Lincoln Electric POWER MIG 256 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur
POWER MIG
®
256
OPERATORʼS MANUAL
IM10096
July, 2011
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However,
your overall safety can be
increased by proper installation
... and thoughtful operation on
your part. DO NOT INSTALL,
OPERATE OR REPAIR THIS
EQUIPMENT WITHOUT READ-
ING THIS MANUAL AND THE
SAFETY PRECAUTIONS CON-
TAINED THROUGHOUT. And,
most importantly, think before
you act and be careful.
For use with machine Code Numbers
11780, 11781
For use with machine Code Numbers
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
• World's Leader in Welding and Cutting Products •
Copyright © Lincoln Global Inc.
FOR ENGINE
powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance
work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated
areas or vent the engine exhaust fumes
outdoors.
____________________________________________________
1.c. Do not add the fuel near an open flame
welding arc or when the engine is running.
Stop the engine and allow it to cool before
refueling to prevent spilled fuel from vaporiz-
ing on contact with hot engine parts and
igniting. Do not spill fuel when filling tank. If
fuel is spilled, wipe it up and do not start
engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in
position and in good repair.Keep hands, hair, clothing and
tools away from V-belts, gears, fans and all other moving
parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety
guards to perform required maintenance. Remove
guards only when necessary and replace them when the
maintenance requiring their removal is complete.
Always use the greatest care when working near moving
parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or
idler by pushing on the throttle control rods
while the engine is running.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while
turning the engine or welding generator during maintenance
work, disconnect the spark plug wires, distributor cap or
magneto wire as appropriate.
i
SAFETY
i
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you pur-
chase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the
Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
WARNING
ELECTRIC AND
MAGNETIC FIELDS
may be dangerous
2.a. Electric current flowing through any conductor causes
localized Electric and Magnetic Fields (EMF). Welding
current creates EMF fields around welding cables and
welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health
effects which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1.
Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and
work cables. If the electrode cable is on your right
side, the work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as
possible to the area being welded.
2.d.5. Do not work next to welding power source.
1.h. To avoid scalding, do not remove the
radiator pressure cap when the engine is
hot.
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents
are known to the State of California to cause can-
cer, birth defects, and other reproductive harm.
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
The Above For Diesel Engines
The Above For Gasoline Engines
ii
SAFETY
ii
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover
plates to protect your eyes from sparks and
the rays of the arc when welding or observing
open arc welding. Headshield and filter lens
should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant
material to protect your skin and that of your helpers from
the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
ELECTRIC SHOCK can
kill.
3.a. The electrode and work (or ground) circuits
are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare
skin or wet clothing. Wear dry, hole-free
gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full
area of physical contact with work and ground.
In addition to the normal safety precautions, if welding
must be performed under electrically hazardous
conditions (in damp locations or while wearing wet
clothing; on metal structures such as floors, gratings or
scaffolds; when in cramped positions such as sitting,
kneeling or lying, if there is a high risk of unavoidable or
accidental contact with the workpiece or ground) use
the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic
welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection
should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f.
Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of
electrode holders connected to two welders because voltage
between the two can be the total of the open circuit voltage
of both welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
FUMES AND GASES
can be dangerous.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep
your head out of the fume. Use enough
ventilation and/or exhaust at the arc to keep
fumes and gases away from the breathing zone. When
welding with electrodes which require special
ventilation such as stainless or hard facing (see
instructions on container or MSDS) or on lead or
cadmium plated steel and other metals or coatings
which produce highly toxic fumes, keep exposure as
low as possible and within applicable OSHA PEL and
ACGIH TLV limits using local exhaust or mechanical
ventilation. In confined spaces or in some circum-
stances, outdoors, a respirator may be required.
Additional precautions are also required when welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected
by various factors including proper use and positioning of
the equipment, maintenance of the equipment and the spe-
cific welding procedure and application involved. Worker
exposure level should be checked upon installation and
periodically thereafter to be certain it is within applicable
OSHA PEL and ACGIH TLV limits.
5.c.
Do not weld in locations near chlorinated hydrocarbon
vapors
coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors
to
form phosgene, a highly toxic gas, and other irritating prod-
ucts.
5.d. Shielding gases used for arc welding can displace air and
cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturerʼs instructions for this
equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your
employerʼs safety practices. MSDS forms are available from
your welding distributor or from the manufacturer.
5.f. Also see item 1.b.
iii
SAFETY
iii
FOR ELECTRICALLY
powered equipment.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturerʼs
recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturerʼs recommendations.
CYLINDER may explode
if damaged.
7.a. Use only compressed gas cylinders
containing the correct shielding gas for the
process used and properly operating
regulators designed for the gas and
pressure used. All hoses, fittings, etc. should be suitable for
the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely
chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
Away from areas where they may be struck or subjected to
physical damage.
A safe distance from arc welding or cutting operations and
any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand
tight except when the cylinder is in use or connected for
use.
7.g. Read and follow the instructions on compressed gas
cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
WELDING and CUTTING
SPARKS can
cause fire or explosion.
6.a.
Remove fire hazards from the welding area.
If this is not possible, cover them to prevent
the welding sparks from starting a fire.
Remember that welding sparks and hot
materials from welding can easily go through small cracks
and openings to adjacent areas. Avoid welding near
hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site,
special precautions should be used to prevent hazardous
situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the
equipment being used.
6.c. When not welding, make certain no part of the electrode
circuit is touching the work or ground. Accidental contact
can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances
inside. They can cause an explosion even
though
they have
been “cleaned”. For information, purchase “Recommended
Safe Practices for the
Preparation
for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f.
Sparks and spatter are thrown from the welding arc. Wear oil
free protective garments such as leather gloves, heavy shirt,
cuffless trousers, high shoes and a cap over your hair. Wear
ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a
welding area.
