DMP Electronics 1101 Guide d'installation

Catégorie
Lecteurs de contrôle d'accès
Taper
Guide d'installation
1101 WIRELESS UNIVERSAL
TRANSMITTER
Installation Guide
DESCRIPTION
1
The 1101 Wireless Universal
Transmitter is a two-way
supervisory wireless transmitter
typically used for door and window
applications.
The 1101 provides a cover tamper,
magnetic reed switch, and an
on-board terminal block to allow for
external contact wiring.
Both sets of contacts, internal and
external, can be programmed to
operate at the same time. This
allows two independents zones to
operate from one 1101.
The 1101 also features
Disarm/Disable functionality. When
this option is set to YES, Zone
Tripped messages are disabled
when the system is disarmed to
allows for extended battery life.
Supervision, Tamper, and Low
Battery are the only messages sent
to the panel when the system is
disarmed.
Compatibility
All DMP XTLplus, XT30/XT50, and
XR150/XR550 Series panels and all
1100 Series Wireless Receivers.
What is Included?
One 1101 Wireless Universal
Transmitter
One magnet in a one or two-part
housing
One 3.0V lithium CR123A battery
Hardware pack
Figure 1: 1101 Housing
PROGRAM THE PANEL
Refer to the panel programming guide as needed.
1. In ZONE INFORMATION, enter the wireless ZONE NO: and
press CMD.
2. Enter the ZONE NAME and press CMD.
3. Select the ZONE TYPE and press CMD.
4. At NEXT ZN?, select NO.
5. Select YES when WIRELESS? displays.
6. Enter the eight-digit SERIAL# and press CMD.
7. At CONTACT:, select either INTERNAL or EXTERNAL.
Note: Use consecutive zone numbers if using both
internal and external contacts.
8. Enter the SUPRVSN TIME and press CMD.
9. At DISARM DISABLE:, select NO or YES.
Note: Program the external contact first if using both
internal and external contacts with Disarm/Disable
functionality.
10. At the NEXT ZN? prompt, select YES to finish programming
or select NO for additional programming options.
INSTALL THE BATTERY
3
2
Use a 3.0V lithium battery, a DMP Model CR123A battery, or an
equivalent model from Sony or Murata. For listed installations,
use either an Energizer® 123 battery or a CR123A battery
manufactured by Panasonic or Tekcell. Keep in mind, when
setting up a wireless system, program zones and connect the
receiver before installing the battery.
1. Push the button on the end of the 1101 and separate the
two halves. See Figure 1.
2. Observe polarity and place the battery in the holder and
press it into place.
The 1101 provides a Survey LED capability to allow one person to
confirm communication with the wireless receiver or panel while
the cover is removed.
1. With the cover removed, hold the 1101 in the exact desired
location.
2. Press the tamper switch to send data to the panel and
determine if communication is confirmed or faulty.
Confirmed: If communication is confirmed, for each
press or release of the tamper switch, the LED blinks
immediately on and immediately o.
Faulty: If communication is faulty, the LED remains on
for about 8 seconds or flashes multiple times in quick
succession. Relocate the 1101 or receiver until the LED
confirms clear communication.
SELECT A LOCATION
2 1101 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS
MOUNT THE 1101
Mount the Transmitter
1. Remove the battery.
2. Hold the transmitter in place with the magnetic reed
switch closest to where the magnet will be mounted.
See Figure 2. Ensure the transmitter and the magnet
will be no more than 1/2” (1.3cm) apart.
3. Place the supplied #4 screw into the mounting hole
and secure the transmitter to the surface.
4. Replace the battery.
5. Snap the transmitter cover back onto the base.
Mount the Magnet
Standard Installation
1. Push the supplied magnet into the magnet cover.
2. Hold the magnet base on the door closest to the
magnetic reed switch, no more than 1/2” (1.3cm) from
the transmitter.
3. Use the provided #4 screws to mount the base. See
Figure 3.
4. Snap the cover onto the base.
Commercial Installation
1. Push the supplied magnet into the magnet cover.
2. Place and hold the magnet cover directly on the door
closest to the magnetic reed switch, no more than 1/2”
(1.3cm) apart from the transmitter.
3. Use the provided #4 screws to mount the cover.
See Figure 4.
Figure 2: Transmitter Components
Survey
LED
Mounting
Hole
Magnetic Reed
Switches
PLACEMENT OPTIONS
4
5
TEST THE 1101
After installing the 1101, perform a Walk Test to confirm the 1101 is communicating with the panel. At the
