IMC Networks IE-Giga-MiniMc Mode d'emploi

Catégorie
Convertisseurs de média réseau
Taper
Mode d'emploi
9
19772 Pauling • Foothill Ranch, CA 92610-2611 USA
TEL: (949) 465-3000 • FAX: (949) 465-3020
www.imcnetworks.com
© 2006 IMC Networks. All rights reserved.
The information in this document is subject to change without notice. IMC Networks assumes no responsibility for any
errors that may appear in this document. IE-Giga-MiniMc is a trademark of IMC Networks. Other brands or product
names may be trademarks and are the property of their respective companies.
Document Number 56-80830-00 A1 June 2007
If the product’s part number begins with an “8”, it is compliant with the Restriction of Hazardous Substances (RoHS)
directive.
i
IE-Giga-MiniMc
Operation Manual
ii
FCC RADIO FREQUENCY INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which the user will be required to correct the interference at his own expense.
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The use of non-shielded I/O cables may not guarantee compliance with FCC RFI limits. This digital apparatus does not exceed the Class B
limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe B
prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada.
WARRANTY
IMC Networks warrants to the original end-user purchaser that this product, EXCLUSIVE OF SOFTWARE, shall be free
from defects in materials and workmanship under normal and proper use in accordance with IMC Networks' instructions
and directions for a period of six (6) years after the original date of purchase. This warranty is subject to the limitations set
forth below.
At its option, IMC Networks will repair or replace at no charge the product which proves to be defective within such
warranty period. This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable
use, accident, negligence, service or modification by anyone other than an authorized IMC Networks Service Technician
or by any other causes unrelated to defective materials or workmanship. Any replaced or repaired products or parts carry
a ninety (90) day warranty or the remainder of the initial warranty period, whichever is longer.
To receive in-warranty service, the defective product must be received at IMC Networks no later than the end of the
warranty period. The product must be accompanied by proof of purchase, satisfactory to IMC Networks, denoting
product serial number and purchase date, a written description of the defect and a Return Merchandise Authorization
(RMA) number issued by IMC Networks. No products will be accepted by IMC Networks which do not have an RMA
number. For an RMA number, contact IMC Networks at PHONE: (800) 624-1070 (in the U.S. and Canada) or (949) 465-
3000 or FAX: (949) 465-3020. The end-user shall return the defective product to IMC Networks, freight, customs and
handling charges prepaid. End-user agrees to accept all liability for loss of or damages to the returned product during
shipment. IMC Networks shall repair or replace the returned product, at its option, and return the repaired or new
product to the end-user, freight prepaid, via method to be determined by IMC Networks. IMC Networks shall not be
liable for any costs of procurement of substitute goods, loss of profits, or any incidental, consequential, and/or special
damages of any kind resulting from a breach of any applicable express or implied warranty, breach of any obligation
arising from breach of warranty, or otherwise with respect to the manufacture and sale of any IMC Networks product,
whether or not IMC Networks has been advised of the possibility of such loss or damage.
EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE, IMC NETWORKS MAKES NO OTHER WARRANTIES,
WHETHER EXPRESS OR IMPLIED, WITH RESPECT TO THIS IMC NETWORKS PRODUCT, INCLUDING WITHOUT
LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED. IMC NETWORKS SHALL DISREGARD AND NOT BE
BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON, INCLUDING EMPLOYEES,
DISTRIBUTORS, RESELLERS OR DEALERS OF IMC NETWORKS, WHICH ARE
INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE. ALL IMPLIED WARRANTIES INCLUDING THOSE OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY LIMITED TO THE DURATION OF THE
EXPRESS WARRANTY STATED ABOVE.
Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials
accurately describe IMC Networks product specifications and capabilities at the time of publication. However, because of
ongoing improvements and updating of IMC Networks products, IMC Networks cannot guarantee the accuracy of printed
materials after the date of publication and disclaims liability for changes, errors or omissions.
8
SAFETY CERTIFICATIONS
UL/CUL: Listed to Safety of Information Technology Equipment, including
Electrical Business Equipment.
