DESCRIPTION
Use the CA-1 when installing a low-profile circular ceiling mounted sensor (such as the DT-355, CI-355, or UT-355 models) in a 4"
square Wiremold V5748-2 j-box on a hard ceiling, or in the opening of a mudring for a drop ceiling. The CA-1 provides a finished look by
filling in the spaces at the corners, and covering the unused holes.
INSTALLATION ON A HARD CEILING
1. Pull wires through the opening in the mounting site.
2. Maneuver the CA-1 over the sensor’s rear housing so that the
CA-1 is flush with the sensor flange.
3. Wire to sensor terminals per sensor instructions.
4. For each of the two small recessed mounting holes on the front
of the sensor flange, insert a screw (provided with the sensor)
through the flange, through the CA-1 mounting hole, and into
the square box.
5. Tighten the screws and snap the front cover onto the sensor.
Rear Housing
4" Square
Wiremold #V5748-2 j-box
Front Cover
Ceiling
Screws
CA-1 Adapter
Sensor Flange
INSTALLATION ON A DROP CEILING
1. Pull sensor wires into the j-box.
2. Attach the mudring to the j-box.
3. Pull sensor wires through the opening in the mudring.
4. Maneuver the CA-1 over the sensor’s rear housing so that the
CA-1 is flush with the sensor flange.
5. Wire to sensor terminals per sensor instructions.
6. For each of the two small recessed mounting holes on the front
of the sensor flange, insert a screw (provided with the sensor)
through the flange, through the CA-1 mounting hole, and into
the holes in the mudring.
7. Tighten the screws and snap the front cover onto the sensor.
4" Square, 2.25" Deep
Junction Box with
Double Gang
Mudring attached
Drop Ceiling
Front
Cover
CA-1 Adapter
Rear Housing
Screws
Sensor Flange
800.879.8585
www.legrand.us/wattstopper
No. 24224 – 09/16 rev. 1
© Copyright 2016 Legrand All Rights Reserved.
© Copyright 2016 Tous droits réservés Legrand.
© Copyright 2016 Legrand Todos los derechos reservados.
Wattstopper warranties its products to be free
of defects in materials and workmanship for a
period of five (5) years. There are no obligations
or liabilities on the part of Wattstopper for
consequential damages arising out of, or in
connection with, the use or performance of this
product or other indirect damages with respect
to loss of property, revenue or profit, or cost of
removal, installation or reinstallation.
Wattstopper garantit que ses produits sont
exempts de défauts de matériaux et de fabrication
pour une période de cinq (5) ans. Wattstopper
ne peut être tenu responsable de tout dommage
consécutif causé par ou lié à l’utilisation ou
à la performance de ce produit ou tout autre
dommage indirect lié à la perte de propriété, de
revenus, ou de profits, ou aux coûts d’enlèvement,
d’installation ou de réinstallation.
Wattstopper garantiza que sus productos
están libres de defectos en materiales y mano
de obra por un período de cinco (5) años. No
existen obligaciones ni responsabilidades por
parte de Wattstopper por daños consecuentes
que se deriven o estén relacionados con el
uso o el rendimiento de este producto u otros
daños indirectos con respecto a la pérdida
de propiedad, renta o ganancias, o al costo
de extracción, instalación o reinstalación.
WARRANTY INFORMATION INFORMATIONS RELATIVES À LA GARANTIE INFORMACIÓN DE LA GARANTÍA
  • Page 1 1
  • Page 2 2

Legrand CI-355 Guide d'installation

Taper
Guide d'installation

dans d''autres langues