6.g. Connect the work cable to the work as close to the welding
area as practical. Work cables connected to the building
framework or other locations away from the welding area
increase the possibility of the welding current passing
through lifting chains, crane cables or other alternate cir-
cuits. This can create fire hazards or overheat lifting chains
or cables until they fail.
6.h. Also see item 1.c.
6.I. Read and follow NFPA 51B “ Standard for Fire Prevention
During Welding, Cutting and Other Hot Work”, available
from NFPA, 1 Batterymarch Park, PO box 9101, Quincy, Ma
022690-9101.
6.j. Do not use a welding power source for pipe thawing.
Refer to http://www.lincolnelectric.com/safety for additional safety information.
iv
SAFETY
iv
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions
et les précautions de sûreté specifiques qui parraissent dans ce
manuel aussi bien que les précautions de sûreté générales suiv-
antes:
Sûreté Pour Soudage A LʼArc
1. Protegez-vous contre la secousse électrique:
a. Les circuits à lʼélectrode et à la piéce sont sous tension
quand la machine à souder est en marche. Eviter toujours
tout contact entre les parties sous tension et la peau nue
ou les vétements mouillés. Porter des gants secs et sans
trous pour isoler les mains.
b. Faire trés attention de bien sʼisoler de la masse quand on
soude dans des endroits humides, ou sur un plancher
metallique ou des grilles metalliques, principalement dans
les positions assis ou couché pour lesquelles une grande
partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble
de soudage et la machine à souder en bon et sûr état
defonctionnement.
d.Ne jamais plonger le porte-électrode dans lʼeau pour le
refroidir.
e. Ne jamais toucher simultanément les parties sous tension
des porte-électrodes connectés à deux machines à souder
parce que la tension entre les deux pinces peut être le
total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de
courant pour soudage semi-automatique, ces precautions
pour le porte-électrode sʼapplicuent aussi au pistolet de
soudage.
2. Dans le cas de travail au dessus du niveau du sol, se protéger
contre les chutes dans le cas ou on recoit un choc. Ne jamais
enrouler le câble-électrode autour de nʼimporte quelle partie
du corps.
3. Un coup dʼarc peut être plus sévère quʼun coup de soliel,
donc:
a. Utiliser un bon masque avec un verre filtrant approprié
ainsi quʼun verre blanc afin de se protéger les yeux du ray-
onnement de lʼarc et des projections quand on soude ou
quand on regarde lʼarc.
b. Porter des vêtements convenables afin de protéger la
peau de soudeur et des aides contre le rayonnement de
lʻarc.
c. Protéger lʼautre personnel travaillant à proximité au
soudage à lʼaide dʼécrans appropriés et non-inflammables.
4. Des gouttes de laitier en fusion sont émises de lʼarc de
soudage. Se protéger avec des vêtements de protection libres
de lʼhuile, tels que les gants en cuir, chemise épaisse, pan-
talons sans revers, et chaussures montantes.
5. Toujours porter des lunettes de sécurité dans la zone de
soudage. Utiliser des lunettes avec écrans lateraux dans les
zones où lʼon pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de
prévenir tout risque dʼincendie dû aux étincelles.
7. Quand on ne soude pas, poser la pince à une endroit isolé de
la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque dʼincendie.
8. Sʼassurer que la masse est connectée le plus prés possible
de la zone de travail quʼil est pratique de le faire. Si on place
la masse sur la charpente de la construction ou dʼautres
endroits éloignés de la zone de travail, on augmente le risque
de voir passer le courant de soudage par les chaines de lev-
age, câbles de grue, ou autres circuits. Cela peut provoquer
des risques dʼincendie ou dʼechauffement des chaines et des
câbles jusquʼà ce quʼils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles
galvanisées plombées, ou cadmiées ou tout autre métal qui
produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant
dʼopérations de dégraissage, nettoyage ou pistolage. La
chaleur ou les rayons de lʼarc peuvent réagir avec les vapeurs
du solvant pour produire du phosgéne (gas fortement toxique)
ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté,
voir le code “Code for safety in welding and cutting” CSA
Standard W 117.2-1974.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de
lʼélectricité et aux recommendations du fabricant. Le dispositif
de montage ou la piece à souder doit être branché à une
bonne mise à la terre.
2. Autant que possible, Iʼinstallation et lʼentretien du poste seront
effectués par un électricien qualifié.
3. Avant de faires des travaux à lʼinterieur de poste, la debranch-
er à lʼinterrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur
place.
vv
Thank You
for selecting a QUALITY product by Lincoln Electric. We want you
to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it
handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or loss of life.
This statement appears where the information must be followed to avoid minor personal injury or damage to this equipment.
CAUTION
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims
for material damaged in shipment must be made by the purchaser against the transportation company at the
time the shipment is received.
Please record your equipment identification information below for future reference. This information can be
found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you
have recorded above. The code number is especially important when identifying the correct replacement parts.
CUSTOMER ASSISTANCE POLICY
The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip-
ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask Lincoln
Electric for advice or information about their use of our products. We respond to our customers based on the best information in our posses-
sion at that time. Lincoln Electric is not in a position to warrant or guarantee such advice, and assumes no liability, with respect to such infor-
mation or advice. We expressly disclaim any warranty of any kind, including any warranty of fitness for any customerʼs particular purpose,
with respect to such information or advice. As a matter of practical consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the provision of information or advice create, expand or alter any
warranty with respect to the sale of our products.
Lincoln Electric is a responsive manufacturer, but the selection and use of specific products sold by Lincoln Electric is solely within the control
of, and remains the sole responsibility of the customer. Many variables beyond the control of Lincoln Electric affect the results obtained in
applying these types of fabrication methods and service requirements.
