Real Flame CT0011LP Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire
CT0011LP-GLS Ledgestone Square
WARNING
WARNING
DANGER
WARNING
FIRE TABLE OWNER’S MANUAL
!
!
!
!
For outdoor use only.
If you smell gas:
• Shut o gas to the appliance.
• Extinguish any open flame.
• If odor continues, keep
away from the appliance and
immediately call your gas
supplier or fire department.
Do not store or use gasoline or other flammable liquids
in the vicinity of this or any other appliance.
An LP-cylinder not connected for use should not be
stored in the vicinity of this or any other appliance.
Improper installation, adjustment, alteration, service, or
maintenance can cause injury or property damage.
Read the installation, operation and maintenance instructions
thoroughly before installing or servicing this equipment.
170822FT-171212
2
TABLE OF CONTENTS
Important Safety Information
Gas Dangers and Warnings
Parts List
Assembly Instructions
Pre-Use Instructions
Lighting Instructions
Care and Cleaning
Spider and Insect Warning
Tips & Troubleshooting
Technical Parts List
Warranty
3
5
6
7
9
10
11
12
13
15
16
DANGER
SPECIFICATIONS
!
CARBON MONOXIDE HAZARD
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed
space such as a camper, tent, car or home.
Check and update Specs
Verify Page numbers
Product Name
Square Ledgestone Fire Table
Model No.
CT0011LP-GLS
Rated Heat Output
65,000 BTUs/hr
Type of Gas
Propane (LP)
Gas Supply
20 lb LP-Gas cylinder
3
IMPORTANT SAFETY INFORMATION
Installation notes
General Warnings
Minimum Clearance from unit to combustible materials:
48” (121.9 cm) from all sides and back. Do not place this fire table under any overhead structure or
vegetation. Do not place on or above combustible surfaces.
Save these instructions for future reference. If you are assembling this unit for someone else, give this
manual to them to read and save for future reference.
If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury, or death.
Installation and service must be performed by a qualified service agency or gas supplier. Real Flame
recommends using professionals who are certified in the U.S. by the National Fireplace Institute® (NFI)
as NFI Gas Specialists.
The normal LP inlet pressure for this appliance is 11.0” W.C. (2.74 kPa), maximum inlet pressure is 13.0”
W.C. (3.23 kPa), minimum inlet pressure is 8” W.C. (1.99 kPa).
If this fire table has been converted to natural gas, the normal inlet pressure for this appliance is 7.0”
W.C. (1.74 kPa), maximum inlet pressure is 10.5” W.C. (2.61kPa), minimum inlet pressure is 3.5” W.C.
(0.87 kPa).
Do not remove the feet from the fire table.
Do not place the fire table on anything that blocks or seals the gap between the table and the ground.
Do not permanently secure the fire table in any way or to any surfaces.
Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
Do not coil or hide the hose under the fire table. The hose could be damaged if it touches hot
surfaces.
Children and adults should be alerted to the hazards of high surface temperatures and should stay
away to avoid burns or clothing ignition.
Young children should be carefully supervised when in the area of the fire table.
Clothing or other flammable materials should not be hung from the fire table or placed on or near
the appliance.
Any guard or other protective device removed for servicing the fire table must be replaced prior to
operating the appliance.
Installation and repair should be done by a qualified service person. The fire table should be
inspected before use and at least annually by a qualified service person. More frequent cleaning
may be required as necessary. It is imperative that the control compartment, burners, and
circulating air passageways of the appliance are kept clean.
Do not store or use gasoline or other flammable vapors or liquids within 25 feet ( 7.62 m) of this or
any other appliance.
Do not store combustible materials in the fire table enclosure. This includes LP tanks. If the fire table
is designed to use a hidden LP tank, the LP tank should be properly secured in the designated tank
holder under the table. Do not store extra LP tanks under the fire table.
Be sure to protect the hose and its components from any hot surfaces. It is dangerous to allow the
hose to come into contact with any hot surface.
If using your fire table with a LP tank, the tank should never be operated or stored on its side or up-
side-down.
4
IMPORTANT SAFETY INFORMATION
General Warnings (Cont.)
