Genie Company 6072H-BV Le manuel du propriétaire

Catégorie
Porte de garage
Taper
Le manuel du propriétaire
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER
HOMEOWNER: SAVE THIS MANUAL FOR FUTURE REFERENCE
RESIDENTIAL WALL MOUNT OPENER
INSTALLATION, PROGRAMMING, OPERATION,
TROUBLESHOOTING & MAINTENANCE MANUAL
39947504458, 10/2019
SERIAL NUMBER DECAL iDCM SERIAL NUMBER DECAL
Pour réduire le risque de blessures corporelles ou de dégâts matériels, utilisez cet ouvre-porte uniquement avec
une porte sectionnelle résidentielle munie de ressorts de torsion avant.
AVERTISSEMENT
!
To reduce the risk of injury to persons or damage to property, use this opener only
with a residential sectional door with front torsion springs.
WARNING
!
DO NOT use photocells from other manufacturers or openers with this opener.
©2019 GMI Holdings, Inc d/b/a The Genie Company, the Genie logo, Intellicode, Aladdin Connect, Safe-T-Reverse, SmartSet, Sure-Lock, Door Detect, and Safe-T-Beam, are trademarks
of The Genie Company. All other trademarks are property of their rightful owners. Consistent with our policy of continuing product improvements, we reserve the right to change
product specications without prior notice or obligations. HomeLink is a registered trademark of Gentex Corporation. Car2U is a registered trademark of Lear Corporation. Bluetooth is a
registered trademark of SIG.
Standard & Safety Features:
.................................................................................................................1
Safety & General Information:
Introduction .......................................................................................2
Safety Notications ..........................................................................2
Important Installation Instructions ............................................3
Opener Installation:
Pre-Installation Considerations ...................................................4
Pre-Installation Permanent Input Wiring .................................5
Installing Cable Keepers ................................................................6
Installing Opener ..........................................................................7-9
Installing Door Lock .......................................................................10
Wire Opener, Install & Wire Accessories:
Wire Door Lock ................................................................................11
Install And Wire Safe-T-Beam® ...................................................12
Install Wireless Wall Console .......................................................13
Install Led Light Fixture ................................................................13
Install And Wire Optional Wired Wall Console .....................14
Install And Wire Optional External Interlock ........................14
Install Bottom Cover ......................................................................14
Apply Power To Opener ...............................................................15
Programming Opener And Accessories:
Introduction .....................................................................................16
Adjusting For Drum Selection ...................................................17
Setting Down Limit ........................................................................18
Setting Up Limit ..............................................................................19
Setting Force Control And Contact Reverse .........................20
Programming Additional Remote Controls ..........................21
Programming Accessories:
Wireless Keypad* ............................................................................22
Programming Vehicle Controls* ........................................23-24
Programming Aladdin Connect® .......................................25-26
Special Installation Information:
Changing Force Settings .............................................................27
Clearing Remote/Accessory Memory .....................................28
Locating Safe-T-Beam® (multiple doors) ...............................29
Safe-T-Beam® Troubleshooting .................................................29
Installing Battery Back Up ...........................................................30
Adding And Programming Additional Accessories ...........31
Maintenance:
Important Safety Instructions ....................................................32
Regular Maintenance Schedule ................................................33
Door Inspection & Maintenance ...............................................33
Remote Battery Replacement ....................................................33
Troubleshooting & LED Signals......................................34-36
Replacement Parts ............................................................... 37-39
DASMA Information ............................................................40-41
INDEX SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
FCC Part 15.21 Statement:
Changes or modications not expressly
approved by the party responsible for
compliance could void the user’s authority to
operate the equipment.
FCC / IC Statement:
This device complies with FCC Part 15 and
Industry Canada licence-exempt RSS
standard(s). Operation is subject to the
following two conditions: (1) this device
may not cause harmful interference, and
(2) this device must accept any interference
received, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR
d’Industrie Canada applicables aux appareils
radio exempts de licence. Lexploitation est
autorisée aux deux conditions suivantes : (1)
l’appareil ne doit pas produire de brouillage,
et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre
le fonctionnement.
* Abbreviated versions. See instructions that accompany
ACCESSORY or VEHICLE OWNERS MANUAL for full details,
WARNINGS, CAUTIONS and instructions.
1
2
3
4
5
6
7
8
9
10
Section Information Page
For patent info visit www.geniecompany.com/patents
1. Safe-T-Beam® (STB) Non-Contact Reversing System:
t Places an infrared beam across the door opening.
t Only aects the DOWN travel of the door.
t Stops an open door from closing or reverses a door while in the down travel.
t Reversing system can be overridden with constant pressure on the wired wall console only.
t The door will stop and reverse to the full open position if beam is obstructed.
t Self-diagnostic LEDs on STBs and Powerhead alert to operational issues (See Locating Safe-T-Beam® (for multiple doors) &
Troubleshooting section in this manual for more information).
2. Contact Reversing System:
t Force control automatically reverses a closing door upon contact with an obstruction.
3. Manual Emergency Release pull handle & cord:
t Manually releases door from door opener. Used during a power failure or other emergency to allow manual opening and closing
of the door.
4. Automatic Bluetooth® LED Light Fixture:
t Lighting Fixture turns ON when door is activated and automatically turns OFF 4 minutes later.
t Can be activated/deactivated manually from the wall console.
5. Integrated Aladdin Connect™ :
t Available with select models, allows operation of the garage door opener with a secure mobile device application (app) from
Aladdin Connect™.
6. Wireless Wall Console:
t Wireless Wall Console operates door opener from inside garage with an open/close button.
t Manual light control and override.
t OPEN/CLOSE Delay button. Adds an operation delay. Press once for 10 seconds, twice for 20 seconds, three times for 30 seconds.
7. Intellicode® Encryption, Factory Programmed Remote(s) :
t An encryption system that enhances the security of the door opener by continuously changing the access code each time the
remote is used.
t Factory programmed remote control(s) included with this opener.
Not Shown- Battery Backup (Included on select models) :
t Mounts to bottom of opener and provides power for opener operation during power outages.
1
3
6
7
5
42
Vehicle
Compatible
STANDARD AND SAFETY FEATURES
1
1
2
IMPORTANT SAFETY INSTRUCTIONS
OVERVIEW OF POTENTIAL HAZARDS
READ THIS SAFETY INFORMATION
Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension,
and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do
not understand the information presented, call your nearest trained door system technician or visit our website at www.geniecompany.com
CONVENTIONS USED IN THESE INSTRUCTIONS
The following safety alert symbol and signal words are used throughout this manual to call attention to and identify dierent levels of hazards and special
instructions.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert
symbol and the word
“DANGER”, “WARNING”,
or
CAUTION”.
t
DANGER
indicates an imminently hazardous situation which, if NOT avoided, will result in death or serious injury.
t
WARNING
indicates a potentially hazardous situation which, if NOT avoided, could result in death or serious injury.
t
CAUTION
indicates a potentially hazardous situation which, if NOT avoided, may result in injury or property damage.
t
The word
NOTE
i
s used to indicate important steps to be followed or important considerations.
Tous les messages concernant la sécurité seront indiqués après un symbole d’alerte de la sécurité et l’une des mentions suivantes “DANGER”,
AVERTISSEMENT” ou “MISE EN GARDE”.
t DANGER signale une situation dangereuse imminente qui, si elle n’est pas évitée, risque dentraîner des blessures graves, voire mortelles.
t AVERTISSEMENT signale une situation potentiellement dangereuse qui, si elle n’est pas évitée, risque dentraîner la mort ou des blessures
graves.
t MISE EN GARDE signale une situation potentiellement dangereuse qui, si elle n’est pas évitée, risque dentraîner des blessures ou des
dommages matériels.
t Le terme REMARQUE est utilisé pour signaler les étapes importantes à suivre ou d’importants éléments à prendre en considération.
IMPORTANTES CONSIGNES DE SÉCURITÉ
DANGER POTENTIEL EFFET PRÉVENTION
PORTE EN MOUVEMENT AVERTISSEMENT
Pourrait entraîner des blessures
graves voire la mort
Utiliser uniquement si la porte est en vue et libre de tout obstacle.
Ne laisser personne se tenir dans l’ouverture de la porte pendant
qu’elle est en mouvement.
Ne pas permettre aux enfants de jouer avec l’opérateur de la porte.
Ne pas modier la commande de l’opérateur à contact momentané
à moins qu’un moyen d’inversion externe soit installé.
Ne pas faire fonctionner une porte qui bloque ou dont le ressort
est cassé.
CHOC ÉLECTRIQUE AVERTISSEMENT
Pourrait entraîner des blessures
graves voire la mort
Couper le courant avant d’enlever le couvercle de l’opérateur.
Lorsque le couvercle doit être remplacé, s’assurer que les ls ne sont
ni coincés ni près des pièces mobiles.
Lopérateur doit être correctement mis à la terre.
TENSION ÉLEVÉE RESSORT AVERTISSEMENT
Pourrait entraîner des blessures
graves voire la mort
Ne pas essayer d’enlever, réparer ni ajuster les ressorts ou toute
autre pièce à laquelle le ressort de la porte est attaché, y compris
blocs de bois, supports en acier, câbles ou autres articles
semblables.
Les réparations et les réglages doivent être eectués par technicien
qualié qui se sert d’outils appropriés et qui respecte les
instructions.
!
!
!
POTENTIAL HAZARD EFFECT PREVENTION
MOVING DOOR WARNING
Could result in Serious
Injury of Death
Do Not operate unless the doorway is in sight and free of
obstructions. Keep people clear of opening while door is moving.
Do Not allow children to play with the door opener.
Do Not change opener control to momentary contact unless an
external reversing means is installed.
Do Not operate a door that jambs or one that has a broken spring.
ELECTRICAL SHOCK WARNING
Could cause Serious
Injury or Death
Turn o electrical power before removing opener cover.
When replacing the cover, make sure wires are not pinched or near
moving parts.
Opener must be electrically grounded.
HIGH SPRING TENSION WARNING
Could cause Serious
Injury or Death
Do Not try to remove, repair or adjust springs or anything to which
door spring parts are fastened such as wood block, steel brackets,
cables or any other structure or like item.
