HARDWARE
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
INSTALLATION INSTRUCTION
667 - LED Outdoor
WS-66734
Wire Connector
Qty: 5 pcs + 1 Extra
Junction Box Screw
Qty: 2 pcs + 1 Extra
#8-32x5/8 SS
Mounting Screw
Qty: 1 Extra
5/32-32x5/16
Nickel Plating
Screw
Qty: 2 pcs + 1 Extra
5/32-32x5/16
Nickel Plating
A1 B1 C1 D1
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Remove the mounting screws (C1) from the mounting back plate.
4. Connect the Driver’s input wires to junction box wires as shown in Fig. 2, making sure that all wire connectors (A1) are secured.
If your outlet box has a green or bare copper ground wire, connect the xture’s
ground wire to it. Otherwise, connect the xture’s ground wire directly to the
back plate using the green screw provided. After wires are connected, tuck
them carefully inside the junction box.
*Requires Driver to be recessed within the junction box.
COMPLETING THE INSTALLATION (Fig. 1)
5. Secure the mounting back plate to the junction box using junction box
screws (B1). The side of the mounting back plate marked “GND” must face out.
6. Insert the crystal onto the xture, and then secure it with screw (D1).
7. Place the xture over the mounting back plate and secure it with mounting
screws (C1).
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 2 Wiring
Mounting Screw
Crystal
(RPL-GLA-66734-01)
Screw
Wire Connector
Junction Box Screw
White Wire
Black Wire
Junction Box
Ground Wire
Driver
Mounting Back Plate
Black Wire
Red Wire
C1
D1
A1
B1
FIG. 1
INSTALLATION INSTRUCTION
667 - LED Outdoor
WS-66734
Back Plate Dimensions
4"
1 3/4"
1 3/8"
5 3/8"
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
INSTALLATION INSTRUCTION
Elessar - LED Wall Sconce
WS-66641
HARDWARE HDW66641ELESSAR
A1 B1 C1 D1 E1 F1 G1 H1 J1
Wire
Connector
Qty: 2 pcs
+ 1 Extra
Junction
Box Screw
Qty: 2 pcs
+ 1 Extra
Mounting
Screw
Qty: 1 Extra
Anchor
Qty: 1 pc
+ 1 Extra
Wood
Screw
Qty: 1 pc
1 Extra
Allen
Wrench
Qty: 1 pc
Allen
Screw
Qty: 1 pc
+ 1 Extra
Iron
Studs
Qty: 1 pc
Screw
Qty: 2 pcs
+ 1 Extra
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are
worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté
et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du
luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta lación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali mentación
principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
PREPARATION
1. Shut o the power at the circuit breaker and remove existing
xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on
a clear area. Be careful not to lose any small parts necessary
for installation.
CONNECTING THE WIRES Fig. 2
3. Remove the mounting screw (C1) from the xture.
4. Connect the driver input wires with junction box wires as
shown in Fig. 2, making sure that all wire connectors (A1)
are secured. If your outlet box has a green or bare copper
ground wire, connect the xture’s ground wire to it.
Otherwise, connect the xture’s ground wire directly to the
mounting plate using the green screw provided. After wires
are connected, tuck them carefully inside the junction box.
*Require Driver to be recessed within the junction box.
MOUNTING THE FIXTURE Fig. 1
5. Secure mounting plate to the junction box using junction
box screws (B1), the side of the mounting plate marked “GND”
must face out.
6. Drill a hole in the wall aligned with the screw tube located on
the xture tail, insert the plastic anchor (D1), fasten the wood
screw (E1) and the iron studs (H1) to the plastic anchor.
7. Insert the crystal onto the xture, secure it with screw (J1).
8. Place the xture over the mounting back plate and secure it
with mounting screws (C1).
9. Insert the screw tube to the iron studs, fasten it with
Allen screw (G1) using the Allen Wrench (F1).
C1
A1
B1
E1
H1
D1
G1
F1
J1
Mounting Screw
Wire Connector
Junction Box Screw
Wood Screw
Iron Studs
Plastic Anchor
Allen Screw
Allen Wrench
Screw Tube
4”
5 1/2”
Fixture
Driver
Mounting Backplate
Junction
Box
Ground Wire
Screw
Red Wire
Black Wire
White Wire
Black Wire
FIG.1
Back Plate Dimensions
3 1/2”
INSTALLATION INSTRUCTION
Elessar - LED Wall Sconce
WS-66641
Fixture Wires
Brown
Fixture Wires
Blue
Fixture Wires
Yellow Green
House Wires
Hot
House Wires
Neutral
House Wires
Ground Wire
Fig. 2 Wiring