Kichler Lighting 49876BK Manuel utilisateur

Taper
Manuel utilisateur

Ce manuel convient également à

IS-49876-US
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[E].
Thread mounng screws[D] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap to outlet box with strap mounng
screws[C]. Mounng strap can be adjusted to suit
posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture to wall over the protruding screws in the
mounng strap. Be sure not to pinch wires between wall
and canopy of xture.
6) Screw on the two (2) ball knobs[F] to the canopy[E]
Tighten to secure.
7) Insert recommended bulb(s). (Not supplied)
8) Place the glass[J] over the installed bulb and secure into
place using four (4) ball knobs[F] by threading on the
protruding studs.
9) Lower the top[H] onto the frame as shown and secure
into place with the two (2) screws[I].
10) Take the decorave arm[G] and hook into the large
loop and secure to the canopy using the sheet metal
screw[K].
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting Strap
[B] Outlet Box
[C] Strap Mounting
Screws
[D] Mounting
Screws
[E] Canopy
[F] Ball Knobs
[G] Decorative Arm
[H] Top
[I] Screws
[J] Glass
[K] Sheet Metal
Screw
E
F
A
C
B
D
G
H
I
J
K
F
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/
OR IN WET LOCATIONS.
Mounng surface should be clean, dry, at and 1/4”
larger than the canopy on all sides. Any gaps between the
mounng surface and canopy exceeding 3/16” should be
corrected as required.
With silicone caulking compound, caulk completely
around where back of canopy meets the wall surface to
prevent water from seeping into outlet box.
IS-49876-US
Estamos aquí para ayudarle 866-558-5706
Horario: Lunes-Viernes 9am a 5pm EST (hora ocial del este)
2) Fije la correa de montaje a la caja de salida con los
tornillos de jación de la correa[C]. La correa de montaje
se puede ajustar para adaptarse a la posición del
aparato.
3) Instrucciones de conexión a erra solamente para los
Estados Unidos. (Vea la ilustracion a o b).
a) En las lámparas que enen el eje, de montaje con
un agujero y dos hoyuelos realzados, enrollar el
alambre a erra de la caja tomacorriente alrededor
del tornillo verde y pasarlo por el aquiero.
b) En las lámparas con una arandela acopada, jar el
alambre a erra de la caja tomacorriente del ajo de
la arandela acoada y tornillo verde, y paser por el
eje de montaje.
Si la lámpara viene con alambre a erra, conecter el
alambre a erra de la lámpara al alambre a erra de la
caja tomacorriente con un conector de alambres (No
incluido) espués de seguir los pasos anteriores. Nunca
conectar el alambra a erra a los alambres eléctros
negro o blanco.
4) Haga les conexiones de los alambres. La tabla de
referencia de abajo indica las conexiones correctas y los
alambres correspondientes.
Conectar el alambre de
suministro negro o rojo al
Conectar el alambre de
suministro blanco al
Negro Blanco
*Cordon paralelo (redondo
y liso)
*Cordon paralelo (cuadrado
y estriado)
Claro, marrón, amarillio
o negro sin hebra
idencadora
Claro, marrón, amarillio
o negro con hebra
idencadora
Alambre aislado (diferente
del verde) con conductor
de cobre
Alambre aislado (diferente
del verde) con conductor
de plata
*Nota: Cuando se uliza alambre
paralelo (SPT 1 y SPT 2). El alambre
neutro es de forma cuadrada o
estriada y el otro alambre será
de forma redonda o lisa. (Vea la
ilustracíón).
Hilo Neutral
5) Empuje el artefacto a la pared sobre los tornillos que
sobresalen de la abrazadera de montaje. Asegúrese de
no apretar los cables entre la pared y el escudete del
artefacto.
6) Atornille las dos (2) perillas redondas [F] al dosel [E].
Ajústelas para asegurarlas.
7) Inserte la(s) bombilla(s) recomendada(s). (No
suministradas).
8) Coloque el vidrio [J] sobre la bombilla instalada y
asegúrelo en su lugar usando cuatro (4) perillas redondas
[F] enroscándolas en los espárragos que sobresalen.
9) Baje la parte superior [H] sobre el marco como se
muestra y jela en su lugar con los dos (2) tornillos [I].
