Pepperl+Fuchs LD28/LV28-LAS-F1-7675 Mode d'emploi

Taper
Mode d'emploi
alle Maße in mm
DimensionsAbmessungen
Technische Daten Technical data
Elektrischer Anschluss Electrical connection Adressen/Addresses
Sicherheitshinweise:
•Vor der Inbetriebnahme Betriebsanleitung lesen
Anschluss, Montage und Einstellung nur durch Fachpersonal
Kein Sicherheitsbauteil gemäß EU-Maschinenrichtlinie
Security Instructions:
Read the operating instructions before attempting commissioning
Installation, connection and adjustments should only be undertaken by specialist personnel
Not a safety component in accordance with the EU Machinery Directive
all dimensions in mm
www.pepperl-fuchs.com
Pepperl+Fuchs GmbH
68301 Mannheim · Germany
Tel. +49 621 776-4411
Fax +49 621 776-27-4411
E-mail: fa-inf[email protected]
Worldwide Headquarters
Pepperl+Fuchs GmbH · Mannheim · Germany
E-mail: fa-inf[email protected]
USA Headquarters
Pepperl+Fuchs Inc. · Twinsburg · USA
E-mail: fa-inf[email protected]
Asia Pacific Headquarters
Pepperl+Fuchs Pte Ltd · Singapore
E-mail: fa-inf[email protected]
Company Registration No. 199003130E
8
Schwalbenschwanz -
aufnahme
Empfindlichkeitseinsteller
LED-Anzeige
Betrieb
Hell-/Dunkel-Schalter
LED-Anzeige
Schaltzustand
LED-Anzeige
Schaltzustand
LED-Anzeige rot
Ausrichthilfe
Sender Empfänger
4
10
M12x1
5
10
88
2521624
66211
ø5
9.6
51.8
25.8
54.3
14.8
Einweg-Lichtschranke
mit Gerätestecker M12 x 1, 5-polig
Thru-beam sensor
with 5-pin, M12 x 1 connector
LD28/LV28-LAS-F1-7675
Einzelkomponenten
Sender LD28-LAS-F1-7675
Empfänger LV28-LAS-F1/82b/105/110
Allgemeine Daten
Betriebsreichweite 0 ... 120 m
Grenzreichweite 150 m
Lichtsender Laserdiode
Lichtart rot, Wechsellicht
Laserkenndaten
Hinweis LASERLICHT , NICHT IN DEN STRAHL BLICKEN
Laserklasse 2
Wellenlänge 650 nm
Strahldivergenz < 4 mrad
Impulsdauer 20 µs
Wiederholrate 25 kHz
max. Puls Energie 18 nJ
Ausrichthilfe LED rot (in Empfänger-Optik)
leuchtet konstant bei Strahlunterbrechung,
blinkt bei Erreichen des Schaltpunktes,
aus bei Erreichen der Funktionsreserve
Lichtfleckdurchmesser ca. 20 mm bei 5 m, ca. 75 mm x 300 mm bei 70 m horizontal zur Gehäuseachse
Öffnungswinkel Sender: 0,23 °
Empfänger: 5 °
Fremdlichtgrenze 50000 Lux
Kenndaten funktionale Sicherheit
MTTFd 540 a
Gebrauchsdauer (TM) 20 a
Diagnosedeckungsgrad (DC) 90 %
Anzeigen/Bedienelemente
Betriebsanzeige LED grün
Funktionsanzeige LED gelb:
1. LED leuchtet konstant: Signal > 2 x Schaltpunkt (Funktionsreserve)
2. LED blinkt: Signal zwischen 1 x Schaltpunkt und 2 x Schaltpunkt
3. LED aus: Signal < Schaltpunkt
Bedienelemente Empfindlichkeitseinsteller (Einstellung bis < 25 % der Betriebsreichweite) , Hell-/Dun-
kelumschalter
Elektrische Daten
Betriebsspannung UB10 ... 30 V DC
Welligkeit 10 %
Leerlaufstrom I0Sender: 55 mA
Empfänger: 40 mA
Eingang
Testeingang Senderabschaltung bei +UB
Ausgang
Vorausfallausgang 1 PNP-Transistor, kurzschlussfest, verpolsicher, offener Kollektor, Umax = 30 V DC,
Imax = 0,2 A
Der Ausgang wird inaktiv, wenn das Signal für etwa 10 s die Funktionsreserve unter-
schritten hat (gelbe und rote LED blinken).
Finden innerhalb dieser Zeit 4 Lichtstrahlungsunterbrechungen statt, wird der Aus-
gang sofort inaktiv.
