Date Issued: 09/25/17 IS-43196-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starting and during the installation.
5
2
3
1
4
6
NOTE: This xture can be mounted to a ceiling or a wall outlet box.
1) Attach mounting strap[2] to outlet box[6] with strap mounting
screws[3]. Mounting strap can be adjusted to suit position of
xture.
2) Grounding instructions: (See Illus. A or B)
A) On xtures where mounting strap is provided with a hole
and two raise dimples. Wrap ground wire from outlet box
around green ground screw, and thread into hole.
B) On xtures where a cupped washer is provided. Put
ground wire from outlet box under cupped washer and
green ground screw and thread screw into hole in mount-
ing strap.
If xture is provided with ground wire. Connect xture ground
wire to outlet box ground wire with wire connector, after follow-
ing the above steps. Never connect ground wire to black or
white power supply wires.
3) Make wire connections using supplied wire nuts[5]. Reference
chart below for correct connections and wire accordingly
4) Push xture[1] to wall or ceiling outlet box. Be sure not to pinch
wires between wall and canopy of xture.
5) Screw in two (2) mounting screws[4]: one on two sides of
canopy.
6) Insert recommended bulbs. e
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
A
B
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire