ResMed Mirage FX For Her Nasal CPAP Mask Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

Mirage™ FX for Her
NASAL MASK
User Guide
English • Français • Español • Português
628024r2 Mirage FX for Her AMER Multi.indb 1 2/11/2012 2:26:15 PM
Did you know?
Replacing your mask and supplies is
one of the most important steps in
maintaining effective therapy.
Replace when...
The cushion is no longer clear and
transparent.
The cushion is cracked, torn or
damaged in any way.
The headgear is stretched and
needs to be tightened more than
when it was new.
What to do...
Consult your equipment provider to learn
what replacement schedule may be
available through your insurance policy.
628024r2 Mirage FX for Her AMER Multi.indb 1 2/11/2012 2:26:23 PM
i
Fitting/Ajustement/Colocación/Colocação e ajuste
3
1
4
5
6
Mirage FX
for Her
Mirage FX
for Her
2
Mirage™ FX for Her
nasal mask
628024r2 Mirage FX for Her AMER Multi.indb 1 2/11/2012 2:26:24 PM
ii iii
Removal/Retrait/Remoción/Remoção
Disassembly/Démontage/Desmontaje/Desmontagem
1
2
1
2
3
628024r2 Mirage FX for Her AMER Multi.indb 2 2/11/2012 2:26:25 PM
ii iii
Reassembly/Remontage/Montaje/Remontagem
1
2
3
4
628024r2 Mirage FX for Her AMER Multi.indb 3 2/11/2012 2:26:25 PM
iv v
Mirage FX for Her
A
B
3
1
5
4
6
2
7
628024r2 Mirage FX for Her AMER Multi.indb 4 2/11/2012 2:26:25 PM
iv v
Mask components/Composants du masque/
Piezas de la mascarilla/Componentes da máscara
Item/
Article/
Artículo/
Item
Description/Description/Descripción/Descrição
1 Mask frame/Entourage rigide/Armazón de la mascarilla/
Armação da máscara
2 Forehead support/Support frontal/Apoyo para la frente/
Suporte para a testa
3 Cushion/Bulle/Almohadilla/Almofada
4 Vent/Orifice de ventilation/Ventilación/Respiradouro
5 Headgear/Harnais/Arnés/Arnês
6 Elbow assembly/Ensemble coude/Conjunto del codo/
Conjunto do cotovelo
7 Elbow side tabs/Pattes d’attache latérales coude/
Lengüetas laterales del codo/Abas laterais do cotovelo
A Complete system/Système complet/Sistema completo/
Sistema completo
B Frame system/Entourage complet/Sistema de armazón/
Sistema da armação
628134 Mirage FX for Her AMER Multi.indb 5 18/04/2018 9:52:16 AM
1
English
Mirage™ FX for Her
Nasal MasK
Thank you for choosing the Mirage FX for Her. Please read the entire
manual before use.
Intended use
The Mirage FX for Her channels airflow non-invasively to a patient
from a continuous positive airway pressure (CPAP) or bilevel device.
The Mirage FX for Her is:
to be used by patients (> 66 lb/30 kg) for whom positive airway
pressure has been prescribed
intended for single-patient re-use in the home environment and
multipatient re-use in the hospital/institutional environment.
WARNING
The vent holes must be kept clear.
This mask should only be used with CPAP or bilevel devices
recommended by a physician or respiratory therapist.
The mask should not be used unless the device is turned on.
Once the mask is fitted, ensure the device is blowing air.
Explanation: CPAP and bilevel devices are intended to be
used with special masks (or connectors which have vent holes
to allow continuous flow of air out of the mask. When the
device is turned on and functioning properly, new air from
the device flushes the exhaled air out through the mask vent
holes. However, when the device is not operating, insufficient
fresh air will be provided through the mask, and the exhaled
air may be rebreathed. Rebreathing of exhaled air for longer
than several minutes can, in some circumstances, lead to
suffocation. This applies to most models of CPAP or bilevel
devices.
Follow all precautions when using supplemental oxygen.
Oxygen flow must be turned off when the CPAP or bilevel
device is not operating, so that unused oxygen does not
accumulate within the device enclosure and create a
risk of fire.
Remove all packaging before using the mask.