Repairs and adjustments must be made by a trained service
representative using proper tools and instructions.
!
!
!
SAFETY NOTIFICATIONS & INSTRUCTIONS
2
3
IMPORTANT INSTALLATION INSTRUCTIONS
IMPORTANTES INSTRUCTIONS D’INSTALLATION
WARNING
!
Opener is equipped with grounded electrical plug for
your protection, and only ts grounded electrical
outlets. DO NOT alter plug in any way! If you have no
grounded outlets, have one installed by a licensed
electrician. Opener must be properly grounded to prevent
personal injury and equipment damage. NEVER USE AN
EXTENSION CORD! Check local building codes for any
requirement that you must have a permanent hard-wired
connection. Permanent hard-wired connections must be
performed by a licensed electrician using proper tools and
instructions.
AVERTISSEMENT
!
Lopérateur, qui est équipé d’une prise électrique mise à la terre
pour votre protection est compatible uniquement avec des
prises électriques mises à la terre. NE PAS modier la che dune
quelconque manière. Si vous n’avez pas de prises mises à la terre,
faites-en installer par un électricien agréé. Lopérateur doit être
correctement mis à la terre pour éviter les blessures corporelles et
des dommages matériels. NE JAMAIS UTILISER DE RALLONGE!
Vériez les codes locaux des bâtiments pour connexions câblées
permanente. Les connexions câblées permanentes doivent
être eectuées par un électricien agréé qui se servira d’outils
appropriés et respectera les consignes.
WARNING
!
AVERTISSEMENT
!
t READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an
instruction, call The Genie® Company.
t DO NOT install opener on an improperly balanced door. An improperly balanced door could cause severe injury. Repairs and
adjustments to cables, spring assembly and other hardware must be made by a trained service person using proper tools and
instructions.
t Remove all ropes, and disable all locks connected to the door before installing opener.
t Where possible, install the door opener 7 feet or more above the oor. For products having an emergency release, mount the
emergency release within reach, but at least 6 feet above the oor and avoiding contact with vehicles to avoid accidental release.
t DO NOT connect the opener to the source of power until instructed to do so.
t Locate the Wall Control: (a) within sight of the door, (b) at a minimum height of 1.53 m (5 ft) above oors, landings, steps or any other
adjacent walking surface so small children are not able to reach it, and (c) away from all moving parts of the door.
t Install the entrapment WARNING label next to the wall button or console, in a prominent location. Install the emergency release
handle on the emergency release cord.
t The opener must reverse when the door contacts a 1-1/2 inch high object on the oor at the center of the doorway. This is about the
size of a 2” x 4” board laid at.
TO REDUCE THE RISK OF SEVERE INJURY OR DEATH
READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not
understand an instruction, call The Genie® Company.
t NE PAS installer l’opérateur sur une porte mal équilibrée. Celle-ci pourrait entraîner de graves blessures. Les réparations et les réglages
des câbles, ensembles de ressort ou tout autre article de quincaillerie doivent être eectués par un professionnel qui se sert d’outils
appropriés et qui respecte les instructions.
t Enlever toutes les cordes et désactiver toutes les verrous de la porte avant l’installer l’opérateur.
t Dans la mesure du possible, installer l’ouvre-porte à 2,1 m ou plus au-dessus du sol. Pour les produits dotés d’un cordon de
déclenchement d’urgence, installer le déclenchement d’urgence mais au moins à 1,8 m au-dessus du sol en évitant tout contact avec
les véhicules pour éviter quils ne soient déclenchés accidentellement. NE PAS connecter l’opérateur à la source d’alimentation tant que
l’instruction n’est pas donnée.
t Installez le bouton de commande a) à un endroit que l’on peut voir de l’embrasure de la porte; b) à une hauteur minimale de 1,53 m (5
pi) du sol — an que les jeunes enfants ne puissent pas l’atteindre ; et c) à l’écart des
t Pièces mobiles de la porte.
t Placer l’étiquette d’AVERTISSEMENT en cas de coinçage à proximité du bouton mural ou de la console de manière à ce quelle soit bien
en évidence. Installer la poignée du cordon de déclenchement d’urgence.
t Lopérateur doit s’inverser lorsque la porte entre en contact avec un objet d’une hauteur de 3,8 cm placé sur le sol, au centre de
l’ouverture de la porte. Ceci équivaut environ à une planche de 5 x 10 cm posée à plat sur le sol.
POUR RÉDUIRE LES RISQUES DE BLESSURES GRAVES
VOIRE MORTELLES
LIRE ET SUIVRE ATTENTIVEMENT TOUTES LES INSTRUCTIONS D’INSTALLATION ET DE FONCTIONNEMENT AINSI QUE TOUTES LES
CONSIGNES DE SÉCURITÉ. Si vous avez des questions ou si vous ne comprenez pas une instruction, veuillez contacter directement The
Genie® Company.
4
PRE-INSTALLATION CONSIDERATIONS
AX
D
B
C
Critical Measurements:
This opener can be installed left or right handed. Critical measurements must be taken to ensure this opener will t the intended
door.
