United States Stove Company VG2020-P Le manuel du propriétaire

Catégorie
Poêle à bois
Taper
Le manuel du propriétaire
853527D-1004J
MODEL: VG2020
United States Stove Company
227
Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
U.S. Environmental Protection Agency
Certied to comply with 2020
particulate emissions standards.
R
Report Number: F19-476
Save These Instructions. This manual will help you to obtain efcient,
dependable service from the heater, and enable you to order repair
parts correctly. Keep in a safe place for future reference.
This manual is subject to change without notice.
ALL PICTURES SHOWN ARE FOR ILLUSTRATIVE PURPOSES ONLY.
ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENT.
SAFETY NOTICE: If this heater is not properly installed, a house re
may result. For your safety, follow the installation instructions. Never
use make-shift compromises during the installation of this heater.
Contact local building or re ofcials about permits, restrictions
and installation requirements in your area.
CAUTION! Please read this entire manual before you install or
use your new room heater. Failure to follow instructions may
result in property damage, bodily injury, or even death. Improper
Installation Could Void Your Warranty!
Tested Per EPA Methods ALT-125, ASTM
E2515, ASTM E3053 and CSA B415
Certied to UL 1482-2011 (R2015) and
ULC-S627-00 (R2016)
Mobile home approved (U.S. ONLY)
-2-
Optional Accessories
Outside Air Intake Kit 4FAK
The instructions pertaining to the installation of your wood stove comply with UL-1482 (R2015) and ULC-S627
standards. This manual describes the installation and operation of the Vogelzang, VG2020 wood heater. This
heater meets the 2020 U.S. Environmental Protection Agency’s cordwood emission limits for wood heaters sold
after May 15, 2020. Under specic test conditions this heater has been shown to deliver heat at rates ranging from
15,261 to 63,196 Btu/hr with 1 g/hr and 70% efciency. Note: The BTU ratings mentioned above are based on the
EPA test protocol under specic test conditions. Our advertised BTU’s are based on the rst hour of operation at
high burn rate burning cordwood.
CAUTIONS:
HOT WHILE IN OPERATION. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS.
DO NOT USE CHEMICALS OR FLUIDS TO IGNITE THE FIRE.
DO NOT LEAVE THE STOVE UNATTENDED WHEN THE DOOR IS SLIGHTLY OPENED.
DO NOT BURN GARBAGE, FLAMMABLE FLUID SUCH AS GASOLINE, NAPHTHA OR MOTOR OIL.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
ALWAYS CLOSE THE DOOR AFTER THE IGNITION.
Combustible: Wood
Colors: Metallic Black
Flue Pipe Diameter: 6” (152.5 mm)
Flue Pipe Type:
(Standard Single Wall or Double Wall):
Black or Blued Steel 2100°F (650°C)
Minimum Chimney Height: 12’ (3.7 m)
Maximum Log Length: 21” (533.5 mm)
Dimensions
MODEL DEPTH WIDTH HEIGHT
Overall: Depth x Width x Height:
VG2020-L 20.5” (521 mm) 27” (686 mm) 31.3” (796 mm)
VG2020-P 21” (534 mm) 27” (686 mm) 31.6” (803 mm)
Combustion Chamber: Width x Depth: 22-3/4” X 11.78” (578 mm X 300 mm)
Volume: Cubic Feet: 1.6 cubic feet
Door Opening: Width x Height: 18” X 9.75” (458 mm X 248 mm)
Pyroceramic Glass Door: (Viewing) Width x Height: 16” X 10.26” (407 mm X 261 mm)
Note: Register your product on line at www.usstove.com. Save your receipt with your records for any claims.
-3-
BLOWER ASSEMBLY
The blower assembly must be disconnected from the
source of electrical supply before attempting the
installation. The blower assembly is intended for use only
with a stove that is marked to indicate such use. Do
not route the supply cord near or across hot surfaces!
Fix the assembly to the back of the stove with the four
screws provided.
ASH PAN ASSEMBLY
Remove ash pan from rebox. Under the rebox, there
are two brackets; Slide the ash pan into these brackets.
FLUE COLLAR ASSEMBLY
Mount the ue collar to the top of the unit as shown
using the (3) 5/16-18 x 1-1/2 bolts, (3) washers, and (3)
weld tabs provided in the parts box.
FIREBRICK CONFIGURATION
Replace the Firebrick as shown in the illustration.
5/16-18 x 1-1/2
BOLT
WASHER
HEATER
TOP
GASKET
WELD
TAB
TOOLS AND MATERIALS NEEDED FOR INSTALLATION
You will need a drill with a 1/8” bit to install sheet metal screws into connector pipe. A 5/16” socket/wrench or
screw driver to install the room air deector, and blower assembly described in this manual. A 1/2” socket/wrench
to install the ue collar. A non-combustible oor protector as specied in this manual. All chimney and chimney
connector components required for your particular chimney installation.
Assembly Instructions
AIR DEFLECTOR ASSEMBLY
Use the provided screws to attach the air deector to
the rear of the unit.
-4-
Installation
SAFETY NOTICE
IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW
THE INSTALLATION INSTRUCTIONS.
CONSULT YOUR MUNICIPAL BUILDING DEPARTMENT OR FIRE OFFICIALS ABOUT PERMITS, RESTRICTIONS AND
INSTALLATIONS REQUIREMENTS IN YOUR AREA.
