Manual No. 80079139 Revision A
Outdoor Portable Generator
Operator’s Manual
Model Number _____________________________
Revision __________________________________
Serial Number ______________________________
Date Purchased ____________________________
Copyright © 2019. Briggs & Stratton Corporation
Milwaukee, WI, USA. All rights reserved.
BRIGGSandSTRATTON.COM
Not for
Reproduction
2 BRIGGSandSTRATTON.COM
Equipment Description
Table of Contents
Equipment Description.........................2
Features and Controls .........................5
Operation....................................7
Maintenance ................................12
Storage ....................................15
IC Compliance Statement .....................15
Troubleshooting/Specifications .................16
Warranty ...................................18
Register Your Product
To ensure prompt and complete warranty coverage, register your
product online at www.onlineproductregistration.com.
Symbols and Meanings
Signal Meaning
DANGER
Indicates a hazard which, if not avoided, will
result in death or serious injury.
WARNING
Indicates a hazard which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a hazard which, if not avoided,
could result in minor or moderate injury.
NOTICE
Indicates information considered important,
but not hazard-related.
Symbol Name Explanation
Safety Alert
Symbol
Indicates a potential personal
injury hazard.
Operator’s
Manual
Failure to follow warnings,
instructions and operator’s manual
could result in death or serious injury.
Toxic Fumes
Engine exhaust contains carbon
monoxide, a poisonous gas that
will kill you in minutes. You cannot
smell it or see it.
Fire
Fuel and its vapors are extremely
flammable which could cause
burns or fire resulting in death or
serious injury.
Engine exhaust could cause fire
resulting in death or serious injury.
Electric
Shock
Generator could cause electrical
shock resulting in death or serious
injury.
Hot Surface
Muffler could cause burns or
resulting in serious injury.
WARNING! This product can expose you to
chemicals including gasoline engine exhaust, which
is known to the State of California to cause cancer,
and carbon monoxide, which is known to the State of
California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
Equipment Description
Read this manual carefully and become familiar with
your outdoor generator. Know its applications, its
limitations, and any hazards involved. Save these
original instructions for future reference.
The outdoor generator is an engine-driven, revolving field,
alternating current (AC) generator equipped with a voltage
regulator. The generator is designed to supply electrical
power for operating compatible electrical lighting, appliances,
tools and motor loads. The voltage regulator within the
generator is designed to automatically maintain output
voltage level.
The portable generator produces power that can be used
for outdoor items using extension cords or for first time
temporary home power restoration. Before your next home
power outage, install a listed transfer switch. A transfer switch
is a separate device installed by a licensed electrician that
allows the portable generator to be cord connected, using the
locking receptacle, directly into your home’s electrical system.
Extension cords connected to the portable generator’s
control panel are not intended to be a long term solution
when connected to items inside your home.
Every effort has been made to ensure that the information
in this manual is both accurate and current. However, the
manufacturer reserves the right to change, alter or otherwise
improve the generator and this documentation at any time
without prior notice.
NOTICE If you have questions about intended use, contact
an authorized service dealer. This equipment is designed to
be used with Briggs & Stratton® authorized parts only.
This spark ignition system complies with the Canadian
standard CAN ICES-2/NMB-2.
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on the
AC output receptacles. The system ground is connected to the
AC neutral wire (the neutral is bonded to the generator frame).
Special Requirements
There may be Federal or State regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.
This generator is not intended to be used at a construction site
or similar activity as defined by NFPA 70-2017 (NEC) section
590.6.
Not for
Reproduction
3
Equipment Description
To Restore Power Using Extension Cords
1. Only use grounded cords marked for outdoor use
rated for your loads.
To provide power using
extension cords
Total
Amperage
Minimum Guage, Outdoor Rated
Up to 50 FT (15 M) Up to 100 FT (30 M)
Up to 13A
16
14
Up to 15A
14
12
Up to 20A
12
10
2. Follow cord safety instructions.
3. Install carbon monoxide alarm(s).
4. When operating generator with extension cords, make
sure it is located in an open, outdoor area, at least 20
ft. (6.1 m.) from occupied spaces with exhaust pointed
away.
5. Extension cords running directly into home, powering
indoor items IS NOT RECOMMENDED.
DANGER! Engine exhaust contains carbon
monoxide, a poisonous gas that will kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Extension cords running directly into the home
increase your risk of carbon monoxide poisoning
through openings.
If an extension cord running directly into the home is
used to power indoor items, the operator recognizes
that this increases the risk of CO poisoning to people
inside the home and assumes that risk.
6. Install a listed* transfer switch as soon as possible
if generator will be used to provide home power
restoration.
To Restore Home Power Using a Listed
Transfer Switch
Connections to your home’s electrical system must use a
listed transfer switch installed by a licensed electrician. The
connection must isolate the generator power from the utility
power and comply with all applicable laws and electrical
codes. Power your home with a 20 Amp transfer switch
system.
