1) TURN OFF POWER.
IMPORTANT: Before you start, NEVER attempt any work
without shutting off the electricity until the work is done.
a) Go to the main fuse, or circuit breaker, box in your
home. Place the main power switch in the “OFF” position.
b) Unscrew the fuse(s), or switch “OFF” the circuit breaker
switch(s), that control the power to the fixture or room
that you are working on.
c) Place the wall switch in the “OFF” position. If the fixture
to be replaced has a switch or pull chain, place those in
the “OFF” position.
5) Slip fixture over post and mark position of mounting holes in
post.
6) Remove fixture from post.
7) Drill 3/16” dia holes in post at positions marked .
8) If fixture is provided with ground wire, connect fixture
ground wire to outlet box ground wire with wire connector.
(Not provided). Never connect ground wire to black or white
power supply wires.
9) Make wire connections (connectors not provided). Reference
chart below for correct connections and wire accordingly.
10) Slip fixture over post and secure in place using provided
screws. Screws should slip into holes drilled in post.
11) Thread top trim onto coupling on top of fixture.
1) COUPER L’ALIMENTATION SECTEUR.
IMPORTANT: TOUJOURS couper l’électricité avant de
commencer le travail.
a) Localiser le coffret à fusibles ou le disjoncteur du
domicile. Mettre l’interrupteur principal en position
d’Arrêt.
b) Dévisser le ou les fusibles (ou mettre le disjoncteur sur
Arrêt) qui contrôlent l’alimentation vers le luminaire ou la
pièce dans laquelle le travail est effectué.
c) Mettre l’interrupteur mural en position d’Arrêt. Si le luminaire
à remplacer est doté d’un interrupteur ou d’une chaîne
connectée à l‘interrupteur, placer ces éléments en
position d’Arrêt.
5) Passer le luminaire par dessus le support et marquer un
repère pour les trous de montage sur le support.
6) Enlever le luminaire du support.
7) Percer des trous de 1/8 po sur chacun des repères du
support.
8) Si luminaire est fourni a vec un fil de mise à la terre, le
connecter à la boîte de sortie de courant de mise à la terre
avec un serre-fils (non fourni). Ne jamais connecter un fil de
mise à la terre aux fils d’alimentation noir ou blanc.
9) Connecter les fils (connecteurs non fournis). Se porter au
tableau ci-dessous pour faire les connexions.
10) Faire glisser le luminaire sur le support et fixer à l’aide des
vis. Les vis doivent s’ajuster correctement dans les trous du
support.
11) Visser la garniture supérieure sur l’accouplement sur le
dessus du luminaire.
Connect Black or
Red Supply Wire to:
Connect
White Supply Wire to:
Black White
*Parallel cord (round & smooth) *Parallel cord (square & ridged)
Clear, Brown, Gold or Black
without tracer
Clear, Brown, Gold or Black
with tracer
Insulated wire (other than green)
with copper conductor
Insulated wire (other than green)
with silver conductor
*Note: When parallel wires (SPT I & SPT II)
are used. The neutral wire is square shaped
or ridged and the other wire will be round in
shape or smooth (see illus.)
Neutral Wire
Date Issued: 3/14/14 IS-9909LED-CB
For Assembling and Installing Fixtures in Canada
Pour L’assemblage et L’installation Au Canada
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
FIXTURE
LUMINAIRE
SCREW
VIS
COUPLING
ACCOUPLEMENT
Connecter le fil noir ou
rouge de la boite
Connecter le fil blanc de la boîte
A Noir A Blanc
*Au cordon parallèle (rond et lisse)
*Au cordon parallele (à angles droits el strié)
Au bransparent, doré, marron, ou
noir sans fil distinctif
Au transparent, doré, marron, ou
noir avec un til distinctif
Fil isolé (sauf fil vert) avec
conducteur en cuivre
Fil isolé (sauf fil vert) avec
conducteur en argent
*Remarque: Avec emploi d’un fil paralléle
(SPT I et SPT II). Le fil neutre est á angles
droits ou strié et l’autre fil doit étre rond ou
lisse (Voir le schéma).
Fil Neutre
TOP TRIM