USE SMOKE DETECTORS IN THE ROOM WHERE YOUR STOVE IS INSTALLED.
KEEP FURNITURE AND DRAPES WELL AWAY FROM THE STOVE.
NEVER USE GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR SIMILAR
LIQUIDS TO START OR “FRESHEN UP” A FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE
HEATER WHILE IT IS IN USE.
IN THE EVENT OF A CHIMNEY FIRE, PUSH THE AIR CONTROL FULL CLOSED TO DEPRIVE THE FIRE OF OXYGEN.
CALL THE FIRE DEPARTMENT.
DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM.
A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED.
POSITIONING THE STOVE
It is very important to position the wood stove as close as possible to the chimney, and in an area that will favor
the most efcient heat distribution possible throughout the house. The stove must therefore be installed in the
room where the most time is spent, and in the most spacious room possible. Recall that wood stoves produce
radiating heat, the heat we feel when we are close to a wood stove. A wood stove also functions by convection,
that is through the displacement of hot air accelerated upwards and its replacement with cooler air. If necessary,
the hot air distribution from the stove may be facilitated by the installation of a blower. The wood stove must not
be hooked up to a hot air distribution system since an excessive accumulation of heat may occur. A wood stove
must never be installed in a hallway or near a staircase, since it may block the way in case of re or fail to respect
required clearances.
FLOOR PROTECTOR
This heater must have a non-combustible oor protector with an R-Value
of at least 1.4 installed beneath it if the oor is constructed of combustible
material. If a oor pad is used, it should be UL listed or equal. The oor
protector should be large enough to extend under the stove and beyond
each side as indicated. If there is a horizontal run of ue pipe, there needs
to be oor protection under it that extends two inches beyond either side
of the pipe.
The oor protector should exceed the stove as follows:
REAR
FRONT
SIDE SIDE
Front Sides Rear
22”
(559 mm)
8”
(204 mm)
2”
(51 mm)
- Canadian Installations require 8”
(204 mm) to the rear.
-5-
CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during installation
of the stove.
If there is a horizontal run of ue pipe there must be at lease 18” of clearance between the pipe and the
ceiling. There also has to be oor protection under the horizontal run that extends 2” beyond each side of the
ue pipe.
Floor to ceiling height must be at least 7’ (2.13 m) in all cases.
Do not place any combustible material within 4’ (1.2 m) of the front of the unit.
The clearance between the ue pipe and a wall are valid only for vertical walls and for vertical ue pipe.
The chimney connector must not pass through an attic or roof space, closet or similar concealed space, a
oor, or a ceiling.
For Canadian installations, where passage through a wall, or partition of combustible construction is desired,
the installation must conform to CAN/CSA-B365.
A ue pipe crossing a combustible wall must have a minimum clearance of 18” (457.2 mm).
To reduce ue clearances from combustible materials, contact your local safety department.
Single Wall Pipe
(Double Wall Pipe)
Key in mm
A 15 (12) 381 (305)
B 18 (18) 458 (458)
C 19 (16) 483 (407)
D 29 (29) 737 (737)
E 12 (12) 305 (305)
F 22 (22) 559 (559)
D
B
A
C
E
F
E
D
B
A
C
E
F
E
Slide the hose clamp over the aluminium ex pipe. Then slide the ex pipe over the air intake tube of the stove.
Next tighten the hose clamp over the end of the aluminium ex hose.
OUTSIDE COMBUSTION AIR
Your wood stove is approved to be installed with an outside air intake (4FAK) which
is necessary for a mobile home. This type of installation is also required in air tight
houses and houses with negative pressure problems. You can purchase this option
through your heater dealer. Make sure to specify the part number mentioned in
this booklet. Installation instructions are supplied with the air intake kit.
Outside combustion air may be required if:
1. Your stove does not draw steadily, smoke roll-out occurs, wood burns poorly, or
back-drafts occur whether or not there is combustion present.
2. Existing fuel-red equipment in the house, such as replaces or other heating
appliances, smell, do not operate properly, suffer smoke roll-out when opened,
or back-drafts occur whether or not there is combustion present.
3. Opening a window slightly on a calm (windless) day alleviates any of the above symptoms.
4. The house is equipped with a well-sealed vapor barrier and tight tting windows and/or has any powered
devices that exhaust house air.
5. There is excessive condensation on windows in the winter.
6. A ventilation system is installed in the house.
“Dryer Venting Kit”
-6-
For use in MOBILE HOMES (U.S. installations ONLY):
WARNING! DO NOT INSTALL IN SLEEPING ROOM.
CAUTION! THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL, AND CEILING/ROOF MUST BE
MAINTAINED.
INSTALL IN ACCORDANCE WITH 24 CFR, PART 3280 (HUD).
USE A FACTORY BUILT CHIMNEY THAT COMPLIES WITH UL 103 STAN
DARDS; THEREFORE IT MUST BE A TYPE HT
(2100°F).
USE A SPARK ARRESTER.
THE STOVE MUST BE ATTACHED TO THE STRUCTURE OF THE MOBILE HOME.
SECURING APPLIANCE’S ON A PEDESTAL TO THE FLOOR
Use the designated holes to secure the unit to the oor.