120/240V
Outlet
Transfer
Switch
Typical Indoor Items
120V
OUTLET
* Certified by a Nationally Recognized Testing Laboratory
that the product complies to appropriate product safety test
standards.
Not for
Reproduction
4 BRIGGSandSTRATTON.COM
Equipment Description
Air Cleaner — Filters engine intake air.
Choke Lever — Used when starting a cold engine.
Engine Identification — Provides model, type and code of engine.
Fuel Cap — Add unleaded fuel here.
Fuel Valve — Used to turn fuel supply on and off to engine.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Identification Label — Provides model and serial number of
generator.
Oil Drain Plug — Drain engine oil here.
Oil Fill Cap/Dipstick — Check and add engine oil here.
Recoil Starter — Used to start the engine manually.
Spark Arrester Muffler/Exhaust — Lowers engine noise and is
equipped with a spark arrester screen.
Engine Identification
Oil Fill Cap/Dipstick
Oil Drain Plug
Fuel Cap
Grounding Fastener
Choke Lever
Air Cleaner
Identification Label
Fuel Valve
Recoil Starter
Spark Arrester Muffler/Exhaust
Not for
Reproduction
5
Features and Controls
120 Volt AC, 20 Amp, GFCI Duplex Receptacle — Used
to supply 120 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
120/240 Volt AC, 20 Amp Locking Receptacle — Used
to supply 120/240 Volt AC, single phase, 60 Hz power for
electrical lighting, appliance, tool and motor loads.
CO Guard™ Carbon Monoxide (CO) Shutdown Indicator
Light — Indicates the engine shutdown due to carbon
monoxide accumulation around the generator or a CO
Guard system fault occurred.
Main Breaker — The receptacles are provided with a
rocker switch main circuit breaker to protect the generator
against electrical overload.
Engine Switch — Set this switch to on (I) before starting
engine. Set switch to off (0) to shut off engine.
Low Oil Shutdown — This unit is equipped with a low oil
protection device. Oil must be at proper level for engine
to run. If the engine oil drops below a preset level, an oil
switch will stop the engine. Check oil level with dipstick.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and product warnings.
120/240 Volt AC, 20 Amp
Locking Receptacle
120 Volt AC, 20 Amp
GFCI Duplex Receptacle
Main Breaker
Engine Switch
Low Oil
Shutdown
CO Guard™
Carbon Monoxide
(CO) Shutdown
Indicator Light
Not for
Reproduction
6 BRIGGSandSTRATTON.COM
Features and Controls
Exhaust/muffler
Point away from home
Not for
Reproduction
7
Operation
Operation
Step 1: Safe Location
Before starting the portable generator there are two equally
important safety concerns regarding carbon monoxide
poisoning and fire that must be addressed.
Operation Location to Reduce the Risk of
Carbon Monoxide Poisoning
The engine exhaust of all fossil fuel burning equipment,
such as a portable generator, contains carbon monoxide, a
poisonous gas that will kill you in minutes. You cannot smell
it, see it, or taste it. Even if you do not smell exhaust fumes,
you could still be exposed to carbon monoxide gas.
By law it is required in many states to have a carbon
monoxide alarm in operating condition in your home.
A carbon monoxide alarm is an electronic device that
detects hazardous levels of carbon monoxide. When there
is a buildup of carbon monoxide, the alarm will alert the
occupants by flashing visual indicator light and alarm.
Smoke alarms cannot detect carbon monoxide gas.
DANGER! Engine exhaust contains carbon
monoxide, a poisonous gas that will kill you in
minutes. You cannot smell it, see it, or taste it.
Even if you do not smell exhaust fumes, you could still be
exposed to carbon monoxide gas.
Operate portable generator only outdoors, at least
20 ft. (6.1 m) from occupied spaces with exhaust
pointed away to reduce the risk of carbon monoxide
accumulating.
Install battery-operated carbon monoxide alarms or
plug-in carbon monoxide alarms with battery back-up
according to the manufacturer’s instructions. Smoke
alarms cannot detect carbon monoxide gas.
Do not run portable generator inside homes, garages,
basements, crawlspaces, sheds, or other partially-
enclosed spaces even if using fans or opening doors
and windows for ventilation. Carbon monoxide can
quickly build up in these spaces and can linger for
hours, even after this product has shut off.
If you start to feel sick, dizzy, weak, or your homes carbon
monoxide alarm sounds while using this product, get to
fresh air right away. Call emergency services. You may have
carbon monoxide poisoning.
To better educate yourself about all carbon monoxide risks,
go to www.takeyourgeneratoroutside.com.
Prevent Carbon Monoxide (CO) Poisoning
Use outdoors at least 20 ft. (6.1 m) from any home.
Point exhaust away from all homes and occupied
spaces.
Install CO alarms inside your home.
Carbon Monoxide Alarm(s)
Install carbon monoxide alarm
inside your home. Without
working carbon monoxide alarms,
you will not realize you are getting
sick and dying from carbon
monoxide poisoning.
20 ft. (6.1 m) min.
Not for
Reproduction
8 BRIGGSandSTRATTON.COM
Operation
Operation Location to Reduce the Risk of Fire
WARNING!
Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank
causing a fire, resulting in death or serious injury.
Portable generator must be at least 5 ft. (1.5 m) from any
structure, overhang, trees, shrubs, or vegetation over 12
in. (30.5 cm) in height.
• Do not place portable generator under a deck or other
type of structure that may confine airflow. Smoke alarm(s)
must be installed and maintained indoors according to the
manufacturer’s instructions/recommendations.
• Carbon monoxide alarms cannot detect smoke.
• Do not place portable generator in manner other than
shown.
MUFFLER
5 ft. (1.5 m) min.
5 ft. (1.5 m) min.
20 ft. (6.1 m) min.
Not for
Reproduction
9
Operation
Step 2: Oil and Fuel
Fuel must meet these requirements:
• Clean, fresh, unleaded fuel with a minimum of 87 octane.
Gasoline with an ethanol content up to 10% is acceptable.
E10
E15
NOTICE Do not mix oil in fuel or modify engine to run on
alternate fuels. Use of unapproved fuels could damage
engine and will not be covered under warranty.
See High Altitude for 5,000 ft. and above.
WARNING! Fuel and its vapors are extremely
flammable which could cause burns or fire
resulting in death or serious injury.
• Do not refuel during operation.
• Do not smoke during refueling.
• Turn engine off and let it cool at least 2 minutes before
removing fuel cap.
• Fill fuel tank outdoors. Keep fuel away from sparks, open
flames, pilot lights, heat, and other ignition sources.
Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
1. Move generator outdoors to a flat, level surface.
2. Clean area around oil fill and remove oil fill cap/dipstick.
3. Slowly pour contents of oil bottle into oil fill opening.
Checking oil level frequently, fill to point of overflowing.
NOTICE Pause to permit oil to settle. Wipe dipstick clean
each time oil level is checked. DO NOT overfill.
4. Replace and fully tighten oil fill cap/dipstick.
5. Slowly remove fuel cap to relieve pressure in tank.
6. Slowly add unleaded fuel to fuel tank. Be careful not
to fill above bottom lip. This allows adequate space for
fuel expansion.
7. Install fuel cap and let any spilled fuel evaporate
before starting engine.
High Altitude
At altitudes over 5,000 ft. (1524 m), a minimum 85 octane
fuel is acceptable. To remain emissions compliant, high
altitude adjustment is required. Operation without this
adjustment will cause decreased performance, increased
fuel consumption,
and increased emissions.
See an authorized Briggs & Stratton dealer for high altitude
adjustment information. Operation of the engine at altitudes below
2,500 ft. (762 m) with the high altitude kit is not recommended.
Transporting
When transporting equipment with a vehicle or trailer, turn fuel
shutoff valve to off (0) position. Do not tip engine or equipment at
an angle which causes fuel to spill.
Step 3: Generator Start Up
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is outdoors on a level surface.
NOTICE Failure to operate the unit on a level surface may cause
the unit to shut down.
2. Turn the fuel valve to the on (I) position.
3. Push choke lever to choke ( ) position.
4. Set engine switch to on (I) position.
5. Grasp recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly to start engine.
6. Slowly move choke lever to run ( ) position. If engine
falters, move choke lever to half choke position until
engine runs smoothly, and then to run ( ) position.
NOTICE If engine starts but fails to run, see Low Oil
Shutdown
in Features and Controls.
Fuel Valve
Choke Lever
Engine Switch
Not for
Reproduction
10 BRIGGSandSTRATTON.COM
Operation
Step 4: Connecting Electrical Loads
Using Extension Cords
Use only grounded extension cords marked for outdoor use
rated for your loads. Follow cord safety instructions.
WARNING! Damaged or overloaded extension
cords could overheat, arc, and burn resulting in
death or serious injury.
NOTICE For generator output required see Generator
Capacity. Connect electrical loads in off position then turn
on for operation.
120 Volt AC, 20 Amp, GFCI Duplex Receptacle
Use this receptacle to operate 120 Volt AC, single-phase, 60
Hz electrical loads requiring up to 2,400 Watts (2.4 kW) at
20 Amps of current.
Ground Fault Protection
The duplex receptacle is equipped with Ground Fault
Circuit Interrupter (GFCI) protection. The GFCI protects
against electrical shock that may be caused if your body
becomes a path which electricity travels to reach ground.
When protected by a GFCI, one may still feel a shock, but
the GFCI is intended to cut current off quickly enough so
that a person in normal health should not suffer any serious
electrical injury.
WARNING! Generator voltage could cause
electrical shock or burn resulting in death or
serious injury. Contact with the hot and neutral
conductor at the same time could cause electrical shock
or burn, even if the circuit is GFCI protected.
Testing the GFCI
With the engine running, test your GFCI outlet prior to each
use, as follows:
Push the “Test” button. The “Reset” button should pop
out, which should allow no power to reach the outlet.
Press the “Reset” button firmly until it is fully in place
and locks in that position. If the GFCI outlet does not
reset properly, do not use the outlet. Call or take your
generator to a local service center.