Set-Up Warnings
In-Use Warnings
Keep all parts of the fire table clean including the burner and hose assembly. For more information on
cleaning your fire table please refer to the Care and Cleaning section of this manual.
Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas control
that has been under water.
Do not use this fire table for cooking.
Do not pour water into the fire table.
Do not attempt to move or store this fire table until all parts are cool.
Always shut o the gas supply at the source and disconnect the hose when the fire table is not in use.
Any alteration of this outdoor fire table that is not specifically directed in the owners manual will void
the manufacturers warranty. This includes the use of unapproved filler materials.
Prior to each operation, check the hose assembly for evidence of excessive abrasion, wear or damage.
Use a hand-held mirror, if necessary, to see hose sections located below the unit.
If the hose assembly is damaged, cracked, or cut, it must be replaced before using the fire table.
The hose assembly must be replaced with a hose assembly specified by Real Flame. Please call us at
1-800-654-1704 for assistance.
Place the hose out of the pathways where people may trip over it. Do not place the hose in areas
where it may be accidentally damaged.
Before each use, examine the burner and its components for dirt and debris. If cleaning is required,
use a pipe brush and soapy water solution. Also examine the area around the burner. Any dirt or
foreign material such as spider webs, nests, leaves, etc., should be removed. If it is evident that the
burner is damaged, the fire table must not be used, and the burner assembly must be replaced. Please
contact Real Flame at 1-800-654-1704 for support.
Do not burn solid fuels such as wood, charcoal briquettes, lump charcoal, manufactured logs, drift
wood, trash, leaves, paper, cardboard, plywood, painted, stained or pressure-treated wood and other
materials in this fire table.
NEVER LEAVE this fire table unattended when in use.
The use of alcohol, prescription or non-prescription drugs may impair your ability to safely operate
this fire table.
Always use in accordance with all applicable local, state and national codes. Contact your local fire
department for details on outdoor burning.
Do not use in windy conditions. Winds above 10 mph may cause the flame to extinguish.
Some surfaces of this fire table may become hot during use. Be careful and do not touch surfaces
until the unit has cooled.
5
GAS DANGERS AND WARNINGS
LP Gas Warnings
LP Characteristics
LP gas is flammable, explosive under pressure, heavier than air and settles in pools in low areas.
Pooled gas may ignite causing a fire or explosion which could cause property damage, injury or death.
In its natural state, propane has no odor. For your safety, a scent has been added.
Contact with propane could burn your skin.
LP Tank Information
LP gas cylinders should be filled only by a certified LP gas dealer.
Never use a propane cylinder with a damaged body, valve, collar or footing.
Dented or rusted propane cylinders may be hazardous and should be checked by your propane gas
supplier.
The LP gas supply tank must be constructed and marked in accordance with the Specifications for
LP gas tanks of the U.S. Department of Transportation (DOT) or the National Standard of Canada,
CAN/CSA-B339, LP gas tanks, Spheres and Tubes for the Transportation of Dangerous Goods; and
Commission.
LP gas tanks must be arranged for vapor withdrawal.
LP gas tanks must have a listed overfilling prevention device (OPD) and a QCCI or Type I (CGA810) LP
gas tank connection.
The LP gas cylinder must contain a shuto valve as specified in the Standard for Compressed Gas
Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96.
Never attempt to attach this appliance to the self-contained LP gas system of a camper trailer, motor
home or house.
Hand-turn the manual gas control valve on your LP tank. Never use tools. If the valve will not turn by
hand, do not try to repair it. Call a certified gas technician.
The use of force or any attempt at amateur repair may cause a fire or explosion.
LP Tank Storage and Safety
Cylinders must be stored upright and outdoors in a well-ventilated area out of reach of children.
Never store an LP cylinder in any enclosed area such as a shed or garage. Leaking gas could build up
in these areas and may result in an explosion.
Do not store LP gas tanks near any source of flame or ignition.
Never store your LP gas tank in direct sunlight or where temperatures can reach 125°F or higher.
Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure to increase,
which may open the relief valve and allow gas to escape.
