3 FF-400-13
Speaking Diaphragm
Assembly
Replacement Instructions for
FF-400-13 Speaking Diaphragm
Assembly.
Important: Keep these Replacement
Instructions for reference.
Membrane phonique
Directives de remplacement de la
membrane phonique FF-400-13.
Important : Conserver ces directives
de remplacement à titre de référence.
98-0060-0142-8/2
34-8704-5487-2
The 3M™ Speaking Diaphragm Assembly
FF-400-13 is replaced by following these steps:
1. Remove the nose cup assembly by grasping
the nose cup below the inhalation valve
and gently pulling up and away from lens
assembly (Fig. 1).
2. Remove valve cover by depressing bottom
of cover with thumb and sliding cover up,
parallel with lens (Fig. 2).
3. Remove exhalation valve assembly by
turning counter clockwise ¼ turn (Fig. 3).
4. Remove speaking diaphragm assembly by
turning counter clockwise ¼ turn (Fig 4).
5. Align speaking diaphragm lugs with
speaking diaphragm opening in lens
assembly.
Voici les étapes à suivre pour remplacer la
membrane phonique FF-400-13 3M™.
1. Retirer l’ensemble coquille nasale en tenant
la coquille juste au-dessous de la soupape
d’inhalation et l’éloigner doucement de
l’ensemble lentille en tirant vers le haut
(Fig. 1).
2. Enlever le couvercle de la soupape en
appuyant sur le bas du couvercle avec le
pouce et en faisant glisser le couvercle vers
le haut, parallèlement à la lentille (Fig. 2).
3. Retirer l’ensemble soupape d’exhalation
en le tournant de un quart de tour dans le
sens contraire des aiguilles d’une montre
(Fig. 3).
4. Enlever la membrane phonique en la
tournant de un quart de tour dans le
sens contraire des aiguilles d’une montre
(Fig. 4).
Fig. 2Fig. 1 Fig. 3
Fig. 4
Fig. 5
6. Turn clockwise ¼ turn until firm stop.
7. Replace exhalation valve assembly.
8. Replace valve cover assembly.
9. Replace nose cup assembly (Fig. 5).
FOR MORE INFORMATION
In United States, contact:
Website: www.3M.com/OccSafety
Technical Assistance: 1-800-243-4630
For other 3M products:
1-800-3M-HELPS or 1-651-737-6501
5. Aligner les tiges de la membrane phonique
avec les orifices prévus pour ces dernières
dans l’ensemble lentille.
6. Tourner de un quart de tour dans le sens
des aiguilles d’une montre, jusqu’à l’arrêt
complet.
7. Remettre la soupape d’exhalation en place.
8. Remettre le couvercle de la soupape en
place.
9. Remettre la coquille nasale en place (Fig. 5).
POUR OBTENIR DE PLUS AMPLES
RENSEIGNEMENTS/FOR MORE
INFORMATION
Au Canada, communiquer avec/In Canada,
contact :
Internet : www.3M.com/CA/occsafety
Assistance technique/Technical Assistance :
1 800 267-4414
Pour les autres produits 3M/For other
3M products : 1 800 364-3577
3M Occupational Health and Environmental
Safety Division
3M Center, Building 0235-02-W-70
St. Paul, MN 55144-1000
Printed in U.S.A.
3M is a trademark of 3M Company.
© 2010 3M Company. All rights reserved.
3M Occupational Health
and Environmental Safety Division
3M Canada Company
P.O. Box 5757 London,
Ontario N6A 4T1
Printed in U.S.A.
3M is a trademark of 3M Company.
© 2010 3M Company. All rights reserved
Division des produits d’hygiène
industrielle et de sécurité
environnementale de 3M
Compagnie 3M Canada
C.P. 5757
London (Ontario) N6A 4T1
Imprimé aux É.-U.
3M est une marque de commerce de la Compagnie
3M.
© 3M, 2010. Tous droits réservés.
  • Page 1 1
  • Page 2 2