If the GFCI trips by itself at any time, reset and test the
outlet.
120/240 Volt AC, 20 Amp, Locking Receptacle
Use a NEMA L14-20 plug with this receptacle. Connect
a 4_wire cord set rated for 250 Volt AC loads at 20 Amps.
The generator’s locking receptacle is not protected by a
GFCI.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 3,500 watts of power (3.5 kW)
at 14.6 Amps for 240 Volts or two independent 120 Volt
loads at 14.6 Amps each.
4-Wire Cord Set
240V
120V
120V
W (Neutral)
X (Hot)
Y (Hot)
NEMA L14-20
Ground (Green)
Not for
Reproduction
11
Operation
Generator Capacity
To make sure your generator can supply enough running
watts and starting watts for the items you will power at the
same time, follow these three simple steps:
1. Select the items you will power at the same time. See
following list for typical wattages.
* Typical wattages listed are approximate only. Check tool
or appliance for actual wattage.
** The momentary electrical current the generator can
provide to start electric motors, per Briggs & Stratton
standard 628K. It does not represent the power required to
continuously run electrical loads. It is the maximum current
that can momentarily be supplied when starting a motor,
multiplied by the generator’s rated voltage.
2. Total the running watts. This is the amount of power
your generator must produce to keep your items
running. See following example:
Example
Total running watts = 2125
Highest starting watts = 2100
Total generator watts required = 4225
3. Estimate the starting watts you will need. Because not
all motors start at the same time, total starting wattage
can be estimated by adding only the item with the
highest additional starting watts requirements to the
total running watts from step 2.
Power Management
To manage generator power, sequentially add loads as
follows:
1. With nothing connected to generator, start the engine
outdoors.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Never add more loads than the generator capacity. Take
special care to consider starting watts in generator capacity.
CO Guard
Carbon Monoxide (CO) Shutdown System
CO Guard automatically shuts down the engine when
harmful levels of carbon monoxide accumulate around the
generator or a CO Guard fault occurs. After shutdown, the
CO Guard indicator light will blink for at least five minutes
per the chart below.
CO Guard DOES NOT replace carbon monoxide alarms.
Install battery-powered carbon monoxide alarm(s) in your
home. Don’t run generator in enclosed areas.
Color/Pattern Description
Red
• •
Carbon monoxide accumulated around
generator. Move generator to an
open, outdoor area 20 ft. (6.1 m) from
occupied spaces with exhaust pointed
away. Automatic shutoff is an indication
generator was improperly located.
If you start to feel sick, dizzy, weak, or
your homes carbon monoxide alarm
sounds while using this product, get
to fresh air right away. Call emergency
services. You may have carbon
monoxide poisoning.
Blue
• • •
CO Guard fault occured*.
See Briggs & Stratton authorized service
dealer.
*Blue light will blink for five seconds at the startup of generator to
show CO Guard functioning properly.
Step 5: Generator Shutdown
1. Turn off and unplug all electrical loads from generator
panel receptacles. Never stop engine with electrical
devices plugged in and turned on.
2. Let engine run at no-load for one minute to stabilize
internal temperatures of engine and generator.
3. Push engine switch to off (0) position.
4. Move fuel valve to off (0) position.
Tool or Appliance Running Watts Starting Watts
Window AC - 10000 BTU
1000 2100
Refrigerator/Freezer 550 1350
Plasma Television 500
Light (75 Watts) 75
2125 Total
Running Watts
2100 Highest
Starting Watts
Tool or Appliance
Running
Watts*
Starting
Watts**
Light Bulb - 75 Watt 75 -
Sump Pump - 1/3 HP 1140 2850
Refrigerator/Freezer 550 1350
Water Well Pump - 1/3 HP 575 1440
Window AC - 10,000 BTU 1000 2100
Furnace Fan Blower - 1/2 HP 800 2350
Microwave Oven - 1000 Watt 1000 -
Plasma Television - 50” 500 -
Laptop 250 -
Garage Door Opener - 1/2 HP 300 500
Not for
Reproduction
12 BRIGGSandSTRATTON.COM
Maintenance
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in
adverse conditions noted below.
1
Service more often under dirty or dusty conditions.
2
See any authorized dealer for service.
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized dealer
for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To receive
full value from the warranty, the operator must maintain the
generator as instructed in this manual.
All service and adjustments should be made at least once
each season. A new spark plug and clean air filter assure
proper fuel-air mixture and help your engine run better and
last longer. Follow requirements in Maintenance Schedule.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual.
However, to obtain ”no charge” emissions control service,
the work must be performed by a factory authorized dealer.
See Emissions Warranty.
Cleaning
Daily or before use, look around and underneath
the generator for signs of oil or fuel leaks. Clean any
accumulated debris. Keep area around muffler free from
any debris.
Use a soft bristle brush to loosen caked on dirt or oil.
Use a damp cloth to wipe exterior surfaces clean.