SECURING APPLIANCE’S WITH LEGS TO THE FLOOR
1. The bracket engages around the square extrusion of the leveling bolt inserted into the leg.
2. Once appliance is leveled, position the bracket and attach to the oor using the appropriate hardware
needed for your specic ooring.
3. Install one bracket per leg or consult your local authority having jurisdiction to determine how many points of
attachment are required.
-7-
CHIMNEY CONNECTOR (STOVE PIPE)
The chimney connector and chimney must have the same
diameter as the stove outlet (6”). If this is not the case, we
recommend you contact your dealer to ensure there will be
no problem with the draft. The stovepipe must be made of
aluminized or cold roll steel and have a minimum thickness of
0.021” or 0.53mm. It is strictly forbidden to use galvanized steel.
The smoke pipe should be assembled to promote the male
section (crimped end) of the pipe to be faced down. Attach
each section to another with three equidistant metal screws.
The pipe must be short and straight. All sections installed
horizontally must slope at least 1/4 inch per foot, with the upper
end of the section toward the chimney. Any installation with
a horizontal run of chimney pipe must conform to NFPA 211.
Contact NFPA (National Fire Protection Association) and request the latest edition of the NFPA Standard 211. To
ensure a good draft, the total length of the coupling pipe should never exceed 8’ to 10’ (2.4m to 3.04m). Except
for cases of vertical installation, in a cathedral-roof style where the smoke exhaust system can be much longer and
connected without problem to the chimney at the ceiling of the room. There should never be more than two 90
degrees elbows in the smoke exhaust system. The installation of a “barometric draft stabilizer” (replace register)
on a smoke exhaust system is prohibited. Furthermore, the installation of a draft damper is not recommended.
With a controlled combustion wood stove, the draft is regulated upon intake of the combustion air in the stove
and not at the exhaust.
IMPORTANCE OF PROPER DRAFT
Draft is a force that moves air from the appliance up through the chimney. The amount of draft in your chimney
depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft
may cause excessive temperatures in the appliance. An inadequate draft may cause back-pufng into the
room and “plugging” of the chimney. An inadequate draft will cause the appliance to leak smoke into the room
through appliance and chimney connector joints. An uncontrollable burn or excessive temperature indicates an
excessive draft.
CHIMNEY
Your wood stove may be hooked up with a 6” factory-
built or masonry chimney. If you are using a factory-
built chimney, it must comply with UL 103 or CSA-B365
standard; therefore it must be a Type HT (2100°F). It
must be installed according to the manufacturer’s
specications. Take into account the chimney’s
location to ensure it is not too close to neighbors or
in a valley which may cause unhealthy or nuisance
conditions. If you are using a masonry chimney, it
must be built in compliance with the specications of
the National Building Code. It must be lined with re
clay bricks, metal or clay tiles sealed together with re cement. Round ues are the most efcient. The interior
diameter of the chimney ue must be identical to the stove smoke exhaust. A ue which is too small may cause
draft problems, while a large ue favors rapid cooling of the gas, and hence the build-up of creosote and the
risk of chimney res. Note that it is the chimney and not the stove which creates the draft effect; your stove’s
performance is directly dependent on an adequate draft from your chimney. Do not connect this unit to a
chimney ue serving another appliance.
The following recommendations may be useful for the installation of your chimney:
1. It must rise above the roof at least 3’ (0.9m) from the uppermost point of contact.
2. The chimney must exceed any part of the building or other obstruction within a 10’ (3.04m) distance by a
height of 2’ (0.6m).
3. The installation of an interior chimney is always preferable to an exterior chimney. Indeed, the interior
chimney will, by denition, be hotter than an exterior chimney, being heated up by the ambient air in the
house. Therefore the gas which circulates will cool more slowly, thus reducing the build-up of creosote and
the risk of chimney res.
4. The draft caused by the tendency for hot air to rise will be increased with an interior chimney.
5. Using a re screen at the extremity of the chimney requires regular inspection to ensure that it is not obstructed
thus blocking the draft, and it should be cleaned when used regularly.
To
Appliance
-8-
FACTORY BUILT CHIMNEY
When a metal prefabricated chimney is used, the manufacturer’s
installation instructions must be followed. You must also purchase
(from the same manufacturer) and install the ceiling support
package or wall pass-through and “T” section package, restops
(where needed), insulation shield, roof ashing, chimney cap, etc.
Maintain proper clearance to the structure as recommended
by the manufacturer. The chimney must be the required height
above the roof or other obstructions for safety and proper draft
operation.
MASONRY CHIMNEY
Ensure that a masonry chimney meets the minimum
standards of the National Fire Protection Association (NFPA)
by having it inspected by a professional. Make sure there
are no cracks, loose mortar or other signs of deterioration
and blockage. Be sure to the chimney cleaned before the
stove is installed and operated. When connecting the stove
through a combustible wall to a masonry chimney, special
methods are needed.
-9-
METHOD A - 12” (304.8 mm) Clearance to Combustible Wall
Member: Using a minimum thickness 3.5” (89 mm) brick and a
5/8” (15.9 mm) minimum wall thickness clay liner, construct a
wall pass-through. The clay liner must conform to ASTM C315
(Standard Specication for Clay Fire Linings) or its equivalent.
Keep a minimum of 12” (304.8 mm) of brick masonry between
the clay liner and wall combustibles. The clay liner shall run
from the brick masonry outer surface to the inner surface of the
chimney ue liner but not past the inner surface. Firmly grout or
cement the clay liner in place to the chimney ue liner.
