1154 WIRELESS FOUR-ZONE
INPUT MODULE
Installation Guide
DESCRIPTION
The 1154 Wireless Four-Zone Input
Module is designed to convert up
to four existing normally closed,
hardwired zones (such as motion
sensors, door & window contacts,
etc.) into wireless zones.
When a DMP panel is installed in
a location with an existing non-
DMP panel, then the 1154 can
be connected to the existing
panel’s 12V auxiliary power. Once
connected, the 1154 Wireless Input
Module converts up to four existing
hardwired zones into wireless
zones. This allows the new DMP
panel to communicate with the
existing zones.
Compatibility
All DMP 1100 Series Wireless
Receivers and burglary panels
What is Included?
1154 Wireless Four-Zone Input
Module
3V Lithium CR123A battery
Hardware pack
1PROGRAM THE PANEL
The 1154 can be programmed with up to four zones. When
programming the 1154 in the panel, refer to the panel programming
guide as needed.
1. In ZONE INFORMATION, enter the zone number. Press CMD.
2. Enter the ZONE NAME and press CMD.
3. Once ZONE TYPE appears, select the appropriate zone type.
Press CMD.
4. At the NEXT ZONE prompt, select NO. If you see the
WIRELESS ZONE prompt, select YES.
Note: This option only displays if the zone number can be
programmed as wireless. This option does not appear for
hardwire zones.
5. Enter the eight-digit SERIAL NUMBER. Press CMD.
6. Enter the CONTACT number being used.
7. Enter the SUPERVSN TIME and press CMD.
8. At the NEXT ZONE prompt, select YES and continue to
program up to three more zones.
Note: Zones must be entered sequentially.
Figure 1: 1154
PANEL ZONES
XT30/XT50,
XTLplus,
& XTLtouch
The zone numbers begin with the 1154 address and are
followed by the particular zone from the 1154. For exam-
ple, an 1154 at keypad address 4 would provide zones 41,
42, 43, and 44.
XR150 Zone numbers are valid from 500-599. Zones must still be
programmed sequentially (i.e. 551, 552, 553, and 554).
XR550 Zone numbers are valid from 500-999. Zones must still be
programmed sequentially (i.e. 551, 552, 553, and 554).
Use an 1106 Universal Wireless Transmitter to determine the
location of the 1154.
The 1106 provides a Survey LED capability to allow one person to
confirm communication with the wireless receiver or panel while
the cover is removed.
1. Hold the 1106 in the exact desired location.
2. Press the tamper switch to send data to the panel and
determine if communication is confirmed or faulty.
Confirmed: If communication is confirmed, for each press
or release of the tamper switch the LED blinks immediately
on and immediately o. Repeat this test to confirm five
separate consecutive LED blinks. Any indication otherwise
means proper communication has not been established.
Faulty: If communication is faulty, the LED remains on for
about 8 seconds or flashes multiple times in quick
succession. Relocate the transmitter or receiver until the
LED confirms clear communication.
SELECT A LOCATION
2
2 1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
Option A: Power from an Existing Panel
Use power from an existing panel to connect the 1154 to powered zones such as PIRs or glassbreak
detectors. The existing panel must be connected to AC power. The powered zones must be connected to the
existing panel or another power supply for power.
1. Place the jumper on the two power source selector pins labeled EXT to enable external power supply
operation.
2. Using 18–22 gauge wire, connect a black wire to the ground terminal on the existing panel, and a red
wire to a terminal on the panel with 12VDC power. See Figure3.
3. Connect the black wire to the negative terminal on the input power terminal block on the 1154, and
the red wire to the positive terminal.
4. Snap the housing cover into place.
+
+
_
Figure 3: Power from an Existing Panel
Existing Panel AC
Power
Supply
Back-Up
Battery
GND
18–22
Gauge
Wire
Non-
Powered
Zone
Device 4
Non-
Powered
Zone
Device 3
Non-
Powered
Zone
Device 2
Non-
Powered
Zone
Device 1
Zone Wiring
Terminals
Input Power
Terminal
Block
Power Source
Selector Pins
GND
3V
Lithium
Battery
Wire the zones and connect the receiver before installing the battery or connecting a power supply to the
1154.
1. Locate the existing contacts that you want to connect to the 1154. These contacts should be within
100feet of the 1154.
2. Use 18–22 gauge wire to connect a zone device to terminals Z1+ and Z1-.
3. Repeat step2 for the remaining zones as needed.
Note: When wiring normally closed contacts, EOL resistors do not need to be changed or
removed.
