Modern Forms WS-58814 Tower Mode d'emploi

Taper
Mode d'emploi
1
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”
the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts that are worn out
or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les règlements
locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt
(« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDEs
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, nen laissez pas de côté et
ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler l’homologation ETL/CETL du luminaire.
MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e instalación de esta
lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de alimentación principal
en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la instalación ni
utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación ETL/CETL esta lámpara.
PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la base sólo.
HARDWARE
Wire Connector
Qty: 3pcs+1 Extra
7EAC112201
A
Conversion plate
QTY:1Extra
4MBC111121BB1
Brass Plating
D
Mounting Screw
Qty: 1 Extra
4MPF0412S1BB1
5/32”-32 × 1/2
Brass Plating
C
Junction Box Screw
Qty: 4pcs+1 Extra
7MPF0825F1
#8-32x1
Nickle Plating
Mounting Ring
QTY:1Extra
7MBC101501
Plastic Anchor
QTY:6pcs+1Extra
7TDD082401
Wood Screw
QTY:6pcs+1Extra
7MPF2204J2 (Ni)
Ø4x7/8”
B E F G
G0
INSTALLATION INSTRUCTION
588 – LED Wall Sconce
WS-58814 / WS-58820 / WS-58827
2
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program.
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture,
including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear
area. Be careful not to lose any small parts necessary for installation.
MOUNT ON 2X4 SWITCH BOX (Fig. 1)
3. Remove the mounting screw (C) as shown in Fig. 1.
4. Drill holes in the wall aligned with the key holes located in the
mounting back plate, insert the plastic anchor (E1).
5. Secure the mounting plate to the switch box using junction box screws
(B). Fasten it to the wall with wood screw (F1), the side of the mounting
plate marked “GND” must face out.
6. Connect the xture’s wire to switch box wires as shown in Fig. 3,
making sure that all wire connectors (A) are secured. If your outlet box
has a green or bare copper ground wire, connect the xtures ground
wire to it. Otherwise, connect the xtures ground wire directly to the
back plate using the green screw provided. After wires are connected,
tuck them carefully inside the switch box.
7. Place the bubble crystal on the xture as shown in Fig. 1. Place the top
cover on the xture as shown, then secure it using the mounting screw
(C).
8. Secure the xture to the mounting plate using the mounting screw (C).
MOUNT ON 4X4 JUNCTION BOX (Fig. 2)
3. Remove the mounting screw (C) as shown in Fig. 1.
4. Drill holes in the wall aligned with the key holes located in the
mounting back plate, insert the plastic anchor (E1).
5. Secure the mounting ring to the junction box using the junction box
screws (B). Fasten it to the wall with wood screw (F1), The side of the
mounting ring (E) marked “GND” must face out.
6. Secure the mounting plate and conversion plate to the mounting
ring(E) using junction box screws (B) as shown in Fig. 2.. The side of the
mounting plate marked “GND” must face out.
7. Connect the xture’s wire to junction box wires as shown in Fig. 3,
making sure that all wire connectors (A) are secured. If your outlet box
has a green or bare copper ground wire, connect the xtures ground
wire to it. Otherwise, connect the xtures ground wire directly to the
back plate using the green screw provided. After wires are connected,
tuck them carefully inside the switch box.
8. Place the bubble crystal on the xture as shown in Fig. 1. Place the top
cover on the xture as shown, then secure it using the mounting screw
(C).
9. Secure the xture to the mounting plate using the mounting screw (C).
INSTALLATION INSTRUCTION
588 – LED Wall Sconce
WS-58814 / WS-58820 / WS-58827
G0
Fig.1 Mount on Switch Box
Fig.2 Mount on Junction Box
Mounting Backplate Conversion Plate Dimension Mounting Ring Dimension
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig. 3 Wiring
`
^
E
_
Mounting Screw
Wood Screw
Plastic Anchor
Wire Connector
Junction Box Screw
Mounting Screw
Bubble Crystal
(RPL-GLA-58814)
(RPL-GLA-58820)
(RPL-GLA-58827)
Top Cover
Switch Box
Ground Wire
Mouting Plate
Fixture
Ground Wire
Junction Box
Junction Box Screw
Wire Connector
Mounting Ring
Conversion Plate
Mounting Plate
C
G
F
A
B
B
B
A
E
D
41/2"
41/2"
11/2"
41/2"
13/8"
13/4"
4"
57[21/4"]
13/4"11/2"
WS-58814126/8"
WS-58820187/8"
WS-58827243/8"
t pJ RUUNQWTj _` PORTMN
t pJ RUUOMWTj _` QURTMN
t pJ RUUOTWTj _` RMRTMN
WS-58814 12 6/8”
WS-58820 18 7/8”
WS-58827 24 3/8”
WS-58814:7MBC325701
WS-58820:7MBC485701
WS-58827:7MBC505701
57 [2 1/4”]
1 1/2” 1 3/4”
4 1/2” 4 1/2”
4 1/2”
1 1/2”
4MBC111121BB1 7MBC101501
1 3/8”
1 3/4”
4”
1Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