Schaltungsart hell-/dunkelschaltend, umschaltbar
Signalausgang 1 Gegentaktausgang, kurzschlussfest, verpolgeschützt
Schaltspannung max. 30 V DC
Schaltstrom max. 100 mA
Schaltfrequenz f 1000 Hz
Ansprechzeit 0,5 ms
Umgebungsbedingungen
Umgebungstemperatur -10 ... 50 °C (14 ... 122 °F)
Lagertemperatur -20 ... 75 °C (-4 ... 167 °F)
Mechanische Daten
Gehäusebreite 25,8 mm
Gehäusehöhe 88 mm
Gehäusetiefe 54,3 mm
Schutzart IP67
Anschluss Kunststoffstecker M12 x 1, 5-polig
Material
Gehäuse Kunststoff ABS
Lichtaustritt Kunststoffscheibe
Masse 140 g (Sender und Empfänger)
Normen- und Richtlinienkonformität
Richtlinienkonformität EMV-Richtlinie 2004/108/EG
Normenkonformität
8
Dovetail mount
LED indicator:
operation
LED indicator:
switching state
LED indicator:
switching state
Transmitter Receiver
Sensitivity adjuster
Light/dark switch
LED-indicator red
alignment aid
4
10
M12x1
5
10
88
2521624
66211
ø5
9.6
51.8
25.8
54.3
14.8
08/31/2017
Date:
Option:
3
2
1
4
5
+UB
0 V
Q1
I/O
Q2
Alarm
/110
Sender
Test
1
3
4
5
2
System components
Emitter LD28-LAS-F1-7675
Receiver LV28-LAS-F1/82b/105/110
General specifications
Effective detection range 0 ... 120 m
Threshold detection range 150 m
Light source laser diode
Light type modulated visible red light
Laser nominal ratings
Note LASER LIGHT , DO NOT STARE INTO BEAM
Laser class 2
Wave length 650 nm
Beam divergence < 4 mrad
Pulse length 20 µs
Repetition rate 25 kHz
max. pulse energy 18 nJ
Alignment aid LED red (in receiver lens)
illuminated constantly: beam is interrupted,
flashes: reaching switching point,
off: sufficient stability control
Diameter of the light spot nicht uebersetzt!
Angle of divergence Emitter: 0.23 °
Receiver: 5 °
Ambient light limit 50000 Lux
Functional safety related parameters
MTTFd 540 a
Mission Time (TM) 20 a
Diagnostic Coverage (DC) 90 %
Indicators/operating means
Operation indicator LED green
Function indicator LED yellow:
1. LED lit constantly: signal > 2 x switching point (function reserve)
2. LED flashes: signal between 1 x switching point and 2 x switching point
3. LED off: signal < switching point
Control elements sensitivity adjustment (Adjustment to < 25% of the effective operating range) , Light-
on/dark-on changeover switch
Electrical specifications
Operating voltage UB10 ... 30 V DC
Ripple 10 %
No-load supply current I0Emitter: 55 mA
Receiver: 40 mA
Input
Test input emitter deactivation at +UB
Output
Pre-fault indication output 1 PNP transistor, short-circuit protected, protected from reverse polarity, open collec-
tor, Umax = 30 V DC, Imax = 0.2 A
The output becomes inactive if the signal level has fallen below the function reserve for
approx. 10 s (yellow and red LEDs flash).
If the light beam is interrupted four times during this period, the output immediately
becomes inactive.
Switching type light/dark on, switchable
Signal output 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected
Switching voltage max. 30 V DC
Switching current max. 100 mA
Switching frequency f 1000 Hz
Response time 0.5 ms
Ambient conditions
Ambient temperature -10 ... 50 °C (14 ... 122 °F)
Storage temperature -20 ... 75 °C (-4 ... 167 °F)
Mechanical specifications
Housing width 25.8 mm
Housing height 88 mm
Housing depth 54.3 mm
Degree of protection IP67
Connection 5-pin, M12 x 1 plastic connector
Material
Housing Plastic ABS
Optical face Plastic pane
Mass 140 g (emitter and receiver)
Compliance with standards and direc-
tives
Directive conformity EMC Directive 2004/108/EC
= Hellschaltung
= Dunkelschaltung
= Light on
= Dark on
Option:
3
2
1
4
5
+UB
0 V
Q1
I/O
Q2
Alarm
/110
Emitter
Test
DIN A3 ->
Part. 310277 45-5236
Doc.
Die Bestrahlung kann zu Irritationen gerade bei dunkler Umgebung führen. Nicht auf Menschen richten!
Vorsicht: Laserlicht, nicht in den Strahl blicken!
Wartung und Reparaturen nur von autorisiertem Servicepersonal durchführen lassen!
Das Gerät ist so anzubringen, dass die Warnhinweise deutlich sichtbar und lesbar sind.
