2
INSTALLATION INSTRUCTION
FM-31414
314-LED Flush Mount
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. Oct.2023
Fig.4 Switch
Mounting Backplate
Fig.3 Wiring
Fig.1
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
MOUNTING THE FIXTURE (Fig. 1&Fig. 2)
3. Secure the glass assembly to the canopy using Assembly screws(C).
4. Remove the mounting screw (B) from the xture.
5. The lamp can switch between four color temperatures (2700K-3000K-3500K-4000k), which can be adjusted to your preference with the switch in
the canopy (Fig.4).
Note: the switch comes with a detachable cover, remove the cover prior to adjusting the color temperature, reattach the cover after
adjustment is made.
6. Drill holes in the wall aligned with the key holes located in the mounting plate, insert the plastic anchors (D).
7. Secure the mounting plate to the junction box using the screws provided with the junction box. Fasten the back plate to the wall with the plastic
anchors using the wood screws (E) provided.
Note: (i)Using any other non-original-manufacturer provided junction box screw may result in safety issue.
(ii) The side of the mounting plate marked “GND” must face out.
CONNECTING THE WIRES (Fig. 3)
8. Connect the input wires to junction box wires as shown (Fig. 3). Make sure that all wire connectors (A) are secure. If your outlet
box has a GND or bare copper ground wire, connect the ground wire to it. Otherwise, connect the xture’s ground wire directly
to the backplate using the GND screw provided. After wires are connected, tuck them carefully inside the junction box.
COMPLETING THE INSTALLATION
9. Secure the xture to the mounting back plate using the mounting screw (B).
(OPTIONAL) DIMMER WIRING (Fig. 5)
Note: Dimming module (Part# LDS065M010AFE-LO1) is required in order to utilize 0-10V dimming feature
10. To utilize 0-10V dimming feature connect the purple (dim+) and pink or gray (dim-) wires from the dimming module to controller.From the
dimming module connect the black (live) or white (neutral) wires to the power sources from the junction box and the black (output-) and
blue (output+) wires to the xture see (Fig.5) below.
Black or
Smooth
White or
Ribbed
Bare wire
(Ground)
Black
(Hot)
White
(Neutral)
Green or Bare Copper
(Ground)
Fig.2
7 3/4"
5 1/2"
1 3/4" 1 3/8"
Junction
Box
Mounting Backplate
Junction Box Screw
Wire Connector
A
Ground
Wire
Lamp body
Mounting
Screw
B
D
E
Plastic Anchor
Wood Screw
Assembly
Screw ×4
4CCT Switch
4CCT Switch Cap
C
Fig.5 Driver Wiring
Black - Live
White - Neutral
Purple - Dim+
Pink or Gray - Dim- Blue - Output+
Black- Output-
Dimming Module