1. Package Contents
Thank you for purchasing PLANET Industrial Multi-port
10/100/1000T Gigabit Ethernet Switch, IGS-1600T. In the following
sections, the term “Industrial Ethernet Switch” means the
IGS-1600T.
Open the box of the Industrial Ethernet Switch and carefully
unpack it. The box should contain the following items:
Industrial Ethernet Switch x 1 User’s Manual x 1
DIN-rail Kit RJ45 Dust Caps x 16 Wall-mount Kit
If any of these are missing or damaged, please contact your dealer
immediately; if possible, retain the carton including the original
packing material, and use them again to repack the product in case
there is a need to return it to us for repair.
2.2 LEDDenition:
System
LED Color Function
P1 Green Lights to indicate power input 1 has power.
P2 Green Lights to indicate power input 2 has power.
Fault Red Lights to indicate that AC or DC power has
failed.
Per 10/100/1000BASE-T Port
LED Color Function
1000
LNK/ACT Green
To indicate the link through that port is
successfully established at 1000Mbps.
To indicate that the switch is actively sending
or receiving data over that port.
10/100
LNK/ACT Amber
To indicate the port is successfully established
at 10/100Mbps.
To indicate that the Switch is actively sending
or receiving data over that port.
2.6 GroundingtheDevice
Users MUST complete grounding wired with a power cord adapter
or power supply source should be connected to a socket outlet with
an earthing connection; otherwise, a sudden lightning could cause
fatal damage to the device.
Fault
V1+ V2+
PWR2PWR1
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V , 1.5A max.
AC Input: 24V , 1A max.
1 2 3 4 5 6
Note
EMD (Lightning) DAMAGE IS NOT CONVERED UNDER
WARRANTY.
Note
LES DOMMAGES EMD (éclair) NE SONT PAS PRIS
SOUS GARANTIE.
1. Insert positive and negative DC power wires into contacts 1 and
2 for POWER 1, or contacts 5 and 6 for POWER 2.
Fault
V1+ V2+
PWR2PWR1
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V , 1.5A max.
AC Input: 24V , 1A max.
1 2 3 4 5 6
Wire Range Wire Type FW Torque In-lbs (N.m)
12-24 AWG Str/Sol Cu 25 (0.56)
2. This product is intended to be supplied with a UL-listed power
adapter or power source, rated 24V AC, 50/60Hz min. 1A or
12-48V DC, min. 1.5A, and Tma 75°C (max.).
3. Tighten the wire-clamp screws for preventing the wires from
loosening.
123456
Power 1 Fault Power 2
+ - + -
2.HardwareIntroduction
2.1 SwitchFrontPanel
The front panel of the Industrial Ethernet Switch consists of
Ethernet interfaces and LED indicators.
Front View
IGS-1600T
FaultP2P1
1
3
5
7
2
4
6
8
9
11
13
15
10
12
14
16
ACT
1000 LNK
ACT
10/100 LNK
Figure1: IGS-1600T Front View
2.3 SwitchUpperPanel
The upper panel of the Industrial Ethernet Switch consists of one
terminal block connector within two power input and one relay
output.
Fault
V1+ V2+
PWR2PWR1
Max. Fault Alarm Loading: 24V, 1A
DC Input: 12-48V , 1.5A max.
AC Input: 24V , 1A max.
1 2 3 4 5 6
Figure2: IGS-1600T Top View
2.4 WiringthePowerInputs
The 6-contact terminal block connector on the top panel of
Industrial Ethernet Switch is used for two redundant power
inputs. Please follow the steps below to insert the power wire by
professionals.
Caution
When performing any of the procedures like inserting
the wires or tightening the wire-clamp screws, make
sure the power is OFF to prevent from getting an
electric shock.
Caution
Lorsque vous effectuez l’une des procédures telles que
l’insertion des fils ou le serrage des vis de serrage,
assurez-vous que l’alimentation est coupée pour éviter
tout choc électrique.
Note
1. The power input range is DC 12V ~ 48V and
supports AC 24V.
2. Use one power input when using AC 24V.
2.5 WiringtheFaultAlarmContact
The fault alarm contacts are in the middle of the terminal block
connector as the picture shows below. Inserting the wires, the
Industrial Ethernet Switch will detect the fault status of the power
failure and then forms an open circuit. The following illustration
shows an application example for wiring the fault alarm contacts.
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs
Fault
Insert the wires into the fault alarm contacts
Wire Range Wire Type FW Torque In-lbs (N.m)
12-24 AWG Str/Sol Cu 25 (0.56)
Alarm relay circuit accepts up to 24V AC, 1A.
3.Installation
This section describes the functionalities of the Industrial Ethernet
Switch’s components and guides you to installing it on the DIN rail
and wall. Please read this chapter completely before continuing.
Note
This following pictures show how to install the device.
However, the device in the picture is not IGS-1600T.
3.1 DIN-railMountingInstallation
1
2
3.2 Wall-mountPlateMounting
Mount on product or wall (Screw size and quantity: 4mm (L),
3mm (dia.) and 4pcs); DIN-rail mount on product (Screw size and
quantity: 4mm (L), 3mm (dia.) and 3pcs)
- 9 -
- 10 -
- 11 -
- 12 - - 13 - - 14 -
4.3 SideWall-mountPlateMounting
Caution
You must use the screws supplied with the wall-
mounting brackets. Damage caused to the parts by
using incorrect screws would invalidate your warranty.
Attention
Vous devez utiliser les vis fournies avec les supports