Place dust cap on valve outlet whenever the LP gas tank is not in use. Install only the type of dust cap
on the LP gas tank valve outlet that is provided with the LP gas tank valve. Other types of caps or
plugs may result in leakage of propane.
The LP gas tank should not be dropped or handled roughly.
LP gas is flammable and hazardous if handled improperly. Become aware of its characteristics before
using any LP gas product. Failure to understand and follow these warnings or any directions and
warnings provided by your LP supplier may result in property damage, injury or death.
DANGER
!
A LP cylinder should never be placed on its side. Doing so may cause liquid propane to leak. This
could cause a fast build-up of propane gas and could lead to property damage, injury or death.
In-Use Warnings (Cont.)
Do not attempt to disconnect the gas supply from the fire table when the unit is in use.
Do not sit on the fire table.
6
PARTS LIST
Square Fire Table N/A 1
LP Hose and Regulator 100190000 1
Feet 06000003 4
Glass Beads 00036204 1
Tank Seat 100260000 1
Protective Cover 00110006 1
NG Conversion Kit 00023109S 1
1
4
1
2
5
2
3
6
7
3
5
6
4
00023109S
7
7
ASSEMBLY INSTRUCTIONS
1.) Install the AAA battery as shown in the diagram below
Lava Rock and Glass Filler Warning
1. Do not overfill the burner area with rock or glass filler; use only the specified amount. The depth
of the filler should not be more than one inch above the burner tube. Only Real Flame filler products
have been certified and tested for safe use with this Real Flame fire table. Using other filler material
may result in increased popping and cracking or increased carbon monoxide emissions.
2. Do not light or use this fire table if the filler is wet. Ensure filler is completely dry before lighting.
Intense heat can cause wet filler to explode and hit someone causing injury.
3. Keep away from the fire table for at least 20 minutes during initial start-up as filler could retain
moisture from manufacturing and shipping.
+
-
Igniter box
2.) Place (lava rock, glass filler, other) by hand. Do not dump the bag into the burner
area, or directly onto the burner to avoid clogging the burner with dust. Position the filler
material across the burn area to a level 1” above the burner. Make sure that you do not
block the igniter housing with filler to ensure proper ignition and operation.
If using glass filler Real Flame suggests placing a layer of lava rock down first around the
burner then adding glass on top of that to improve airflow to the burner.
8
ASSEMBLY INSTRUCTIONS
4.) Connect the LP Gas Tank
Before connection, be sure there is no debris caught in the
collar of the gas cylinder, the regulator valve or the burner
and burner ports.
Connect the gas line to the tank by turning the connection
knob clockwise. Hand tighten only.
To disconnect the LP tank, make sure the valve on the LP
gas tank is completely closed.
Disconnect the connection knob by turning it counter-
clockwise until it is detached from the valve.
WARNING
!
Place the LP tank 56” away from the fire table and
locate the hose away from pathways or places where
it could become damaged.
Watch your step while moving between the tank and
the fire table. Be careful not to trip on the hose.
3.) Place the tank seat on the ground and place a 20 lb. propane tank into the
designated area in the center. Once the tank is level and steady, tighten down the
screw on the side of the tank seat to secure the tank in place.
9
PRE-USE INSTRUCTIONS
WARNING
!
Before using this fire table, make sure you have read, understand, and are following all information
provided in this manual. Failure to follow these instructions could cause property damage, serious
injury or death.
Make a leak check solution by mixing one part dish-washing soap with three parts water in a spray
bottle.
Make sure that the control knob on the fire table is in the OFF position, then connect your fire
table to a LP gas tank and turn the tank’s valve on.
Spray leak solution on the valve connections, paying particular attention to the areas indicated in
the diagrams below by arrows.
If bubbles appear, close the tank valve, disconnect the tank, and inspect all connections making
sure threads are clear of debris. Reconnect the LP tank and re-test. If you continue to see bubbles,
turn the LP gas tank o, disconnect it and call Real Flame at 1-800-654-1704 for assistance.
If no bubbles appear after one minute, wipe away excess leak solution and proceed to the next
step.