Subject to Change – This information is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.com
for any updated information.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet
accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our
WEB SITE at www.lincolnelectric.com. Choose “Support” and then “Register
Your Product”. Please complete the form and submit your registration.
vi vi
TABLE OF CONTENTS
Page
________________________________________________________________________
Installation .......................................................................................................Section A
Technical Specifications ........................................................................................A-1
Safety Precautions.................................................................................................A-2
Uncrating the POWER MIG
®
256 ..........................................................................A-2
Location .................................................................................................................A-2
Input Power, Grounding and Connection Diagram ........................................A-2, A-3
Output Polarity Connections..................................................................................A-3
Gun and Cable Installation ....................................................................................A-3
Shielding Gas ........................................................................................................A-4
Auxiliary Power Receptacle...................................................................................A-4
Coil Claw™ Installation..........................................................................................A-4
________________________________________________________________________
Operation .........................................................................................................Section B
Safety Precautions.................................................................................................B-1
Product Description ...............................................................................................B-2
Recommended Processes and Equipment ...........................................................B-2
Welding Capability.................................................................................................B-2
Limitations..............................................................................................................B-2
Description of Controls ..........................................................................................B-2
Wire Size Conversion Parts...................................................................................B-3
Procedure for Changing Drive Roll........................................................................B-3
Wire Reel Loading .................................................................................................B-4
Mounting of 10 to 44 lb. Spools .............................................................................B-4
To Start the Welder................................................................................................B-4
Feeding Electrode..................................................................................................B-5
Idle Roll Pressure Setting ......................................................................................B-5
Wire Drive Configuration....................................................................................... B-6
Making a Weld.......................................................................................................B-7
Avoiding Wire Feeding Problems ..........................................................................B-7
Fan Control............................................................................................................B-7
Input Line Voltage Protection.................................................................................B-7
Wire Feed Overload Protection .............................................................................B-7
Welding Thermal Overload Protection...................................................................B-8
Overcurrent Protection...........................................................................................B-8
Welding Procedure Information .............................................................................B-8
________________________________________________________________________
Accessories.....................................................................................................Section C
Drive Roll Kits........................................................................................................C-1
Dual Cylinder Mounting Kit ...................................................................................C-1
Alternative Magnum GMAW Gun and Cable Assemblies .....................................C-1
Magnum Gun Connection Kit ...............................................................................C-1
Spool Gun..............................................................................................................C-1
Connecting the Spool Gun to the
POWER MIG
®
256 ....................................................C-2
Making a Weld with the Spool Gun .......................................................................C-2
Making a Weld with the Magnum SG Spool Gun ..................................................C-3
________________________________________________________________________
vii vii
TABLE OF CONTENTS
Page
________________________________________________________________________
Maintenance ....................................................................................................Section D
Safety Precautions ................................................................................................D-1
General Maintenance ............................................................................................D-1
Drive Rolls and Guide Plates.................................................................................D-1
Contact Tip and Gas Nozzle Installation ...............................................................D-1
Gun Tubes and Nozzles........................................................................................D-1
Gun Cable Cleaning ..............................................................................................D-1
Liner Removal and Replacement ..........................................................................D-2
Liner Removal, Installation and Trimming Instructions for Magnum
®
PRO 250L..D-2
Gun Handle Disassembly......................................................................................D-3
________________________________________________________________________
Troubleshooting..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide ............................................................................E-2 thru E-4
________________________________________________________________________
Wiring Diagram and Dimension Print ............................................................Section F
________________________________________________________________________
Parts Manual....................................................................................................Appendix
POWER MIG
®
256 ...................................................................................................P-680
Magnum
®
PRO 250L Gun .........................................................................P-202-H.2
________________________________________________________________________
A-1
A-1
INSTALLATION
Input Ampere
Input Voltage Fuse or Breaker Rating On
Frequency (Hz) Size (Super Lag) Nameplate
208/60 60 56A 8
230/60 60 52A 10
230/60 60 47A 10
460/60 30 24A 14
575/60 25 19A 14
TECHNICAL SPECIFICATIONS – POWER MIG
®
256
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
Height Width Depth Weight
With Coil Claw™ Without Coil Claw™
220 lbs
32.56 in. 20.12 in. 19.15 in. 39.9in. 100 kg.
827 mm 512 mm 487 mm 1014 mm
PHYSICAL DIMENSIONS
Wire Speed 50 – 700 IPM (1.27 – 17.8 m/minute)
WIRE SPEED RANGE
Standard Voltage/Phase/Frequency
Input Current @ 200 Amp Rated Output Input Current @ 250 Amp Rated Output
208/230/1/60 Hz *47/44 Amps *56/52 Amps
230/460/575/1/60 Hz 41/20/16 Amps 47/24/19 Amps
Duty Cycle Amps Volts at Rated Amperes
40% 250 Amps 26 Volts
60% 200 Amps 28 Volts
100% 145 Amps 26 Volts
Welding Current Range (Continuous) Maximum Open Circuit Voltage Welding Voltage Range
30 – 300 Amps 40 Volts 10-28 Volts
POWER MIG
®
256
TEMPERATURE RANGES
STORAGE TEMPERATURE RANGE
-40°F to 185°F(-40°C to +85°C)
OPERATING TEMPERATURE RANGE
-4°F to 104°F(-20°C to +40°C)
* With 115V receptacle loaded to 15A.
Type S, SO, ST, STO or extra
hard usage input cord
AWG (IEC) Sizes
FIGURE A.1 — Dual Voltage Machine Input
Connections
A-2
A-2
INSTALLATION
Read entire installation section before starting
installation.
SAFETY PRECAUTIONS
INPUT POWER, GROUNDING AND
CONNECTION DIAGRAM
1. Before starting the installation, check with the local
power company if there is any question about
whether your power supply is adequate for the volt-
age, amperes, phase, and frequency specified on
the welder rating plate. Also be sure the planned
installation will meet the U.S. National Electrical
Code and local code requirements. This welder
may be operated from a single phase line or from
one phase of a two or three phase line.