628024r2 Mirage FX for Her AMER Multi.indb 1 2/11/2012 2:26:26 PM
2
Oxygen supports combustion. Oxygen must not be used while
smoking or in the presence of an open flame. Only use oxygen
in well ventilated rooms.
Using your mask
When using your mask with ResMed CPAP or bilevel devices that
have mask setting options, refer to the Technical specifications section
in this user guide for mask setting options.
For a full list of compatible devices for this mask, see the
Mask/Device Compatibility List on www.resmed.com on the
Products page under Service & Support. If you do not have internet
access, please contact your ResMed representative.
Note: If you experience nasal dryness or irritation, using a humidifier
is recommended.
Fitting
The fitting illustrations section in this user guide show the sequence
for obtaining the best fit and comfort when using your mask.
Fitting steps
Prior to fitting your mask, remove the elbow from the mask by
pressing the side tabs. Connect the elbow to your device air tubing.
1. With both lower headgear straps released, hold the mask
against your face and pull the headgear over your head.
2. Bringing the lower straps below your ears, loop the headgear
into the lower hooks on the mask frame.
3. Unfasten the Velcro
®
, pull the upper headgear straps evenly
until they are comfortable and reattach the Velcro. Do not
overtighten.
4. Repeat step 3 with the lower headgear straps.
5. Attach the combined elbow assembly and air tubing to the
mask by pressing the side-tabs and pushing into mask frame.
6. Your mask and headgear should be positioned as shown.
Ensure the headgear label is facing outwards.
628024r2 Mirage FX for Her AMER Multi.indb 2 2/11/2012 2:26:26 PM
3
English
Removing the mask
Refer to the removal illustrations section in this user guide. To remove
your mask, disconnect one of the lower headgear hooks and pull the
mask and headgear up over your head.
Disassembly
Refer to the disassembly illustrations in this user guide.
Disassembly steps
1. Unhook the upper headgear straps from the mask frame, there
is no need to undo the Velcro.
2. Remove the combined elbow assembly and air tubing from the
mask by pressing the side-tabs and pulling away from the mask
frame. Remove the elbow assembly from the air tubing.
3. Gently separate the cushion from the mask frame.
Reassembly
Refer to the reassembly illustrations in this user guide.
Reassembly steps
1. Ensure the cushion is oriented correctly by aligning the top
cushion tab with the recess in the top of the mask.
2. Gently pull the cushion through the front of the mask frame
until the cushion locks securely into the mask frame. The tabs
on either side of the cushion should be sitting against the mask
frame. Ensure the cushion is not twisted or distorted.
3. Attach the top headgear straps to the mask frame by looping
onto each of the upper headgear hooks.
4. Replace the elbow assembly into the air tubing and attach
the combined elbow assembly and air tubing to the mask by
pressing the side-tabs and pushing into the mask.
628024r2 Mirage FX for Her AMER Multi.indb 3 2/11/2012 2:26:26 PM
4
Cleaning your mask in the home
Your mask and headgear should only be gently handwashed.
Daily/After each use:
Disassemble the mask components according to the disassembly
instructions.
Thoroughly clean the separated mask components (excluding
headgear), by gently rubbing in warm (approximately 86°F/30°C)
water using mild soap.
To optimize the mask seal, facial oils should be removed from the
cushion after use.
Use a soft bristle brush to clean the vent.
Inspect each component and if required, repeat washing until
visually clean.
Rinse all components well with drinking quality water and allow to
air dry out of direct sunlight.
When all components are dry, reassemble according to the
reassembly instructions.
Weekly:
Handwash the headgear.
WARNING
Do not use aromatic-based solutions or scented oils (eg,
eucalyptus or essential oils), bleach, alcohol or products that
smell strongly (eg, citrus) to clean any of the mask components.
Residual vapours from these solutions can be inhaled if not
rinsed thoroughly. They may also damage the mask.
CAUTION
If any visible deterioration of a system component is apparent
(cracking, crazing, tears etc), or, if after cleaning, any component
remains unclean, the component should be discarded and
replaced.
628024r2 Mirage FX for Her AMER Multi.indb 4 2/11/2012 2:26:26 PM
5
English
Reprocessing the mask between patients
Only Sleep Lab Mask (SLM) variants of the mask are intended
for multi-patient re-use. When using between patients, these
masks must be reprocessed according to cleaning and disinfection
instructions available on ResMed.com/downloads/masks.