CE: The products described herein comply with the Council Directive on
Electromagnetic Compatibility (89/336/EEC) and the Council Directive
on Electrical Equipment Designed for use within Certain Voltage Limits
(73/23/EEC). Certified to Safety of Information Technology Equipment,
Including Electrical Business Equipment. For further details, contact
IMC Networks.
European Directive 2002/96/EC (WEEE) requires that any equipment that bears this
symbol on product or packaging must not be disposed of with unsorted municipal
waste. This symbol indicates that the equipment should be disposed of separately
from regular household waste. It is the consumer’s responsibility to dispose of this
and all equipment so marked through designated collection facilities appointed by
government or local authorities. Following these steps through proper disposal and
recycling will help prevent potential negative consequences to the environment and
human health. For more detailed information about proper disposal, please contact
local authorities, waste disposal services, or the point of purchase for this equipment.
7
SPECIFICATIONS
Fiber Connections:
Multi-mode 1300nm Dual Fiber
Single-mode 1310nm 1550nm Dual Fiber
Single-mode 1310nm 1550nm Single-Strand Fiber
Ethernet Connections:
10/100/1000 BaseT
Auto-Negotiation
Auto-Cross
Flow Control
1632 MTU
Full Line-Rate Forwarding
DC Input Voltage:
7 to 50 VDC on DC terminal block
5 VDC on DC jack
AC Wall Adapter:
100 to 240 ±10% VAC input, 5 VDC output, 2 A max.
Power Consumtion
600 mA
Operating Temperature:
-31° to 158° F (-35° to 70° C) DC terminal block
32° to 122° F (0° to 50° C) with IMC supplied AC wall adapter
Storage Temperature:
-31° to 167° F (-35° to 75° C)
Humidity:
5 to 90% (non-condensing); 0 to 10,000 ft. altitude
Dimensions:
0.83”H x 1.80”W x 3.35”D (2.11 x 4.57 x 8.51 cm)
iii
TABLE OF CONTENTS
FCC Radio Frequency Interference Statement ....................................................ii
Warranty............................................................................................................ii
Introduction to the IE-Giga-MiniMc....................................................................1
Installing the IE-Giga-MiniMc .............................................................................2
Powering the IE-Giga-MiniMc ............................................................................3
DC Power Supply Precautions............................................................................5
Operating the IE-Giga-MiniMc ...........................................................................5
Reading the LEDs...............................................................................................6
IMC Networks Technical Support.......................................................................6
Specifications .....................................................................................................7
Safety Certifications............................................................................................8
1
INTRODUCTION TO THE IE-GIGA-MINIMC
The IE-Giga-MiniMc
TM
is a 10/100/1000 auto-negotiating switching miniature media
converter. The fiber port always operates at 1000 Mbps Full Duplex [FDX]; the
copper port auto-negotiates the connected device’s speed and duplex mode: 10/100
Mbps Half Duplex [HDX]; or 10 /100/1000 Mbps Full Duplex [FDX] (including Flow
Control).
The “IE” represents the unit’s use as an Industrial Ethernet device, which allows for
extended temperature operation of -35° to 70° C (0°C to 50°C when using the
included AC adapter).
The IE-Giga-MiniMc converter offers plug-and-play operation, including the
AutoCross feature which automatically selects between a crossover work-station or
straight-through repeater hub connection depending on the connected device.
The IE-Giga-MiniMc can use either the included IMC Networks universal, external
power adapter with 100 to 240 ±10% VAC input or can be wired directly to the 7-
50 VDC terminal block (for extended temperature configuration).
6
READING THE LEDS
Each Giga-MiniMc converter includes two LEDs, located on the RJ-45 connector.
LED functions are as follows:
FX LNK/ACT
: Glows green when a link is established on the fiber port; blinks
green when activity is detected on the fiber port.
TX LNK/ACT
: Glows amber when a link is established on the copper port; blinks
amber when activity is detected on the copper port.
IMC NETWORKS TECHNICAL SUPPORT
Tel:
(949) 465-3000 or (800) 624-1070 (in the U.S. and Canada);
+32-16-550880 (Europe)
Fax:
(949) 465-3020
E-Mail:
techsupport@imcnetworks.com
Web:
www.imcnetworks.com
FX LNK/ACT
TX LNK/ACT
5
DC POWER SUPPLY PRECAUTIONS
The following precautions should be observed when installing chassis with DC power
supplies.
