Tekniske data
Technical data
Technische Daten
Caractéristiques Techniques
Forsyningsspænding
Nominel spænding (Vbat): 12 V
Spændingsområde (Vbat): 11 V - 15 V
Max ripple: 5%
Strømforbrug (mode: aktiveret) 750 mA
Strømforbrug (mode: power save) 75 mA
Eektforbrug (mode: activeret) 9 W
Eektforbrug (mode: power save) 0.9 W
NB: Max. strøm gennem bussen: 7.5 A
Max. antal PVED i kæde 10
(10 x 750 mA = 7.5A)
Supply voltage
Rated voltage (Vbat): 12 V
Voltage range (Vbat): 11 V - 15 V
Max. ripple: 5%
Current consumption (mode: activated) 750 mA
Current consumption (mode: power-save) 75 mA
Power consumption (mode: activated) 9 W
Power consumption (mode: power-save) 0.9 W
NB: Max. amperage through bus: 7.5 A
Max. no. of PVEDs in chain 10
(10 x 750 mA = 7.5 A)
Versorgungsspannung
Nennspannung (Vbat): 12 V
Spannungsbereich (Vbat): 11 V - 15 V
Max. Klirrfaktor: 5%
Stromaufnahme (Betriebsart: aktiviert) 750 mA
Stromaufnahme (Betriebsart: leistungssparend) 75 mA
Leistungsaufnahme (Betriebsart: aktiviert) 9 W
Leistungsaufnahme (Betriebsart: leistungssparend) 0,9 W
NB: Max. Strom durch den Bus: 7,5 A
Max. Anzahl PVEDs in Kettenschaltung 10
(10 x 750 mA = 7,5 A)
Tension d’alimentation
Tension nominale (Vbat) : 12 V
Plage de tension (Vbat) : 11 V -15 V
Ondulation résiduelle maximale : 5%
Ampérage consommé (mode activé) 750 mA
Ampérage consommé (mode économie d’énergie) 75 mA
Puissance consommée (mode activé) 9 W
Puissance consommée (mode économie d’énergie) 0,9 W
N.B. : Courant max. traversant le bus : 7,5 A
Nombre maximum de PVED dans la chaîne 10