57,2 cm ou 115,6 cm 56,5 cm ou 114,3 cm
FCC STATEMENT: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures: 1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit different from that of the receiver. (4) Consult the dealer or an experienced
radio/TV technician for help. FCC responsible party name : Good Earth Lighting, Inc. Address: 1400 E Business Center Drive, STE 108, Mount Prospect IL 60056, USA Telephone number: 1-800-291-8838
Hardware Kit: ZH-GL-VHOOKS
REPLACEMENT PARTS LIST:
TROUBLESHOOTING GUIDE
Good Earth Lighting
®
3-YEAR LIMITED WARRANTY: The manufacturer warrants this lighting fixture to be free from defects in materials and workmanship for a period of (3)
years from the date of original purchase by the consumer. The fixture is not warrantied for use in a commercial or retail application. The warranty is limited to use in a residential
environment. We will repair or replace (at our option) the unit in the original color and style if available, or in a similar color and style if the original item has been discontinued,
without charge. Defective units must be properly packed and returned to the manufacturer with a letter of explanation and your original purchase receipt showing date of purchase.
Call 1-800-291-8838 to obtain a return authorization number and an address where to ship your defective product. Note: C.O.D. shipments will NOT be accepted. The liability of
the manufacturer is in any case limited to replacement of the defective light fixture product. The manufacturer will not be liable for any other loss, damage, labor costs, or injury
which is caused by the product. This limitation upon the liability of the manufacturer includes any loss, damage, labor costs, or injury which is (I) to person or property or otherwise;
(II) incidental or consequential in nature; (III) based upon theories of warranty, contract, negligence, strict liability, tort, or otherwise; or (IV) directly, or indirectly related to the sale,
use, or repair of the product. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
Need Help?
Good Earth Lighting® 1400 East Business Center Drive, Ste. 108 Mount Prospect, IL 60056
Good Earth Lighting® is a registered trademark of Good Earth Lighting, Inc. © 2021 Good Earth Lighting, Inc.
Please visit our website at: https://goodearthlighting.com/contact-us or call the Customer Care Center
1-800-291-8838, 8:30 a.m.-5 p.m., CST, Monday-Friday.
The information provided on the packaging should only be used as a suggestion. No guarantees of plant health or yield are guaranteed or inferred with the
use of these lights. Water, soil, fertilizers, temperature, environment, and other factors will impact plant health.
PROBLEM POSSIBLE CAUSES CORRECTIVE ACTIONS
Light does not come on.
Light color does not change.
Timer setting does not change.
Power is shut off at light switch.
Power cord or linking cord is not properly connected.
Timer switch is set to "OFF" and press color button.
Timer is currently running in “OFF” hour.
Color cannot change when auto-timer is engaged.
Auto-timer setting didn’t change when changed.
Change to Manual Mode: Slide timer switch to the “OFF” position
and press color button(s).
.
Auto-Timer Mode: Slide timer switch to the “OFF” position, press
the desired color button(s) and slide switch to timer setting.
Slide timer switch to the “OFF” position and make sure the
desired color button(s) is pressed and slide switch to timer setting.
Linking cord cannot be
inserted into either or both
units being linked.
Cord is being inserted in the wrong direction.
Fixtures need to be linked with the power connector
the same position/direction (power-in side first).
Reverse cord and try inserting again. Plugs only fit one
specific way into the fixtures.
Rotate the last fixture so the power connector is first in-line.
Discontinue use immediately. Call customer service (1-800-291-8838).
Verify light switch are on and a color button has been pressed.
Check cord connection.
Press a color button.
Either reset timer, or wait for cycle to conclude.
Fuse blows or circuit breaker
trips when light is turned on.
PRÉ-INSTALLATION
AVERTISSEMENT:Ne tentez PAS d’altérer le luminaire. Il n’est pas fabriqué avec
des composants pouvant être remplacés ou réparés.
AVERTISSEMENT:RISQUE DE BRÛLURE ! Le luminaire peut être très chaud ; lais-
sez-le refroidir avant de le toucher.