NOTICE Improper treatment of generator could damage
it and shorten its life. Do not expose generator to excessive
moisture, dust, dirt, or corrosive vapors. Do not insert any
objects through cooling slots.
Fuel Valve Maintenance
The fuel valve is equipped with a fuel sediment cup,
screen, and o-ring that need to be cleaned.
1. Move fuel valve to off (0) position.
2. Remove sediment cup from fuel valve. Remove o-ring
and screen from fuel valve.
3. Wash sediment cup, o-ring, and screen in a
nonflammable solvent. Dry them thoroughly.
4. Place screen and o-ring into fuel valve. Install
sediment cup and tighten securely.
5. Move fuel valve to on (I) position, and check for leaks.
Replace fuel valve if there is any leakage.
Screen
O-Ring
Sediment Cup
First 5 Hours
Change engine oil
Every 8 Hours or Daily
Clean debris
Check engine oil level
Every 25 Hours or Yearly
Clean engine air filter
1
Every 50 Hours or Yearly
Change engine oil
1
Yearly
Replace engine air filter
1
Service fuel valve
Service spark plug
Inspect muffler and spark arrester
Clean cooling system
1, 2
Not for
Reproduction
13
Maintenance
Engine Maintenance
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF or
higher. Do not use special additives. See Common Service
Parts.
Outdoor temperatures determine the proper oil viscosity for
the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.
* Below 4°C (40°F) the use of SAE 30 will result in hard starting.
** Above 27°C (80°F) the use of 10W30 may cause increased oil
consumption. Check oil level more frequently.
Checking/Adding Engine Oil
Oil level should be checked prior to each use or at least
every 8 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Clean area around oil fill, remove dipsitck and wipe
with clean cloth. Replace dipstick. Remove and check
oil level.
NOTICE Do not screw in dipstick when checking oil level.
3. Verify oil is at full mark on dipstick.
4. If needed, slowly pour oil into oil fill opening to the
point of overflowing.
5. Replace and tighten dipstick.
NOTICE Do not attempt to crank or start engine before
it has been properly serviced with recommended oil. This
could result in an engine failure.
CAUTION Avoid prolonged or repeated skin contact with
used motor oil. Used motor oil has been shown to cause
skin cancer in certain laboratory animals. Thoroughly wash
exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON’T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Changing Engine Oil
If you are using your generator under extremely dirty or
dusty conditions, or in extremely hot weather, change the
oil more often.
Change the oil while the engine is still warm from running,
as follows:
1. Make sure unit is on a level surface.
2. Remove oil drain plug and drain oil completely into a
suitable container.
3. Reinstall oil drain plug and tighten securely. Remove
dipstick.
4. Slowly pour recommended oil (about 20 oz. (0.6 l)) into
oil fill opening. Pause to permit oil to settle. Fill to Full
mark on dipstick.
5. Wipe dipstick clean each time oil level is checked. Do
not overfill.
6. Reinstall dipstick. Tighten cap securely.
7. Wipe up any spilled oil.
Service Air Cleaner
WARNING! Fuel and its vapors are extremely
flammable which could cause burns or fire
resulting in death or serious injury.
• Do not start and run engine with air filter removed.
Your engine will not run properly and may be damaged if
you run it with a dirty air cleaner. Clean or replace more
often if operating under dusty or dirty conditions.
NOTICE Do not use pressurized air to clean the filter.
Pressurized air can damage the filter.
Oil Drain Plug
Not for
Reproduction
14 BRIGGSandSTRATTON.COM
Maintenance
To service the air cleaner, follow these steps:
1. Unclamp latches that hold on the cover.
2. Remove cover and foam air filter.
3. Wash the foam air filter in liquid detergent and water.
Squeeze dry the foam air filter in a clean cloth.
NOTICE If the filter is excessively dirty, replace with a new
filter. See Common Service Parts.
4. Saturate the foam air filter with clean engine oil. To
remove the excess engine oil, squeeze the foam air
filter in a clean cloth.
5. Reinstall clean or new foam air filter.
6. Reinstall the air filter cover and re-clamp latches.
Service Spark Plug
Changing the spark plug will help your engine to start
easier and run better.
1. Clean area around spark plug.
2. Remove and inspect spark plug.
3. Replace spark plug if electrodes are pitted, burned
or porcelain is cracked. Use the recommended
replacement spark plug. See Common Service Parts.
4. Check electrode gap with wire feeler gauge and reset
spark plug gap to recommended gap if necessary
(see Specifications).
5. Install spark plug and tighten firmly.
Inspect Muffler and Spark Arrester
The engine exhaust muffler has a spark arrester screen.
Inspect the muffler for cracks, corrosion, or other damage.
Inspect spark arrester screen for damage or carbon
blockage. Clean if carbon blockage is found using brush
and commercial solvent or replace if damaged.
WARNING!
Contact with muffler area could
cause burns resulting in serious injury.
• Allow equipment to cool before servicing.
It is a violation of California Public Resource Code, Section
4442, to use or operate the engine on any forest-covered,
brush-covered, or grass-covered land unless the exhaust
system is equipped with a spark arrester, as defined
in Section 4442, maintained in effective working order.
