module steadily.
2. Pay attention to the direction of insertion.
3. If the position is improper after inserting the power module, press the plug of the power
module and hold on to the handle with one hand to slowly pull it out, then re-insert it.
EN
1. Connect one end of the grounding cable to a proper earth ground, such as the rack in which the
switch is mounted.
2. Secure the grounding lug to the grounding point on the switch back panel with the washers and
screws.
EN
Grounding the Switch
8
CAUTION: The earth connection must not be removed unless all supply connections have
been disconnected.
1. Connect one end of an Ethernet cable to the RJ45 port.
2. Connect the other end of the Ethernet cable to another network device.
1. Plug the AC power cord into the power port on the back of the switch.
2. Connect the other end of the power cord to an AC power source.
EN
Connecting the Power
Connecting the RJ45 Ports
8
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
9
Connecting the SFP Ports
WARNING: Do not install power cords while the power is on.
SYS ID MGMT
CON
MGMT
S5850-24XMG
21
43
65 87
10
9
1. Plug the compatible QSFP28 optical module into the QSFP28 port.
2. Connect one end of a fiber optic cable to the optical module. Then connect the other end of the
cable to another fiber device.
EN
Connecting the QSFP 28 Port
10
Connecting the SFP Ports
WARNING: Laser beams will cause eye damage. Do not look into bores of optical modules
or fiber optical cables without eye protection.
10
12
11
14
13 16
15
18
17
20
19
22
21 24
23
123
26 100G
25
4Breakout
CON
MGMT
17 18 19 20 21
910 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
1. Insert the RJ45 connector of the console cable into the console port of the switch.
2. Connect the DB9 female connector of the console cable to the serial port of the computer.
1. Connect one end of a standard RJ45 Ethernet cable to the MGMT port of the switch.
2. Connect the other end of the cable to a computer.
EN
Connecting the CONSOLE Port
Connecting the MGMT Port
11
Connecting the Management Ports
SYS ID MGMT
CON
MGMT
21
43
65 87
10
9
12
11
14
13 16
15
18
17
20
19
22
21 24
23
POE+
S5850-24XMG-U
1 2 3 4
21 22 23 24
Breakout
26 100G
25
Insert the Universal Serial Bus (USB) flash disk to the USB port for software and configuration backup
and offline software upgrade.
EN
Connecting the USB Port
12
123
26
25
4Breakout
CON
MGMT
17 18 19 20
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
USB
EN
13
1 2 3 4
20 21 22 23 24
Breakout
26 100G
25
Configuring the Switch
Configuring the Switch via the Web-based Interface
Step 1: Connect your computer to the Management port of the Switch using the network cable.
Step 2: Set the IP address of the computer to 192.168.1.x ("x" is any number from 2 to 254).
Step 3: Open a browser, type http://192.168.1.1, and enter the default username and password
admin/admin.
?x
OK Cancel
General
IP address:
Subnet mask:
Default gateway:
You can get IP settings assigned automatically if your network
supports this capability. Otherwise, you need to ask your network
administrator for the appropriate IP settings.
Internet Protocol Version 4 (TCP/IPv4) Properties
Use the following IP address:
Obtain an IP address automatically
Preferred DNS server:
Alternate DNS server:
Validate settings upon exit Advanced...
. . . 21168192
0255
255255
. . .
. . .
. . .
. . .
Obtain DNS server address automatically
Use the following DNS server addresses:
IE 8/9/10/11, Google Chrome, Firefox are supported
Login
admin
*****
Step 4: Click Login to display the web-based configuration page.
EN
14
Configuring the Switch via the Console Port
Step 1: Connect a computer to the switch's console port using the console cable.
Step 2: Start the terminal simulation software such as HyperTerminal on the computer.
Step 3: Set the parameters of the HyperTerminal: 9600 bits per second, 8 data bits, no parity, 1 stop bit
and no flow control.
Step 4: After setting the parameters, click Connect to enter.
x
Quick Connect
Protocol:
The port may be manually entered or selected from the list.
Serial
Flow Control
DTR/DSR
RTS/CTS
XON/XOFF
Save sessionShow quick connect on startup
Open in a tab
Connect Cancel
COM3
115200
8
None
1
Port:
Baud rate:
Data bits:
Parity:
Stop bits:
Name of pipe:
EN
15
Troubleshooting
The Power Module Cannot Supply Power
All LEDs on the front panel, the fan module and the panel of the power module are off. The fan does
not work. First disconnect the power cord of the power module, then check the following:
1. Check whether the cable connections of the rack are correct.
2. Check whether the connection between the power socket and the power cord is loose.
3. Check whether the connection between the power module and the power cord is loose.