METHOD B - 9” (228.6 mm) Clearance to Combustible Wall
Member: Using a 6” (152.4 mm) inside diameter, listed, factory-
built Solid-Pak chimney section with insulation of 1” (25.4 mm) or
more, build a wall pass-through with a minimum 9” (228.6 mm)
air space between the outer wall of the chimney length and
wall combustibles. Use sheet metal supports fastened securely
to wall surfaces on all sides, to maintain the 9” (228.6 mm) air
space. When fastening supports to chimney length, do not
penetrate the chimney liner (the inside wall of the Solid-Pak
chimney). The inner end of the Solid-Pak chimney section shall
be ush with the inside of the masonry chimney ue, and sealed
with a non-water soluble refractory cement. Use this cement to
also seal to the brick masonry penetration.
METHOD C - 6” (152.4 mm) Clearance to Combustible Wall
Member: Starting with a minimum 24 gage (.024” [.61 mm])
6” (152.4 mm) metal chimney connector, and a minimum 24
gage ventilated wall thimble which has two air channels of 1”
(25.4 mm) each, construct a wall pass-through. There shall be a
minimum 6” (152.4 mm) separation area containing berglass
insulation, from the outer surface of the wall thimble to wall
combustibles. Support the wall thimble, and cover its opening
with a 24-gage minimum sheet metal support. Maintain the 6”
(152.4 mm) space. There should also be a support sized to t
and hold the metal chimney connector. See that the supports
are fastened securely to wall surfaces on all sides. Make sure
fasteners used to secure the metal chimney connector do not
penetrate chimney ue liner.
METHOD D - 2” (50.8 mm) Clearance to Combustible Wall
Member: Start with a solid-pak listed factory built chimney
section at least 12” (304 mm) long, with insulation of 1” (25.4
mm) or more, and an inside diameter of 8” (2 inches [51 mm]
larger than the 6” [152.4 mm] chimney connector). Use this as a
pass-through for a minimum 24-gauge single wall steel chimney
connector. Keep solid-pak section concentric with and spaced
1” (25.4 mm) off the chimney connector by way of sheet
metal support plates at both ends of chimney section. Cover
opening with and support chimney section on both sides with
24 gage minimum sheet metal supports. See that the supports
are fastened securely to wall surfaces on all sides. Make sure
fasteners used to secure chimney ue line do not penetrate the
inner liner.
NOTES:
1. Connectors to a masonry chimney, excepting method B, shall extend in one continuous section through the
wall pass-through system and the chimney wall, to but not past the inner ue liner face.
2. A chimney connector shall not pass through an attic or roof space, closet or similar concealed space, or a
oor, or ceiling.
COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS-THROUGHS
-10-
TYPE
WEIGHT
(LBS. CU. FT., DRY)
PER CORD
EFFICIENCY
RANKING
SPLITS
MILLIONS BTU’s/
CORD
Hickory 63 4500 1.0 Well 31.5
White Oak 48 4100 .9 Fair 28.6
Red Oak 46 3900 .8 Fair 27.4
Beech 45 3800 .7 Hard 26.8
Sugar Maple 44 3700 .6 Fair 26.2
Black Oak 43 3700 .6 Fair 25.6
Ash 42 3600 .5 Well 25.0
Yellow Birch 40 3400 .4 Hard 23.8
Red Maple 38 3200 .3 Fair 22.6
Paper Birch 37 3100 .3 Easy 22.1
Elm/Sycamore 34 2900 .2 Very Difcult 20.1
Red Spruce 29 1800 .1 Easy 16.1
WOODSTOVE UTILIZATION
Your heating appliance was designed to burn wood only; no other materials should be burned. Waste and
other ammable materials should not be burned in your stove. Any type of wood may be used in your stove, but
specic varieties have better energy yields than others. Please consult the following table in order to make the
best possible choice.
Fuel Recommendations
It is EXTREMELY IMPORTANT that you use DRY WOOD only in your wood stove. The wood should have dried for
9 to 15 months, such that the humidity content (in weight) is reduced below 20% of the weight of the log. It is
very important to keep in mind that even if the wood has been cut for one, two, or even more years, it is not
necessarily dry, if it has been stored in poor conditions. Under extreme conditions it may rot instead of drying.
This point cannot be over stressed; the vast majority of the problems related to the operation of a wood stove is
caused by the fact that the wood used was too damp or had dried in poor conditions. These problems can be:
- ignition problems
- creosote build-up causing chimney res
- low energy yield
- blackened windows
- incomplete log combustion
Smaller pieces of wood will dry faster. All logs exceeding 6” in diameter should be split. The wood should not be
stored directly on the ground. Air should circulate through the cord. A 24” to 48” air space should be left between
each row of logs, which should be placed in the sunniest location possible. The upper layer of wood should be
protected from the element but not the sides.
TESTING YOUR WOOD
When the stove is thoroughly warmed, place one piece of split wood (about ve inches in diameter) parallel
to the door on the bed of red embers.
Keep the air control full open and close the door. If ignition of the piece is accomplished within 90 seconds
from the time it was placed in the stove, your wood is correctly dried. If ignition takes longer, your wood is
damp.