Vorsicht: Wenn andere als die hier angegebenen Bedienungs- oder Justiereinrichtungen benutzt oder
andere Verfahrensweisen ausgeführt werden, kann dies zu gefährlicher Strahlungseinwirkung führen.
The irradiation can lead to irritation especially in a dark environment. Do not point at people!
Caution: Do not look into the beam!
Maintenance and repairs should only be carried out by authorized service personnel!
Attach the device so that the warning is clearly visible and readable.
Caution – Use of controls or adjustments or performance of procedures other than those specified her-
ein may result in hazardous radiation exposure.
L’irradiation peut entraîner des irritations dans un environnement sombre.
Ne pas orienter vers les personnes !
Attention : ne pas observer la lumière laser dans le faisceau !
L’entretien et les réparations doivent être réalisés exclusivement par le personnel de service autorisé !
L’appareil doit être installé de manière à ce que les mises en garde soient clairement visibles et lisibles.
Attention : Si d’autres dispositifs de commande ou de réglage sont utilisés que ceux indiqués ici, ou si
d’autres procédures sont exécutées, cela peut entraîner un effet préjudiciable du rayonnement.
LASERLICHT
LASER LIGHT
NICHT IN DEN STRAHL BLICKEN
DO NOT STARE INTO BEAM
LASER KLASSE 2
CLASS 2 LASER PRODUCT
Funktionsbeschreibung
Sicherheitshinweise
Vor der Inbetriebnahme Betriebsanleitung lesen
• Anschluss, Montage und Einstellung nur durch Fachpersonal
Kein Sicherheitsbauteil gemäß EU-Maschinenrichtlinie
Montagehinweise
Der Sensor kann über die Durchgangsbohrungen direkt befestigt werden oder über einen der Haltewinkel
bzw. Klemmkörper (diese sind nicht im Lieferumfang enthalten).
Die Untergrundfläche muss plan sein, um Gehäuseverzug beim Festziehen zu vermeiden. Es empfiehlt
sich, die Mutter mit Federscheiben zu sichern, um einer Dejustierung des Sensors vorzubeugen.
Justage
Nach Anlegen der Betriebsspannung leuchtet die LED grün.
Sender und Empfänger gegenüber ausrichten bis die gelbe LED im Empfänger konstant leuchtet. Durch
Schwenken der Sensoren kann man herausfinden, wann dieser Bereich verlassen wird. Dann blinkt die
gelbe Leuchtanzeige bis sie bei weitern Drehen ausgeht. In der Mitte zwischen beiden Stellungen liegt die
exakte Justierung.
Die gelbe LED im Empfänger leuchtet konstant.
Ausrichthilfe (rote LED)
Zur besseren Ausrichtbarkeit bei großen Reichweiten befindet sich eine 2.LED (rot) im Optikteil des Emp-
fängergerätes:
1)LED leuchtet konstant: Signal < Schaltpunkt
2)LED blinkt: Signal zwischen 1 x Schaltpunkt und 2 x Schaltpunkt
3)LED aus: Signal > 2 x Schaltpunkt (Funktionsreserve)
Reinigung
Wir empfehlen in regelmäßigen Abständen den Lichtaustritt zu reinigen und Verschraubungen, sowie die
Steckverbindungen zu überprüfen.
Function description
Security Instructions
Read the operating instructions before attempting commissioning
Installation, connection and adjustments should only be undertaken by specialist personnel
No safety component in accordance with EU machine guidelines
Mounting instructions
The sensor can be fastened over the through-holes directly or with one of the support angles or clamping
components (this are not contained in the scope of supply).
The base surface must be flat to avoid distorting the housing during mounting. It is advisable to secure the
bolts with washers so that the sensor does not become misaligned.
Adjustment
Connect the sensor to operating voltage, the LED green lights up constantly.
Emitter and receiver align to opposite: Yellow LED (receiver) lights up constantly.
By paining the sensors, both horizontally and vertically, one can determine when the sensor is aligned cor-
rectly. When the yellow LED starts flashing the light beam is on the edge of the useful alignment zone, and
when the Led is off , then there is no alignment. The correct adjustment is with the light beam in the center
of these two extremes in both the horizontal and vertical modes. The yellow LED is permanently on.
Alignment aid (red LED)
For the better adjustment with large ranges a 2.LED (red) is in the optic of the
receiver device:
1)LED lights up constantly: Signal < switching point
2)LED flashes: Signal between 1 x switching point and 2 x switching point
3)LED out: Signal > 2 x switching point (function reserve)
Maintenance
We recommend that you frequently clean the optical surfaces and check the electrical connections and
mechanical fixations.
Laserhinweis Laserklasse 2
Laser notice laser class 2
Consigne laser classe 2