This opener will directly couple onto torsion shafts, solid or tubular, of 1 inch in diameter with or without a keyway. (X)
Measure the distance between the torsion bar centerline to the wall. This dimension must be between 2-1/2” and 6”. (A)
The torsion bar shaft must protrude no less than 2-1/4” from bearing plate. (B)
A standard 115 VAC grounded electrical outlet will be required within 5 feet of the bottom of the opener.
Torsion bar centerline to the ceiling must be at least 2-1/4” for clearance. (C) Note: Headroom required is less than smallest standard
drum (400.8).
End of torsion shaft to side wall clearance must be at least 7 in. for clearance (D)
SIDE VIEW
Compatibility Considerations:
FIG. A
Door Inspection:
If the intended door meets the above requirements, inspect the door for proper balance and general
condition.
t Raise and lower the door manually. Door should move freely and smoothly.
t Raise door manually about 3’ to 4’ feet from oor and let go.
Door should remain stationary or slowly
drift closed. FIG.A.
If door opens or closes rapidly, CONTACT A TRAINED DOOR SYSTEM TECHNICIAN to have your door springs
serviced.
t Disable or remove all locks and ropes attached to the door.
t Monitor the end of the torsion bar while the door is raised and lowered. It is important that there is no
noticeable movement up and down or side to side, if there is, CONTACT A TRAINED DOOR SYSTEM
TECHNICIAN, otherwise opener reliability will be signicantly reduced.
FRONT VIEW
WARNING
Garage door hardware (springs, cables, brackets, pulleys, etc.) are under
extreme pressure and tension.
DO NOT attempt to repair or adjust door springs or any hardware, and DO NOT
OPERATE garage door automatically or manually if door is improperly
balanced or springs are broken.
CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.
AVERTISSEMENT
La quincaillerie de la porte de garage (ressorts, câbles, supports, poulies, etc.)
sont sous des pressions et des tensions extrêmes.
NE PAS réparer ni régler les ressorts de la porte ou toute autre pièce de
quincaillerie et NE PAS ACTIONNER la porte manuellement ou
automatiquement si elle n’est pas correctement équilibrée ou si des ressorts
sont cassés.
CONTACTEZ UN TECHNICIEN SPÉCIALISÉ EN SYSTÈME DE PORTES
! !
The Genie® Residential Wall Mount opener is intended for use on:
t Standard lift up to 14 feet tall, using industry standard APCO 400.8 , 400.12 and 5250.18 drums or equivalent.
t Hi-lift sectional doors up to 14 feet tall and 84 inches maximum of high lift using industry standard APCO 400.54 , 5250.54 and
500.84 drums or equivalent.
t Vertical lift doors up to 14 feet tall, using industry standard APCO 850.11 and 1100.18 drums or equivalent.
t Doors up to 18 feet wide not to exceed 180 square feet and 850 lbs. balance weight.
t Only doors that use torsion springs with a torsion bar diameter of 1 in. solid or hollow 14 or 16 ga. tubular steel.
t Not compatible with low headroom outside hook-up, i.e. reverse wound drums.
3
NOTE: Alternate mounting kits are available for TorqueMaster® and Indirect Chain Couple. See accessories page for more information.
5
PERMANENT WIRING SHOULD BE COMPLETED BY A TRAINED ELECTRICIAN ONLY:
1. Remove two screws from bottom of cover and remove main opener cover/circuit board assembly.
2. Unplug wire harnesses from main board.
3. Unplug input power cable connector from transformer input.
4. Remove transformer from chassis.
5. Remove strain relief and pull power cable from opener.
6. Install opener per instructions on pages 6 through 9.
7. Cut power cable wires and strip insulation from power cable input harness connector end.
t All wire connections must be made INSIDE CHASSIS and there must be at least 3” of new power supply line wire inside chassis.
t Check local code for the use of conduit or other protective material.
t Conduit, ttings/strain relief, and wire nuts are not provided.
8. Install 1/2in. NPT or other suitable connector into chassis. (Adhere to local electrical code(s) and regulations)
9. Connect permanent power input cable to harness wires using approved connectors or wire nuts (Adhere to local electrical
code(s) and regulations)
10. Install ground connector to permanent power cable ground wire.
11. Install ground screw and power cable ground onto chassis.
12. Plug power input harness into transformer harness.
13. Install transformer.
14. Ensure input power cable and connections do not interfere with internal moving components.
15. Plug all harnesses into main control board and install cover assembly.
16. DO NOT APPLY POWER AT THIS TIME.
17. Continue installation starting on page 10.
If a 115V power outlet is not available within 5 feet from bottom of the opener when mounted to door, as an
option the Alternate Low Voltage Power Kit may be used (See section 9).
This task should be performed prior to mounting opener. Fully read and understand the instructions that
accompany the kit before proceeding.
PRE-INSTALLATION CONSIDERATIONS (INPUT POWER WIRING OPTIONS)
Remove
from
chassis
Wire Nut
Connections
External
power cable
Strain Relief
Cable Connector
Power Input
Harness
6
1. Carefully inspect the counterbalance lift cables on the door. If they are worn, frayed or broken, contact a qualied door service
company to replace the counterbalance lift cables before installing the cable keepers.