2. Models that have multiple input voltages specified
on the nameplate (e.g. 208/230) are shipped con-
nected for the highest voltage. If the welder is to be
operated on lower voltage, it must be reconnected
according to the instructions in Figure A.1 for dual
voltage machines and Figure A.2 for triple voltage
machines.
Make certain that the input power is electrically
disconnected before removing the screw on the
reconnect panel access cover.
------------------------------------------------------------------------
UNCRATING THE POWER MIG
®
256
Cut banding and lift off cardboard carton. Cut banding
holding the machine to the skid. Remove foam and
corrugated packing material. Untape accessories from
Gas Bottle Platform. Unscrew the two wood screws
(at the Gas Bottle Platform) holding the machine to
the skid. Roll the machine off the skid assembly.
LOCATION
Locate the welder in a dry location where there is free
circulation of clean air into the louvers in the back and
the louvers out the front. A location that minimizes the
amount of smoke and dirt drawn into the rear louvers
reduces the chance of dirt accumulation that can
block air passages and cause overheating.
ELECTRIC SHOCK can kill.
• Only qualified personnel should
perform this installation.
• Only personnel that have read
and understood the POWER MIG
®
256 Operatorʼs Manual should
install and operate this equip-
ment.
• Machine must be grounded per
any national, local or other applic-
able electrical codes.
• The POWER MIG
®
256 power
switch is to be in the OFF posi-
tion when installing work cable
and gun and when connecting
other equipment.
WARNING
WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such as
output terminals or internal wiring.
• All input power must be electrically dis-
connected before proceeding.
WARNING
POWER MIG
®
256
Hand Screw
Male End
Gun and Cable
Gun Adapter
Receptacle
Gun Trigger
Connector
3. The 208/230 volt 60 Hz model POWER MIG is
shipped with a 10 ft. input cable and plug connect-
ed to the welder. Obtain a receptacle and mount it
in a suitable location. Be sure it can be reached by
the plug on the input cable attached to the welder.
Mount with the grounding terminal at the top to
allow the power cable to hang down without bend-
ing.
The 230/460/575 volt 60 Hz model is not equipped
with a plug, an input cable or a receptacle.
FIGURE A.2 — Triple Voltage Machine Input
Connection
4. Using the instructions in Figure A.3, have a quali-
fied electrician connect the receptacle or cable to
the input power lines and the system ground per the
U.S. National Electrical Code and any applicable
local codes. See "Technical Specifications" at the
beginning of this chapter for proper wire sizes. For
long runs over 100 feet, larger copper wires should
be used. Fuse the two hot lines with super lag type
fuses as shown in the following diagram. The center
contact in the receptacle is for the grounding
connection. A green wire in the input cable
connects this contact to the frame of the welder.
This ensures proper grounding of the welder frame
when the welder plug is inserted into the receptacle.
A-3 A-3
INSTALLATION
OUTPUT POLARITY CONNECTIONS
The welder, as shipped from the factory, is connected
for electrode positive (+) polarity. This is the normal
polarity for GMAW.
If negative (–) polarity is required, interchange the
connection of the two cables located in the wire drive
compartment near the front panel. The electrode
cable, which is attached to the wire drive, is to be con-
nected to the negative (–) labeled terminal and the
work lead, which is attached to the work clamp, is to
be connected to the positive (+) labeled terminal.
GUN AND CABLE INSTALLATION
The
Magnum
®
PRO
250L gun and cable provided with the
POWER MIG
®
256 is factory installed with a liner for .035-
.045" (0.9-1.1 mm) electrode and an .035" (0.9 mm) contact
tip.
Install the .045” tip (also provided) if this wire size
is being used.
Turn the welder power switch off before installing
gun and cable.
(See Figure A.4)
1. Lay the cable out straight.
2. Unscrew the Hand Screw on the drive unit front
end (inside wire feed compartment) until tip of
screw no longer protrudes into Gun Adapter open-
ing as seen from front of machine. (See Figure A.4)
3. Insert the male end of gun cable into the Gun
Adapter through the opening in front panel. Make
sure connector is fully inserted and tighten Hand
Screw.
4. Connect the Gun Trigger Connector from the gun
and cable to the mating Receptacle inside the
compartment located left just inside the opening on
the Front Panel. Make sure that the keyways are
aligned, insert and tighten retaining ring.
POWER MIG
®
256
FIGURE A.3 —Receptacle Diagram
CONNECT TO A SYSTEM
GROUNDING WIRE. SEE THE
UNITED STATES NATIONAL
ELECTRICAL CODE AND/OR
LOCAL CODES FOR OTHER
DETAILS AND MEANS FOR
PROPER GROUNDING.
CONNECT TO HOT WIRES OF
A THREE-WIRE, SINGLE
PHASE SYSTEM OR TO ONE
PHASE OF A TWO OR
THREE PHASE SYSTEM.
WARNING
FIGURE A.4
SHIELDING GAS
[For Gas Metal Arc Welding(GMAW) Processes]
Customer must provide cylinder of appropriate type shield-
ing gas for the process being used.
A gas flow regulator, for Argon blend gas, an inlet gas hose,
and a regulator adapter are factory provided with the
POWER MIG
®
256. When using 100% CO
2
, the regulator
adapter will be required to connect the regulator to the gas
bottle.
INSTALL SHIELDING GAS SUPPLY AS FOLLOWS:
1. Set gas cylinder on rear platform of POWER MIG
®
256.
Hook chain in place to secure cylinder to rear of welder.
2. Remove the cylinder cap. Inspect the cylinder valves and
regulator for damaged threads, dirt, dust, oil or grease.
Remove dust and dirt with a clean cloth.