If your wood hisses and water or vapor escapes at the ends of the piece, your wood is soaked or freshly cut
(green). Do not use this wood in your stove. Large amounts of creosote could be deposited in your chimney,
creating potential conditions for a chimney re.
-11-
Operating Instructions
CAUTIONS: HOUSE FIRE HAZARDS
Do not store wood on oor protector, underneath stovepipe(s) if applicable, or anywhere within clearances
to combustible surfaces specied for this appliance.
Never operate with secondary tubes, ber board, or insulation removed.
OPERATING SAFETY PRECAUTIONS
Never overre this appliance by building excessively hot res as a house/building re may result. You are
overring the appliance if it begins to glow or turn red.
Never build excessively large res in this type of appliance as damage to the rebox or smoke leakage may
result.
Do not build re too close to glass.
Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skins burns. Do not
touch the appliance until it has cooled.
Provide adequate air for combustion to the room where the appliance is installed.
Inspect chimney liner every 60 days. Replace liner immediately if it is rusting or leaking smoke into the room.
Attempts to achieve heat output rates that exceed heater design specications can result in permanent
damage to the heater.
WARNING: EXPLOSION HAZARD
Never use chemicals, gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter uid, or similar
ammable liquids to start or “freshen up” a re in the appliance.
Keep all ammable liquids, especially gasoline, out of the vicinity of the appliance - whether in use or in
storage.
WOOD STOVE UTILIZATION
The operation of this wood heater in a manner inconsistent with the owner’s manual will void your warranty and is
also against federal regulations. This heater is designed to burn natural wood only. Higher efciencies and lower
emissions generally result when burning air dried seasoned hardwoods, as compared to softwoods or too green
or freshly cut hardwoods.
DO NOT BURN:
1. Garbage;
2. Lawn clippings or yard waste;
3. Materials containing rubber, including tires;
4. Materials containing plastic;
5. Waste petroleum products, paints or paint thinners,
or asphalt products;
6. Materials containing asbestos;
7. Construction or demolition debris;
8. Railroad ties or pressure-treated wood;
9. Manure or animal remains;
10. Saltwater driftwood or other previously salt water-
saturated materials;
11. Unseasoned wood; or
12. Paper products, cardboard, plywood, or
particleboard. The prohibition against burning
these materials does not prohibit the use of re
starters made from paper, cardboard, sawdust,
wax, and similar substances to start a re in an
affected wood heater.
Burning these materials may result in the release of toxic fumes or render the heater ineffective and cause smoke.
Deadwood lying on the forest oor should be considered wet and requires full seasoning time. Standing deadwood
can usually be considered to be about 2/3 seasoned. Splitting and stacking wood before it is stored accelerates
the drying time. Storing wood on an elevated surface from the ground and under a cover or covered area from
rain or snow also accelerates the drying time. A good indicator of if the wood is ready to burn is to check the
piece ends. If cracks are radiating in all directions from the center then the wood should be dry enough to burn.
If your wood sizzles in the re, even though the surface is dry, it may not be fully cured and should be seasoned
longer.
Do not burn manufactured logs made of wax impregnated sawdust or logs with any
chemical additives. Manufactured logs made of 100% compressed sawdust can be
burned, but be careful burning too much of these logs at the same time. Start with one
manufactured log and see how the stove reacts. You can increase the number of logs
burned at a time but make sure the temperature never rises higher than 475 °F (246 °C) on
a magnetic thermometer for installation on single wall stove pipes or 900 °F (482 °C) on a
probe thermometer for installation on double wall stove pipe. The thermometer should be
placed about 18” (457 mm) above the stove. Higher temperatures can lead to overheat
and damage your stove.
-12-
TAMPER WARNING
This wood heater has a manufacturer-set minimum low burn rate that must not be altered. It is against federal
regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating
instructions in this manual.
EFFICIENCIES
Efciencies can be based on either the lower heating value (LHV) or the higher heating value (HHV) of the fuel.
The lower heating value is when water leaves the combustion process as a vapor, in the case of woodstoves the
moisture in the wood being burned leaves the stove as a vapor. The higher heating value is when water leaves
the combustion process completely condensed. In the case of woodstoves this would assume the exhaust gases
are room temperature when leaving the system, and therefore calculations using this heating value consider
the heat going up the chimney as lost energy. Therefore, efciency calculated using the lower heating value of
wood will be higher than efciency calculated using the higher heating value. The best way to achieve optimum
efciencies is to learn the burn characteristic of you appliance and burn well-seasoned wood. Higher burn rates
are not always the best heating burn rates; after a good re is established a lower burn rate may be a better
option for efcient heating. A lower burn rate slows the ow of usable heat out of the home through the chimney,
and it also consumes less wood.
NOTICE - INITIAL BURNS TO CURE PAINT
BECAUSE OF THE HIGH OPERATING TEMPERATURES, THIS APPLIANCE IS COATED WITH A SPECIAL HIGH TEMP PAINT
WHICH REQUIRES A SERIES OF LOW TO MEDIUM BURNS TO FULLY CURE FOR DURABILITY AND A LIFETIME OF SERVICE.
Proper curing of the high-temp paint requires a series of three initial burns. The appliance should be allowed to
cool off between each burn. The rst two burns should be small res and low temperatures (250°F) for a duration
of 20 minutes each. The third re should be at a temperature of approximately 500°F for 20 minutes. Provide
adequate cross ventilation to clear any smoke or odor caused by initial rings.