2. Push spacer onto the shaft between the short stem track roller and the bottom corner bracket. Use an additional spacer if
needed to achieve a minimum of 1/2” clearance.
3. If there is less than 1/2” clearance, loosen the lag screws attaching the track to the wall and adjust the track for the 1/2
clearance. Re-tighten the lag screws.
4. Position the right hand (black) cable keeper assembly directly above the garage door bottom corner bracket.
5. The cable keeper assembly must extend 1/8” past the end of the door section. Ensure there is no more than 4-1/2” from the
bottom edge of the door to bottom of cable keeper.
6. IMPORTANT: RIGHT AND LEFT HAND IS ALWAYS DETERMINED FROM INSIDE THE BUILDING LOOKING OUT.
7. Fasten the cable keeper assembly with (2) 1/4” - 22 x 11/16” self drilling screws (wood doors will use (2) 1/4” x 1” lag screws).
Once the cable keeper assembly is secured to the bottom section, place the plastic sleeve over the counterbalance lift cable and
then rotate the cable keeper arm upward and attach it to the plastic sleeve.
8. Repeat the same process for the left hand (Red) cable keeper assembly.
NOTE: It is recommended that wood doors be pre-drilled with 1/8” pilot holes prior to fastening.
IMPORTANT NOTE: Operate door manually full open to full close and watch keeper to ensure that it does not contact door track.
Adjust as necessary.
Bottom Corner Bracket
Spacer
Shaft
Track Roller
1/8”
1/2” Min
4-1/2” Max
FLOOR
Cable Keeper
Assembly
Cable Keeper Arm
(2) 1/4” -20 x 11/16”
Self Drilling Screws
Counterbalance
lift cable
Cable
keeper arm
Cable keeper
assembly
installed
Plastic
sleeve
Plastic
sleeve
Counterbalance
lift cable
WARNING
Operating a door with frayed or broken counterbalance lift
cables can result in severe or fatal injury.
Contact a qualied door service company to replace frayed
or broken cables before installing cable keepers.
!AVERTISSEMENT
Faire fonctionner une porte avec des câbles de levage à
contrepoids elochés ou cassés peut entraîner des blessures
graves, voire mortelles.
Contactez une société qualiée en réparations de portes pour
remplacer les câbles elochés ou cassés avant d’installer des
protège-câbles.
!
WARNING
Do not attempt to loosen or remove bottom corner brackets.
They are under extreme spring tension and can cause
severe or fatal injury.
!AVERTISSEMENT
N’essayez pas de desserrer ou de retirer les supports en
cornière inférieurs. Ils sont soumis à une tension de ressort ex-
trême et peuvent causer des blessures graves, voire mortelles.
!
INSTALLING CABLE KEEPERS
7
1) CLOSE DOOR.
2) Remove bolt and lock washer (A) from powerhead chassis and loosely install mounting bracket from kit
bag on desired side of powerhead. (Right Hand mount shown)
NOTE: Bracket can be mounted to opener on either side depending on mounting requirements.
3) Slide coupler (1-1/4” end) onto opener output shaft until it fully seats. (See Coupler Cross Section detail
below)
4) Tighten 3 inner set screws on coupler nger tight against opener output shaft.
NOTE: The coupler must be installed onto the opener output shaft until the coupler seats completely to the recess
inside coupler.
NOTE: Opener MUST be mounted to garage framing material. DO NOT install to particle board or
drywall.
NOTE: Alternate installation method: If dimension D (page 4) is less than 8”, install coupler onto door
shaft rst.
INSTALLING THE OPENER
Coupler Cross Section
Opener Output
Shaft - 1-1/4”
Door Shaft - 1”
A
Opener
Output
Shaft
Opener
Mounting
Bracket
7/16”
SOCKET
8
5) Mount opener to door shaft.
If the door shaft is NOT keyed, slide opener assembly onto door shaft and tighten setscrews nger tight.
If the door shaft IS keyed, insert provided key into either keyway. Pull emergency release cable at the bottom
of the opener to allow free rotation of the output shaft to clock” the keyways together.
Tighten set screws onto door shaft nger tight.
NOTE: The mounting of this opener to the door shaft is designed so the door shaft will slide through the coupler
and enter the hollow output shaft of the opener up to 3 -3/8” (there is a stop pin located in the center of the
opener output shaft).
INSTALLING THE OPENER (CONT’)
DOOR
DOOR TORSION SHAFT
CABLE DRUM
RELEASE CABLE
SOLID OR HOLLOW
DOOR SHAFT NO KEY SOLID KEYED
DOOR SHAFT
OPENER REMOVED FOR CLARITY
RIGHT HAND INSTALL SHOWN
Bracket can be
mounted to
opener on either
side depending
on mounting
requirements.
9
NOTE: Opener MUST be mounted to garage framing material. DO NOT install to particle board or
drywall.
The instructions above are provided using standard wood framing and bracing. Additional bracing may be
required for this installation.
Hardware for masonry or steel construction is not provided.
