Leonton EG5-0702-SFP Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur
LEONTON
EG5-0702-SFP Series
(EG5-0702-SFP / EG5-0702-SFP-T)
User Manual
© Copyright 2020 Leonton Technologies Co., Ltd.
All Rights Reserved
This document contains information, which is protected by copyright. Reproduction, adaptation or
translation without prior permission is prohibited, except as allowed under the copyright laws.
Disclaimer
Leonton Technologies, Co. Ltd. provides this manual without warranty of any kind, expressed or
implied, including but not limited to the implied warranties of merchantability and fitness for a
particular purpose. Leonton Technologies, Co. Ltd. may make improvements and/or changes to
the product and/or specifications of the product described in this manual, without prior notice.
Leonton Technologies, Co. Ltd. will not be liable for any technical inaccuracies or typographical
errors found in this guide. Changes are periodically made to the information contained herein and
will be incorporated into later versions of the manual. The information contained is subject to
change without prior notice.
FCC Notice
This equipment has been tested and found to comply with the limits for a Class-A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy. It may cause harmful interference to radio communications if the
equipment is not installed and used in accordance with the instructions. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications not expressly approved by the grantee of this device could
void the user's authority to operate the equipment.
Déclaration FCC
Cet équipement a été testé et reconnu conforme aux limites de la classe A pour les équipements
numériques, conformément à la section 15 des Réglementations FCC. Ces limites sont conçues pour
fournir une protection raisonnable contre toutes interférences nuisibles dans un milieu résidentiel.
Cet équipement génère, utilise, et peut émettre de l’énergie de fréquence radio et, s’il n’est pas
installé et utilisé conformément au manuel d’instruction, peut perturber la réception radio.
Cependant, il n’est pas garanti que l’équipement ne produira aucune interférence dans une
installation particulière. Si cet équipement cause des interférences nuisibles à la réception radio ou
télévisée, qui peuvent être déterminées en l’éteignant et le rallumant, l’utilisateur est encouragé à
essayer de remédier au problème en prenant les mesures suivantes:
* Réorienter ou déplacer l’antenne réceptrice.
* Augmenter la distance entre l’équipement et le récepteur.
* Connecter léquipement à une prise secteur sur un circuit différent de celui utilisé par le récepteur.
* Consulter le négociant ou un technicien radio/TV expérimenté.
Caution: Any changes or modifications not expressly approved by the grantee of this device could
void the user's authority to operate the equipment.
Attention: Tout changement ou modification non expressément approuvé par le concessionnaire de
cet appareil pourrait annuler l'autorité de l'utilisateur à utiliser l'équipement.
CE Mark Warning
This is a Class-A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
CE Mark Avertissement
Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut être utilisé en
présence d'interférences radio.
This document is the current official release manual. Please check our website (www.leonton.com)
for any updated manual or contact us by e-mail (sales@leonton.com).
Contents
Overview .............................................................................................................................................................................................. 1
Key Features ............................................................................................................................................................................. 1
Package Contents................................................................................................................................................................... 2
Safety Precaution ................................................................................................................................................................... 2
Hardware Description ..................................................................................................................................................................... 3
Physical Dimensions .............................................................................................................................................................. 3
Front Panel ................................................................................................................................................................................ 4
Top View ..................................................................................................................................................................................... 4
LED Indicators .......................................................................................................................................................................... 5
Ethernet Ports .......................................................................................................................................................................... 6
Cabling ....................................................................................................................................................................................... 7
Wiring the Power Inputs ...................................................................................................................................................... 9
Wiring the Fault Alarm Contact ...................................................................................................................................... 10
Mounting Installation ................................................................................................................................................................... 11
DIN-Rail Mounting .............................................................................................................................................................. 11
Wall Mounting - in the industrial control panel....................................................................................................... 13
Hardware Installation .................................................................................................................................................................... 14
Installation Steps .................................................................................................................................................................. 14
Maintenance and Service ............................................................................................................................................................ 15
Trouble Shooting ............................................................................................................................................................................ 16
1
Overview
This series is rated IP30 and installation by DIN Rail. Each unit of this industrial gigabit managed
Ethernet switch series has 5*10/100/1000TX and 2 dual-rate (100/1000) SFP slots, suitable for
applications that require high bandwidth and long distance communication.
In order to prevent unregulated voltage, this series provides high EFT and ESD protection. This
also allows it to function in harsh environments, as well as support power redundancy with a dual
power input design with reverse polarity protection. The built-in relay warning function alerts
users about occurring power failures.
With one model having an operating temperature of -10 to 65°C, and another with a wide
operating temperature of -40 to 75°C, this series is designed to meet any needs for industrial
automation, outdoor application and harsh environments.
Key Features
Interface & Performance
All Copper ports support auto MDI/MDI-X function
Embedded 5*10/100/1000Tx and 2*100/1000 SFP Slot
Store-and-forward switching architecture
8K MAC Address Table
Supports 9.6Kbytes Jumbo Frame
4Mbits memory buffer
Power Input
EG5-0702-SFP: Dual 12-48VDC redundant power inputs, with SELV output certified by
UL61010-2-201
1 removable 6-contact terminal block
Max. current 1A
Certification
CE/FCC
UL 61010-1
UL 61010-2-201
Operating Temperature
Standard operating temperature model: -10°C ~ 65°C
Extended operating temperature model (T): -40°C ~ 75°C
Case/Installation
IP-30 protection (not certified by UL)
Installation in a pollution degree to environment
DIN-Rail and wall mount design
indoor use
Pollution degree 2
2
Package Contents
1 - EG5-0702-SFP(-T) product
2 - Wall mounting brackets and screws
1 - Quick installation guide
1 - RJ45 to DB9 Serial Console cable
Safety Precaution
Attention
If the DC voltage is supplied by an external circuit, please use a protection device on the power
supply input. The industrial Ethernet switch’s hardware specs, ports, cabling information, and wiring
installation will be described within this user manual.
Attention
Si la tension CC est fournie par un circuit externe, veuillez utiliser un dispositif de protection sur
l'entrée d'alimentation. Fourniture par courant industriel homologué UL. Les spécifications
matérielles, les ports, les informations de câblage et l'installation du câblage du convertisseur de
média industriel seront décrits dans ce manuel d'utilisation.
3
Hardware Description
Physical Dimensions
Figure 2.1, below, shows the physical dimensions of EG5-0702-SFP series.
(W x D x H) is 54mm x 99mm x 142mm
Figure 2.1: EG5-0702-SFP series Physical Dimensions
4
Front Panel
The front panel of the EG5-0702-SFP series industrial Gigabit managed Ethernet switch is
shown below in Figure 2.2.
Figure 2.2: The Front Panel of EG5-0702-SFP series
Top View
Figure 2.3, below, shows the top panel of the EG5-0702-SFP series switch that is equipped with
one 6-pin removal terminal block connector for dual DC power inputs (12~48VDC).
Figure 2.3: Top Panel View of EG5-0702-SFP series
5
LED Indicators
There are LED light indicators located on the front panel of the industrial Ethernet switch that
display the power status and network status. Each LED indicator has a different color and has
its own specific meaning, see below in Table 2.1.
LED Color Description
P1 Green
On Power input 1 is active
Off Power input 1 is inactive
P2 Green
On Power input 2 is active
Off Power input 2 is inactive
FAULT
Green On No event happened
Red Off 1. Power input 1 or 2 is inactive
2. Port link-down/Broken
MASTER Green
On ERPS Owner Mode (Ring Master) is ready
Off ERPS Owner Mode is not active
RING Green
On ERPS Ring Network is active and works well
Flashing ERPS Ring works abnormally or misconfigure
Off ERPS Ring Network is not active
L/A
(SFP Port 6-7)
Green:
1000Mbps
Amber:
100Mbps
On Connected to network, 100/1000Mbps
Flashing Networking is active
Off Not connected to network
1G
(LAN Port 1-5)
Green
On Connected to network, 1000Mbps
Flashing Networking is active
Off Not connected to network
10/100
(LAN Port 1-5)
Green
On Connected to network, 10/100Mbps
Flashing Networking is active
Off Not connected to network
Table 2.1: LED Indictors for EG5-0702-SFP series
6
Ethernet Ports
RJ-45 Ports (Auto MDI/MDIX)
The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX or
1000Base-T devices connections. Auto MDI/MDIX means that the
switch can connect to another switch or workstation without
changing the straight-through or crossover cabling. See the figures
as below for straight-through and crossover cabling schematics.