Checking for Leaks
Pay close attention to the areas indicated by the arrows
10
LIGHTING INSTRUCTIONS
Using the Igniter
1. Read and understand all operating instructions before lighting.
2. Before beginning, make sure the control knob is in the OFF position.
3. Connect your propane cylinder (see previous pages).
4. Slowly open the valve on your LP cylinder.
5. Prepare to ignite your fire table by placing one hand on the control
knob and one hand on the ignition button(as seen in diagram on the
right). DO NOT lean over any part of the burner, and verify that the
area around the burner is free of hazards.
6. Push and hold the igniter, you should hear a clicking sound.
7. While holding the igniter depressed with one hand, use your other
hand to push in and turn the control knob to the LIGHT position.
8. Once the burner ignites, release the igniter button, but continue to keep the control knob
pushed in for 15-30 seconds.
9. WARNING: If ignition does not occur in 30 seconds, turn the control knob to the “OFF”
position and turn the gas o at its source. Make sure there is no source of ignition around
the fire table and wait at least five minutes until the gas has cleared to repeat the lighting
procedure. Failure to do so could result in a large flashback of pooled gas, causing property
damage or injury.
10. After successfully lighting the table, release the control knob and turn it to the LOW setting.
Observe the flame and make sure that all the burn ports are lit.
11. Adjust the flame to the desired height using the control knob.
1. Turn the control knob to the OFF position.
2. Close the valve on the LP tank to shut-o gas flow.
Shut-o Instructions
Push Control
Knob In
Flame Height
8-14”
20.3-35.5 cm
11
CARE AND CLEANING
Inspecting Your Fire Table
General Care and Cleaning
Storage
Your fire table should be inspected regularly to ensure that it is safe to use and to extend the life
of its parts.
To inspect your fire table follow these steps.
1. Make sure all parts are securely fastened in place. If a part moves when touched, check its
connection points to see if they are loose.
2. Check all connections for leaks using the leak check method described in the “Check for Leaks”
section of this manual.
3. Check the ignition system by pushing the igniter button and verifying that a spark is being
generated in the igniter housing.
4. Visually check all components for any signs of damage, rust, or excessive wear.
5. If damage or leaks of any kind are found, DO NOT operate the fire table until the proper repairs
have been made.
After repeated use, a slight discoloration or weathering of the fire table finish may occur. Your fire
table should be cleaned regularly to ensure safe use and extend its life.
General Cleaning
Make a cleaning solution using a mild soap mixed with water. Use a soft cloth to wipe down
exterior surfaces and rinse with clean water. Never use oven cleaners or abrasive solvents as these
will damage the fire table.
Burner
The burner should be kept clean to ensure proper operation. Clogged burn ports may be cleared
with a paper clip or pin. Debris in the burner can be cleaned using compressed air or a pipe brush.
Soot
After use it is possible for soot to develop on some surfaces, this soot deposit will usually come o
with water and mild soap.
1. Turn the gas supply o at the tank. Remove the tank and store it in a cool, dry location, outside
and away from children.
2. Secure all loose filler material or parts.
3. Remove the battery from the ignition box.
4. Cover your fire table when it will not be in use. Covering the table will help to protect the
internal components from dirt and debris, prevent water from pooling on the surfaces and
prevent the finish from fading and discoloring.
5. Store the fire table in a cool, dry location away from children and pets.
WARNING
WARNING
!
!
DO NOT inspect, clean, move or store your fire table until the flames are COMPLETELY out and all
parts are cool to the touch.
DO NOT tamper with this appliance. This is dangerous and will void the warranty.
Repairs and modifications must be approved by Real Flame and completed by a professional gas
technician.
This fire table has been tested and certified by a third party certification agency based on its
specific and unique parts. Installing any other parts will void both the certification and the
warranty. For approved replacement parts, contact Real Flame at: 1-800-654-1704
12
SPIDER AND INSECT WARNING
Spiders or other insects may build webs or nests in your fire table burner tube which can obstruct or
block the flow of gas.
Some of the gas may back up in the burn tube and cause a flashback (a fire in the burn tube or
underneath the fire table) which could result in personal injury or property damage. Check and clean the
burn tube periodically using a pipe cleaner brush (as shown below) available at any hardware store.