Level &
Square
Opener
6) Mount opener to wall.
Level and square opener. NOTE: Vertical lift openers will not be level.
Mark mounting bracket hole position, pre-drill a 3/16” pilot hole and install lag screw and fully tighten.
Add 1 full turn to hollow tube or 1/2 turn for solid shaft on each coupler set screw in 1/4 turn increments after
contacting door and opener shaft surfaces. DO NOT tighten set screws into an empty keyway.
Leave at least a 1/4” gap between coupler and door shaft bearing.
Tighten mounting bracket bolt to opener.
Pull emergency release cable and manually operate door to inspect for binding.
Tie RED emergency release cord to cable loop and tie release handle to cord approximately 5 feet from oor.
INSTALLING THE OPENER (CONT’)
At least
1/4” Gap
7/16”
WRENCH
PRO TIP: Use 3/8” - 8 point socket and
ratchet to secure square coupler bolts in
tight clearance situations.
7/16”
SOCKET
3/16”
Bit
NOTE: Ensure all COUPLER BOLTS are secured prior to tightening mounting bracket bolt.
10
Door lock prevents manual door operation and is important for garage security
Door lock should be installed no more than 10 feet away on the opener side of the door if
possible.
1. Mount door lock onto door track above a roller on the second or third door panel from the oor.
If mounting position does not line up with pre-punched door lock bar cutouts as shown below:
t Remove template from the back page of the owners manual.
t Apply template to the door track where the center 7/16” hole is approximately 3 inches above the door
roller on the 2nd or 3rd door panel.
t Drill two 9/32” holes for mounting and one 7/16” hole if using template. De-burr holes if required.
2. Position door lock and install two 1/4” X 9/16” track bolts and nuts. Install track bolt on inside of door track
facing outward.
9/32”
7/16”
Bit
INSTALLING THE DOOR LOCK
Approx. 3”
7/16”
SOCKET
11
1. Plug door lock harness into the LOCK plug on bottom of opener. Insert plug in correct direction (SEE INSET)
2. Run wire down the wall to the DOOR LOCK and secure with supplied wire staples. NOTE that DOOR LOCK
wires are polarity sensitive.
3. Cut o excess wire, strip 1/4” of insulation and attach to bottom connectors on DOOR LOCK.
4. Install WHITE wire to W terminal and STRIPED wire to B/W terminal.
Wire Door Lock
WIRE THE OPENER
ALL WIRE CONNECTIONS LOCATED AT BOTTOM OF OPENER
4
Door Lock Plug
Door Lock Wire Connections
12
1. Position Safe-T-Beam® (STB) Transmitter and Receiver on each side of garage door 5"- 6" above oor. Face
the lenses towards each other.
2. Mark bracket mounting holes; drill 3/32" pilot holes and secure with 1/4" x 1-1/4" lag screws (provided) into
wood. If mounting into concrete or block, other fasteners are required and are available at leading retail
stores.
3. Route 2 lengths of supplied wire from powerhead, down to one sensor and along the header and down the
side of the door to the other sensor. Secure the wire to the walls using the insulated staples.
4. On the powerhead: Remove 1/4" insulation from both sets of white and striped wire. Twist two white wires
together. Using a small at head screwdriver, press in the orange tab at one STB terminal and insert the
wires. Twist the two striped wires together and insert into the other STB terminal. NOTE that STB wires are
not polarity sensitive.
5. At each sensor, remove 1/4" insulation from the white and striped wires and secure in each screw terminal.
6” max
5” min
above oor
6” max
5” min
above oor
Floor mount option
PHOTOCELL (STB)
PHOTOCELL (STB)
Wall mount
Wall mount
Transmitter/Receiver
To powerhead
Install and Wire Safe-T-Beams® (STB)
WIRE THE OPENER (CONT’)
13
Install Bluetooth® Light Fixture
Install Wireless Wall Console
FINISHING THE INSTALLATION
1. Determine mounting location within 30 feet of opener.
2. Pre-drill 3/32” holes for mounting screws, or 3/16” if using drywall anchors (supplied) if needed. 7-1/2 in.
inches apart.
3. Install supplied screws leaving an 1/8” gap for mounting.
4. Route power cord through cutouts in ange and plug
light into a standard 115V outlet. Secure excess wire
under light housing.
5. Align LIGHT FIXTURE mounting holes with screws and
turn light assembly to lock into place.
1. Determine mounting location for wireless wall console.
2. Mount console no less than 5 feet above oor to prevent small children
from activating opener.
3. Pre-drill 3/32” holes for mounting screws, or 3/16” if using drywall anchors
(supplied) if needed.
4. Install bottom screw leaving a 1/8” gap.
5. Slide console onto screw and down slightly to lock in place.
6. Remove upper battery door and remove protective tab and batteries.
7. Install top screw to secure console to the wall.
8. Install batteries and battery door.
9. Install warning decal in the same area as wireless wall console.
Open cover and remove
battery tab before
programming
Lower mounting slot
AAA
AAA
Mounting
Screws
Drywall
Anchors
1. DOOR Button - Runs garage door opener.
2. DELAY Button - Adds a 10+ second delay for door operation. Press the delay button and door
will automatically operate after set delay. Can be activated up to 3 times for a 10, 22 or 30
second delay.