Notice: Use solid wood fuel only! Do not burn garbage , or ammable uids. Do not use coal. This appliance
is not designed to accommodate the air ow (draft) required to properly burn coal or coal products. Do not
elevate the re using grates or irons. Build the re directly on the rebrick.
FUELING INSTRUCTIONS
This wood stove has been certied by the US EPA to meet strict 2020 guidelines. To ensure this unit produces
the optimal minimum emissions it is critical that only well-seasoned cordwood is burned (see the “Fuel
Recommendations” section of this manual). Burning unseasoned wet wood only hurts your stoves efciency and
leads to accelerated creosote buildup in your chimney. Be considerate of the environment and only burn dry
wood.
For a cold start-up, place 3 to 4 pieces of newspaper into the rebox. On top of
the newspaper, lay 3 lbs of kindling in random placement to ensure airow through
the kindling. On top of the kindling, place approximately 4 lbs of small pieces of
cordwood. NOTE: Use smaller pieces of wood during start-up and a high burn rate
to increase the stove temperature.
CAUTION: DO NOT LEAVE APPLIANCE UNATTENDED THE WITH DOOR OPEN.
4 lb
-13-
After the rst high burn load and the stove is well warmed up, adjust the unit as needed for a medium or low burn
setting.
For a medium burn, once the high burn fuel load is burned down to an established coal bed, load the unit with
18 lbs of cordwood and keep the door slightly open for 3 minutes. Leave the air control fully open (in the “HI”
position) for 13 minutes. After 15 minutes push in the air control to the medium position (midway between the
“Low” and “Hi” position).
For a low burn setting once the high burn (or medium) fuel load is burned down to an established coal bed,
load the unit with 19 lbs of cordwood and close the door immediately. Leave the air control fully open (in the
“HI” position) for 13 minutes. After 15 minutes begin to push the air control in to the “Low” postion (air control fully
pushed in). NOTE: Do not close the air too quickly. Closing the air too quickly will cause the unit to smoke.
18 lbs
LOW
17 lbs
Pull the air control out fully. Light the newspaper and
leave the door slightly open for 2 minutes. Close
the door and allow the kindling to ignite. Once the
kindling has burned down to a starter coal bed,
load the unit with approximately 17 lbs of fuel for
the rst high burn load.
HIGH
ADDING FUEL
1. Once you have obtained a good bed of embers, you should reload the unit. To do so, open the air controls
to maximum a few seconds before opening the stove’s door.
2. Open the door very slowly; open it one or two inches for 5 to 10 seconds, before opening it completely to
increase the draft and thus eliminate the smoke which is stagnant in a state of slow combustion in the stove.
3. Rake the glowing embers to the front of the stove. Add fuel being careful not to overload or overre the
appliance. When adding fuel be careful not to smother the re. Do not build res against glass and make sure
the embers do not obstruct the air inlet. Do not allow logs to roll and strike the glass.
NOTE: For optimal operation of this unit, it is recommend to operate it with a wood load approximately equivalent
to the height of re bricks. It is important to note that wood combustion consumes ambient oxygen in the room. In
the case of negative pressure, it is a good idea to allow fresh air in the room, either by opening a window slightly
or by installing a fresh air intake system on an outside wall.
4. Close the feed door and secure tightly.
WARNINGS:
NEVER OVERFIRE YOUR STOVE. IF ANY PART OF THE STOVE STARTS TO GLOW RED, OVER FIRING IS HAPPENING.
READJUST THE AIR INTAKE CONTROL AT A LOWER SETTING.
THE INSTALLATION OF A LOG CRADLE OR GRATES IS NOT RECOMMENDED IN YOUR WOOD STOVE. BUILD FIRE
DIRECTLY ON FIREBRICK.
NEVER PUT WOOD ABOVE THE FIREBRICK LINING OF THE FIREBOX.
ATTEMPTS TO ACHIEVE HEAT OUTPUT RATES THAT EXCEED HEATER DESIGN SPECIFICATIONS CAN RESULT IN
PERMANENT DAMAGE TO THE HEATER.
-14-
5. Adjust the air inlet control as described in the “Fueling Instruction” section of this manual.
6. Empty ashes regularly. Do not allow ashes to pile up. Properly dispose of hot ashes (see the “Ash Removal And
Disposal” section of this manual).
7. Burn small, intense res instead of large, slow burning res when possible. Large slow burning res can deposit
creosote within the heating system.
8. Learn your appliance’s operating characteristics to obtain optimum performance.
VISIBLE SMOKE
The amount of visible smoke being produced can be an effective method of determining how efciently the
combustion process is taking place in the given settings. Visible smoke consists of unburned fuel and moisture
leaving your stove. Learn to adjust the air settings of your specic unit to produce the smallest amount of visible
smoke. Wood that has not been seasoned properly and has a high wood moisture content will produce excess
visible smoke and burn poorly.
AIR TUBES
The air tubes assembled in this unit are designed to provide an accurate mix of secondary air to ensure the
highest efciency. Any damage or deterioration of these tubes may reduce the efciency of combustion. The air
tubes are held in position by screws or snap pins. Locate these to either side of the tube and remove it to allow
the tube to be removed and replaced.