4. Check whether the power module inserts into place.
1. Test network connectivity through ping.
2. If the network is reachable, try restarting the switch.
3. Check whether the corresponding service enables.
1. Check whether the console cable is correctly connected.
2. Check whether the console cable is broken.
3. Check whether the console port of the switch is the same as the port of the terminal device.
4. Check whether the console port configuration of the terminal device is correct.
Connecting the Switch Remotely Unsuccessfully
1. Check whether the receiving and delivering of fiber optical cable connects correctly.
2. Check whether the wavelengths of optical modules of the interconnection are the same.
3. Check whether the distance of the interconnection is within the distance marked by the optical
module.
4. Check whether the rates of the interconnection are the same or whether the mode of port rate is
configured correctly for ports which support different rates.
5. Check whether the optical fiber type meets the requirements.
The Optical Port Cannot Link up
No Characters/Distorted Characters are Displayed on the Screen of the
Terminal Device
EN
FS ensures our customers that any damage or faulty items due to our workmanship, we will offer a
free return within 30 Days from the day you receive your goods. This excludes any custom-made
items or tailored solutions.
Return: If you want to return item(s), information on how to return can be found at
https://www.fs.com/policies/day_return_policy.html
Warranty: S5850-24XMG-U Series enjoy a 5-year limited warranty against defect in
materials or workmanship. For more details about warranty, please check at
https://www.fs.com/policies/warranty.html
5
Product Warranty
16
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
DE
17
Einführung
Vielen Dank, dass Sie sich für Switches der Serie S5850-24XMG-U entschieden haben. Diese Anleitung
soll Sie mit dem Layout der S5850-24XMG-U Serie Switches vertraut machen und beschreibt, wie Sie
diese in Ihrem Netzwerk einsetzen können.
Zubehör
S5850-24XMG-U
S5850-24XMG-U
Gummipad x4
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 249 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
Konsolenkabel x1
Vordere
Montagehalterung x2
Erdungskabel x1Netzkabel x1
M4-Schraube x12
Hintere
Montagehalterung x2
Schiebeschiene x2
DE
18
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
Ports an der Vorderseite
Port Beschreibung
CON
USB
MGMT
POE RJ45
QSFP 28
Ein RJ45-Console-Port für die serielle Verwaltung
Ein USB-Verwaltungsport für die Sicherung der Softwarekonfiguration und
die Offline-Aktualisierung der Software
Ein Out-of-Band-Ethernet-Management-Port
RJ45-Ports für 10G-Verbindung
QSFP28 Ports für 100G-Verbindung
LED Status
SYS
ID
Grün
Orange
Blau
AUS
AUS
AN
AN
AN
Der Switch hat den Softwarecode des Agenten geladen und
arbeitet normal.
Die Systembetriebswarnung wird angezeigt.
Das Betriebssystem oder die Stromversorgung ist ausgefallen.
Die ID-Anzeigefunktion ist aktiv.
Die ID-Anzeigefunktion ist nicht aktiv.
Hardware-Übersicht
S5850-24XMG-U
S5850-24XMG-U
RJ45 QSFP 28
MGMT
CON
CON
MGMT
1 2 3 4
17 18 19 20 21 22 23 24
9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8
SYS ID MGMT POE
S5850-24XMG-U POE+
Breakout
26 100G
25
RJ45 LED 100G Breakout
100G LED
SYS POE
MGMT
ID
LEDs an der Vorderseite
Beschreibung
USB
DE
19
Rückseite
4 Hot-swap-fähige Lüfter 2 Hot-swap-fähige Netzteile
Erdungspunkt
MGMT
POE
RJ45
100G LED
100G
Breakout
LED Status
Grün
AUS
AUS
AUS
AUS
AUS Kein Verbindung.
Der Port ist mit einer 100G/25G-Bandbreite verbunden.
Der Port ist verbunden und es gibt Datenaktivität.
Der Port ist mit einer Bandbreite von 40G/10G verbunden.
Der Port ist verbunden und es gibt Datenaktivität.
Der Anschluss ist nicht verbunden oder wurde geteilt.
Der Breakout-Port ist nicht angeschlossen oder wurde geteilt.
Der Breakout-Port ist verbunden und es gibt Datenaktivität.
Der Breakout-Port ist mit 10G/25G verbunden.
Link/Act
Grün
(links)
Grün
Orange
(rechts)
Gelb (AN)
AN
Grün (AN)
Grün
(Blinkt)
Grün
(AN)
Blinkt
AN
Blinkt
AN
Blinkt
AN
Blinkt
Der Port ist mit 100M/1000M verbunden.
Der Port ist verbunden und es gibt Datenaktivität.
Der Port ist nicht verbunden.
Die verbleibende Leistung des PSE-Teilsystems liegt
unter der Alarmschwelle.
Die verbleibende Leistung des PSE-Teilsystems ist
größer als die Alarmschwelle.
Das Switch-System ist nicht eingeschaltet oder das
PSE-Subsystem arbeitet nicht ordnungsgemäß.
The port is linked and the bandwidth could be 100M/
1G/2.5G/5G/10G.
Der Port ist verbunden und die Bandbreite kann
100M/1G/2,5G/5G/10G betragen.
Beschreibung
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52

FS S5850-24XMG-U Mode d'emploi

Catégorie
Commutateurs réseau
Taper
Mode d'emploi

dans d''autres langues