DO NOT ATTACH THE REGULATOR IF OIL, GREASE
OR DAMAGE IS PRESENT! Inform your gas supplier of
this condition. Oil or grease in the presence of high pres-
sure oxygen is explosive.
3. Stand to one side away from the outlet and open the
cylinder valve for an instant. This blows away any dust or
dirt which may have accumulated in the valve outlet.
Be sure to keep your face away from the valve
outlet when “cracking” the valve.
--------------------------------------------------------------------------------
4. Attach the flow regulator to the cylinder valve and tighten
the union nut(s) securely with a wrench.
NOTE: If connecting to 100% CO
2
cylinder, the regulator
adapter provided must be installed between the regulator
and cylinder valve.
5. Attach one end of the inlet gas hose to the outlet fitting of
the flow regulator, the other end to the POWER MIG
®
256 rear fitting marked “Feeder” and tighten the union
nuts securely with a wrench.
6. Before opening the cylinder valve, turn the regulator
adjusting knob counterclockwise until the adjusting
spring pressure is released.
A-4
A-4
INSTALLATION
7. Standing to one side, open the cylinder valve slowly a
fraction of a turn. When the cylinder pressure gauge
pointer stops moving, open the valve fully.
Never stand directly in front of or behind the flow regu-
lator when opening the cylinder valve. Always stand to
one side.
--------------------------------------------------------------------------------
8. The flow regulator is adjustable. Adjust it to the flow rate
recommended for the procedure and process being used
before making the weld.
CYLINDER may explode if
damaged.
• Gas under pressure is explosive.
Always keep gas cylinders in an upright
position and always keep chained to
undercarriage or stationary support.
See American National Standard Z49.1, “Safety in
Welding and Cutting” published by the American
Welding Society.
------------------------------------------------------------------------
WARNING
WARNING
POWER MIG
®
256
AUXILIARY POWER RECEPTACLES
(For 208/230V Models only)
This machine is equipped with 15Amp 120V receptacle with
15Amp Circuit Breaker. The receptacle is UL and CSA
approved.
COIL CLAW™ INSTALLATION
The Coil Claw™ and mounting screws are provided
as an optional accessory for the
POWER MIG
®
256
.
This user-install accessory provides cable manage-
ment for the machine.
Turn the welder power switch OFF
before installing Coil Claw™.
------------------------------------------------------------------------
1. Unwrap Coil Claw™ from its protective paper and
remove the bag of mounting screws from the back
of the Coil Claw™.
2. Mount the Coil Claw™ using the provided
mount-
ing screws to the left side of the machine, when
viewed from the front. Make sure the Coil Claw™ is
firmly mounted. (See Figure A.5)
FIGURE A.5
MOUNTING
SCREWS
COIL CLAW™
WARNING
B-1
B-1
OPERATION
Read entire Operation section before
operating the POWER MIG
®
256.
ELECTRIC SHOCK can kill.
Do not touch electrically live
parts or electrode with skin or
wet clothing. Insulate yourself
from work and ground.
Always wear dry insulating
gloves.
FUMES AND GASES can be
dangerous.
• Keep your head out of fumes.
Use ventilation or exhaust to
remove fumes from breathing
zone.
WELDING SPARKS can
cause fire or explosion.
• Keep flammable material away.
Do not weld on closed contain-
ers.
ARC RAYS can burn eyes
and skin.
Wear eye, ear and body protec-
tion.
Observe all safety information throughout
this manual.
------------------------------------------------------------
WARNING
POWER MIG
®
256
B-2 B-2
OPERATION
PRODUCT DESCRIPTION
The POWER MIG
®
256 is a complete semiautomatic
constant voltage DC arc welding machine built to meet
NEMA specifications. It combines a constant voltage
power source and a constant speed wire feeder with a
microcomputer-based controller to form a reliable high-
performance welding system. A simple control
scheme, consisting of continuous full range voltage
and wire feed speed controls, provides versatility with
ease of use and accuracy. The POWER MIG
®
256 is
Spool Gun ready and includes a second Gas Solenoid
for Spool Gun use. Refer to Accessories Section for
Applicable Spool Guns.
Other features include a 2" (51 mm) O.D. wire reel
spindle with adjustable brake, an integral gas cylinder
mounting undercarriage, an adjustable CO
2
or Argon
blend flow regulator with cylinder pressure gauge and
inlet hose, a 15 ft. (4.6 m) Magnum
®
PRO 250L GMAW
gun and cable, a 10 ft. (3.1 m) power cable with plug
(208/230V models only) and a 10ft. (3.1 m) work cable
with clamp.
The POWER MIG
®
256 features built in timer functions
that provide variable burnback control, a spot function,
a selectable 4-step trigger interlock and adjustable
"Run In" for wire starting optimization. Optional
features include a Dual Cylinder Mounting kit.
RECOMMENDED PROCESSES AND
EQUIPMENT
The
POWER MIG
®
256
is recommended for GMA
welding processes using 10 to 44 lb (4.5 to 20 kg)
2"(51 mm) I.D. spools or Readi-Reel
®
coils (with
optional adapter) of .025" through .045" (0.6 – 1.1 mm)
solid steel, .035" (0.9 mm) stainless, 3/64" (1.2 mm)
aluminum and .045" (1.1 mm) Outershield
®
and
Ultracore
®
; as well as .035" (0.9 mm) and .045" (1.1
mm) Innershield
®
self-shielding electrodes.
The
POWER MIG
®
256
is factory equipped to feed .035"
(0.9 mm) and .045(1.1mm) electrode. It also includes a
200A, 60% duty cycle (or 250A, 40% duty cycle) rated,
15 ft. (4.6 m) GMAW gun and cable assembly
equipped for these wire sizes. Use of GMAW
processes requires a supply of shielding gas.
WELDING CAPABILITY
The
POWER MIG
®
256
is rated at 250 amps @ 26 volts,
at a 40% duty cycle based on a ten minute cycle time.