BLOWER OPERATION
The variable speed blower circulates air warmed by the rebox into the living area to distribute the heat more
evenly. The blower control knob is located on the side of the blower housing. Turn the knob clockwise to turn the
blower on. The speed is controlled by turning the knob clockwise for slower speeds and counter-clockwise for
faster speeds. To turn the blower off, turn the speed control knob fully counter-clockwise. It is recommended to
turn the blower off when the unit is not in operation. The blower needs to be removed and air-blown clean. Make
sure the blades do not have build up.
CAUTION:
Do not overre appliance. You are overring if any part of the appliance glows red. Close the door and shut
damper immediately to reduce the air supply and slow down the re.
Chimney Maintenance
CAUTION:
Slow burning res for extended use or burning green wood may cause excessive creosote build-up. Ignition of
creosote or overring could cause a chimney re. Chimney res burn extremely hot and may ignite surrounding
combustible materials. In case of a chimney re, call the re department immediately!
CREOSOTE FORMATION AND NEED FOR REMOVAL
When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the relatively cool chimney ue of a slow-burning re. As a result,
creosote residue accumulates on the ue lining. When ignited this creosote makes an extremely high temper re.
The chimney connector and chimney should be inspected at least once every two months during the heating
season to determine if a creosote build-up has occurred. If creosote has accumulated (3 mm or more), it should
be removed to reduce the risk of a chimney re.
We strongly recommend that you install a magnetic thermometer on your smoke exhaust pipe, approximately
18” above the stove. This thermometer will indicate the temperature of your gas exhaust fumes within the smoke
exhaust system. The ideal temperature for these gases is somewhere between 275°F and 500°F. Below these
temperatures, the build-up of creosote is promoted. Above 500°F, heat is wasted since a too large quantity is lost
into the atmosphere.
TO PREVENT CREOSOTE BUILD UP
Always burn dry wood. This allows clean burns and higher chimney temperatures, therefore less creosote
deposit.
Leave the air control fully open for about 5 min. every time you reload the stove to bring it back to proper
operating temperatures. The secondary combustion can only take place if the rebox is hot enough.
Always check for creosote deposit once every two months and have your chimney cleaned at least once a
year.
-15-
ASH REMOVAL & DISPOSAL
Whenever ashes get 3 to 4 inches deep in your rebox or ash pan, and when the re has burned down and cooled,
remove excess ashes. Leave an ash bed approximately 1 inch deep on the rebox bottom to help maintain a hot
charcoal bed. Ashes should be placed in a metal container with a tight-tting lid. The closed container of ashes
should be placed on a non-combustible oor or the ground, away from all combustible materials, pending nal
disposal. The ashes should be retained in the closed container until all cinders have thoroughly cooled.
CAUTION:
A chimney re may cause ignition of wall studs or rafters which were assumed to be a safe distance away from
the chimney. If a chimney re occurs, have your chimney inspected by a qualied expert before using again.
ATTENTION:
This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to
operate this wood heater in a manner inconsistent with operating instructions in this manual.
WARNING:
NEVER OPERATE THE STOVE WITHOUT A GASKET OR WITH A BROKEN ONE. DAMAGE TO THE STOVE OR EVEN
HOUSE FIRE MAY RESULT.
SMOKE & CO MONITORS
Burning wood naturally produces smoke and carbon monoxide(CO) emissions. CO is a poisonous gas when
exposed to elevated concentrations for extended periods. While the modern combustion systems in heaters
drastically reduce the amount of CO emitted out the chimney, exposure to the gases in closed or conned areas
can be dangerous. Make sure your stove gaskets and chimney joints are in good working order and sealing
properly to ensure unintended exposure. It is recommended that you use both smoke and CO monitors in areas
having the potential to generate CO.
GLASS CARE
Inspect and clean the glass regularly to detect any cracks. If you spot one, turn the stove off immediately. Do
not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken.
If the glass on your stove breaks, replace only with the glass supplied from your heater dealer. Never substitute
other materials for the glass.
To replace the glass, remove the screws retaining the glass moldings inside the door. Remove the moldings
and replace the damaged piece with a new one. Perform the procedure backward after replacing it. When
replacing the glass, you should change the glass gasket to make sure you keep it sealed.
Never wash the glass with a product that may scratch. Use a specialized product, available in the stores where
wood stoves are sold. The glass should be washed only when cold.
GASKET CARE
This unit’s door uses a 3/4” diameter rope gasket. It is recommended that you change the door gasket (which
makes your stove door air tight) once a year, in order to ensure good control over the combustion, maximum
efciency and security. To change the door gasket, simply remove the damaged one. Carefully clean the
available gasket groove, apply a high temperature silicone sold for this purpose, and install the new gasket. You
may light up your stove again approximately 24 hours after having completed this operation.
CAUTIONS:
ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE.
THE ASH PAN CAN BECOME VERY HOT. WEAR GLOVES TO PREVENT INJURY.
NEVER BURN THE STOVE WITH THE ASH TRAP OPEN. THIS WOULD RESULT IN OVER FIRING THE STOVE. DAMAGE
TO THE STOVE AND EVEN HOUSE FIRE MAY RESULT.
If a chimney or creosote re occurs, close all dampers immediately. Wait for the re to go out and the heater
to cool, then inspect the chimney for damage. If no damage results, perform a chimney cleaning to ensure
no more creosote deposits is remaining in the chimney.