3. LIGHT Button - Overrides the automatic timed light function of the garage door opener.
1
2
3
Wall Console Operation
7-1/2 in.
LIGHT FIXTURE INCLUDED WITH OPENER:
1. Power up Wall Mount Opener.
2. Power LIGHT FIXTURE.
Light will automatically pair when opener is powered up.
3. LIGHT FIXTURE will ash and beep briey.
4. LIGHT FIXTURE will ash again indicating that it is now paired to
the opener.
Wireless Wall Console will automatically pair when opener is powered up.
1. Wireless Wall Console is now paired to opener and will operate as normal.
14
Install and Wire Basic Wall Console (Hardwired) - Optional
1. Route supplied wire from powerhead to the desired location for the hardwired wall control. Secure wire with
insulated staples.
2. On the powerhead: Remove 1/4" insulation from white and striped wire. Using a small at head screwdriver,
press in the orange tab and insert the white wire into BWC WHITE terminal and the striped wire into BWC
BLACK terminal.
3. At the wall console end of the wire, remove 1/4" insulation from the white and striped wires and secure the
white wire to the "W" terminal and the striped wire to the "B/W" terminal as shown.
4. Mark the wall console mounting holes, drill 3/32" pilot holes and mount with #6 x 1-1/4" screws. If mounting
to drywall, anchors will be required (not provided).
B/W W
Wall Console Wires:
Striped Wire to B/W Terminal
White Wire to W Terminal
FINISHING THE INSTALLATION
Install Bottom Cover Onto Opener - OMIT THIS STEP IF INSTALLING BATTERY BACK-UP
1. Remove two screws on the sides of opener.
2. Route wires to the rear of opener to align with slot in rear
of cover.
3. Install cover with screws removed in step 1.
t Main Activation
t Sure-Loc Activation
Locks out all opener
functions (vacation lock)
t Light Override
Install and Wire N/C Interlock-Optional
1. Do not remove factory installed interlock wire unless installing an interlock. This jumper is required for
proper opener operation.
2. Use of any commercially available normally closed (N/C) dry contact interlocks can be used with this
opener. Using a small at head screwdriver, press in the orange tabs at INTER-LOCK terminals and remove
factory installed jumper wire and insert the interlock wires.
B/W W
15
Apply power to opener
CAUTION
DO NOT run opener until travel limits have been set to avoid damage to unit.
!
WARNING
Opener is equipped with grounded electrical plug for your protection, and only ts grounded
electrical outlets. DO NOT alter plug in any way! If you have no grounded outlets, have one
installed by a licensed electrician. Opener must be properly grounded to prevent personal injury
and equipment damage. NEVER USE AN EXTENSION CORD! Check local building codes for any
requirement that you must have a permanent hard-wired connection.
!
AVERTISSEMENT
Lopérateur, qui est équipé d’une prise électrique mise à la terre pour votre protection est compatible
uniquement avec des prises électriques mises à la terre. NE PAS modier la che dune quelconque
manière. Si vous navez pas de prises mises à la terre, faites-en installer par un électricien agréé.
Lopérateur doit être correctement mis à la terre pour éviter les blessures corporelles et des dommages
matériels. NE JAMAIS UTILISER DE RALLONGE! Vériez les codes locaux des bâtiments pour connexions
câblées permanente. Les connexions câblées permanentes doivent être eectuées par un électricien
agréé qui se servira d’outils appropriés et respectera les consignes.
!
NE PAS faire fonctionner l’ouvre-porte au-delà des limites de parcours pour ne pas endommager l’unité.
CAUTION
!
FOR GROUNDED OUTLET CONNECTION:
Plug in the power cord to standard 115 VAC outlet. Coil excess cord and tape or twist tie it to top of powerhead.
DO NOT USE EXTENSION CORDS TO POWER THIS OPENER. Extended power input kits are available.
FINISHING THE INSTALLATION
16
NOTE:
Before programming the opener, check to make sure there are no objects in the garage door opening. DO NOT allow
persons to enter the area of the door while programming and operating.
The following steps list the order of programming the openers functional settings as well as installation of any
accessories that were included with the opener or purchased separately. These steps should be performed in order.
1. Adjust opener speed for drum sizes.
2. Down Travel Limit
3. Up Travel Limit
4. Force Control
5. Contact Reverse test and adjustment
6. Remote Control Programming
7. Remote control(s), Lighting xture and Wireless Wall Console included with this opener are programmed at the
factory. The information provided on these pages should be used if adding additional remote controls, wireless wall
consoles or light xtures.
8. Accessory Installation and/or Programming
9. Program wireless keypad (If applicable)
10. Program built in vehicle remote (If applicable)
11. Program the Integrated Aladdin Connect™ (If applicable)
12. Install Battery Backup (BBU) (If applicable)
NOTE:
Each programming step has a 30 second time limit for completion after the function is initiated. After 30 seconds, both LED’s
will illuminate RED indicating time has expired and the step must be restarted. Restart the step as many times as necessary to
complete the programming.