OVERALL COMPONENT DIMENSIONS
CAUTION: TO PREVENT ELECTRICAL SHOCK, ENSURE ELECTRICITY HAS BEEN TURNED OFF AT THE CIRCUIT BREAKER BEFORE
BEGINNING.
-Read all instructions before installing.
-System is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
-When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
-Retain installation instructions for future maintenance reference.
WARNING: All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or
accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms
could result in personal injury or property damage, and will void the warranty. Contact an authorized dealer or the manufacturer if any parts are
damaged or missing.
MISE EN GARDE: POUR ÉVITER TOUT CHOC ÉLECTRIQUE, ASSUREZVOUS QUE LE DISJONCTEUR SOIT MIS HORS TENSION AVANT DE
COMMENCER.
-Lisez toutes les instructions avant l’installation.
-Le système doit être installé par un électricien licensié conformément au code national de l’électricité (NEC), et également aux règlements
locaux.
-Lors de la manipulation du luminaire, n’appuyez pas sur les LED. Tenez-le uniquement par la base.
ATTENTION: Toutes les pièces doivent être utilisées comme indiqué dans ces instructions. Ce produit est conçu pour être utilisé seulement avec
les pièces et/ou accessoires fournis pour être utilisés avec les produits Modern Forms. Remplacer des pièces ou accessoires non conçus pour ce
produit Modern Forms pourrait causer des dommages corporels ou matériels et pourrait également causer l’annulation de la garantie. Veuillez
contacter un revendeur autorisé ou le fabricant si des pièces manquent ou sont endommagées.
COMPONENT OVERVIEW
The trimless junction box cover is intended for installation to NEC approved 4” square junction boxes recessed in drywall and ush with the
support structure. It may be covered with spackle and/or plaster to conceal junction box visibility. It is to be connected to compatible Modern
Forms xtures. Refer to specications sheets for more information.
2"
#8
TYP
HARDWARE
Wire Connector
Qty: 3 (+1 Extra)
½” Plastic Spacer
Qty: 2
⁄”-40 x 1⁄” Long
Mounting Screw
Qty: 2 (+1 Extra)
¾” Plastic Spacer
Qty: 2
A
D
B
E
#8-32 x ¾” Long
Junction Box Screw
Qty: 2 (+1 Extra)
1” Plastic Spacer
Qty: 2
C
F
NOTE: This accessory is supplied with an optional mounting C-ring for
xture connection via ⁄” K.O. hole. This component may be omitted
from the installation if mounting xtures using #8 screw holes.
2Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIG. 1
FIG. 2
FIG. 4
TRIMLESS JUNCTION BOX COVER INSTALLATION:
The trimless junction box cover is compatible with NEC approved
4” square junction boxes recessed in drywall and ush with the
support structure.
1. Install compatible junction box (by others) to the framing
structure. Ensure the junction box is ush with the base or front
of framing structure (See FIG. 1).
2. Install the mounting plate to the junction box (See FIG. 2).
Ensure the spacer alignment base is facing outward.
FIG. 3
105mm
105mm
FIG. 5 FIG. 6
3. Determine the drywall thickness and select the appropriate
spacer to install between the mounting plate and the trimless
junction box cover (See FIG. 3).
NOTE: Only 1 matching pair of spacers are to be used per
installation.
4. Using the mounting screws provided, attach the trimless
junction box cover to the mounting plate (See FIG. 4).
5. Make a 4⁄” square cutout in drywall at the intended trimless
junction box cover location and proceed to install to framing
structure (See FIG. 5). Apply and nish spackle up to the center
hole of trimless junction box cover. Ensure #8 holes on the
cover are free of spackle. (See FIG. 6).
Mounting Plate
Plastic
Spacers
Trimless Junction Box Cover
Cover Mounting Screws
Ground Wire
Example: ½” Drywall (No Spacer)
⁄”½”
Spacer Alignment
Base
Spacer
Height
Drywall
Thickness
No Spacer ½”
½” ⁄”
¾” 1”
1” 1¼”
Junction Box
Screws
CB
D
E
F
3Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JAN 2023 G0
modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive
Port Washington, NY 11050
Central Distribution Center
1600 Distribution Ct
Lithia Springs, GA 30122
Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760
INSTALLATION INSTRUCTION
Trimless Junction Box Cover
MKCP-3040-WT
FIXTURE INSTALLATION TO JUNCTION BOX COVER:
The trimless junction box cover features two #8 holes which may be used to mount xtures:
1. Make appropriate splice connections. Wiring may be placed inside the xture or pushed into the junction box.
2. Using #8 mounting screws supplied with the lighting xture, attach the xtures to the #8 holes on the trimless junction box cover. Apply
xture cover or lensing (where applicable) to complete the installation. (See FIG. 7).
Fixture #8 Mounting Screws
FIG. 7
Wire Connector
A
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Modern Forms WS-58814 Tower Mode d'emploi

Taper
Mode d'emploi

dans d''autres langues