It is capable of higher duty cycles at lower output
currents and capable of up to 300 Amps at lower duty
cycles.
LIMITATIONS
POWER MIG
®
256 WILL NOT operate satisfactorily if
powered with a portable or in-plant generating system.
DESCRIPTION OF CONTROLS
See Figure B.1
1. Power ON/OFF Switch — Place the lever in the
"ON" position to energize the POWER MIG
®
256.
When the power is on, the red LED display lights
illuminate.
2. Voltage Control - This is a continuous control that
gives full range adjustment of power source output
voltage. It can be adjusted while welding over its 10
to 28 volt range.
3. Wire Speed Control - This controls the wire feed
speed from 50 – 700 inches per minute (1.2 – 17.8
m/min). The control can be preset on the dial to the
setting specified on the Procedure Decal on the
inside of the wire compartment door. Wire speed is
not affected when changes are made in the voltage
control.
4. Trigger Switch - Select the desired mode with the
toggle switch:
Normal Welding mode (2 Step) provides weld
power only while the trigger switch is depressed.
4-Step Trigger interlock mode eliminates the need
to hold the gun trigger while welding. It operates in 4
steps:
1. Close trigger and establish welding arc.
2. Release trigger and continue welding.
3. Reclose trigger near end of weld.
4. Release trigger again to stop welding.
If the arc is broken while using this feature, the
machine will reset to the "trigger off" condition
automatically.
Note: 4 Step Trigger interlock mode does not function
with a Spool Gun.
5. Spot Time - Spot Weld Mode is used for tack
welding parts into position or for spot plug welds to
hold thin sheet metal together prior to manual stitch
or continuous welding. To use this feature, adjust
the On-Time (0-25 seconds) as appropriate to
obtain the desired results. Closing the trigger
initiates a single timed spot weld cycle.
Plug welds are made by using a punch to make a
3/16" (5 mm) diameter hole in the top sheet and arc
welding through the hole into the back sheet.
POWER MIG
®
256
3
2
1
4
5
6
7
8
B-3
B-3
OPERATION
To make spot plug welds, punch 3/16" (5 mm) holes
in the top sheet. Set the Spot Time control to
approximately 1.2 seconds and set the procedure for
the metal thickness to be welded. Install spot weld
nozzle (if available) on gun and press it against the
top sheet so the top and bottom sheets are tight
together. Close trigger and hold it closed until the arc
goes out. If a spot weld nozzle is not used, smoother
welds will result by moving the welding wire in a
small circle during the weld.
6. Run-In Mode - is used to adjust the starting wire
feed speed. Starting conditions for certain welding
applications can be improved with adjustment to the
Run-In speed. The control allows for initial starting
speeds from 50 - 150 IPM. After the arc is started,
the set point on the wire feed speed control will
dominate. Note that the Run-in is not functional with
the spool gun. Also note that if Run-in is set fully
counter clockwise to "OFF", Run-in speed will equal
the preset WFS on the machine.
7. Burnback Time - Provides manual adjustment of
the burnback time (0-250 milliseconds) for any
selected welding mode. this control should be set as
low as possible without the wire "sticking" in the
puddle after each weld. Too long of a burnback time
may form a "ball" on the end of the wire, or may
"flash back" to the gun tip.
8. Spool Gun Gas Connection
FIGURE B.1
The drive rolls installed with the POWER MIG® 256
have two grooves one for .035(0.9mm) wire Solid
Steel electrode and the other for .045(1.1mm) wire.
Drive roll size is stenciled on each side of the drive
roll. If feeding problems occur, check to make sure
that the wire size and the drive roll size matches. See
"Procedure for Changing Drive Roll" in this section.
This information also appears on the Procedure Decal
on the door inside the wire compartment.
WIRE SIZE CONVERSION PARTS
The POWER MIG® 256 is rated to feed .025 through
.045" (0.6-1.1 mm) solid or cored electrode sizes.
The drive roll kits and Magnum
®
PRO 250L gun and
cable parts are available to feed different sizes and
types of electrodes. See Accessories section.
PROCEDURE FOR CHANGING
DRIVE AND IDLE ROLL SETS
1. Turn off the power source.
2. Release the pressure on the idle roll by swinging
the adjustable pressure arm down toward the back
of the machine. Lift the cast idle roll assembly and
allow it to sit in an upright position.
3. Remove the outside wire guide retaining plate by
loosening the two large knurled screws.
4. Twist the drive roll retaining mechanism to the
unlocked position as shown below and remove the
drive roll. (See Figure B.2)
FIGURE B.2
5. Remove the inside wire guide plate.
6. Replace the drive and idle rolls and inside wire
guide with a set marked for the new wire size.
NOTE: Be sure that the gun liner and contact tip
are also sized to match the selected wire size.
7. Manually feed the wire from the wire reel, over the
drive roll groove and through the wire guide and
then into the brass bushing of the gun and cable
assembly.
8. Replace the outside wire guide retaining plate by
tightening the two large knurled screws. Reposition
the adjustable pressure arm to its original position
to apply pressure. Adjust pressure as necessary.
LOCKED POSITION
UNLOCKED POSITION
POWER MIG
®
256
B-4 B-4
OPERATION
FIGURE B.3
POWER MIG
®
256
WIRE REEL LOADING - READI
REELS, SPOOLS OR COILS
To Mount a 30 Lb. (14 kg) Readi-Reel Package
(Using the Molded Plastic K363-P Readi-Reel
Adapter:)
(See Figure B.3)
1. Open the Wire Drive Compartment Door.
2. Depress the Release Bar on the Retaining Collar
and remove it from the spindle.
3. Place the Optional Adapter on the spindle.
4. Re-install the Retaining Collar. Make sure that the
Release Bar "pops up" and that the collar retainers
fully engage the retaining ring groove on the spindle.