1.
Check nameplate ratings to assure there is no overloading of supply circuits that
could have an effect on overcurrent protection and supply wiring.
2.
When installing 7 – 50V DC rated equipment, it must be installed only per the
following conditions:
a.
Connect the equipment to a 7 – 50V DC supply source that is electrically
isolated form the alternating current source. The 7 – 50V DC source must
be connected to a 7 – 50V DC SELV source.
b.
The maximum terminal voltage is 50 VDC.
c.
Input wiring to terminal block must be routed and secured in such a
manner that it is protected from damage and stress. Do not route wiring
past sharp edges or moving parts.
d.
A readily accessible disconnect device, with a 3mm minimum contact gap,
shall be incorporated in the fixed wiring.
3.
Grounding: reliable grounding of this equipment must be maintained. Particular
attention should be given to supply connections when connecting to power
strips, rather than direct connections to the branch circuit. The Negative
Terminal is common to the grounded case.
OPERATING THE IE-GIGA-MINIMC
IE-Giga-MiniMc offers plug-and-play operation, including the AutoCross feature
which automatically selects between a crossover workstation or straight-through
connection depending on the connected device. IE-Giga-MiniMc also provides Flow
Control, and allows jumbo packets of up to 1632 bytes.
2
INSTALLING THE IE-GIGA-MINIMC
IE-Giga-MiniMc installs virtually anywhere: as a standalone, table-top device or on a
DIN rail. As a standalone device, install IE-Giga-MiniMc in locations with extremely
limited space. Also included are Velcro strips to attach the device to most surfaces.
Installation Tip
Several models of the IE-Giga-MiniMc support single-strand fiber for operation.
Since single-strand fiber products use optics that transmit and receive on two
different wavelengths, single-strand fiber products must be deployed in pairs. For
example, connect an IE-Giga-MiniMc, TX/SSLX-SM1310-SC (which has 1310 xmt
and 1550 rcv) to a product which has 1550 xmt and 1310 rcv, e.g. iMcV-Gigabit,
TX/SSLX-SM1550-SC. The two connected products must also have the same
speed and distance capabilities (i.e. both are single-mode [20km] or both are
single/PLUS [40km]).
DIN Rail Mounting
The IE-Giga-MiniMc ships from the factory with
DIN clips, allowing installation on a DIN rail. The
IE-Giga-MiniMc mounts perpendicular to the DIN
rail (as shown).
You can mount the IE-Giga-MiniMc perpendicular
to the DIN rail.
Use the supplied screws to attach the DIN clips to
the IE-Giga-MiniMc, then snap the converter to the
DIN rail.
To remove the converter from the DIN rail, use a
flat-head screwdriver in the slot to gently pry the
converter from the rail.
NOTE
The DIN clips are designed for use on a DIN-35 rail.
3
POWERING THE IE-GIGA-MINIMC
IE-Giga-MiniMc supports two powering options. You can use one of the following
options, or both for redundancy:
A country-specific AC power adapter (included)
The 4-terminal DC power block
AC Power Operation
Only connect an IMC Networks’ power adapter to the adapter jack. Using a non-
IMC Networks power adapter in this jack will void the warranty.
DC Terminal Block Wiring Instructions
You can also power the IE-Giga-MiniMc with the DC terminal block. From a power
source, connect to any one positive and any one negative terminal on IE-Giga-
MiniMc.
NOTE
When using stranded wire, the leads must be tinned, and equivalent to a 16 AWG
solid conductor.
The IE-Giga-MiniMc is protected against mis-wiring; if mis-wired
the IE-Giga-MiniMc will not function. The IE-Giga-MiniMc body is internally
connected to the negative DC power terminals.
+5 VDC
Connected to
Chassis
4
Cascading Power
When installing multiple IE-Giga-MiniMc units on a DIN rail, you
can use one DC input source and then cascade from one
DC block to the next, until reaching the maximum
electrical current available.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

IMC Networks IE-Giga-MiniMc Mode d'emploi

Catégorie
Convertisseurs de média réseau
Taper
Mode d'emploi

dans d''autres langues