10/100BASE-T(X) RJ-45 Pin Assignments (Table 2.2)
Crossover Cable Straight Through Cable
Pin Number / Signal Pin Number / Signal Pin Number / Signal Pin Number / Signal
1 / RX+ 3 / TX+ 1 / RX+ 1 / TX+
2 / RX- 6 / TX- 2 / RX- 2 / TX-
3 / TX+ 1 / RX+ 3 / TX+ 3 / RX+
6 / TX- 2 / RX- 6 / TX- 6 / RX-
Table 2.2
1000BASE-T RJ-45 Pin Assignments (Table 2.3)
Crossover Cable Straight Through Cable
Pin Number / Signal Pin Number / Signal Pin Number / Signal Pin Number / Signal
1 / TP0+ 3 / TP1+ 1 / TP0+ 1 / TP1+
2 / TP0- 6 / TP1- 2 / TP0- 2 / TP1-
3 / TP1+ 1 / TP0+ 3 / TP1+ 3 / TP0+
4 / TP2+ 7 / TP3+ 4 / TP2+ 4 / TP3+
5 / TP2- 8 / TP3- 5 / TP2- 5 / TP3-
6 / TP1- 2 / TP0- 6 / TP1- 6 / TP0-
7 / TP3+ 4 / TP2+ 7 / TP3+ 7 / TP2+
8 / TP3- 5 / TP2- 8 / TP3- 8 / TP2-
Table 2.3
Note: “+” and “- signs represent the polarity of the wires that make up each wire pair.
7
Cabling
Use the four twisted-pair, category 5e, or the above cabling for RJ-45 port connections. The cable
between the switch and the link partner (switch, hub, workstation, etc.) must be less than 100
meters (328 ft.) long.
The small form-factor pluggable (SFP) is a compact optical transceiver used in optical
communications for both telecommunication and data communication applications.
Caution: Please employ optional optical transceiver (SFP/Fixed Fiber) that complies with IEC
60825-1 and classified as Class 1 laser product.
Attention: Veuillez utiliser un émetteur-récepteur optique (SFP) conforme à la norme CEI 60825-1
et classé comme produit laser de classe 1.
To connect the transceiver and LC cable, please follow below steps:
Step 1 Insert the SFP transceiver module into the SFP slot as shown below in Figure 2.4. Notice
that the triangle mark is at the bottom of the SFP slot. Figure 2.5 shows SFP transceiver
module was inserted.
Figure 2.4: Transceiver to the SFP Module
Figure 2.5: Transceiver Inserted
Step 2 Insert the fiber cable of the LC connector into the transceiver as shown below in Figure
2.6.
8
Figure 2.6: LC Connector to the Transceiver
To remove the LC connector from the transceiver, please follow the steps shown below:
Step 1 Press the upper side of the LC connector from the transceiver and pull it out to release
as shown below in Figure 2.7
Figure 2.7: Remove LC Connector
Step 2 Push down the metal clasp and pull the transceiver out by the plastic part as shown
below in Figure 2.8
Figure 2.8: Pull Out from the SFP Module
9
Wiring the Power Inputs
Caution: Please follow the below steps to insert the power wire.
Attention: Veuillez suivre les étapes ci-dessous pour insérer le câble d'alimentation.
Step 1 Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.9.
Figure 2.9: Power Terminal Block
Step 2 Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure 2.10.
Figure 2.10: Power Terminal Block
Caution: Only use copper conductors, 125°C, tighten to 5 in-lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Attention: Utilisez uniquement des conducteurs en cuivre, 125°C, serrez à 5 in-lbs (0.56 Nm). Le
calibre du bornier doit être compris entre 18 et 20 AWG.
10
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of the terminal block connector as the picture shows
below in Figure 2.11. By inserting the wires, it will detect the fault status including power
failure or port link failure (managed industrial switch only) and form a normally open circuit.
An application example for the fault alarm contact is shown below in Figure 2.11.
Figure 2.11: Wiring the Fault Alarm Contact
Caution: The wire gauge for the terminal block should range between 12 ~ 24 AWG.
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault
alarm.
Attention: Le calibre des fils du bornier doit être compris entre 12 et 24 AWG.