10) Tome el brazo decoravo [G] y engánchelo en el anillo
grande, y jelo al escudete usando el tornillo para metal
[K].
ARANDELA
CONCAVA
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
DEPRESIONES
TIERRA
ARTEFACTO
CONECTOR DE ALAMBRE
TIERRA DE LA
CAJA DE SALIDA
TORNILLO DE TIERRA,
VERDE
TIERRA
ARTEFACTO
a
b
Diagrama de Accesorios
Lista de Partes
[A] Correa de
Montaje
[B] Caja de Salida
[C] Tornillos de
Fijación de la
Correa
[D] Tornillos de
Montaje
[E] Dosel
[F] Perillas
redondas
[G] Brazo
decoravo
[H] Parte superior
[I] Tornillos
[J] Vidrio
[K] Tornillo para
metal
Precauciones
PRECAUCIÓN – RIESGO DE DESCARGA ELÉCTRICA –
Desconecte la electricidad en el panel principal del
interruptor automáco o caja principal de fusibles antes de
comenzar y durante la instalación.
ADVERTENCIA:
Este accesorio está desnado a la instalación de
acuerdo con el Naonal Electrical Code (NEC) y todas las
especicaciones del código local. Si no está familiarizado
con los requisitos del código, la instalación se recomienda
un electricista cercado.
Instrucciones de Instalación
1) Encuentre los oricios roscados adecuados en la correa
de montaje[A] que se alinean con la distancia del agujero
en el dosel[E]. Enrosque los tornillos de montaje[D]
en los oricios roscados desde el lado de la caja de
salida[B].
E
F
A
C
B
D
G
H
I
J
K
F
INSTRUCCIONES PARA EL MONTAJE DEL ARTEFACTO AL
AIRE LIBRE Y/O EN UN LUGAR MOJADO.
La supercie de montaje debe estar limpia, seca, ser
plana y 1/4” más grande que el esdudete en todos
los bordes. Cualquier espacio libre entre la supercie
de montaje y el escudete que exceda de 3/16” debe
corregirse según se requiera.
Calafatee totalmente con compuesto de calafatear
de silicona alrededor donde el escudete sienta en la
supercie de la pared para impedir la entrada de agua en
la caja de conexiones.
IS-49876-CB
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
1) Find the appropriate threaded holes on mounng
strap[A] that align with hole distance in canopy[E].
Thread mounng screws[D] into threaded holes starng
from outlet box[B] side.
2) Aach mounng strap to outlet box with strap mounng
screws[C]. Mounng strap can be adjusted to suit
posion of xture.
3) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a
hole and two raised dimples, wrap ground wire from
outlet box around green ground screw, and thread
into hole.
b) On xtures where a cupped washer is provided,
aach ground wire from outlet box under cupped
washer and green ground screw, then thread into
mounng strap.
If xture is provided with ground wire, connect xture
ground wire to outlet box ground wire with wire
connector (Not provided) aer following the above steps.
Never connect ground wire to black or white power
supply wires.
4) Make wire connecons. Reference chart below for
correct connecons and wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth (See illus.)
Neutral Wire
5) Push xture to wall over the protruding screws in the
mounng strap. Be sure not to pinch wires between wall
and canopy of xture.
6) Screw on the two (2) ball knobs[F] to the canopy[E]
Tighten to secure.
7) Insert recommended bulb(s). (Not supplied)
8) Place the glass[J] over the installed bulb and secure into
place using four (4) ball knobs[F] by threading on the
protruding studs.
9) Lower the top[H] onto the frame as shown and secure
into place with the two (2) screws[I].
10) Take the decorave arm[G] and hook into the large
loop and secure to the canopy using the sheet metal
screw[K].
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main
fusebox before starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance
with the Naonal Electrical Code (NEC) and all local code
specicaons. If you are not familiar with code requirements,
installaon by a cered electrician is recommended.
Installaon Instrucons
[A] Mounting Strap
[B] Outlet Box
[C] Strap Mounting
Screws
[D] Mounting
Screws
[E] Canopy
[F] Ball Knobs
[G] Decorative Arm
[H] Top
[I] Screws
[J] Glass
[K] Sheet Metal
Screw
E
F
A
C
B
D
G
H
I
J
K
F
INSTRUCTIONS FOR MOUNTING FIXTURE OUTDOORS AND/
OR IN WET LOCATIONS.