Example of a typical burn tube
Your exact burner may vary
Burn Tube
Insect Nest
Venturi
Air Intake
Run Pipe Cleaner
through burn tube
Possible Spider
Nest or Debris
Example of pipe
cleaning brush available
at local hardware stores.
13
TIPS & TROUBLESHOOTING
If the fire table will not ignite
If the fire table will not stay lit
1. Make sure that the battery is not dead and that it is installed correctly, with the
positive (+) side facing out.
1. Make sure that the igniter housing is unobstructed. Clear away any filler material or debris on the
housing and make sure there is nothing between the igniter pin and the thermocouple.
If the ignition system is working correctly, you should hear a clicking sound while the
igniter button is pushed and you should see a spark inside the igniter housing. If you do
not see the spark or hear a clicking sound, please check the following.
If the fire table lights, but will not stay lit, or remains lit only for a brief time, please check the
following.
2. If you still do not hear a clicking sound or see a spark in the
igniter housing, look under the fire table and make sure that the
electrode wire is correctly inserted into the back of the electronic
ignition box. While inspecting the electrode wire, make sure that
it is not cut or broken in any place. If the wire has been damaged
contact Real Flame at 1-800-654-1704 for a replacement.
3.) If you hear clicking but cannot see a spark in the igniter
housing, look under the table. Check between the electrode
wire connection at the back of the electronic ignition and the
connection point at the burn pan. If you see a spark anywhere
under the table, look for damage to the wire or an incomplete
connection at that point. If the wire has been damaged contact
Real Flame at 1-800-654-1704 for a replacement.
+
-
Back of
Electronic
Ignition
Electrode
Wire
Igniter
Housing
Burner
Tube
Do not cover
housing
CORRECT
INCORRECT
14
TIPS & TROUBLESHOOTING
If the fire table will not stay lit (Continued)
Other Common Problems
Make sure that the thermocouple and electrode
are correctly positioned.
The igniter housing has been removed from the
illustration to the right to better show positioning;
however, you should be able to look through
the openings of the igniter housing to verify this
without removing it.
Thermocouple - The thermocouple tip should
be located close to the burner, aligned with a
burn port so that flames contact it directly. Make
sure the flames are making contact with the
thermocouple tip.
Electrode - The electrode is where the spark is
generated to ignite your fire table. Make sure that
you can see this sparking when the igniter button
is pushed.
Damaged Thermocouple
If the igniter housing and the thermocouple tip are clear of debris and the flame is clearly contacting
the tip of the thermocouple, but the fire table will still not stay lit, the thermocouple may be
damaged. Look beneath the table and find the copper thermocouple wire coming out of the back of
the valve. Examine the length of it for any signs of damage. Sharp bends, kinks or damage can cause
the thermocouple to not function correctly. If you find damage to the thermocouple contact Real
Flame at 1-800-654-1704 for a replacement.
Clogged or Obstructed Burner
It is common for bugs, especially spiders, to make webs or nests inside of burner tubes. If it seems
like you are getting low or no gas flow, visually check all openings in the burner for signs of clogs. If
you see anything clogging the burner try using compressed air to remove the debris.
Out of Gas
Be sure that your tank is not empty. Low tanks can result in lower flames.
Cold Temperatures
Cold temperatures outside may result in lower tank pressures causing the flames to be lower. Do not
use your fire table in extreme temperature conditions. Allow the temperature of your tank to rise
and as the pressure in the tank increases the flame size will increase. NEVER heat your tank; allow it
to warm up naturally.
High Winds
Your fire table is designed to operate in winds up to 10 mph. High winds may cause the flame to
blow out. Do not operate your fire table in high wind conditions.
If you continue to have problems with your fire table please
contact Real Flame customer service at : 1-800-654-1704
Thermocouple
Make sure flame
is contacting this.
Electrode
You should see this
spark when pushing
the igniter button.
