Dometic COOLAIR SP 950I Guide d'installation

Taper
Guide d'installation

Ce manuel convient également à

AIR CONDITIONERS
COOLAIR
SP950I
Rear panel evaporator unit
Installation Manual . . . . . . . . . . . . . . . . . . 11
Rückwandverdampfereinheit
Montageanleitung . . . . . . . . . . . . . . . . . 30
Unité d'évaporateur pour paroi
arrière
Instructions de montage. . . . . . . . . . . . . 50
Evaporador para la pared trasera
Instrucciones de montaje . . . . . . . . . . . . 70
Unidade de evaporação para a
parede traseira
Instruções de montagem . . . . . . . . . . . . 90
Unità di evaporazione per parete
posteriore
Indicazioni di montaggio . . . . . . . . . . . . 110
Achterwandverdampereenheid
Montagehandleiding . . . . . . . . . . . . . . .131
Bagvægsfordamperenhed
Monteringsvejledning . . . . . . . . . . . . . 150
Bakväggsförångarenhet
Monteringsanvisning . . . . . . . . . . . . . . 168
Fordamperenhet for bakvegg
Monteringsanvisning . . . . . . . . . . . . . . . 187
Takaseinähaihdutinyksikkö
Asennusohje . . . . . . . . . . . . . . . . . . . . . 206
Блок испарителя на задней
стенке
Инструкция по монтажу . . . . . . . . . . . 224
Jednostka parownika tylnej ścianki
Instrukcja montażu . . . . . . . . . . . . . . . . 245
Jednotka výparníka určená na
zadnú stenu
Návod na montáž . . . . . . . . . . . . . . . . . 265
Výparníková jednotka na zadní
stěně
Návod k montáži. . . . . . . . . . . . . . . . . . 285
Hátfalrögzítésű párologtató
egység
Szerelési útmutató . . . . . . . . . . . . . . . . 304
EN
DE
FR
ES
PT
IT
NL
DA
SV
NO
FI
RU
PL
SK
CS
HU
SP950I--I-16s.book Seite 1 Mittwoch, 1. Februar 2017 8:14 20
SP950I--I-16s.book Seite 2 Mittwoch, 1. Februar 2017 8:14 20
3
CoolAir SP950I
145
278
648
1
1
2
3
2
3
SP950I--I-16s.book Seite 3 Mittwoch, 1. Februar 2017 8:14 20
CoolAir SP950I
4
2,10 m
4
5
SP950I--I-16s.book Seite 4 Mittwoch, 1. Februar 2017 8:14 20
5
CoolAir SP950I
6
7
SP950I--I-16s.book Seite 5 Mittwoch, 1. Februar 2017 8:14 20
CoolAir SP950I
6
8
1
2
3
4
9
SP950I--I-16s.book Seite 6 Mittwoch, 1. Februar 2017 8:14 20
7
CoolAir SP950I
0
SP950I--I-16s.book Seite 7 Mittwoch, 1. Februar 2017 8:14 20
CoolAir SP950I
8
a
b
134567
89
2
SP950I--I-16s.book Seite 8 Mittwoch, 1. Februar 2017 8:14 20
9
CoolAir SP950I
M
M
+ 24 V
–/ 0 V
ro sw
w
br
gr
gl
1
2
3
4
5
6
7
8
9
sw
sw
w
br
gr
gl
gl
sw
ro
w
sw
gr/gl
w
sw
gr
10
br
gr br w
gr/gl
c
SP950I--I-16s.book Seite 9 Mittwoch, 1. Februar 2017 8:14 20
CoolAir SP950I
10
br gl gr ro sw w
EN Brown Yellow Green Red Black White
DE Braun Gelb Grün Rot Schwarz Weiß
FR Marron Jaune Vert Rouge Noir Blanc
ES Marrón Amarillo Verde Rojo Negro Blanco
PT Castanho Amarelo Verde Cinzento Vermelho Preto
IT Marrone Giallo Verde Rosso Nero Bianco
NL Bruin Geel Groen Rood Zwart Wit
DA Brun Gul Grøn Rød Sort Hvid
SV Brun Gul Grön Röd Svart Vit
NO Brun Gul Grønn Rød Svart Hvit
FI Ruskea Keltainen Vihreä Punainen Musta Valkoinen
RU Коричневый Желтый Зеленый Красный Черный Белый
PL Brązowy Żółty Zielony Czerwony Czarny Biały
SK Hnedá Žltá Zelená Červe Čierna Biela
CS Hněda Žlutá Zelená Červená Černá Bílá
HU Barna Sárga Zöld Piros Fekete Fehér
SP950I--I-16s.book Seite 10 Mittwoch, 1. Februar 2017 8:14 20
11
EN
CoolAir SP950I
Contents
1 Symbols and formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.1 Using the device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.2 Handling electrical cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3 Conventions in this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.1 General information on the installation manual. . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.2 Target group. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 Proper use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.1 Prescribed installation method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.2 Notes on installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6.3 Determining the installation position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.4 Installing the evaporator unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.5 Sealing and attaching the cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.6 Routing supply lines to condenser unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
6.7 Connecting condenser unit to evaporator unit. . . . . . . . . . . . . . . . . . . . . . . . . . 23
6.8 Installing the electrical supply lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7 Configuration of unit software . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7.1 Starting and ending configuration mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.2 Menu level 1: Set temperature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.3 Menu level 2: Low voltage cut-off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.4 Menu level 3: Operating mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
7.5 Menu level 4: Default setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
7.6 Menu level 5: Temperature unit display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
SP950I--I-16s.book Seite 11 Mittwoch, 1. Februar 2017 8:14 20
EN
Symbols and formats CoolAir SP950I
12
1 Symbols and formats
!