AVERTISSEMENT: N’ALTÉREZ NI LA FICHE, NI LE CORDON. Ce luminaire à
DEL a une fiche polarisée (une broche est plus large que l’autre) afin de réduire le
risque de choc électrique. Cette fiche ne rentrera dans une prise de courant polar-
isée que d’une seule façon. Si la fiche ne s’enfonce pas complètement dans la prise
de courant, essayez de l’enfoncer dans l’autre sens. Si elle ne tient toujours pas
dans la prise, contactez un électricien professionnel. N’utilisez jamais de barrette
d’alimentation électrique, sauf si la fiche peut être insérée complètement.
AVERTISSEMENT : Les produits doivent être installés en suivant ces instructions,
les codes locaux d’électricité et/ou le Code électrique national (CEN) en vigueur. Les
spécifications électriques sont indiquées à l’arrière du luminaire.
AVERTISSEMENT : N’utilisez PAS de cordon de rallonge. Utilisez SEULEMENT des
barrettes d’alimentation avec protection intégrale contre les surintensités.
AVERTISSEMENT: Ne regardez PAS directement les DEL pendant des périodes
prolongées.
MISE EN GARDE :Utilisez cette lampe EXCLUSIVEMENT dans des endroits
où la température de l’air est comprise entre -18° C et 40° C / 0° F et 104° F.
MISE EN GARDE : Acheminez et fixez les cordons UNIQUEMENT de telle façon
qu’ils ne soient pas pincés ou endommagés. Ne suspendez RIEN aux cordons.
MISE EN GARDE : NE montez PAS sur des surfaces dont l'épaisseur est
inférieure à 1/4 po. NE montez PAS au-dessus d'éviers ou de poêles.
MISE EN GARDE : N’UTILISEZ PAS CE LUMINAIRE AVEC UN CIRCUIT
GRADATEUR. Il n’est pas possible d’atténuer l’intensité lumineuse de ce
luminaire.
Mettez hors tension avant de commencer toute opération de maintenance.
Pour emploi à l’intérieur seulement.
Approprié pour les endroits humides.
LISEZ TOUTE LA PROCÉDURE D’INSTALLATION AVANT DE COMMENCER !
AVERTISSEMENTS ET MISES EN GARDE
AVERTISSEMENT : POUR ÉVITER TOUT RISQUE DE CHOC ÉLECTRIQUE, DÉBRANCHEZ LE
LUMINAIRE DE TOUTE SOURCE D’ALIMENTATION ÉLECTRIQUE AVANT DE COMMENCER
L’INSTALLATION.
La longueur du cordon de 1,5 m limite la distance maximale à laquelle le luminaire peut être installé par rapport à une prise de courant. Sélec-
tionnez un endroit pour le montage qui se trouve au maximum à 1,5 m d’une prise de courant. VÉRIFIEZ LES TRAVAUX DE LOCALISATION
AVANT DE COMMENCER À PERCER. Il y a deux façons principales de monter le luminaire : montage sur une chaîne ou montage au ras d’une
surface. Pour un MONTAGE SUR UNE CHAÎNE AVEC DES VIS À CROCHET, marquez 2 trous de montage, espacés de 57,2 cm ou115,6 cm. Pour
un MONTAGE EN SURFACE, faites des marques à 56,5 cm ou 114,3 cm d’intervalle. SEULES les instructions d’installation sur une solive/un
montant en bois ou sur une cloison sèche sont abordées ici.
3
MONTAGE SUR UNE CHAÎNE :
GL1327-AL3-24LFC-G:
Montez les ferrures de
fixation en les espaçant de 57,2 cm
GL1327-AL3-46LFC-G:
Montez les ferrures de
fixation en les espaçant de 115,6 cm
MONTAGE EN SURFACE :
GL1327-AL3-24LFC-G:
Montez les ferrures de
fixation en les espaçant de 56,5 cm
GL1327-AL3-46LFC-G:
Montez les ferrures de
fixation en les espaçant de 114,3 cm