Troubleshooting
Problem/possible cause Solution
Mask is too noisy
Vent is blocked or partially blocked. If the vent requires cleaning, use a
soft bristle brush.
Elbow incorrectly inserted. Remove the elbow from the mask
and then reassemble according to
the instructions.
Mask leaks around the face
Mask not positioned correctly. Gently pull the cushion away from
the face to reinflate. Reposition
your mask according to the
instructions.
Air leaking around the bridge of the nose
Mask is not tightened correctly. Tighten top headgear straps. Do
not overtighten.
Air leaking around the sides of the nose
Mask is not tightened correctly. Tighten both upper and lower
headgear straps. Do not
overtighten.
Turn off the CPAP or bilevel device
and remove mask. Refit the mask
according to the instructions.
Ensure you position the cushion
correctly on the face before pulling
headgear over the head.
Do not slide mask down the face
during fitting as this may lead to
folding or curling of the cushion.
628134 Mirage FX for Her AMER Multi.indb 5 18/04/2018 9:52:16 AM
6
The mask does not fit properly
Mask is incorrectly assembled. Disassemble the mask, then
reassemble according to the
instructions.
Cushion may be dirty. Clean cushion according to the
instructions.
WARNING
The technical specifications of the mask are provided for your
clinician to check that they are compatible with the CPAP or
bilevel device. If used outside specification or if used with
incompatible devices; the seal and comfort of the mask may
not be effective; optimum therapy may not be achieved; and
leak, or variation in the rate of leak may affect the CPAP or
bilevel device function.
Discontinue using this mask if you have ANY adverse reaction
to the use of the mask, and consult your physician or sleep
therapist.
Using a mask may cause tooth, gum or jaw soreness or
aggravate an existing dental condition. If symptoms occur,
consult your physician or dentist.
As with all masks, some rebreathing may occur at low CPAP
pressures.
Refer to your CPAP or bilevel device manual for details on
settings and operational information.
At a fixed rate of supplemental oxygen flow, the inhaled oxygen
concentration varies, depending on the pressure settings, patient
breathing pattern, mask, point of application and leak rate. This
warning applies to most types of CPAP devices.
628024r2 Mirage FX for Her AMER Multi.indb 6 2/11/2012 2:26:26 PM
7
English
Technical specifications
Pressure–flow
curve
The mask contains passive venting to protect against
rebreathing. As a result of manufacturing variations,
the vent flow rate may vary.
Vent flow rate (L/min)
0
10
20
30
40
50
60
4 6 8 10 12 14 16 18 20
Mask pressure (cm H
2
O)
Pressure
(cm H
2
O)
Flow
(L/min)
4 19
8 28
12 34
16 40
20 45
Dead space
information
Physical dead space is the empty volume of the mask
to the end of the swivel.
FX: 93 mL
FX Small: 71 mL
Therapy
pressure
4 to 20 cm H
2
O
Resistance Drop in pressure measured (nominal)
at 50 L/min: 0.2 cm H
2
O
at 100 L/min: 1.0 cm H
2
O
Environmental
conditions
Operating temperature: +41°F to +104°F
(+5°C to +40°C)
Operating humidity: 15% to 95% non-condensing.
Storage and transport: -4°F to +140°F
(-20°C to +60°C)
Storage and transport humidity: up to 95% non-
condensing.
Gross
dimensions
Mask fully assembled with elbow assembly – no
headgear.
FX: 5.43“ (H) x 3.38“ (W) x 3.46 “ (D)
138 mm (H) x 86 mm (W) x 88 mm (D)
FX Small: 4.88“ (H) x 3.23“ (W) x 3.46 “ (D)
124 mm (H) x 82 mm (W) x 88 mm (D)
628024r2 Mirage FX for Her AMER Multi.indb 7 2/11/2012 2:26:26 PM
8
Mask setting
options
For S9: Select ‘NASAL
For other devices: Select ‘STANDARD’, otherwise
select ‘VISTA’ as the mask option.
Notes:
The mask system does not contain PVC, DEHP or phthalates.
This product does not contain natural rubber latex.
The manufacturer reserves the right to change these
specifications without notice.
Storage
Ensure that the mask is thoroughly clean and dry before storing it
for any length of time. Store the mask in a dry place out of direct
sunlight.