Si vous n'utilisez qu'une seule source d'alimentation, jumelez les broches 1 à 5 et les broches 2 à 6
pour éliminer l'alarme de panne de courant.
11
Mounting Installation
DIN-Rail Mounting
The DIN-Rail is pre-installed on the industrial Ethernet switch from the factory. If the DIN-Rail is
not on the industrial Ethernet switch, please see Figure 3.1 to learn how to install the DIN-Rail
on the switch.
Figure 3.1: The Rear Side of the Switch and DIN-Rail Bracket
Follow the steps below to learn how to hang the industrial Ethernet switch.
Step 1 Use the screws to install the DIN-Rail bracket on the rear side of the industrial
Ethernet switch.
Step 2 To remove the DIN-Rail bracket, do the opposite from Step 1.
Step 3 After the DIN-Rail bracket is installed on the rear side of the switch, insert the top of
the DIN-Rail on to the track as shown below in Figure 3.2.
12
Figure 3.2: Insert the Switch on the DIN-Rail
Step 4 Lightly pull down the bracket on to the rail as shown below in Figure 3.3.
Figure 3.3: Stable the Switch on DIN-Rail
Step 5 Check if the bracket is mounted tightly on the rail.
Step 6 To remove the industrial Ethernet switch from the rail, do the opposite from the
above steps.
13
Wall Mounting - in the industrial control panel
Follow the steps below to mount the industrial Ethernet switch using the wall mounting
bracket as shown below in Figure 3.4.
Step 1 Remove the DIN-Rail bracket from the industrial Ethernet switch by loosening the
screws.
Step 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet
switch.
Step 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch.
Step 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial
Ethernet switch on the wall.
Step 5 To remove the wall mount bracket, do the opposite from the steps above.
Figure 3.4: Remove DIN-Rail Bracket from the Switch and Install the Wall Mount Bracket
Below, in Figure 3.5 are the dimensions of the wall mounting bracket.
Figure 3.5: Wall Mounting Bracket Dimensions
14
Hardware Installation
Installation Steps
This section will explain how to install EG5-0702-SFP series.
Installation Steps
Step 1. Unpack the industrial Media Converter from the original packing box.
Step 2. Check if the DIN-Rail bracket is screwed on the industrial Media Converter.
If the DIN-Rail is not screwed on the industrial Media Converter, please refer to the DIN-Rail
Mounting section for DIN-Rail installation.
If you want to wall mount the industrial Media Converter, please refer to the Wall Mounting
section for wall mounting installation.
Step 3. To hang the industrial Media Converter on a DIN-Rail or wall, please refer to the Mounting
Installation section.
Step 4. Power on the industrial Media Converter and then the power LED light will turn on.
If you need help on how to wire power, please refer to the Wiring the Power Inputs section.
Please refer to the LED Indicators section for LED light indication.
Step 5. Prepare the twisted-pair, straight-through category 5 cable for Ethernet connection.
Step 6. Insert one side of the RJ-45 cable into Media Converters Ethernet port and on the other
side into the networking device’s Ethernet port, e.g. switch PC or server. The Ethernet
ports (RJ-45) LED on the industrial Media Converter will turn on when the cable is
connected to the networking device.
Please refer to the LED Indicators section for LED light indication.
Step 7. Insert one side of the SFP cable into Media Converter’s SFP port and on the other side into
the networking device’s SFP port, e.g. switch or server. The SFP port’s LED on the
industrial Media Converter will turn on when the cable is connected to the networking
device.
Please refer to the LED Indicators section for LED light indication.
Step 8. When all connections are set and the LED lights all show normal, the installation is
complete.
15
Maintenance and Service
If the device requires servicing of any kind, the user is required to disconnect and remove it
from its mounting. The initial installation should be done in a way that makes this as
convenient as possible.
Voltage/Power lines should be properly insulated as well as other cables. Be careful when
handling them so as to not trip over.
Do not under any circumstance insert foreign objects of any kind into the heat dissipation
holes located in the different faces of the device. This may not only harm the internal layout,
but might cause harm to user as well.
Do not under any circumstance open the device for any reason. Please contact your dealer for
any repair needed or follow the instructions within the manual.
Clean the device with dry soft cloth.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21