Other states or federal jurisdictions may have similar laws,
reference Federal Regulation 36 CFR Part 261.52.
Replace spark arrester as follows:
1. Remove four screws that connect heat shield to
muffler.
2. Remove four screws that attach spark arrester screen.
3. Obtain a replacement screen.
4. Reattach screen and muffler guard.
Common Service Parts
Air Cleaner .............................594234
Spark Plug .............................798615
Engine Oil Bottle ........................100028
Synthetic Oil Bottle ......................100074
Contact an authorized service dealer or
BRIGGSandSTRATTON.com for a full list of parts and
diagrams.
Muffler
Spark Arrester Screen
Screws
Screws
Heatshield
Latches
Filter
Cover
Not for
Reproduction
15
Storage
Storage
If storing the unit for more than 30 days, use the following
guidelines to prepare it for storage.
Long Term Storage Instructions
1. Clean the generator as outlined in Cleaning.
2. Change engine oil while engine is still warm, drain oil
from crankcase. Refill with recommended grade. See
Changing Engine Oil.
3. Treat or drain fuel from generator as fuel can become
stale when stored over 30 days.
Stale fuel causes acid and gum deposits to form in the fuel
system or on essential carburetor parts. To keep fuel fresh,
use a fuel stabilizer.
There is no need to drain gasoline from the engine if a
fuel stabilizer is added according to instructions. Run the
engine for 2 minutes to circulate the stabilizer throughout
the fuel system before storage.
If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container.
Then run the engine until it stops from lack of fuel. The use
of a fuel stabilizer in the storage container is recommended
to maintain freshness.
WARNING!
Fuel and its vapors are extremely
flammable and explosive which could cause
burns, fire or explosion resulting in death or
serious injury.
• When storing fuel or equipment with fuel in tank, store
away from furnaces, stoves, water heaters, clothes dryers
or other appliances that have pilot light or other ignition
source because they could ignite fuel vapors.
• When draining fuel, turn generator engine off and let it
cool at least 2 minutes before removing fuel cap. Loosen
cap slowly to relieve pressure in tank. Drain fuel tank
outdoors. Keep fuel away from sparks, open flames, pilot
lights, heat, and other ignition sources.
• Check fuel lines, tank, cap and fittings frequently for
cracks or leaks. Replace if necessary.
4. Store generator in clean, dry area and cover with a
suitable protective cover that does not retain moisture.
WARNING! Storage covers could cause a fire
resulting in death or serious injury.
• Do not place a storage cover over a hot or running
generator. Let equipment cool for a sufficient time before
placing the cover on the equipment.
IC Compliance Statement
IC Information to User
This device complies with Industry Canada’s licence-
exempt RSSs. Operation is subject to the following two
conditions:
(1) This device may not cause interference; and
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.
Not for
Reproduction
16 BRIGGSandSTRATTON.COM
Troubleshooting/Specifications
Problem Cause Correction
Engine is running, but no AC
output is available.
1. One of the circuit breakers is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. GFCI tripped.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
4. Reset GFCI.
Engine runs well at no-load but
“bogs down” when loads are
connected.
1. Generator is overloaded. 1. See Generator Capacity.
Engine will not start; starts and
runs rough or shuts down when
running.
1. Engine switch set to off (0) position.
2. Fuel valve is in off (0) position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of fuel.
6. Spark plug wire not connected to
spark plug.
7. Flooded with fuel.
1. Set switch to on (I) position.
2. Turn fuel valve to on (I) position.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank.
6. Connect wire to spark plug.
7. Wait 5 minutes and re-crank engine.
Engine shuts down and CO
Guard LED blinks red (• ).
1. Generator improperly located.
1. Move generator to an open, outdoor
area. See CO Guard Carbon
Monoxide (CO) Shutdown System.
For all other issues, see a Briggs & Stratton authorized dealer.
Power Ratings: The gross power rating for individual gasoline engine models is labeled in accordance with SAE (Society of Automotive
Engineers) code J1940 Small Engine Power & Torque Rating Procedure, and is rated in accordance with SAE J1995. Torque values are
derived at 2600 RPM for those engines with “rpm” called out on the label and 3060 RPM for all others; horsepower values are derived at
3600 RPM. The gross power curves can be viewed at www.BRIGGSandSTRATTON.COM. Net power values are taken with exhaust and
air cleaner installed whereas gross power values are collected without these attachments. Actual gross engine power will be higher than
net engine power and is affected by, among other things, ambient operating conditions and engine-to-engine variability. Given the wide
array of products on which engines are placed, the gasoline engine may not develop the rated gross power when used in a given piece of
power equipment. This difference is due to a variety of factors including, but not limited to, the variety of engine components (air cleaner,
exhaust, charging, cooling, carburetor, fuel pump, etc.), application limitations, ambient operating conditions (temperature, humidity,
altitude), and engine-to engine variability. Due to manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of
higher rated power for this engine.