Disposal
This mask does not contain any hazardous substances and may be
disposed of with your normal household refuse.
Symbols
The following symbols may appear on your product or packaging.
Caution, consult accompanying documents;
LOT
Batch Code;
REF
Catalogue number; Temperature limitation; Humidity
limitation;
Does not contain natural rubber latex; Manufacturer;
Indicates a Warning or Caution and alerts you to a possible
injury or explains special measures for the safe and effective use
of the device;
Keep away from rain; This way up; Fragile,
handle with care;
European Authorized Representative;
Prescription only (In the US, Federal law restricts these devices to
sale by or on the order of a physician.)
628024r2 Mirage FX for Her AMER Multi.indb 8 2/11/2012 2:26:28 PM
9
English
Limited warranty
ResMed
Pty Ltd (hereafter ’ResMed’) warrants that your ResMed
mask system (including mask frame, cushion, headgear and tubing)
shall be free from defects in material and workmanship from the date
of purchase for the period of 90 days or in the case of disposable
masks the maximum use period.
This warranty is only available to the initial consumer. It is not
transferable.
If the product fails under conditions of normal use ResMed will
repair or replace, at its option, the defective product or any of its
components.
This limited warranty does not cover: a) any damage caused as
a result of improper use, abuse, modification or alteration of the
product; b) repairs carried out by any service organization that has not
been expressly authorized by ResMed to perform such repairs; and
c) any damage or contamination due to cigarette, pipe, cigar or other
smoke.
Warranty is void on product sold, or resold, outside the region of
original purchase.
Warranty claims on defective product must be made by the initial
consumer at the point of purchase.
This warranty replaces all other expressed or implied warranties,
including any implied warranty of merchantability or fitness for a
particular purpose. Some regions or states do not allow limitations on
how long an implied warranty lasts, so the above limitation may not
apply to you.
ResMed shall not be responsible for any incidental or consequential
damages claimed to have resulted from the sale, installation or use
of any ResMed product. Some regions or states do not allow the
exclusion or limitation of incidental or consequential damages, so
the above limitation may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights which vary
from region to region. For further information on your warranty rights,
contact your local ResMed dealer or ResMed office.
628024r2 Mirage FX for Her AMER Multi.indb 9 2/11/2012 2:26:28 PM
Le saviez-vous?
Il est essentiel de remplacer votre
masque et les fournitures afin de garantir
l'efficacité du traitement.
Remplacez...
si la bulle n'est plus claire et
transparente;
si la bulle est fissurée, déchirée ou
endommagée d'une quelconque
manière;
si le harnais est étiré et qu'il faut le
serrer davantage qu'à l'état neuf.
Procédure...
Contactez votre consultant en soins
à domicile pour en savoir plus sur la
fréquence de remplacement prise en
charge par votre police d'assurance.
628024r2 Mirage FX for Her AMER Multi.indb 1 2/11/2012 2:26:35 PM
1
Français
Mirage™ FX for Her
MASQUE nASAl
Merci d'avoir choisi le Mirage FX for Her. Veuillez lire le guide dans
son intégralité avant d’utiliser ce masque.
Usage prévu
Le Mirage FX for Her achemine au patient de façon non invasive le
débit d'air produit par un appareil à pression positive continue (PPC)
ou une VNDP.
Le Mirage FX for Her est prévu pour:
une utilisation par des patients adultes (>66lb/30kg) à qui une
pression positive a été prescrite;
un usage multiple par un seul patient à domicile ou pour un usage
multiple par plusieurs patients en milieu médical.
AVERTISSEMENT
Les orifices de ventilation ne doivent jamais être obstrués.
Ce masque ne doit être utilisé qu'avec des appareils de PPC
oude VNDP recommandés par un médecin ou un spécialiste
de la respiration.
Le masque ne peut être porté que si l’appareil est sous
tension. Une fois le masque en place, s’assurer que l’appareil
produit un débit d’air.
Explication : les appareils de PPC et de VNDP sont utilisés
avec des masques (ou des connecteurs) spéciaux possédant
des orifices de ventilation permettant l'expulsion continue de
l'air en dehors du masque. Lorsque l'appareil est mis sous
tension et fonctionne correctement, il produit de l'air frais
qui expulse l'air expiré, à travers les orifices de ventilation
du masque. Toutefois, lorsque l'appareil ne fonctionne pas,
une quantité insuffisante d'air frais est produite et l'air expiré
risque d'être de nouveau inhalé. La réinspiration d'air inspiré,
pendant une période supérieure à plusieurs minutes peut,
dans certaines circonstances, provoquer une suffocation. La
plupart des appareils de PPC et de VNDP sont concernés par
ce problème.