4WIRE THE 1154 ZONES
5POWER THE 1154
3MOUNT THE 1154
The 1154 should be placed close to the
existing non-DMP panel.
Mount the device on a flat surface such as
a wall or single-gang box. When using the
optional Model 376L plug-in power supply,
mount the device near a wall outlet. See
Figure2 for an example of all mounting holes
on the housing base. Use any combination.
Figure 2: Mounting Hole Locations
Mounting Hole
1154 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
Option B: External DC Plug-In Power Supply
Use power from the optional Model 376L plug-in DC
power supply to connect the 1154 to powered zones.
The 1154 must be mounted near a wall outlet or other
power source.
1. Place the supplied jumper on the two power
source selector pins labeled EXT to enable
external power supply operation.
2. Connect the wiring from the power supply to the
input power terminal block. Connect the black
wire to the negative terminal and the black and
white wire to the positive terminal. See Figure 4.
3. Plug the Model 376L power supply into a 110VAC
outlet.
4. Snap the housing cover into place.
- +
Figure 4: DC Terminals to Plug-In Power Supply
Option C: External 12VDC Power Supply
Power the 1154 and powered zones from the DMP Model505-12
power supply or other external 12VDC power supply with battery
backup to remove the existing non-DMP panel from the setup. Use
18–22 gauge wire to connect the 1154.
1. Place the supplied jumper on the two power source selector
pins labeled EXT to enable external power supply operation.
2. Observing the polarity of all wired connections, use 18–22
gauge wire to connect the 1154's input power terminal block to
the + DC - terminal on the 505-12power supply. See Figure 5.
3. Snap the housing cover into place.
Option D: Battery Power
Use a single CR123A 3V battery to connect the 1154 to non-powered
zones such as door or window contacts or battery-powered contacts.
Observe polarity when installing the battery into the module.
Caution: Do not connect the 1154 to an external power supply
(existing panel, plug-in power supply, 505-12) if there is a CR-123A
3V battery installed in the module.
1. If needed, remove the old battery and properly dispose of it.
2. Place the supplied jumper on the two power source selector
pins labeled BAT to enable battery operation.
3. Place a new battery into the holder and observe polarity.
4. Snap the housing cover into place.
Caution: Properly dispose of used batteries. Do not recharge,
disassemble, heat above 212°F (100°C), or incinerate.
18–22
Gauge
Wire
505-12 Power
Supply
1154 Input Power
Terminal Block
+ DC -
- +
+ BAT —
Figure 5: External 12VDC Power Supply
Back-Up
Battery
Designed, engineered, and
manufactured in Springfield, MO
using U.S. and global components.
LT-1619 22164
1154 WIRELESS
FOUR-ZONE
INPUT MODULE
Specifications
Battery
Life Expectancy 3 years
Type 3 V Lithium CR123A
Frequency Range 905-924 MHz
Dimensions 4.65” L x 3.10” W x 1.40” H
11.81 L x 7.87 W x 3.56 H cm
Color White
Housing Material Flame Retardant ABS
Accessories
CR123 DMP 3 V Lithium Battery
376L DC Plug-in Power Supply
505-12 12 VDC Power Supply
Compatibility
XT30 panels with 1100D Series Wireless Receiver with Version
105 or higher
XT50 panels with integrated wireless receiver or 1100D Series
Wireless Receiver with Version 105 or higher
XR150/XR550 Series panels with 1100X Series Wireless
Receivers with Version 105 or higher
XTLplus panels with integrated wireless receiver
XTLtouch panels with integrated wireless receiver
Patents
U.S. Patent No. 7,239,236
Certifications
FCC Part 15 Registration ID CCKPC0101
IC Registration ID 5251A-PC0101
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
800.641.4282 | DMP.com
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from
all persons. It must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment o and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
1. Reorient or relocate the receiving antenna.
2. Increase the separation between the equipment and receiver.
3. Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
4. Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA INFORMATION
This device complies with Industry Canada Licence-exempt RSS standards. Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety
Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm)
to maintain compliance with the General Population limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. Lexploitation est
autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Lexposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites établies par le
Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces (20 cm) séparant l’antenne
d’une personne présente en conformité avec les limites permises d’exposition du grand public.
© 2022
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Digital Monitoring Products 1154 Wireless Four-zone Input Module Guide d'installation

Taper
Guide d'installation