Long LED
Indicator
Round LED
Indicator
Program/Set
Open Travel
Button
Close Travel
Button
Programming Button Layout Wi-Fi Program Wi-Fi LED
OPENER PROGRAMMING & ACCESSORY INSTALLATIONS
5
NOTE: When opener is activated to close, opener will start and stop slowly in small increments to detect cable
tension then run at normal speed to close. This is normal operation.
17
Drum Selection Settings
Drum selection settings are pre-programmed at the factory for 4” Standard Lift type drums. Drum selection
must be made on doors with Standard or High Lift drums with a diameter greater than 4 inches, and also on
Vertical Lift doors. There are two drum settings available for sectional doors. Please note that door speed may
be aected by door weight, drum type, and balance, along with condition of door components and tracks.
Proper selection of the drum type is important for proper operation of the opener.
TO CHANGE OPENER drum selection:
1. Press and hold the SET/PRGM button on the opener until both LEDs turn BLUE then release.
2. Press the UP button twice.
3. Press PRGM button once.
4. The current setting will now be displayed. (SEE CHART).
5. Press either UP or DOWN buttons to adjust setting (SEE CHART)
6. Press PGRM button once to lock in the selection. LEDs turn BLUE then o.
7. Opener is now ready to set limits.
DRUM SELECTION CHART
DRUM TYPE Long LED Round LED
Standard 4 inch or less diameter drum RED RED
Standard or High Lift greater than 4 inch diameter or Vertical Lift PURPLE PURPLE
BLUE
Press to adjust. See
Chart for selection
Lock selection
X2
12 3
45
Operator drum selection settings must be
adjusted for use on Standard or High Lift
residential doors with drum diameters greater
than 4 inches. Drum selection settings must also
be adjusted for use on residential Vertical Lift
doors.
WARNING
!
Les réglages de sélection du tambour par l’opérateur
doivent être ajustés pour une utilisation sur des portes rés-
identielles à levage régulier ou élevé avec des diamètres de
tambour supérieurs à 4 pouces (10,16 cm). Les réglages de
sélection du tambour doivent également être ajustés pour
une utilisation sur des portes résidentielles à levage vertical.
AVERTISSEMENT
!
ADJUSTING FOR DRUM SELECTION
IMPORTANT NOTICE
IF DRUM SELECTION SETTING IS ALTERED, ALL FOLLOWING STEPS ON PAGES 18 THROUGH 20 MUST BE
PERFORMED TO LOCK IN THE FORCE PROFILE FOR PROPER DOOR OPERATION.
!!
18
WARNING
!
t Make sure doorway is in full view and clear of obstacles and
people to avoid injury or property damage.
t DO NOT operate this unit from the wall control before LIMITS are
set. Severe damage to the opener could occur.
t DO NOT set limits with Battery Backup attached. AC power
MUST be connected to the opener while setting limits for proper
operation.
AVERTISSEMENT
!
t S’assurer que le passage de la porte est visible et dégagé, à savoir
sans obstacles ni personne an d’éviter toute blessure potentielle
ou dommage matériel.
t NE PAS utiliser cette unité avec la console murale avant d’avoir
réglé les LIMITES. Louvre-porte pourrait subir de sérieux
dommages.
t NE PAS xer de limites en mode batterie de secours.
L’alimentation CA DOIT être branchée sur l’ouvre-porte, pendant
le réglage des limites, pour assurer un bon fonctionnement.
NOTE: Door MUST be engaged to the
opener prior to programming. Door should rest
somewhere between full open and closed. DO
NOT START WITH DOOR FULLY OPEN OR CLOSED.
!
1. Press and hold the DOWN arrow button on the
opener for 2-5 seconds.
t The LONG LED will turn BLUE. Release button.
t The LONG LED will then ash BLUE.
2. Press and hold the DOWN arrow button until door
is fully closed.
Use both UP and DOWN buttons to adjust close travel
as necessary.
Door should rest on the oor until the weather strip is
compressed enough to seal along the width of the door.
Damaged doors or uneven oors may not seal properly.
Repair these conditions to achieve a proper seal. DO NOT
compress seal so much that the door will bend or buckle.
3. Press and release the SET/PRGM button
Both LEDs will ash BLUE then go out.
The DOWN limit is now programmed.
Programming DOWN Limit:
Flashing Blue RELEASE
Steady Blue
HOLD
UNTIL
LED
Lights
1-2. Enter Programming Mode
3. Adjust Door Position
4. Lock Programming
Flashing Blue
PRESS
&
RELEASE
PROGRAMMING THE DOWN LIMIT
TO ENGAGE DOOR
TO OPENER:
Pull release cable and
release to retract cable
and engage opener.
IMPORTANT NOTICE
IF DOWN LIMIT SETTING IS ALTERED, ALL FOLLOWING STEPS ON PAGES 19 THROUGH 20 MUST BE
PERFORMED TO LOCK IN THE FORCE PROFILE FOR PROPER DOOR OPERATION.
!!
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Genie Company 6072H-BV Le manuel du propriétaire

Catégorie
Porte de garage
Taper
Le manuel du propriétaire

dans d''autres langues