628024r2 Mirage FX for Her AMER Multi.indb 1 2/11/2012 2:26:35 PM
2
Prendre toutes les précautions applicables lors de l’adjonction
d’oxygène.
L’oxygène est inflammable. Il ne faut pas fumer et utiliser de
l'oxygène en même temps ni utiliser de l'oxygène en présence
d'une flamme nue. L'oxygène ne doit être utilisé que dans des
salles bien ventilées.
L’arrivée d’oxygène doit être fermée lorsque l’appareil de PPC
ou la VNDP n’est pas en marche afin d’empêcher l’oxygène
inutilisé de s’accumuler dans le boîtier de l’appareil et de créer
un risque d’incendie.
Retirer tout l’emballage avant d’utiliser le masque.
Utiliser votre masque
Si vous utilisez le masque avec un appareil de PPC ou une VNDP
ResMed disposant d’une fonction de sélection du masque, veuillez
consulter la partie Caractéristiques de ce guide utilisateur pour
davantage d’informations sur cette fonction.
Pour une liste complète des appareils compatibles avec ce masque,
veuillez consulter la liste de compatibilité entre les masques et les
appareils sur le site www.resmed.com à la page Produits, sous la
rubrique SAV et assistance. Si vous n'avez pas accès à Internet,
veuillez contacter votre revendeur ResMed.
Remarque: En cas de sécheresse ou d’irritation nasale, il est
recommandé d’utiliser un humidificateur.
Mettre le masque en place
Les illustrations de ce guide utilisateur indiquent comment mettre en
place le masque afin d’obtenir un ajustement et un confort optimaux
lors de son utilisation.
Procédure d’ajustement
Avant de mettre votre masque, retirez le coude du masque en
appuyant sur les pattes d'attache latérales. Raccordez le coude au
circuit respiratoire de votre appareil.
1. Avec les deux sangles inférieures du harnais détachées,
maintenez fermement le masque sur votre visage et faites
passer le harnais par-dessus votre tête.
628024r2 Mirage FX for Her AMER Multi.indb 2 2/11/2012 2:26:35 PM
3
Français
2. En faisant passer les sangles inférieures sous vos oreilles,
attachez le harnais en formant une boucle dans les crochets
inférieurs de l'entourage rigide du masque.
3. Défaites les bandes Velcro
®
, tirez sur les sangles supérieures
du harnais de façon égale jusqu'à ce qu'elles soient
confortables et rattachez les bandes Velcro. Ne serrez pas trop
fort.
4. Veuillez répéter l'étape3 pour les sangles inférieures du
harnais.
5. Branchez l'ensemble coude et circuit respiratoire au masque en
appuyant sur les pattes d'attache latérales et en poussant sur
l'entourage rigide du masque.
6. Le masque et le harnais doivent être positionnés comme
indiqué sur l'illustration. Assurez-vous que l'étiquette du harnais
est bien dirigée vers l'extérieur.
Retirer le masque
Veuillez consulter les illustrations de retrait que vous trouverez dans
ce guide utilisateur. Pour retirer votre masque, détachez l'un des
crochets inférieurs du harnais et faites passer le masque et le harnais
par-dessus votre tête.
Démonter le masque
Veuillez consulter les illustrations de démontage que vous trouverez
dans ce guide utilisateur.
Procédure de démontage
1. Décrochez les sangles supérieures du harnais de l'entourage
rigide du masque (il n'est pas nécessaire de défaire les bandes
Velcro).
2. Retirez l'ensemble coude et circuit respiratoire du masque en
appuyant sur les pattes d'attache latérales et en tirant pour le
retirer de l'entourage rigide. Retirez l'ensemble coude du circuit
respiratoire.
3. Retirez la bulle de l’entourage avec précaution.
628024r2 Mirage FX for Her AMER Multi.indb 3 2/11/2012 2:26:35 PM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53

ResMed Mirage FX For Her Nasal CPAP Mask Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à