!
A
I
2 Safety instructions
You must read the entire manual thoroughly and carefully.
We can only guarantee the reliability of the air conditioning roof unit if the
instructions are adhered to. The same applies to the prevention of injury and
damage to property.
The manufacturer accepts no liability for damage in the following cases:
Faulty assembly or connection
Damage to the product resulting from mechanical influences and excess
voltage
Alterations to the product without express permission from the manufacturer
Use for purposes other than those described in the operating manual
2.1 Using the device
The freedom of movement of semi-trailers (of the outer edges of the semi-
trailer when turning or jackknifing) and other vehicle attachments must not be
restricted.
Only use the parking cooler for the purpose specified by the manufacturer
and do not make any alterations or structural changes to the device.
Only operate the parking cooler if you are certain that the housing and the
cables are not damaged.
WARNING!
Safety instruction: Failure to observe this instruction can cause fatal or
serious injury.
CAUTION!
Safety instruction: Failure to observe this instruction can lead to injury.
NOTICE!
Failure to observe this instruction can cause material damage and impair the
function of the product.
NOTE
Supplementary information for operating the product.
SP950I--I-16s.book Seite 12 Mittwoch, 1. Februar 2017 8:14 20
13
EN
CoolAir SP950I Safety instructions
Installation, maintenance and repair work may only be carried out by
qualified personnel from a specialist company who are familiar with the
risks involved and the relevant regulations.
Do not use the parking cooler near flammable fluids or in closed rooms.
Do not reach into air grilles or ventilation nozzles or insert any foreign objects
in the system.
Do not open the system in the event of a fire. Use approved extinguishing
agents instead. Do not use water to extinguish fires.
Switch off the parking cooler before using automatic washing equipment
(automatic car washes etc.) to clean the vehicle.
Disconnect all connections to the power supply when carrying out work on
the device.
The system must be switched off before you tilt the cab.
2.2 Handling electrical cables
The electrical cables might be laid over sharp edges. Use ducts or tubes to
prevent damage.
Do not lay loose or bent cables next to electrically conductive materials
(metal).
Do not pull on the cables.
Attach and lay the cables in such a manner that they cannot be tripped over
or damaged.
The electrical power supply may only be connected by a specialist work-
shop.
Fit a fuse of 25 A to the connection to the vehicle's power supply.
Never lay power supply lines (battery leads) in the vicinity of signal or control
cables.
SP950I--I-16s.book Seite 13 Mittwoch, 1. Februar 2017 8:14 20
EN
Conventions in this manual CoolAir SP950I
14
3 Conventions in this manual
3.1 General information on the installation manual
This installation manual contains the essential information and instructions for
installing the parking cooler. The information is intended to be read by the
installation personnel of the parking cooler.
The following instructions are intended to help you use the installation manual
properly:
The installation manual is part of the scope of delivery and should be stored
carefully.
The installation manual provides you with important information on the
installation of the device and can also be used as a reference material in the
event of repairs.
The manufacturer assumes no liability for non-observance of this installation
manual. Any claims are excluded in this case.
3.2 Target group
The installation and configuration information in this manual is intended for
qualified installation personnel who are familiar with the guidelines and safety
precautions to be applied during the installation of lorry accessory parts.
4Proper use
The CoolAir SP950 parking cooler is designed for supplying the cab of a lorry
with cooled and dehumidified air. It can be used while driving.
The CoolAir SP950I rear panel evaporator unit (ref. no. 9105305612) can only
be operated in combination with a CoolAir SP950C condenser unit. Both
components together form the CoolAir SP950 parking cooler.