Igniter Housing
removed for visibility
15
TECHNICAL PARTS LIST
Burn Tube
100390001
Thermocouple
100210000
Igniter Electrode
and Igniter Ground
100380001
Orifice Spud
100370002
Bellows (CSST)
100370004
Valve
100370000
LP Hose and
Regulator
100190000
Control Knob
10040U000
Igniter Housing
N/A
Burn Pan
N/A
Natural Gas
Conversion Kit
000231095
Fire Table Body
N/A
Adjustable Feet
06000003
Ignition Assembly
100220000
16
WARRANTY & RETURN POLICIES
Warranty
Real Flame® Company warrants Real Flame fireplaces and accessories to be free from defects in parts
under normal use and service for a period of 1 year from the date of purchase and defective from finish
issues for a period of 90 days from the date of purchase. In the event of such defects Real Flame will,
at its option, replace the defective product or refund the purchase price. The foregoing is the exclusive
remedy and Real Flame disclaims all other warranties, including any implied warranty of merchantability
or fitness for a particular purpose. In addition, Real Flame will not be responsible for consequential
damages in excess of the purchase price of the product on which such liability is based.
Return Policy
You may return your purchase within 90 days of receipt. No refunds will be issued for incomplete or
unauthorized returns. All returned products must be 100% complete, adequately packaged in original
packaging and in resalable condition. Products that have been assembled or modified will not be eligible
for return. All items must be returned in their entirety, meaning all items included must be returned
together. No returns or exchanges on discontinued items. Please begin the return process by contacting
the store or company where you bought your Real Flame item.
Replacement Parts
In the event that an item has been lost or damaged, either by the manufacturer or in shipping, you
may request a replacement. Replacement parts are not available for all units and only given at Real
Flame’s discretion. We will assess any damage and find a solution, which could include shipping you a
replacement. No replacements are available for discontinued items or repackaged (open box) products.
Please call Real Flame Customer Service at 800-654-1704 for replacement parts before returning the
damaged item. Please have the following information (which can be found in your instruction manual)
ready before you call Customer Service.
Model Number of Item
4-8 digit Part Number
Lot Code Number
Shipping Address
A picture of the damaged item may be requested. Pictures should be sent to custserv@realflame.com
Incorrect Order Received
If you received something other than what you ordered, please contact Real Flame Customer Service at
800-654-1704 within 48 hours of receiving the item. Please refer to www.Realflame.com for our complete
return guidelines and policies.
Please refer to www.Realflame.com for our complete return guidelines and policies.
Real Flame®
7800 Northwestern Ave.
Racine, WI 53406
Customer Service: 1-800-654-1704 in USA
Service à la clientèle: 1-800-363-6443 in Canada
custserv@realflame.com
17
CT0011LP-GLS Ledgestone carré
AVERTISSEMENT
DANGER
MANUEL DU PROPRIÉTAIRE DE TABLE À FEU
!
!
Pour usage extérieur uniquement.
170822FT-171212
Si vous sentez du gaz:
• Arrêtez le gaz à l’appareil.
• Éteignez toute flamme nue.
Si l’odeur persiste, éloignez-
vous de l’appareil et appelez
immédiatement votre fournisseur de
gaz ou votre service des incendies.
AVERTISSEMENT
AVERTISSEMENT
!
!
Ne stockez pas ou n’utiliser pas de l’essence ou d’autres liquides
inflammables à proximité de cet appareil ou de tout autre appareil.
Une bouteille de GPL non connecté pour l’utilisation ne doit pas
être stockée à proximité de cet appareil ou d’un autre appareil.
L’installation, le réglage, l’altération, le service ou l’entretien inadéquat
peuvent causer des blessures ou des dommages matériels.
Lisez attentivement les instructions d’installation, d’utilisation et
de maintenance avant d’installer ou d’entretenir cet équipement.
18
Informations Importantes sur la Sécurité
Dangers et Avertissements sur les Gaz
Liste des Pièces
Instructions d’Assemblage
Instructions de Pré-utilisation
Instructions d’Éclairage
Entretien et Nettoyage
Avertissement sur les Araignée et les Insectes
Conseils et Dépannage
Liste des Pièces Techniques
Garantie
3
5
6
7
9
10
11
12
13
15
16
DANGER
!
CO Warning must be 12 pt bold
Check and update Specs
Verify Page numbers
Nom du Produit
Ledgestone carré Table à Feu
No. Du Modèle
CT0011LP-GLS
Puissance nominale
65,000 BTUs/hr
Type de Gaz
Propane (GPL)
Approvisionnement en Gaz
bouteille de GPL de 20 lb
SOMMAIRE
RISQUE DU MONOXYDE DE CARBONE
Cet appareil peut produire du monoxyde de
carbone qui n’a pas d’odeur.
L’utiliser dans un espace fermé peut vous tuer.
N’utilisez jamais cet appareil dans un espace fermé
tel qu’un camping-car, une tente, une voiture ou
une maison.
CARACTÉRISTIQUES
19
Notes d’installation
Avertissements Généraux
Distance Minimale de l’unité aux matériaux combustibles:
48” (121,9 cm) de tous les côtés et de l’arrière. Ne placez pas cette table à feu sous aucune structure
aérienne ou végétarienne. Ne la placez pas sur ou au-dessus des surfaces combustibles.
Gardez ces instructions pour référence ultérieure. Si vous assemblez cette unité pour quelqu’un
d’autre, donnez-leur ce manuel pour lire et sauvegarder pour référence ultérieure.
Si les informations contenues dans ce manuel ne sont pas suivies exactement, un incendie ou une
explosion peut entraîner des dommages matériels, des blessures corporelles ou le décès.
L’installation et l’entretien doivent être eectués par une agence de service qualifiée ou un fournisseur
de gaz. Real Flame recommande d’utiliser des professionnels certifiés aux États-Unis par le National
Fireplace Institute® (NFI) en tant que Spécialistes NFI du Gaz.
La pression d’entrée GPL normale pour cet appareil est de 11.0” W.C. (2,74 kPa), la pression d’entrée
maximale est de 13,0” W.C. (3,23 kPa), la pression d’entrée minimale est de 8” W.C. (1,99 kPa).
Si cette table à feu a été convertie au gaz naturel, la pression d’entrée normale pour cet appareil est
de 7,0” W.C. (1,74 kPa), la pression d’entrée maximale est de 10,5” W.C. (2.61kPa), la pression d’entrée
minimale est de 3,5” W.C. (0,87 kPa).
Ne retirez pas les pieds du foyer à feu.
Ne placez pas le foyer à feu sur tout ce qui bloque ou scelle l’espace entre le foyer et le sol. Ne fixez
pas de manière permanence le foyer à feu de quelque manière que ce soit ou à aucune surface.
N’enterrez pas le tuyau. Vous devez pouvoir inspecter visuellement le tuyau avant toute utilisation.
N’enroulez pas ou ne cachez pas le tuyau sous le foyer à feu. Le tuyau pourrait être endommagé s’il
touche des surfaces chaudes.
CLes enfants et les adultes doivent être informés des risques de températures de surface élevées et
doivent rester éloignés pour éviter les brûlures ou que leurs vêtements prennent feu.
Les jeunes enfants devraient être soigneusement surveillés dans la zone du foyer à feu.
Les vêtements ou autres matériaux inflammables ne doivent pas être accrochés au foyer à feu ou
placés sur ou à proximité de l’appareil.
Toute protection ou autre dispositif de protection retiré pour l’entretien du foyer à feu doit être
remplacé avant d’utiliser l’appareil.
L’installation et la réparation doivent être eectuées par une personne qualifiée. Le foyer à feu
doit être inspecté avant utilisation et au moins une fois par année par un technicien qualifié.
Un nettoyage plus fréquent peut être nécessaire si jugé nécessaire. Il est impératif que le
compartiment de commande, les brûleurs et les passages de circulation d’air de l’appareil soient
maintenus propres.
N’entreposez pas ou n’utilisez pas de l’essence ou d’autres vapeurs ou liquides inflammables à moins
de 25 pieds (7,62 m) de ce appareil ou de tout autre appareil.
Ne rangez pas de matériaux combustibles dans le boîtier du foyer à feu. Cela comprend les bouteilles
de GPL. Si le foyer à feu est conçu pour utiliser une bouteille de GPL dissimulé, la bouteille de GPL
doit être correctement fixé dans le porte-bouteille désigné sous le foyer. Ne stockez pas de bouteilles
de GPL supplémentaires sous le foyer à feu.