* Generator certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14, Motors and Generators and
PGMA (Portable Generator Manufacturers’ Association) standard ANSI/PGMA G300-2018, Safety and Performance of Portable Generators
**Per Briggs & Stratton 628K.
Specifications
Rated Wattage* ........................................... 3,500
Starting Wattage** .........................................4,375
AC Current at 120 Volts .................................29.1 Amps
AC Current at 240 Volts .................................14.6 Amps
Frequency ..................................... 60 Hz at 3600 rpm
Phase .............................................Single Phase
Displacement ................................ 12.69 cu. in. (208 cc)
Spark Plug Gap ................................0.030 in. (0.76 mm)
Fuel Capacity ........................... 5 U.S. Gallons (18.9 Liters)
Oil Capacity ................................20 Ounces (0.6 Liters)
Not for
Reproduction
17
Troubleshooting
Schematic
Not for
Reproduction
18 BRIGGSandSTRATTON.COM
Warranty
80011053_EN Rev. A
BRIGGS & STRATTON PRODUCTS WARRANTY POLICY
LIMITED WARRANTY
Briggs & Stratton warrants that, during the warranty period specified below, it will repair or replace, free of charge, any part that is defective in material or workmanship
or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This warranty is effective for
and is subject to the time periods and conditions stated below. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at
BRIGGSandSTATTON.COM. The purchaser must contact the Authorized Service Dealer, and then make the product available to the Authorized Service Dealer for
inspection and testing.
There is no other express warranty. Implied warranties, including those of merchantability and fitness for a particular purpose, are limited to the
warranty period listed below, or to the extent permitted by law. Liability for incidental or consequential damages are excluded to the extent exclusion is
permitted by law. Some states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and you may
also have other rights which vary from state to state or country to country.**
WARRANTY PERIOD
After 12 months, warranty covers parts only.
* Applies to Briggs & Stratton engines only. Warranty coverage of non-Briggs & Stratton engines is provided by that engine manufacturer. Emissions-related components
are covered by the Emissions Warranty Statement.
** In Australia - Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major
failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be
of acceptable quality and the failure does not amount to a major failure. For warranty service, find the nearest Authorized Service Dealer in our dealer locator map at
BRIGGSandSTRATTON.COM, or by calling 1300 274 447, or by emailing or writing to [email protected], Briggs & Stratton Australia Pty Ltd, 1
Moorebank Avenue, NSW, Australia, 2170.
The warranty period begins on the date of purchase by the first retail or commercial consumer. “Consumer use” means personal residential household use by a retail
consumer. “Commercial use” means all other uses, including use for commercial, income producing or rental purposes. Once a product has experienced commercial use,
it shall thereafter be considered as a commercial use product for purposes of this warranty.
Save your proof of purchase receipt. If you do not provide proof of the initial purchase date at the time warranty service is requested, the manufacturing date of the
product will be used to determine the warranty period. Product registration is not required to obtain warranty service on Briggs & Stratton products.
ABOUT YOUR WARRANTY
Warranty service is available only through Briggs & Stratton Authorized Service Dealers. This warranty covers only defects in materials or workmanship. It does not cover
damage caused by improper use or abuse, improper maintenance or repair, normal wear and tear, or stale or unapproved fuel.
Improper Use and Abuse - The proper, intended use of this product is described in the Operator’s Manual. Using the product in a way not described in the Operator’s
Manual or using the product after it has been damaged will not be covered under this warranty. Warranty coverage will also not be provided if the serial number on the
product has been removed or the product has been altered or modified in any way, or if the product has evidence of abuse such as impact damage or water/chemical
corrosion damage.
Improper Maintenance or Repair - This product must be maintained according to the procedures and schedules provided in the Operator’s Manual, and serviced or
repaired using genuine Briggs & Stratton parts or equivalent. Damage caused by lack of maintenance or use of non-original parts is not covered by warranty.
Normal Wear and Tear - Like most mechanical devices, your unit is subject to wear even when properly maintained. This warranty does not cover repairs when normal
use has exhausted the life of a part or the equipment. Maintenance and wear items such as filters, belts, cutting blades, and brake pads (except engine brake pads) are
not covered by warranty due to wear characteristics alone, unless the cause is due to defects in material or workmanship.
Stale or Unapproved Fuel - In order to function correctly, this product requires fresh fuel that conforms to the criteria specified in the Operator’s Manual. Engine or
equipment damage caused by stale fuel or the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty.
Other Exclusions - This warranty excludes damage due to accident, abuse, modifications, alterations, improper servicing, freezing or chemical deterioration.
Attachments or accessories that were not originally packaged with the product are also excluded. There is no warranty coverage on equipment used for primary power in
place of utility power or on equipment used in life support applications. This warranty does not include used, reconditioned, second-hand, or demonstration equipment or
engines. This warranty also excludes failures due to acts of God and other force majeure events beyond the manufacturer’s control.
Item Consumer Use Commercial Use
Equipment 24 months 12 months
Engine* 24 months 12 months
Battery (if equipped) 3 months None
Not for
Reproduction
Groupe électrogène mobile
extérieur
Manuel d’utilisation
Référence du modèle ________________________
Révision __________________________________
Numéro de série ____________________________
Date d’achat : ______________________________
Copyright © 2019. Briggs & Stratton Corporation
Milwaukee, WI, États-Unis. Tous droits réservés.
BRIGGSandSTRATTON.COM
Not for
Reproduction
FR2 BRIGGSandSTRATTON.COMFR2 BRIGGSandSTRATTON.COM
Description de l’équipement
Table des matières
Description de l’équipement ....................2
Fonctions et commandes.......................5
Utilisation....................................7
Entretien ...................................13
Entreposage ................................16
Déclaration de conformité IC
....................16
Dépannage / Spécifications....................17
Garantie....................................18
Enregistrer votre produit
Pour assurer une couverture rapide et complète de la
garantie, veuillez enregistrer votre produit en ligne à
l’adresse onlineproductregistration.com
Symboles et significations
Signal Signification
DANGER
Indique un risque qui, s’il n’est pas évité,
causera la mort ou des blessures graves.
AVERTISSEMENT
Indique un danger lequel, si non évité, peut
entraîner la mort ou des blessures graves.
ATTENTION
Indique un risque qui, s’il n’est pas
évité, pourrait causer des blessures
mineures ou modérées.
AVIS
Indique de l’information considérée
comme importante mais n’impliquant
aucun danger particulier.
Symbole Nom Explication
Symbole
d’alerte de
sécurité
Indique un risque de blessure
corporelle possible.
Manuel
d’utilisation
Ne pas respecter les
avertissements, les instructions et le
manuel de l’utilisateur peut entraîner
des blessures graves ou la mort.
Vapeurs
toxiques
L'échappement moteur contient
du monoxyde de carbone, un
gaz toxique qui peut vous tuer en
quelques minutes. Il est incolore
et inodore.
Incendie
Le gaz propane et le gaz naturel
sont extrêmement inflammables
et explosifs et pourraient causer
des brûlures ou un incendie
susceptibles d’entraîner des
blessures graves, voire la mort.
L’échappement du moteur peut
entraîner un incendie, ce qui peut
provoquer des blessures graves,
voire la mort.
Symbole Nom Explication
Électrocution
La génératrice peut provoquer une
électrocution entraînant la mort ou
de graves lésions.
Surface
chaude
Le silencieux peut causer des
brûlures risquant de provoquer
des blessures graves.
AVERTISSEMENT
!
Ce produit peut vous exposer
à des agents chimiques, y compris les
échappements des moteurs à essence, connus
dans l’État de la Californie pour causer le cancer, ainsi que le
monoxyde de carbone, connu dans l’État de la Californie
pour causer des malformations congénitales ou les
dommages à l’appareil reproducteur. Pour obtenir de plus
amples renseignements, visitez le www.P65Warnings.ca.gov.
Description de l’équipement
Lisez bien ce manuel afin de vous familiariser
avec votre génératrice. Prenez connaissance de
ses applications, ses limitations, et tous les
risques impliqués. Sauvegardez ces instructions
originales aux fins de consultation future.
La génératrice extérieure est une génératrice à courant
altern
atif (C.A.) à champ tournant entraîné par moteur
équipé d’un régulateur de tension. La génératrice a été
conçue pour alimenter les circuits d’éclairage compatibles,
les appareils électroménagers, les outils et les moteurs.
Le régulateur de tension est conçu pour maintenir
automatiquement le niveau de tension de sortie.
La génératrice portative produit de l’énergie qui peut être
utilisée pour les articles extérieurs en utilisant les rallonges
électriques ou pour un premier rétablissement temporaire du
courant à la maison. Avant votre prochaine panne de courant
à la maison, installez un commutateur de transfert homologué.
Un commutateur de transfert est un appareil séparé installé
par un électricien agréé qui permet à la génératrice portative
d’être dotée d’un cordon électrique en utilisant la prise
verrouillable directement dans le système électrique de votre
domicile. Les rallonges électriques connectées au panneau de
contrôle de la génératrice portative ne sont pas destinées à
être une solution à long terme lorsqu’elles sont connectées à
des articles se trouvant à l’intérieur de votre maison.
Nous nous sommes efforcés de fournir dans ce document
des informations exactes et à jour. Toutefois, le fabricant se
réserve le droit de modifier, changer ou améliorer de toute
autre façon la génératrice et cette documentation en tout
temps, et ce, sans préavis.
AVIS Si vous avez des questions sur l’usage prévu, prenez
contact avec le service de réparation agréé. Cet équipement
est conçu pour être utilisé avec les pièces Briggs & Stratton
approuvées uniquement.
Ce dispositif d’allumage par étincelle est conforme à la
norme canadienne CAN ICES-2/NMB-2.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Simplicity 030747-00 Manuel utilisateur

Catégorie
Groupes électrogènes
Taper
Manuel utilisateur

dans d''autres langues