Modern Forms WS-94614 I-Beam Mode d'emploi

Taper
Mode d'emploi
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
1
INSTALLATION INSTRUCTIONS
I Beam - Wall Sconce
WS-94614 / WS-94620
HARDWARE
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE BEGIN-
NING.
- Read all instructions before installing.
- System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
- When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
- Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or ac-
cessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MAINTENANCE NOTE: Coastal conditions may cause mineral and residue build-up on the xture. We recommend that customers in coastal
areas clean all external surfaces of the xture once every two weeks with a wet cloth.
MISE EN GARDE: Pour éviter tout choc électrique, assurez-vous que le disjoncteur soit mis hors tension avant de commencer.
- Lisez toutes les instructions avant l’installation.
- Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règle-
ments locaux.
- Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
NOTE D’ENTRETIEN: Les conditions côtières peut causer une accumulation de minéraux et de résidue sur le luminaire. Nous recommendons
aux clients qui resident dans les zones côtières de nettoyer toutes les surfaces externes du luminaire une fois toutes les deux semaines avec un
chion humide.
A1 E1D1C1B1
Wire Connector
Qty: 3 pcs
7EAC112201
Wood Screw
Qty: 2 pcs + 1 Extra
7MPF2204J2
Ø4x22mm
Nickel Plating
Plastic Anchor
Qty: 2 pcs + 1 Extra
7TDD082401
Junction Box Screw
Qty: 2 pcs + 1 Extra
7MPF0415C2
#8-32x9/16” SS
Mounting Screw
Qty: 1 Extra
7MPF0409S3
5/32-32x3/8”
Nickel plating
Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program.
2
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES Fig. 2
3. Remove the mounting screw (C1) from the mounting xture.
4. Drill a hole in the wall aligned with the key-hole located in the mounting plate, insert the plastic anchor (D1) to the wall.
5. Connect the driver input/output wires to junction box wires as shown (Fig. 2). Make sure that all wire connectors (A1) are secure. If your out-
let box has a green or bare copper ground wire, connect the xtures ground wire to it. Otherwise, connect the xture’s ground wire directly
to the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
NOTE: This xture requires driver to be recessed within the junction box.
MOUNTING THE FIXTUREFig. 1
6. Secure the mounting plate to the junction box using junction box screws (B1). Fasten the mounting plate to the wall using
the wood screw (E1).
NOTE: The side of the mounting back plate marked “GND” must face out.
7. Place the xture on the mounting plate, and secure it with mounting screw (C1).
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare
Copper
(Ground)
Fig.2 Wiring
Back Plate Dimensions
FIG.1
E1
D1
A1
B1
C1
Wood Screw
Plastic Anchor
Wire Connector
Junction Box Screw
Mounting Screw
Mounting Plate
13 1/4”
1 3/4”
9 1/2”
1 3/8”
4 1/8”
Fixture
Driver
Junction Box
INSTALLATION INSTRUCTIONS
I Beam - Wall Sconce
WS-94614 / WS-94620
  • Page 1 1
  • Page 2 2

Modern Forms WS-94614 I-Beam Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues