3
514-326
≤100mA
4.75V DC - 5.25V DC
Current
Voltage
Operating
temperature
Waterproof
-40°C - +66°C
-40°F - +131°F
Installation guidelines
Desktop Reader
Power supply
Maintenance
This unit is for indoor use only
• Plug the reader into a convenient USB port on the PC with the
supplied USB cable
• Stop and then restart the Net2 server program. The device will
now be available to the Net2 program
• This unit requires Net2 v3.09 or later software. Support for Mifare
cards requires v4.17 or later.
• Call Technical Support if you require a software upgrade.
The desktop reader is designed to sit next to the PC. It is used for adding
tokens to a Net2 system and also for identifying lost cards. Additional
workstations can also have desktop readers.
With the Net2 software running, any new token presented above the
desktop reader will cause the new user wizard to appear with the
appropriate card number displayed.
The users details can then be entered and the token issued. If the token
is already known to the system, the relevant user’s record will appear
• The power for the unit is supplied via the USB cable. No additional
supply is required
• Wiring methods shall be in accordance with the National Electrical
Code (ANSI/NFPA70), local codes, and the authorities having
jurisdiction.
• Following the completed installation of this equipment, no further
maintenance or testing is required.
• It is advisable to ensure that any third party backup power supplies
or recovery procedures are checked regularly to ensure that the
operation of the Paxton system is not compromised.