5. Rotate the spindle and adapter so the retaining
spring is at the 12 o'clock position.
6. Position the Readi-Reel so that it will rotate in a
direction when feeding so as to be de- reeled from
top of the coil.
7. Set one of the Readi-Reel inside cage wires on the
slot in the retaining spring tab.
8. Lower the Readi-Reel to depress the retaining
spring and align the other inside cage wires with the
grooves in the molded adapter.
9. Slide cage all the way onto the adapter until the
retaining spring "pops up" fully.
CHECK TO BE SURE THE RETAINING SPRING
HAS FULLY RETURNED TO THE LOCKING
POSITION AND HAS SECURELY LOCKED THE
READI-REEL CAGE IN PLACE. RETAINING
SPRING MUST REST ON THE CAGE, NOT THE
WELDING ELECTRODE.
-----------------------------------------------------------------------
10. To remove Readi-Reel from Adapter, depress
retaining spring tab with thumb while pulling the
Readi-Reel cage from the molded adapter with
both hands. Do not remove adapter from spindle.
CAUTION
2 IN. O.D.
SPINDLE
ADAPTER
RETAINING
SPRING
BRAKE
HOLDING
PIN
GROOVES
READI-REEL
INSIDE
CAGE
WIRES
RELEASE
BAR
RETAINING
COLLAR
To Mount 10 to 44 Lb. (4.5-20 kg) Spools (12"/300
mm Diameter) or 14Lb.(6 Kg) Innershield Coils:
(For 13-14 lb. (6 Kg) Innershield coils, a K435 Coil
Adapter must be used).
(For 10 lb.(4.5 Kg) 8 inch(203mm) diameter spools, a
K468 spindle adapter must be used).
1. Open the Wire Drive Compartment Door.
2. Depress the Release Bar on the Retaining Collar
and remove it from the spindle.
3. Place the spool on the spindle making certain the
spindle brake pin enters one of the holes in the
back side of the spool (Note: an arrow mark on the
spindle lines up with the brake holding pin to assist
in lining up a hole). Be certain the wire comes off
the reel in a direction so as to de-reel from the top
of the coil.
4. Re-install the Retaining Collar. Make sure that the
Release Bar "pops up" and that the collar retainers
fully engage the retaining ring groove on the spin-
dle.
TO START THE WELDER
Turn the "Power Switch" switch to "ON". This lights
the red LED display lights. With the desired voltage
and wire speed selected, operate the gun trigger for
welder output and to energize the wire feed motor.
The pressure arm controls the amount of force the
drive rolls exert on the wire. Proper adjustment of both
pressure arm gives the best welding performance. For
best results, set both pressure arms to the same
value.
Set the pressure arm as follows (See Figure B.4):
Aluminum wires between 1 and 3
Cored wires between 3 and 4
Steel, Stainless wires between 4 and 6
B-5
B-5
OPERATION
ALUM INUM
OU TE R S HIE L D
METAL SHIELD
IN NERS HIEL D
STEEL
STAIN LESS
CORED WIRES
SOL ID WIR ES
6
1
3
2
5
4
FIGURE B.4
POWER MIG
®
256
FEEDING WIRE ELECTRODE
When triggering, the electrode and drive mecha-
nism are electrically "hot" relative to work and
ground and remain "hot" several seconds after
the gun trigger is released.
-----------------------------------------------------------------------
NOTE: Check that drive rolls, guide plates and gun
parts are proper for the wire size and type being used.
Refer to Table C.1 in Accessories section.
1. Turn the Readi-Reel or spool until the free end of
the electrode is accessible.
2. While securely holding the electrode, cut off the
bent end and straighten the first six inches. (If the
electrode is not properly straightened, it may not
feed properly through the wire drive system).
3. Release the pressure on the idle roll by swinging the
adjustable pressure arm down toward the back of
the machine. Lift the cast idle roll assembly and
allow it to sit in an upright position. Leave the outer
wire guide plate installed. Manually feed the wire
through the incoming guide bushing and through the
guide plates (over the drive roll groove). Push a
sufficient wire length to assure that the wire has fed
into the gun and cable assembly without restriction.
Reposition the adjustable pressure arm to its origi-
nal position to apply pressure to the wire.
4. Press gun trigger to feed the electrode wire through
the gun.
IDLE ROLL PRESSURE SETTING
ELECTRIC SHOCK can kill.
Turn the input power OFF at the weld-
ing power source before installation or
changing drive rolls and/or guides.
• Do not touch electrically live parts.
When inching with the gun trigger, electrode
and drive mechanism are "hot" to work and
ground and could remain energized several sec-
onds after the gun trigger is released.
• Only qualified personnel should perform mainte-
nance work.
------------------------------------------------------------------------
WARNING
WARNING
B-6 B-6
OPERATION
GUN RECEIVER BUSHING
LOOSEN TIGHTEN
THUMB SCREW
OUTER WIRE GUIDE
SOCKET HEAD
CAP SCREW
CONNECTOR BLOCK
WIRE DRIVE CONFIGURATION
(See Figure B.5)
Changing the Gun Receiver Bushing
ELECTRIC SHOCK can kill.
Turn the input power OFF at the weld-
ing power source before installation
or changing drive rolls and/or guides.
• Do not touch electrically live parts.
When inching with the gun trigger, electrode and
drive mechanism are "hot" to work and ground
and could remain energized several seconds
after the gun trigger is released.
Only qualified personnel should perform mainte-
nance work.
------------------------------------------------------------------------
Tools required:
• 1/4" hex key wrench.
Note: Some gun bushings do not require the use of
the thumb screw.
1. Turn power off at the welding power source.
2. Remove the welding wire from the wire drive.
3. Remove the thumb screw from the wire drive.
4. Remove the welding gun from the wire drive.
Figure B.5
POWER MIG
®
256
5. Loosen the socket head cap screw that holds the
connector bar against the gun bushing.