Mounng surface should be clean, dry, at and 1/4”
larger than the canopy on all sides. Any gaps between the
mounng surface and canopy exceeding 3/16” should be
corrected as required.
With silicone caulking compound, caulk completely
around where back of canopy meets the wall surface to
prevent water from seeping into outlet box.
IS-49876-CB
Nous sommes là pour vous aider 866-558-5706
Heures : du lundi au vendredi, de 9h à 17h (heure de lEst)
INSTRUCTIONS:
For Assembling and Installing Fixtures in Canada
Pour Lassemblage et L’installaon Au Canada
1) Trouvez les trous letés appropriés sur la sangle de
montage[A] qui s’alignent avec la distance du trou dans
le couvert[E]. Vis de montage[D] du letage dans les
trous letés à parr du côté sore[B] côté.
2) Fixez la sangle de montage à la boîte de sore avec les
vis de xaon de la sangle[C]. La sangle de montage
peut être réglée en foncon de la posion du luminaire.
3) Connecter les ls. Se reporter au tableau ci-dessous pour
faire les connexions.
Connecter le l noir ou
rouge de la boite
Connecter le l blanc de
la boîte
A Noir A Blanc
*Au cordon parallèle (rond
et lisse)
*Au cordon parallèle (à
angles droits el strié)
Au transparent, doré,
marron, ou noir sans l
disncf
Au transparent, doré,
marron, ou noir avec un l
disncf
Fil isolé (sauf l vert) avec
conducteur en cuivre
Fil isolé (sauf l vert) avec
conducteur en argent
*Remarque: Avec emploi d’un
l paralléle (SPT 1 et SPT 2). Le
l neutre est á angles droits ou
strié et lautre l doit étre rond
ou lisse (Voir le schéma).
Fil Neutre
4) Poussez le luminaire vers le mur par-dessus les vis
dépassant de la surface dans le support de montage. Ne
pas pincer les ls entre le mur et le cache du luminaire.
5) Vissez les deux (2) boules à bille [F] sur le cache [E].
Serrez pour xer.
6) Installez la ou les ampoules recommandées (non
fournies).
7) Placez le verre [J] sur lampoule installée et xez-le à
laide de quatre (4) boules à bille [F] en vissant sur les
goujons dépassant de la surface.
8) Abaissez la pare supérieure [H] sur le cadre (voir
illustraon) et xez-la avec les deux (2) vis [I].
9) Prenez le bras décoraf [G], accrochez-le à la grande
boucle et xez-le au cache à laide de la vis de feuille
métallique [K].
Diagramme d’appareils
ATTENTION – RISQUE DE DÉCHARGES ÉLECTRIQUES -
Couper le courant au niveau du panneau du disjoncteur du
circuit principal ou de la boîte à fusibles principale avant de
procéder à l’installaon.
ATTENTION:
Ce luminaire doit être installé conformément aux codes
d’électricité naonaux (NEC) et sasfaire toutes les
spécicaons des codes locaux. Si vous ne connaissez pas
les exigences de ces codes, il est recommandé de coner
l’installaon à un électricien ceré.
Liste des Pièces
Précauons
[A] Sangle de
Montage
[B] Côté Sortie
[C] Vis de Fixation
de la Sangle
[D] Vis de
Montage
[E] Couvert
[F] Boutons de
Verrouillage
[G] Bras décoraf
[H] Pare
supérieure
[I] Vis
[J] Verre
[K] Vis de feuille
métallique
Instrucons d’installaon
E
F
A
C
B
D
G
H
I
J
K
F
INSTRUCTIONS DE MONTAGE DE LUMINAIRE À
L’EXTÉRIEUR ET/OU DANS DES LIEUX HUMIDES.
La surface de montage doit être propre, sèche, plate et
de 0,6 cm plus épaisse que le cache sur tous les côtés.
Tout écart entre la surface de montage et le cache
dépassant de 0,5 cm doit être recé selon les besoins.
À laide de matériaux détanchéité à la silicone, calfeutrer
bien autour où l’arrière du cache entre en contact avec
le mur pour empêcher l’eau de passer dans la boîte de
raccordement.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Kichler Lighting 49876BK Manuel utilisateur

Taper
Manuel utilisateur
Ce manuel convient également à