keypad, enter 8144 (WALK) and select WLS. If the 1101 fails to check in at the keypad, relocate the wireless
device, receiver, or panel.
Figure 5: Placement Options
Figure 3: Standard Installation
Figure 4: Commercial Installation
1101 INSTALLATION GUIDE | DIGITAL MONITORING PRODUCTS 3
Connect External Contacts
Refer to Contacts and Zone Information in the appropriate panel programming guide for more information.
DMP recommends using 18 or 22 AWG un-shielded wire. If you use both the magnet reed switch in the 1101
transmitter and an external contact, use consecutive zone numbers when connecting them to the panel.
1. Remove the cover of the 1101.
2. Use a flat head screwdriver to loosen the two screws on the external contact terminal block.
See Figure 6.
3. Insert external contact wiring into the 1101 terminal block and re-tighten the screws.
4. Connect the other ends of the wires to the external contact as either normally open (N/O) or normally
closed (N/C) without an end-of-line resistor.
ADDITIONAL INFORMATION
1. Open the transmitter housing to expose the inside of the 1101.
2. Remove the old battery, observe polarity, and place the new battery in the holder.
3. Snap the cover back on the 1101.
Replace the Battery
Once the battery is replaced, a sensor reset is required at the keypad to clear the LOBAT message.
1. On an LCD Keypad, press and hold 2 for two seconds.
On a Graphic Touchscreen Keypad, press RESET.
2. Enter your user code, if required. The keypad displays SENSORS OFF followed by SENSORS
ON.
Sensor Reset to Clear LOBAT
EXTERNAL CONTACTS
Figure 6: Connect External Contact
External Contact
Terminal Block
1101
Door
Window
External
Contact
Magnet
Program an internal
contact as the next
consecutive zone.
Program an
external contact as
the first zone.
Designed, engineered,
and manufactured in
Springfield, Missouri using U.S.
and global components.
LT-0694 1.04 18133
INTRUSION FIRE ACCESS NETWORKS
2500 North Partnership Boulevard
Springfield, Missouri 65803-8877
866-266-2826 | dmp.com
Patents
U.S. Patent No. 7, 239, 236
Certifications
FCC Part 15 Registration ID CCKPC0191
Industry Canada Registration ID 5251A-PC0191
Underwriters Laboratory (UL) Listed
ANSI/UL 1023 Household Burglar Alarm System Units
Accessory Magnetically Activated Switch or Door Contact
Transmitter
ANSI/UL 634 Connections and Switches for use with Burglar
Alarm Systems Accessory
1101 Wireless Universal
Transmitter
Specifications
Battery
Life Expectancy 5 Years (normal operation)
Type 3.0V lithium CR123A
Frequency Range 905-924 MHz
Dimensions
Transmitter Case 3.3” L x 1.6” W x 0.9” H
Transmitter Base 3.3” L x 1.6” W x 0.1” H
Magnet Housing 1.5” L x 0.5” W x 0.7” H
Magnet Spacer 1.5” L x 0.5” W x 0.1” H
Color White (1101-W), Black (1101-B)
Housing Material Flame retardant ABS
FCC INFORMATION
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. this device must accept any interference received, including interference that may cause undesired operation.
The antenna used for this transmitter must be installed to provide a separation distance of at least 20cm (7.874 in.) from all persons. It
must not be located or operated in conjunction with any other antenna or transmitter.
Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Information
This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two
conditions:
1. This device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired operation of the device.
This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health
Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general
bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
Lexploitation est autorisée aux deux conditions suivantes:
1. l’appareil ne doit pas produire de brouillage, et
2. l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d’en compromettre le fonctionnement.
Lexposition aux radiofréquences de ce système a été évaluée selon la norme RSS-102 et est jugée conforme aux limites
établies par le Code de sécurité 6 de Santé Canada. Le système doit être installé à une distance minimale de 7.87 pouces
(20 cm) séparant l’antenne d’une personne présente en conformité avec les limites permises d’exposition du grand
public.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

DMP Electronics 1101 Guide d'installation

Catégorie
Lecteurs de contrôle d'accès
Taper
Guide d'installation

dans d''autres langues