A
I
NOTICE!
The CoolAir SP950 parking cooler is not suitable for installation in agri-
cultural machines and construction machines or similar equipment. It does
not work properly in the event of strong vibrations and exposure to dust.
Operating the SP950 parking cooler with voltages other than those
specified can result in damage to the device.
NOTE
The SP950 parking cooler is only designed for ambient temperatures of up to
43 °C.
SP950I--I-16s.book Seite 14 Mittwoch, 1. Februar 2017 8:14 20
15
EN
CoolAir SP950I Scope of delivery
5 Scope of delivery
Material for strain relief of condenser unit's connection
cable (24 V)
Part designation Quantity Ref. no.
Evaporator unit with connecting cable 1 9105305612
Remote control (incl. type CR2025 battery) 1 4441600159
Corrugated pipe holder 4 4443900298
Cover for corrugated pipe holder 4 4443900314
Lock nut M6 4
Washer M6 (d1 = 6.4 mm, d2 = 20 mm) 8
Edge protection 1
Plastic spacer L = 25 mm 4
Plastic spacer L = 40 mm 8
Hexagon screw M6 x 40 4
Hexagon screw M6 x 110 4
Hood for rear panel 1
Self-tapping screw 3.5 x 9.5 mm 4
Operating manual 1 4445100724
Installation manual 1 4445100875
Evaporator unit installation template 1
Part designation Quantity
Fastening holder 1
Clamp Ø 10 mm 1
Screw M6 x 16 1
Washer M6 2
Lock nuts M6 1
SP950I--I-16s.book Seite 15 Mittwoch, 1. Februar 2017 8:14 20
EN
Installation CoolAir SP950I
16
6 Installation
A
6.1 Prescribed installation method
The condenser unit (fig. 2 2, page 3) is attached to the firm and straight rear
panel of the cab or by means of a firm fastening frame. The evaporator unit
(fig. 2 1, page 3) is fitted on the inside of the rear panel of the cab.
The evaporator unit must be installed in an upright position (fig. 3, page 3).
I
The parking cooler consists of the following components (fig. 2, page 3):
CoolAir SP950C condenser unit (1)
CoolAir SP950I rear panel evaporator unit (2) with connecting line (3)
NOTICE!
The parking cooler may only be installed by qualified personnel from a
specialist company. The following information is intended for specialists who
are familiar with the guidelines and safety precautions to be applied.
NOTE
The connection line (fig. 2 3, page 3) can only be installed after fitting the
evaporator unit and the condenser unit.
SP950I--I-16s.book Seite 16 Mittwoch, 1. Februar 2017 8:14 20
17
EN
CoolAir SP950I Installation
6.2 Notes on installation
!
!
I
You should always read this installation manual all the way through before
installing the parking cooler.
You should always observe the following tips and information when installing the
parking cooler:
Please consult the manufacturer of your vehicle with regard to the following.
is the cab's rear panel a suitable location for attaching the unit?
is the body designed to bear the static weight and loads occasioned by
the parking cooler in a moving vehicle?
You can use fig. 1, page 3 to check the dimensions of the installed unit.
Always check before installation of the unit whether any vehicle components
could be damaged, deformed or impaired in terms of their functionality as a
result of the installation.
Avoid any unnecessary and frequent mechanical stress to the supply line
between the evaporator unit and the condenser unit. Damage can result in
the loss of refrigerant and impair the performance of the unit.
The supplied assembly parts must not be modified during installation.
The ventilation slots (grill) may not be covered (minimum distance from other
attachment parts: 10 cm).
WARNING! Danger of electrocution!
Detach all connections to battery before starting installation of parking
cooler.
Make sure that all electrical components are electrically discharged before
carrying out work on them!
CAUTION!
Improper installation of the air conditioning roof unit can result in irreparable
damage to the device and put the safety of the user at risk.
The manufacturer will not be held liable for claims if the air conditioning roof
unit is not installed according to this installation manual. That applies to
malfunctions and the safety of the air conditioning roof unit, in particular to
injuries and damage to property.
NOTE
The manufacturer strongly recommends the use of a vehicle-specific
fastening frame for an optimum installation procedure for the SP950C
condenser unit on the rear panel of the cab.
Following installation of the unit, the specified unit software parameters
must then be checked (chapter “Configuration of unit software” on
page 24).
SP950I--I-16s.book Seite 17 Mittwoch, 1. Februar 2017 8:14 20
EN
Installation CoolAir SP950I
18
You can connect the unit to the battery via the lorry's terminal block or
directly. The terminal block is to be preferred for the connection. On some
vehicles, larger consumers connected to the terminal block are switched off
after a short while if the power requirement is too high. Ask your vehicle
manufacturer for the specifications of the terminal block.
Observe the body manufacturer's guidelines with regard to installation of the
unit and its electrical connection.
Pay attention to the connection plan for the device:
6.3 Determining the installation position
The system's installation position must meet the following criteria:
All maintenance work must be easy to perform.
Sufficient space must be available for the refrigerant line.
The condenser unit must be installed in an upright position.
Observe the maximum permissible inclination angle at the side and to the
front when in operation (fig. 3, page 3).
The refrigerant line must be long enough (approx. 2.1m) for connection of
the condenser and evaporator unit. The line must not be routed under
tension (fig. 4, page 4).
The fastening surface should be as flat as possible. Use spacer sleeves for
uneven surfaces. If spacer sleeves are used, appropriately longer fastening
screws with sufficient tensile strength (not included in the assembly set) must
then be used.
No. in
fig. c, page 9
Designation
1Evaporator fan
2 Operating circuit board
3 Temperature sensor
4Control unit
525A fuse
6 4 A fuse vaporiser fan
7 4 A fuse condenser fan
8Condenser fan
9Compressor
10 Klickson (compressor)
SP950I--I-16s.book Seite 18 Mittwoch, 1. Februar 2017 8:14 20
19
EN
CoolAir SP950I Installation
I
6.4 Installing the evaporator unit
The evaporator unit is fitted on the cab's rear panel, near the bunk, in a horizontal
position:
Remove the panelling from the evaporator unit (fig. 5, page 4).
Pull the housing back slightly and detach the connecting plug from the
control panel's connection cable (fig. 6, page 5).
Find a suitable fastening position in the cab that allows sufficient air
circulation.
A
Use the drill template included to determine the position of the evaporator
unit. Position the template at the selected point and use a felt pen to mark the
positions of the four holes (Ø 6.5 mm) for fastening.
Mark the positions of the holes for feeding through the connection line
(Ø 48 mm) and the condensation line (Ø 15 mm).
NOTE
The fastening screws M6 x 40 mm included are designed for use with the
spacer sleeves, l = 25 mm, (e.g. MAN TGX).
The fastening screws M6 x 110 mm included are designed for use with the
spacer sleeves, l = 40 mm, (e.g. Volvo FH as of construction year 2013) (two
spacer sleeves for each screw).
By combining the spacer sleeves, different distances between the rear wall of
the cab and inner trim can be achieved.
The screw overhang beyond the nut must not exceed 15 mm.
If spacer sleeves are not to be used or if other ones are to be used, the fastening
screws have to then be adapted to match them. Otherwise the unit housing
may be damaged.
NOTICE!
Make sure that the drill template included is not upside down when
positioned!
You can position the drill template from the inside or from the outside onto
the cab. Make sure that the following holes are used for the connecting and
condensation line:
– from inside: holes that bear the inscription “Inside
– from outside: holes that bear the inscription “Outside
SP950I--I-16s.book Seite 19 Mittwoch, 1. Februar 2017 8:14 20
EN
Installation CoolAir SP950I
20
I
Drill at the marked positions using appropriate drill bits.
A
Carefully unwind the connection line.
To fit the evaporator unit in place, route the connection line through the hole
with Ø 48 mm and the condensation line through the hole with Ø 15 mm.
Fit edge protection to the holes with a diameter of Ø 48 mm.
Position the cable grommet for the PVC hose so that this is protected against
any sharp edges on the hole.
If spacer sleeves are used, drill large holes in the interior trim to accommo-
date them.
Insert the matching screws and washers using sealant from the outside.
Tighten the evaporator unit from the outside using the lock nuts M6 and
washers M6 (fig. 7, page 5).
Connect the connection cable of the control panel to the connecting plug in
the housing.
Use the previously removed hex screws to fasten the housing of the
evaporator unit.
NOTE
Before drilling, check the position of the drill template and the marked
holes.
If the space between the interior trim and the cab's rear panel is large, the
hole (Ø 15 mm) for the inclined condensation line must be drilled slightly
lower than specified on the template. For a distance for the interior trim to
the cab's rear panel of approx. 25 mm the hole (Ø 15 mm) should be drilled
approx. 5 mm lower to ensure that the condensation drainage process
functions.
NOTICE!
Make sure that the coupling half with the thin, capillary tube is not twisted or
kinked.
SP950I--I-16s.book Seite 20 Mittwoch, 1. Februar 2017 8:14 20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324

Dometic COOLAIR SP 950I Guide d'installation

Taper
Guide d'installation
Ce manuel convient également à