Important: Do not attempt to completely
remove the socket head cap screw.
6. Remove the outer wire guide, and push the gun
bushing out of the wire drive. Because of the pre-
cision fit, light tapping may be required to remove
the gun bushing.
7. Disconnect the shielding gas hose from the gun
bushing, if required.
8. Connect the shielding gas hose to the new gun
bushing, if required.
9. Rotate the gun bushing until the thumb screw hole
aligns with the thumb screw hole in the feed plate.
Slide the gun receiver bushing into the wire drive
and verify the thumb screw holes are aligned.
10. Tighten the socket head cap screw.
11. Insert the welding gun into the gun bushing and
tighten the thumb screw.
WARNING
B-7B-7
OPERATION
MAKING A WELD
1. Check that the electrode polarity is correct for the process
being used, then turn the power switch ON.
2. Set desired arc voltage and wire speed for the particular
electrode wire, material type and thickness, and gas (for
GMAW) being used. Use the Application Chart on the door
inside the wire compartment as a quick reference for some
common welding procedures.
3. Select the desired mode as described in "Description of
Controls” Section.
4. Press the trigger to feed the wire electrode through the
gun and cable and then cut the electrode within
approximately 3/8" (10 mm) of the end of the contact tip
[3/4" (20 mm) Outershield
®
].
NOTE: If set for slow run-in when the trigger is pulled, the
wire feeder feeds wire at low speed regardless of the set wire
feed speed until the welding arc starts or 1 second has
elapsed. This feature enhances starting and makes it easier
to set the stickout. The 1 second limit permits high speed
loading of the gun and cable. To change run-in mode, see
"Run-In Mode" in Description of Controls Section.
5. If welding gas is to be used, turn on the gas supply and set
the required flow rate (typically 25-35 CFH; 12-16
liters/min).
6. When using Innershield electrode, the gas nozzle may be
removed from the insulation on the end of the gun and
replaced with the gasless nozzle. This will give improved
visibility and eliminate the possibility of the gas nozzle
overheating.
7. Connect work cable to metal to be welded. Work clamp
must make good electrical contact to the work. The work
must also be grounded as stated in "Arc Welding Safety
Precautions".
When using an open arc process, it is necessary
to use correct eye, head, and body protection.
------------------------------------------------------------------------
8. Position electrode over joint. End of electrode may
be lightly touching the work.
9. Lower welding helmet, close gun trigger, and begin
welding. Hold the gun so the contact tip to work
distance is about 3/8" (10 mm) [3/4" (20 mm) for
Outershield].
10. To stop welding, release the gun trigger and then
pull the gun away from the work after the arc goes
out.
11. When no more welding is to be done, close valve on
gas cylinder (if used), momentarily operate gun trig-
ger to release gas pressure, and turn off
POWER
MIG
®
256.
AVOIDING WIRE FEEDING
PROBLEMS
Wire feeding problems can be avoided by observing the
following gun handling procedures:
• Do not kink or pull cable around sharp corners.
Keep the gun cable as straight as possible when weld-
ing or loading electrode through cable.
• Do not allow dolly wheels or trucks to run over cables.
Keep cable clean by following maintenance instruc-
tions.
Use only clean, rust-free electrode. The Lincoln elec-
trodes have proper surface lubrication.
Replace contact tip when the arc starts to become
unstable or the contact tip end is fused or deformed.
Keep wire reel spindle brake tension to minimum
required to prevent excess reel over-travel which may
cause wire "loop-offs" from coil.
Use proper drive rolls and wire drive idle roll pressure
for wire size and type being used.
FAN CONTROL
The fan is designed to come on automatically when a
weld arc is established. The fan will stay on for a minimum
of 6 minutes after the weld arc is terminated. The fan will
also stay on when the machineʼs welding and feeding are
disabled during thermostatic over temperature protection.
(See Welding Thermal Overload Protection)
INPUT LINE VOLTAGE PROTECTION
High Line Voltage — If the line voltage exceeds 125% of
rated input voltage, the output will be reduced to the lower
level to protect voltage rating of the capacitor bank.
Low Line Voltage — You may not be able to get
maximum output from the machine if the line voltage is
less than rated input. The unit will continue to weld, but
the output may be less than what is set.
WIRE FEED OVERLOAD PROTECTION
The
POWER MIG
®
256 has solid state overload
protection of the wire drive motor. If the motor becomes
overloaded, the protection circuitry turns off the wire feed
speed weld outputi and gas solenoid. Check for proper
size tip, liner, and drive rolls, for any obstructions or bends
in the gun cable, and any other factors that would impede
the wire feeding.
To resume welding, simply pull the trigger. There is no
circuit breaker to reset, as the protection is done with
reliable solid state electronics.
POWER MIG
®
256
WARNING
B-8
B-8
OPERATION
WELDING THERMAL OVERLOAD
PROTECTION
The POWER MIG
®
256
has built-in protective
thermostats that respond to excessive temperature.
They open the wire feed and welder output circuits if
the machine exceeds the maximum safe operating
temperature because of a frequent overload, or high
ambient temperature plus overload. The thermostats
automatically reset when the temperature reaches a
safe operating level and welding and feeding are
allowed again, when gun is retriggered.
OVERCURRENT PROTECTION
The machine will automatically reduce the output if the
load on the machine exceeds 300 to 320 amperes.
This protects the welding power SCRʼs from excessive
short circuit currents and from exceeding their
temperature rating before the thermostats can react.
WELDING PROCEDURE
INFORMATION
NOTE: See inside cover of machine for additional,
commonly used welding procedure
.
POWER MIG
®
256
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37

Lincoln Electric POWER MIG 256 Manuel utilisateur

Catégorie
Système de soudage
Taper
Manuel utilisateur

dans d''autres langues