-16-
1
2
3
4
5
9
11
6
7
8
12
13
14
16
17
15
10
Repair Parts
Key Part # Description Qty
1 40292A 6” Flue Collar 1
2 88042 Rope Gasket 1/4” 1
3 25845 Air Deector 1
4 891492 Blower Assembly (B36) 1
5 26060 Rear Shield 1
6 610926 Rear Ashpan (VG2020-BP) 1
7 29068 Pedestal (VG2020-BP) 1
8 29065 Pedestal Front
(VG2020-BP) 1
9 610960 Pedestal Weldment
(VG2020-BP) 1
10 610925 Ashpan Housing
(VG2020-BL) 1
11 610883 Leg Weldment
(VG2020-BL) 4
12 25826 Hearth Plate 1
13 29216 Ash Pan 1
14 610927 Damper Slide Weld 1
15 610066 Slide Retainer Weld 1
16 86954 Damper Rod 1
17 893162 Wooden Knob 1
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST
BE REPLACED USING ORIGINAL MANUFACTURERS PARTS
PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM
THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY
COMPONENTS WILL VOID THE WARRANTY.
-17-
Repair Parts
Key Part # Description Qty
1 88316 Kao Wool Blanket 1
2 88146 Ceramic Fiber Board 1
3 86953 Secondary Air Tube (Ø1/8) 2
4 86952 Secondary Air Tube (Ø11/64) 1
5 29039 Brick Retainer (left) 1
6 29040 Brick Retainer (right) 1
7 40561 Ash Plug 1
8 24103A Half Pumice Firebrick (4-1/2 X 4-1/2) 2
9 891414A Half Firebrick 2
10 89066A Pumice Firebrick (4-1/2 X 9) 14
Key Part # Description Qty
1 893240-VG Complete Door Handle 1
2 891373 Door Hinge Pad (Threaded) 2
3 40880 Lg Square Cast Door 1
4 88082 Round Rope Gasket 3/4” 1
5 893155 Glass 1
6 26314 Gasket Clamp 1
7 29212 Bottom Glass Clamp 2
8 29213 Sides Glass Clamp 2
5
6
2
1
3
4
7
8
1
2
3
6
4
5
7
10
9
8
IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST BE REPLACED USING ORIGINAL MANUFACTURERS PARTS
PURCHASED THROUGH YOUR DEALER OR DIRECTLY FROM THE APPLIANCE MANUFACTURER. USE OF THIRD PARTY
COMPONENTS WILL VOID THE WARRANTY.
It is recommended that your heating system is serviced regularly and that the appropriate Service Interval
Record is completed.
SERVICE PROVIDER
Before completing the appropriate Service Record below, please ensure you have carried out the service
as described in the manufacturer’s instructions. Always use the manufacturer's specied spare part when
replacement is necessary.
Service Record
Service 01 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 03 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 05 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 07 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 02 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 04 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 06 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
Service 08 Date: _____________________
Engineer Name: ________________________________
License No.: ____________________________________
Company: _____________________________________
Telephone No.: _________________________________
Stove Inspected: Chimney Swept:
Items Replaced: ________________________________
United States Stove Company
227
Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com
HOW TO ORDER REPAIR PARTS
COMMANDE DE PIÈCES DE RECHANGE
His manual will help to obtain efcient, dependable service from the heater, and will enable
the correct repair parts to be ordered.
Keep in a safe place for future reference.
When writing, always give the full model number which is on the nameplate attached to the
back of the heater.
When ordering repair parts, always give the following information as shown in this list:
1. The part number _____________________________________________________________________
2. The part description __________________________________________________________________
3. The model number ___________________________________________________________________
4. The serial number _____________________________________________________________________
Ce guide vous aidera à obtenir un service efcace et able de l’appareil de chauffage et
vous permettra de commander correctement
des pièces de rechange.
Veuillez conserver ce guide dans un endroit sûr à des ns de référence.
Lorsque vous nous écrivez, veuillez indiquer le numéro complet du modèle qui gure sur la
plaque signalétique de l’appareil de chauffage.
Lorsque vous commandez des pièces de rechange, veuillez toujours fournir les renseigne-
ments suivants, tels que montrés dans cette nomenclature:
1. Le numéro de pièce __________________________________________________________________
2. Une description de la pièce ___________________________________________________________
3. Le numéro de modèle ________________________________________________________________
4. Le numéro de série ___________________________________________________________________
Il est recommandé que votre système de chauffage est desservi régulièrement et que le Service Interval
enregistrement approprié est terminée.
FOURNISSEUR DE SERVICES
Avant de terminer l’enregistrement de service approprié ci-dessous, s’il vous plaît vous assurer que vous avez
effectué le service tel que décrit dans le les instructions du fabricant. Toujours utiliser pièce de rechange indiquée
par le fabricant lors de remplacement est nécessaire.
Enregistrement De Service
Service de 01 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 03 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 05 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 07 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 02 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 04 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 06 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
Service de 08 Date: _____________________
Nom de l’ingénieur: ____________________________
N° de licence.: _________________________________
Compagnie: ___________________________________
N° de téléphone: _______________________________
Poêle Inspecté: Cheminée balayée:
Articles Remplacé: _____________________________
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

United States Stove Company VG2020-P Le manuel du propriétaire

Catégorie
Poêle à bois
Taper
Le manuel du propriétaire

dans d''autres langues