muraux. Les dommages causés aux pièces par
l’utilisation de vis incorrectes invalideraient votre
garantie.
Dimensions
(W x D x H) 66 x 107 x 152 mm
Weight 743g
Power Requirements Dual DC 12~48V, AC 24V
Power Consumption
DC input:
Max. 3.4 watts/11.6BTU (System on)
Max. 8.7 watts/29.7BTU (Full loading)
AC input:
Max. 5 watts/17BTU (System on)
Max. 13.99 watts/47.8BTU (Full loading)
Standards Conformance
Regulatory
Compliance FCC Part 15 Class A, CE
Stability Testing
IEC60068-2-32 (free fall)
IEC60068-2-27 (shock)
IEC60068-2-6 (vibration)
Standards
Compliance
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab 1000BASE-T
IEEE 802.3x ow control and back pressure
IEEE 802.1p Class of Service
IEEE 802.3az Energy Ecient Ethernet (EEE)
IEEE 802.3 10BASE-T
IEEE 802.3u 100BASE-TX
IEEE 802.3ab 1000BASE-T
IEEE 802.3x ow control and back pressure
IEEE 802.1p Class of Service
IEEE 802.3az Energy Ecient Ethernet (EEE)
4.ProductSpecications
Product IGS-1600T
Hardware Specications
Gigabit Ethernet
Copper Ports
16 10/100/1000BASE-T RJ45 auto-MDI/
MDI-X ports
Switch Architecture Store-and-Forward
Switch Fabric 32Gbps (non-blocking)
Throughput
(packet per second) 23.81Mpps@ 64 bytes
Address Table 8K entries, automatic source address
learning and aging
Shared Data Buer 4.1Mbits
Flow Control IEEE 802.3x pause frame for full duplex
Back pressure for half duplex
ESD Protection 6KV DC
Enclosure IP30 metal case
Installation DIN-rail kit and wall-mount kit
Connector
Removable 6-pin terminal block for power
input
Pin 1/2 for Power 1, Pin 3/4 for fault alarm,
Pin 5/6 for Power 2
Alarm One relay output for power failure. Alarm
relay current carry ability: 1A @ 24V DC
Environment
Operating
Temperature -40 ~ 75 degrees C
Storage
Temperature -40 ~ 85 degrees C
Humidity 5 ~ 95% (non-condensing)
5.CustomerSupport
Thank you for purchasing PLANET products. You can browse
our online FAQ resource at the PLANET Web site rst to check if
it could solve your issue. If you need more support information,
please contact PLANET support team.
PLANET online FAQs:
http://www.planet.com.tw/en/support/faq
Switch support team mail address:
Copyright © PLANET Technology Corp. 2021.
Contents are subject to revision without prior notice.
PLANET is a registered trademark of PLANET Technology Corp.
All other trademarks belong to their respective owners.
FCCWarning
This equipment has been tested and found to comply with the
regulations for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with this user’s guide, may cause harmful
interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference, in which
case the user will be required to correct the interference at his own
expense.
AvertissementdelaFCC
Cet équipement a été testé et jugé conforme à la réglementation
pour un appareil numérique de classe A, conformément à la partie
15 des règles de la FCC. Ces limites sont conçues pour fournir une
protection raisonnable contre les interférences nuisibles lorsque
l’équipement est utilisé dans un environnement commercial.
Cet équipement génère, utilise et peut émettre de l’énergie
radiofréquence et, s’il n’est pas installé et utilisé conformément
au présent guide de l’utilisateur, peut causer des interférences
nuisibles aux communications radio. Le fonctionnement de ces
équipements dans une zone résidentielle est susceptible de
provoquer des interférences préjudiciables, auquel cas l’utilisateur
sera tenu de corriger les interférences à ses propres frais.
CEMarkWarning
This is a Class A product. In a domestic environment, this product
may cause radio interference, in which case the user may be
required to take adequate measures.
This equipment is compliant with Class A of CISPR 32. In a
residential environment this equipment may cause radio interference.
AvertissementdemarquageCE
Il s’agit d’un produit de classe A. Dans un environnement
domestique, ce produit peut provoquer des interférences radio,
auquel cas l’utilisateur peut être tenu de prendre des mesures
adéquates.
Cet équipement est conforme à la classe A du CISPR 32. Dans
un environnement résidentiel, cet équipement peut causer des
interférences radio.
WEEEWarning
To avoid the potential eects on the environment and
human health as a result of the presence of hazardous
substances in electrical and electronic equipment, end users
of electrical and electronic equipment should understand
the meaning of the crossed-out wheeled bin symbol. Do not
dispose of WEEE as unsorted municipal waste and have to collect
such WEEE separately.
AvertissementWEEE
An d’éviter les eets potentiels sur l’environnement et la
santé humaine résultant de la présence de substances
dangereuses dans les équipements électriques et
électroniques, les utilisateurs naux d’équipements
électriques et électroniques devraient comprendre la signication du
symbole du bac à roulettes barré. Ne jetez pas les WEEE en tant
que déchets municipaux non triés et devez les collecter
séparément.
  • Page 1 1
  • Page 2 2

Planet IGS-1600T Manuel utilisateur

Catégorie
Commutateurs réseau
Taper
Manuel utilisateur

dans d''autres langues