Assurez-vous de protéger le tuyau et ses composants de toutes surfaces chaudes. Il est dangereux de
permettre au tuyau d’entrer en contact avec une surface chaude.
Si vous utilisez votre à feu avec une bouteille de GPL, la bouteille ne doit jamais être utilisée ou
stockée sur son côté ou lorsqu’elle est renversée.
INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ
20
Avertissements Généraux (Suite)
Avertissements d’Installation
Avertissements en Cours d’Utilisation
Gardez toutes les parties du foyer à feu propres, y compris le brûleur et l’assemblage du tuyau. Pour
plus d’informations sur le nettoyage de votre table à feu, reportez-vous à la section Entretien et
Nettoyage de ce manuel.
N’utilisez pas cet appareil si une partie a été immergée. Appelez immédiatement un technicien de
service qualifié pour inspecter l’appareil et remplacer toute partie du système de contrôle et toute
commande de gaz qui a été sous l’eau.
N’utilisez pas cette table à feu pour la cuisson.
Ne versez pas d’eau dans le foyer à feu.
N’essayez pas de déplacer ou de ranger cette table à feu jusqu’à ce que toutes les pièces soient froides.
Coupez toujours l’alimentation en gaz à la source et débranchez le tuyau lorsque le foyer à feu n’est pas utilisé.
Toute modification de ce foyer à feu extérieure qui n’est pas spécifiquement dirigée dans le manuel du
propriétaire annulera la garantie du fabricant. Cela comprend l’utilisation de matériaux de remplissage
non approuvés.
Avant chaque opération, vérifiez l’assemblage du tuyau pour vous assurer qu’il n’y a pas trop
d’abrasion, d’usure ou de dommage. Utilisez un miroir portatif, si nécessaire, pour voir les sections de
tuyau situées sous l’appareil.
Si le flexible est endommagé, fissuré ou coupé, il doit être remplacé avant d’utiliser le foyer à feu.
Lensemble de tuyau doit être remplacé par un ensemble de tuyau spécifié par Real Flame. Veuillez
nous appeler au 1-800-654-1704 pour obtenir de l’assistance.
Placez le tuyau hors des sentiers où les gens peuvent trébucher dessus. Ne placez pas le tuyau dans
les endroits où il risque d’être endommagé accidentellement.
Avant chaque utilisation, examinez le brûleur et ses composants pour détecter la saleté et les
débris. Si le nettoyage est nécessaire, utilisez une brosse à tuyau et une solution d’eau savonneuse.
Examinez également la zone autour du brûleur. Toutes saletés ou matières étrangères telle que les
toiles d’araignées, les nids, les feuilles, etc., doivent être enlevées. S’il est évident que le brûleur est
endommagé, le foyer à feu ne doit pas être utilisé et le brûleur doit être remplacé. Veuillez contacter
Real Flame au 1-800-654-1704 pour obtenir de l’assistance.
Ne brûlez pas de combustibles solides comme le bois, les briquettes de charbon de bois, le
charbon de bois, les bûches fabriquées, le bois flotté, les déchets, les feuilles, le papier, le carton, le
contreplaqué, le bois peint ou traité.
NE LAISSEZ JAMAIS ce foyer à feu sans surveillance lorsqu’il est en cours d’utilisation.
L’utilisation d’alcool, de médicaments sur ordonnance ou en vente libre peut nuire à votre capacité à
utiliser ce foyer à feu en toute sécurité.
Utilisez toujours conformément à tous les codes locaux, étatiques et nationaux applicables. Contactez
votre service d’incendie local pour plus de détails sur la combustion en plein air.
Ne l’utilisez pas dans des conditions venteuses. Les vents supérieurs à 10 km/h peuvent éteindre la flamme.
Certaines surfaces de ce foyer à feu peuvent devenir chaud pendant l’utilisation. Faites attention et ne
touchez pas les surfaces De l’appareil jusqu’à ce qu’elles soient refroidies.
INFORMATIONS IMPORTANTES SUR LA SÉCURITÉ
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Real Flame CT0011LP Le manuel du propriétaire

Catégorie
Cheminées
Taper
Le manuel du propriétaire